Gemstar Tips for Pain Management Mode

Pain Management Mode

1 Page

Tips for the BAG CHANGE  Pump (Pain Management Mode) LOADING DOSE or CLINICIAN BOLUS DOSE  STOP  STOP & UNLOCK PUMP  AIR IN LINE STOP & UNLOCK PUMP  READING HISTORY (Shortcut to Deliveries & Demands etc) HELP  Do NOT press Start  UNLOCK  Press ENTER then O CHANGE  USE TO SCROLL  PURGE  PRIME THE SET 1. NEW CONTAINER  PROGRAM A LOADING DOSE?  YES START  SET LOADING DOSE AMOUNT  BACKUP to exit Yes DISCONNECT FROM PATIENT  ENTER  PURGE  DELIVER LOADING DOSE NOW ?  PURGE COMPLETE?  (No need to stop or unlock pump).  KEYPAD LOCK When the keypad is in full lock all functions are locked out except access to HELP & OPTIONS (Review Program & Histories)  Shortcut to UNLOCK KEYPAD  • YES  Yes  START  START  To REVIEW PROGRAM  STOP  OPTIONS  Type Unlock Code  1. Review Program  CHANGE PROGRAM  1. To increase or decrease programmed values STOP & UNLOCK the pump, then choose: CHANGE 3 CHANGE PROGRAM  Pump unlocked Pump will flash “Keypad Unlocked” Lock symbol and F no longer appear on screen. (NB If wrong code is entered, press START then STOP and re-enter correct code)  USE TO SCROLL  On completion, press ENTER to exit to main screen (There is no need to stop or unlock the pump)  And follow prompts. 2. To remove background infusion, as above and reduce rate to 0. 3. To add background infusion, STOP & UNLOCK the pump, then select:  CHANGE 2 NEW PROGRAM  To cease infusion then reprogram pump  • • •  Press STOP and close clamps on Gemstar line Unlock keypad –press & hold ON/OFF to turn pump off Release set from pump cassette This is the set release button on  •  Tips You can press the BACKUP key to exit most areas including HELP, CHANGE and OPTIONS You must stop the infusion and unlock the keypad prior to making changes or turning the pump off  The purge key will not work if:  “Start” has been pushed prior to using Purge function to prime the set  If an air in line alarm has not sounded The New Container function will not work if:  The last bag was hung within 2 hours or under 50% of the volume has been infused. How to get around it:  If replacing the line, program a new container prior to priming the line.  If you can not push purge or enter a new container then you will have to reprogram the pump as if for a new patient
File Type: PDF
File Size: 51.7 KB
File Name: Hospira - Gemstar Tips for Pain Management Mode.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions