HoverTech
HoverAppst User Manual Rev A
User Manual
44 Pages
Preview
Page 1
HOVERAPPS User Manual ®
HAManual
Rev A
HOVERAPPS User Manual ®
Table of Contents HT-Wedge... HT-Wedge 1
Introduction...HT-Wedge 2 Intended Use and Precautions...HT-Wedge 3 Part Identification: HT-WedgeTM Adjustable Positioning Device...HT-Wedge 4 Instructions for Use: HT-WedgeTM Adjustable Positioning Device...HT-Wedge 5 Product Specifications /Required Accessories...HT-Wedge 6 Cleaning / Preventative Maintenance / Infection Control...HT-Wedge 7
HT-Roller...HT-Roller 1 Introduction... HT-Roller 2 Intended Use and Precautions... HT-Roller 3 Part Identification: HT-RollerTM Lateral Turning Device... HT-Roller 4 Instructions for Use: HT-RollerTM Lateral Turning Device... HT-Roller 5 Product Specifications /Required Accessories... HT-Roller 6 Cleaning / Infection Control / Preventative Maintenance... HT-Roller 7
AIR SUPPLY...HTAIR 1 Symbol Reference... HTAIR 2 Air Supply Keypad Functions... HTAIR 3 Product Specifications / Required Accessories... HTAIR 4 Electromagnetic Compatibility Charts...HTAIR 5 – 8 Part Identification... HTAIR 9–10 Power Cord / Clamp Replacement... HTAIR 11 Handle Replacement... HTAIR 12 Feet or Bumper Replacement... HTAIR 13 Hose Removal... HTAIR 14 Air Filter and Air Filter Cover Replacement... HTAIR 15 Dust Cover / Hose Attachment Snap Replacement... HTAIR 16 Metal Cover Replacement... HTAIR 17 Cord Strap Replacement... HTAIR 18 Troubleshooting... HTAIR 19 Cleaning... HTAIR 20 Preventive Maintenance / Infection Control... HTAIR 21 Component Parts List... HTAIR 22
General Information...General 1 Warranty Statement... General 1 – 2 Returns and Repairs...General 3
Table of Contents Rev A
HAManual
HOVERAPPS User Manual ®
HT-WEDGE
TM
ADJUSTABLE POSITIONING DEVICE
HT-Wedge 1 HAManual
Rev A
HOVERAPPS User Manual ®
HT-Wedge Adjustable Positioning Device TM
Introduction Description of the HT-Wedge Adjustable Positioning Device TM
The HT-Wedge is an inflatable positioning device that lifts and positions a patient’s head and chest without manual lifting. The dual chamber design of the HT-Wedge features two (2) self-sealing valves that allow the patient’s chest and head to be elevated or lowered individually for easy, customizable positioning. A small, variable speed air supply controls the inflation speed for ease of use and patient comfort. The HT-Wedge has a maximum weight bearing capacity of 800 lbs.
Benefits of the HT-Wedge Adjustable Positioning Device TM
• Two chamber design provides maximum adjustability of the head and chest without manual lifting. • Valves located on each chamber are clearly labeled to facilitate easy identification for head and chest inflation. • Microbial-controlling nylon minimizes infection risk. • Rapid inflation and deflation helps maintain efficient workflow. • Low profile when deflated allows product to be left underneath the patient.
HT-Wedge 2 Rev A
HAManual
HOVERAPPS User Manual ®
HT-Wedge Adjustable Positioning Device TM
Intended Use and Precautions Indications for Use: The purpose of the HT-Wedge is to pneumatically lift and position the head and chest of a patient who is lying in the supine position without manual lifting. Contraindications: Patients who are experiencing thoracic, cervical or lumbar fractures that are deemed unstable. Intended Care Settings: Hospitals, long term or extended care facilities. Precautions – General: • Caregiver(s) must ensure the patient is attended and stabilized while on the HT-Wedge. • Always use a minimum of two caregivers when operating the HT-Wedge. • Product should only be used by trained personnel. • Only use attachments and /or accessories that are authorized by HoverTech International. Precautions – HT-Wedge: • Ensure the HT-Wedge meets the patient’s needs before using. • A clinical assessment should be carried out by a qualified medical professional before positioning patients using the HT-Wedge. • Make sure patient is centered on the HT-Wedge before inflating. • Never leave the patient unattended while using the HT-Wedge. • Use the HT-Wedge according to instructions. • Do not launder. Precautions – HoverTech International Air Supply: • Route the power cord in a manner to ensure freedom from hazard. • Avoid blocking the air intakes of the Air Supply. • Use this product only for its intended purpose as described in this manual. CAUTION: Avoid electric shock. Do not open Air Supply.
HT-Wedge 3 HAManual
Rev A
HOVERAPPS User Manual ®
HT-Wedge Adjustable Positioning Device TM
Part Identification Head Chamber
Chest Chamber
Securing Flap
Inflation / Deflation Valve (2)
Rail Stra
ps (4)
HT-Wedge 4 Rev A
HAManual
HOVERAPPS User Manual ®
HT-Wedge Adjustable Positioning Device TM
Instructions for Use 1. Place the HT-Wedge on the surface where it is to be used and secure with rail straps by using the appropriate snaps for the width of the table. 2. For head and chest elevation, center patient on the HT-Wedge, with the patient’s head close to the top edge of the pillow. 3. To begin inflation, hold the HoverTech HTAIR1200 air supply hose against the head inflation valve. Press the ADJUSTABLE button on the HTAIR1200 keypad to initiate air flow and select the appropriate speed. Partially inflate head pillow. Move hose to chest inflation valve and inflate to desired height. Then, finish inflating head pillow.
ADJUSTABLE Use for HT-Wedge and HoverApps 4. The firmness can be reduced by pressing the diaphragm in each inflation valve. This will slowly deflate the chamber and allow the firmness to be adjusted. 5. When the procedure is complete, deflate the HT-Wedge by pressing the diaphragm in each inflation valve until both chambers are fully deflated. The HT-Wedge can be re-inflated as necessary.
NEVER LEAVE PATIENT UNATTENDED ON AN INFLATED HT-WEDGE.
HT-Wedge 5 HAManual
Rev A
HOVERAPPS User Manual ®
HT-Wedge Adjustable Positioning Device TM
Product Specifications / Required Accessories • Patient Weight Limit: 800lbs. (363 kg) HT-Wedge Adjustable Positioning Device TM
Material:
Double-Coated Nylon Twill
Construction:
Heat-Sealed
Width:
22" (56 cm) (Deflated)
Length:
30" (76 cm) (Deflated)
Required Accessories for Use:
HTAIR1200 – HoverTech International Air Supply (North American Version) HTAIR2300 – HoverTech International Air Supply (European Version)
All HoverTech International Products are Latex-Free.
HT-Wedge 6 Rev A
HAManual
HOVERAPPS User Manual ®
HT-Wedge Adjustable Positioning Device TM
Cleaning Using a germicidal cleaner (phenolic disinfectant, quaternary solution or other intermediate level disinfectant according to facility protocol) and a damp cloth, completely wipe down to disinfect the HT-Wedge. Apply germicidal cleaner directly into hard to reach areas. Let air dry. Do not launder.
Infection Control Whatever the patient is lying on to keep the surface clean may be placed on top of the HT-Wedge to help keep it clean. If desired, a disposable sheet may be used to cover the HT-Wedge (available for separate purchase). If the HT-Wedge is used on an isolation patient, the hospital should employ the same protocols /procedures it utilizes for the bed mattress and /or for the linen in that patient room.
Preventive Maintenance Prior to use, a visual inspection should be performed on the HT-Wedge to ensure that there is no visible damage that would render the HT-Wedge unusable. The HT-Wedge should be periodically inspected to ensure the following: • All inflation /deflation valves are self-sealing with no evidence of leakage. • All rails straps are attached to the HT-Wedge. • All snaps are intact and operational. • There are no punctures or tears in the HT-Wedge. If any damage is found that would cause the HT-Wedge not to function as intended, the HT-Wedge should be removed from use and returned to HoverTech International for repair (see General 3 Returns and Repairs).
HT-Wedge 7 HAManual
Rev A
HOVERAPPS User Manual ®
HT-ROLLER
TM
LATERAL TURNING DEVICE
HT-Roller 1 Rev A
HAManual
HOVERAPPS User Manual ®
HT-Roller Lateral Turning Device TM
Introduction Description of the HT-Roller Lateral Turning Device TM
The HT-Roller is an inflatable device for lateral turning of patients who are unable or have a reduced capacity to assist in their own turning. The device comprises two chambers that are inflated with a small variable speed air supply. By eliminating the need for manual lifting, the HT-Roller protects both the staff from injury and the patient from friction and shearing associated with traditional repositioning methods.
Benefits of the HT-Roller Lateral Turning Device TM
• Turning chambers provide periodic pressure relief from bony prominences. • Adjustable positioning facilitates better access for hygiene and wound care applications. • Quick release valves allow for rapid deflation of turning chambers. • Breathable fabric prevents moisture build-up and enhances patient comfort. • Disposable device eliminates the need for reprocessing and reduces potential for cross contamination. • Variable speed air supply allows caregiver to control inflation for patient safety and comfort.
HT-Roller 2 HAManual
Rev A
HOVERAPPS User Manual ®
HT-Roller Lateral Turning Device TM
Intended Use and Precautions Indications for Use: The purpose of the HT-Roller is to laterally turn and position a patient who is lying in the supine position without manual lifting. Contraindications: Patients who are experiencing thoracic, cervical or lumbar fractures that are deemed unstable. Intended Care Settings: Hospitals, long term or extended care facilities. Precautions – General: • Caregiver(s) must ensure the patient is attended and stabilized while on the HT-Roller. • Always use a minimum of two caregivers when operating the HT-Roller. • Product should only be used by trained personnel. • Only use attachments and/or accessories that are authorized by HoverTech International. Precautions – HT-Roller: • Ensure the HT-Roller meets the patient’s needs before using. • Make sure patient is centered on the HT-Roller before inflating. Reference center line marked on the HT-Roller. • Do not leave patient unattended during HT-Roller inflation, deflation or when inflated at angles greater than 30 degrees. • Use the HT-Roller according to instructions. • Do not launder. Precautions – HoverTech International Air Supply: • Route the power cord in a manner to ensure freedom from hazard. • Avoid blocking the air intakes of the Air Supply. • Use this product only for its intended purpose as described in this manual. CAUTION: Avoid electric shock. Do not open Air Supply.
HT-Roller 3 Rev A
HAManual
HOVERAPPS User Manual ®
HT-Roller Lateral Turning Device TM
Part Identification Securing Apron Turning Chambers (2)
Red Deflation Valve (2)
Inflation Valve (2)
Label Includes Model #, Serial #, or Lot #, and Instructions for Use
HT-Roller 4 HAManual
Rev A
HOVERAPPS User Manual ®
HT-Roller Lateral Turning Device TM
Instructions for Use 1. Ensure that the red valves are capped tightly before beginning inflation. 2. Place the deflated HT-Roller on the bed mattress. If the patient is already on the mattress, place the device under the patient by using a log-rolling technique. Ensure all side rails are up. Whatever the patient is lying on to keep the bed mattress clean can be placed on top of the HT-Roller. 3. Tuck the securing apron of the HT-Roller under the bed mattress to keep in place during use. 4. Locate the inflation valve that is positioned on the OPPOSITE side of the turn direction and place the Air Supply hose over the valve. Press the ADJUSTABLE button on the HoverTech HTAIR1200 keypad to initiate air flow. If necessary, press this button up to 3 more times to increase air flow and rate of inflation.
ADJUSTABLE Use for HT-Wedge and HoverApps 5. When the turn is complete, remove hose from valve and press the STANDBY button on the Air Supply keypad to stop air flow. Note: Chamber may not need to be fully inflated to achieve turn.
6. To deflate the HT-Roller, remove the red cap from the deflation valve. This will quickly deflate the positioning device. Make sure the patient is attended and stabilized during deflation.
HT-Roller 5 Rev A
HAManual
HOVERAPPS User Manual ®
HT-Roller Lateral Turning Device TM
Product Specifications / Required Accessories • Patient Weight Limit: 600lbs. (272 kg) HT-Roller Lateral Turning Device TM
Material:
Non-Woven Polypropylene
Construction:
Heat-Sealed
Width:
Chambers: 44" (112cm) (combined chamber width) Apron: 70" (178cm)
Length:
Chambers: 44" (112cm) Apron: 44" (112cm)
Required Accessories for Use:
HTAIR1200 – HoverTech International Air Supply (North American Version) HTAIR2300 – HoverTech International Air Supply (European Version)
All HoverTech International Products are Latex-Free.
HT-Roller 6 HAManual
Rev A
HOVERAPPS User Manual ®
HT-Roller Lateral Turning Device TM
Cleaning Using a germicidal cleaner (phenolic disinfectant, quaternary solution or other intermediate level disinfectant according to facility protocol) and a damp cloth, completely wipe down to disinfect the HT-Roller. Apply germicidal cleaner directly into hard to reach areas. Let air dry. Do not launder.
Infection Control Whatever the patient is lying on to keep the surface clean may be placed on top of the HT-Roller to help keep it clean. If desired, a disposable sheet may be used to cover the HT-Roller (available for separate purchase). If the HT-Roller is used on an isolation patient, the hospital should employ the same protocols /procedures it utilizes for the bed mattress and/or for the linen in that patient room.
Preventive Maintenance Prior to use, a visual inspection should be performed on the HT-Roller to ensure that there is no visible damage that would render the HT-Roller unusable. The HT-Roller should be periodically inspected to ensure the following: • All inflation valves are self-sealing with no evidence of leakage. • There are no punctures or tears in the HT-Roller. If any damage is found that would cause the HT-Roller not to function as intended, the HT-Roller should be removed from use.
HT-Roller 7 Rev A
HAManual
HOVERAPPS User Manual ®
AIR SUPPLY
NO USER SERVICEABLE PARTS. Only qualified service personnel shall perform repairs on the HoverTech International Air Supply.
HTAIR 1 HAManual
Rev A
HOVERAPPS User Manual ®
Air Supply Symbol Reference
Attention! Please read accompanying documents.
This End Up
Type BF Applied Part
Temperature
Declaration of Conformity to Medical Device Directive
Humidity
Functional Earth (Ground)
Date of Manufacture
Alternating Current
Keep Dry
Underwriters Laboratory Agency Approval
120 V~: Medical Equipment with respect to electrical shock, fire and mechanical hazards only in accordance with UL 60601-1, IEC/EN 60601-1, CAN/CSA C22.2 No. 601.1
230 V~: Medical Equipment with respect to electrical shock, fire and mechanical hazards only in accordance with UL 60601-1, IEC 60601-1-2 CAN/CSA C22.2 No. 601.1
~
HTAIR 2 Rev A
HAManual
HOVERAPPS User Manual ®
Air Supply Keypad Functions Adjustable Speed Indication
Power Indication
Adjustable/ Pressure Setting
Transfer Speed High Standby
Transfer Speed Low
The Adjustable Keypad function has four different settings. Pressing the button once will result in the lowest inflation setting available. A second press of the button increases the air pressure and rate of inflation. Pressing the button a third time will again increase the rate of inflation. A fourth press of the button results in the highest inflation rate and air pressure available for HoverTech Accessories. The STANDBY button may be pressed at any time to cease all air flow. NOTE: The LED will indicate the inflation speed by the number of flashes (i.e. two flashes equals the second inflation speed). All of the settings in the Adjustable range are substantially lower than the HoverMatt® and HoverJack® settings. The Adjustable function is not to be used for transferring; it is only for use with HoverApps, which require a lower pressure for slow inflation. Standby: Used to stop inflation/air flow.
HoverMatt® 28/34: For use with 28" and 34" HoverMatt® Air Transfer Mattresses. HoverMatt® 39/50 and HoverJack®: For use with 39" and 50" HoverMatt® Air Transfer Mattresses and 32" and 39" HoverJack® Air Patient Lifts.
HTAIR 3 HAManual
Rev A
HOVERAPPS User Manual ®
Air Supply Product Specifications / Required Accessories Classification: • Not for use in the presence of flammable anesthetics or in a hyperbaric chamber or oxygen tent. • Type of protection against electric shock: CLASS I EQUIPMENT • Degree of protection against electric shock: TYPE BF APPLIED PART • Protection against ingress of water: Ordinary (not protected). • Mode of operation: CONTINUOUS OPERATION • To remove supply mains, unplug equipment from wall. • Use Temperature:
50° to 104° F (10° to 40° C)
• Use Humidity:
10% to 70% Non-Condensing
• Storage/Shipping Temperature: – 40° to 176° F (– 40° to 80° C) • Storage/Shipping Humidity:
10% to 70% Non-Condensing
• Power Input:
120 V~, 60 Hz, 10 A (North American version)
230 V~, 50 Hz, 6 A (European Version)
• Air Supply Dimensions:
12.5 x 7 x 7 inches (31.75 x 17.8 x 17.8 cm)
• Air Supply Weight:
11 lbs. (5 kg)
• Air Supply Material:
Fire Retardant ABS/Stainless Steel
• Power Cord Length:
15 feet (457 cm)
HoverTech International Air Supply Part# HTAIR1200 (North American Version) Part# HTAIR2300 (European Version)
HTAIR 4 Rev A
HAManual