HS CLEMENT CLARKE INTERNATIONAL
AC2000, World Traveller, Econeb and Turboned 2 Operating Instruction issue 9 Jan 2012
Operating Instruction
2 Pages
Preview
Page 1
12 Year Pack for AC2000 (2012) Adult Year pack (2012)... L3605125 Contents: as above but with no outlet filter. Child Year Pack (2012)... L3605124 Contents: as above but with child size face masks and no outlet filter.
Clement Clarke International Limited, Edinburgh Way, Harlow, Essex CM20 2TT UK Telephone: +44 (0)1279 414969 Fax: +44 (0)1279 456300 www.clement-clarke.com e-mail: [email protected]
Please note: All our masks are made from a strong plastic with anti-microbial and low static properties, and are phthalate free.
Catalogue no: 1902328 Issue no: 9 01/12
Year Pack for World Traveller, AC2000, Econoneb & Turboneb 2 Adult Year pack... L3605122 Contents: 4 nebuliser chambers, 4 drivelines, 4 adult face masks, 1 mouthpiece, 4 inlet filters and 1 outlet filter. Child Year Pack... L3605123 Contents: as above but with child size face masks. Items for Econoneb and Turboneb 2 Fuse Pack (2 x T1AL)... 3605534
62VA (260mA)
Power Consumption
64VA (270mA)
68VA (296mA)
Fuse
1 x T1AL 20mm long
Fuse
1 x T1AL 20mm long
1 x T1AL 20mm long
Nominal Flow
Min flow 7 L/min, Max flow 9 L/min @ 138 kPa*
Nominal Flow
Min flow 7 L/min, Max flow 9 L/min @ 138 kPa*
Min flow 9.5 L/min Max flow 10.5 L/min @ 138 kPa*
Weight
2.8 kg (without starter pack)
Weight
2.7 kg
2.7 kg
Dimensions
375mm x 235mm x 115mm
Dimensions
210mm x 185mm x 185mm
210mm x 185mm x 185mm
Type Rating
Class II BF Continuous
Type Rating
Sound Pressure Level
Class II BF Continuous
Class II BF Continuous
60 dbA approx.
Sound Pressure Level
63 dbA approx.
63 dbA approx.
0120 Purchase your nebuliser and consumables at: www.clement-clarke.com Please read these instructions before using the equipment
Refer to the colour coded pages, applicable to your machine
Econoneb Turboneb 2 Hi-Flo
AC2000 World Traveller Notes on Nebuliser Care Caution 1 Do not immerse machine in water. 2 Physician prescribed use only. 3 Never use more frequently than prescribed. 4 If therapy is having no effect, consult physician.
EMC (Electro Magnetic Compatibility) Declaration With the increased number of electronic devices such as PC’s and mobiles, medical devices in use may be susceptible to electromagnetic interference from these devices. Which may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC with the aim to prevent unsafe product situations, the EN60601-1-2 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.
Cleaning In order that you benefit fully from your equipment, it is important that the machine and accessories are kept in a clean condition. Ensure that the medication chamber is taken apart and washed in warm soapy water. Rinse and allow to dry after each use. The jet holes should be blown clear by attaching the chamber to the air outlet from the compressor and running the machine for a couple of minutes. We advise that the tube is disconnected from both the outlet filter and the chamber after each use to prolong the life of the connector.
Replacement It is recommended that the following disposable items should be changed as follows: Nebuliser chamber Inlet filter Driveline Face mask
Troubleshooting If the green light in the mains switch is on, yet the motor does not function, there is an internal fault. The machine should be returned to the point of purchase or an authorised person for examination. If the green light(s) on the switches are off:
Air compressor will not operate when switched on.
Action
Problem
1. Check mains lead is securely connected each end. 2. For machines with a 3 pin plug (UK) remove and check the fuse in the plug. Fuse - 3.15AL 25mm long. 3. Check mains fuse in the control panel. AC2000 & World Traveller fuse - T1AL 20mm long. 4. If battery/pump switch light is off (World Traveller only), check DC fuse in control panel. Fuse - T5AL 20mm long. 5. Disconnect unit from electricity supply. Check mains fuse in the mains inlet socket.
Medical devices manufactured by Clement Clarke International Ltd conform to this EN60601-1-2 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: The use of accessories and cables other than those specified by Clement Clarke Int. Ltd, with the exception of cables sold by Clement Clarke International Ltd. as replacement parts for internal components, may result in increased emission or decreased immunity of the device. The medical devices should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is unavoidable, the medical device should be seen to operate normally as it should in this situation. Further guidance regarding the EMC environment (in accordance with EN60601-1-2) in which the device should be used is available at www.clement-clarke.com/ medicalquality
Guarantee This guarantee is offered to you as an extra benefit and does not affect your statutory rights.
change every 3 months
CCI products are carefully designed, manufactured and inspected. CCI undertake to replace or repair any part found to be defective in material or workmanship subject to the following terms and conditions:
} change every 12 months
Mouthpiece Outlet filter
Only nebuliser chambers supplied or approved by CCI should be used.
Storage
AC (mains) Min flow 7 L/min, Max flow 8.5 L/min @ 138 kPa* DC (battery) Min flow 6.5 L/min, Max flow 8.5 L/min @ 138 kPa*
Power Consumption
Operating Instructions for the following four nebuliser systems The machine should be stored in a dust and smoke-free area.
Nominal Flow
230V / 50Hz
Recommended:
T1AL 20mm long, T5AL 20mm long, T3.15AL 20mm long (rechargeable battery pack fuse)
220V-240V / 50Hz
0˚c - 40˚c RH: 15% - 95% Pressure: 950hPa - 1020hPa
60 dbA approx.
Fuse
Operating Voltage
The compressor/motor, excluding serviceable parts, are guaranteed for three years on condition that: the unit is serviced every 12 months for the first three years. cleaned and maintained in accordance with the instructions. servicing is undertaken by CCI approved engineers/agents. only CCI approved parts may be used to service this equipment. Where a rechargeable battery is supplied, a three months guarantee applies.
Safety Precautions
Sound Pressure Level
80VA 350mA-700mA~or 3.0A 220V-240V / 50Hz
∗ Always disconnect from electricity supply before undertaking any maintenance or cleaning.
Class II BF Intermittent (use for 60 mins; do not reuse within 60 mins) 50-60Hz
Power Consumption Operating Voltage
Should this happen, switch off at mains and unplug immediately.
Type Rating Frequency
UK/EU
∗ Never operate the unit where it may come into contact with water.
375mm x 235mm x 115mm 110-240V~ or 12V
UK/EU
fibres can be drawn into the unit when in use.
Dimensions Operating Voltage
Items for World Traveller Part no. Fuse pack for World Traveller (2 x T1AL, 1 x T5AL, 1 x T3.15AL) 3605535 DC cigar lighter lead... 3605667 Rechargeable battery pack... 3605290 Shoulder bag... 3607691 Items for AC2000 Fuse Pack (2 x T1AL)... 3605534 Shoulder bag... 3607691 Country
Turboneb 2
∗ Never block air intake grills on the carrying case. ∗ Always keep electrical leads clear of heated surfaces. ∗ Position the unit on a clean surface. Do not place on carpet where
11 denotes AC denotes DC Without battery 2.8 kg With battery 3.6 kg Worldwide
World Traveller Hi-Flo UK/EU
Econoneb
Technical Specifications - cont. ∗ Avoid using in a room where people smoke. ∗ Store in a clean, dry, dust free environment at room temperature. ∗ Not suitable for use with flammable anaesthetic gases. ∗ Do not modify the equipment or its accessories in any way. ∗ Do not allow liquid to enter the mains input socket.
~
Weight Country
Spares and Accessories *1 kPa = 0.01bar or 0.145psi Country
AC2000
Technical Specifications
This guarantee does not apply to: The disposable nebuliser chamber, driveline, face mask, mouthpiece and filters. Defects arising from misuse, negligence, improper maintentance, accident, damage in shipment or unauthorised modification or service. Regular servicing at 12 monthly intervals. To register this guarantee please return the card, supplied with this handbook, within 15 days of purchase. CCI shall not be liable for any third party or consequential loss or damage of whatever nature arising from or in connection with this equipment. Should it become necessary to make a claim under guarantee, return the unit properly packed (preferably in the original packaging) to the point of purchase (the manufacturer, shop, distributor or outlet where the device was purchased). Please include name and address, details of problem and proof of date of purchase (please retain original invoice). Carriage costs to be paid by the customer.
8
1. Check inlet filter. Replace if necessary. 2. Wash nebuliser chamber. Replace if problem still occurs. 3. Check driveline tubing is not kinked or leaking. Replace if necessary. 4. Service compressor.
Nebuliser chamber bubbles or produces little or no mist.
1. Check battery/pump switch is on and illuminates. 2. Check the rechargeable battery pack fuse. Fuse - T3.15AL 20mm long. 3. If the low battery indicator is on, recharge battery for 16 hours maximum.
World Traveller will not operate from the rechargeable battery pack
1. Check battery/pump switch is on. 2. Check cigar lighter lead is clean and working. 3. Check the DC fuse in the control panel. Fuse - T5AL 20mm long. 4. Check the soldered connections on the plug and the cigar lighter adaptor on the lead.
World Traveller will not operate from the cigar lighter lead.
Time taken to nebulise significantly increases.
Disposal Instructions All Nebulisers, including batteries where applicable, should NOT be disposed of with household waste as they are not bio-degradable in landfill sites. They should NOT be incinerated. For safe disposal take to: The local (council/authority) environmental waste site, (in accordance with the European Environmental directive). For details contact your local authority/recycling centre. IMPORTANT The wires of the mains lead wires are coloured in accordance with the following code: Blue - Neutral Brown - Live As these colours may not correspond to the coloured markings sometimes used to identify the terminals in a plug, proceed as follows: Connect the Blue wire to the terminal marked N or coloured black. Connect the Brown wire to the terminal marked L or coloured red. NB Neither wire should be connected to the earth pin marked E or coloured green or yellow and green.
9
10
Introduction
Symbols Consult ‘Instructions for Use’
Caution
World Traveller Hi-Flo
These nebuliser systems are designed to deliver a fine aerosol mist from the liquid medication prescribed by your doctor to treat your respiratory condition. Use according to the instructions given by your doctor or physician. Please read the instructions carefully to obtain the maximum benefit from the nebuliser systems.
Control Panel
battery/pump switch
DC Fuse (T5AL)
~ Fuse (T1AL)
AC2000
This mains only nebuliser has been designed to operate from ~ mains voltage, 220V-240V ~ 50 Hz.
Do not allow liquid to enter mains input socket
This portable nebuliser system has been designed for use anywhere in the world. It will automatically operate from all ~ mains voltages in the range 110-240V 50-60Hz without any adjustments to the machine. This model will also operate from a 12V DC battery using the DC lead supplied when connected to a car cigar lighter attachment. An optional built-in rechargeable battery pack is also available.
Inlet filter
Note: The World Traveller is intermittently rated and is fitted with thermal cut-outs to protect the equipment. It can be used for continuous treatment for up to 60mins. Do not re-use within 60mins.
Outlet filter
T1AL
Battery Information: A safety feature has been fitted to the battery to prevent it from overheating. Should you use your World Traveller immediately after charging the Battery Pack you may notice the battery does not give maximum ouput and may run intermittently. Please switch off and allow the battery to cool for at least an hour before use.
Fuse T1AL
Battery/Pump switch
T5AL
World Traveller Hi-Flo
AC2000
mains switch on/off
mains input socket
AC Mains Operation
1. Connect mains lead to the mains input socket shown above and to mains power supply. 2. Connect driveline to outlet filter nozzle. 3. Connect nebuliser chamber, followed by mouthpiece or face mask, to the driveline and press mains switch on (I). 4. Press battery/pump switch on (I) to operate. 5. To switch unit off, first press battery/pump switch to (O), then press mains switch off. Disconnect from mains.
Note: The machine is supplied with a mains plug. When using it in overseas countries, a universal adaptor may be required to suit the local socket.
DC Operation
Note: From new, batteries are not connected in World Travellers. Follow connection instructions detailed under 'Installing New Battery Pack'. 1. The machine operates direct from the built-in rechargeable battery pack by pressing battery/pump switch on (I). 2. When fully charged the battery pack will operate the compressor for about 35 minutes. Recharge when the red ‘low battery’ light illuminates.
Low battery light Battery charge light
12V DC input socket
Class II Equipment
Do not dispose of with household refuse
Mains ~ Operation 1. Carefully withdraw nebuliser from the box. 2. Connect mains lead to a mains power supply. 3. Connect driveline to outlet filter nozzle. 4. Connect nebuliser chamber, followed by mouthpiece or face mask, to the driveline. 5. Press mains switch on (I). The switch will illuminate and the equipment can now operate.
2
To Replace ‘inline’ Battery Fuse
1. Switch off at mains. 2. Using a screwdriver or a coin push and twist fuse in an anti-clockwise direction to extract fuse. 3. Replace fuse.
The AC2000 and World Traveller are supplied with a starter kit consisting of:
Introduction
1 x driveline 1 x mouthpiece 1 x filter spanner
1. Twist and pull fuse casing in an anti-clockwise direction. 2. Replace fuse, T3.15AL fuse.
Installing New Battery Pack
If you have purchased a battery pack at a later stage, install it as follows:1. Lift inner lid to the battery pack compartment. Fuse T3.15AL 2. Connect plug on battery pack lead to socket 1. Lift lid on left hand side of battery compartment. 3. Fit battery pack into compartment so velcro strips meet to fix in position. E
NT CLARK CLEMENATIONAL INTER
2.
3
3.
4
Turboneb 2/Econoneb
hard-wired lead
(Hard-wired)
These nebuliser systems are designed to deliver a fine aerosol mist from the liquid medication prescribed by your doctor to treat your respiratory condition. Use according to the instructions given by your doctor or physician. Please read the instructions carefully to obtain the maximum benefit from the nebuliser systems.
When the red ‘low battery’ light illuminates recharge as follows:
Note: To obtain the maximum life from your battery pack always store battery in a fully charged condition, as follows: 1. Every three months charge for 16 hrs maximum. Discharge by using from battery until red light appears, recharge for 16 hrs maximum. 2. If battery pack is completely discharged, red light will not illuminate.
To Replace Fuse
1 x nebuliser chamber 1 x inlet filter 1 x adult face mask 1 x child face mask
Recharging Battery Pack 1. Connect mains lead to the mains input socket on the control panel and to the mains power supply. Press mains switch on (I). 2. The green battery charge light should now illuminate. The battery pack is being recharged. Note: The battery/pump switch MUST be at the off (O) position. 3. After recharging for 16 hours maximum press mains switch off (O). Disconnect mains lead.
Operating Instructions
Tested and approved by Nemko, Norway. Complies with IEC 60601-1 and IEC 60601-1-2. This product complies with the essential requirements of the medical devices directive (93/42/EEC). Compliance has been verified by UK notified body per 0120 (SGS United Kingdom Ltd).
mains switch
inlet filter nozzle
Type BF Equipment
Filling the Nebuliser Chamber For Single Patient Use 1 Connect one end of the driveline to the outlet filter on your compressor.
Econoneb
outlet filter nozzle
2 Connect the other end of the driveline to the bottom of the blue nebuliser cup.
inlet filter
The Econoneb is supplied with a starter kit consisting of: 1 x nebuliser chamber 1 x driveline 1 x mouthpiece 1 x child face mask
12V DC input socket
Battery Operation
~ Fuse (T1AL) - AC2000
0120
battery charge light
1. Connect cigar lighter lead to 12V input socket on control panel. 2. Connect the other end of the lead to the cigar lighter socket in the car. Press battery/pump switch on (I) to operate.
DC Fuse Empty Battery: Full Battery:
12V DC
inlet filter nozzle
low battery light
T1AL Fuse
1 x adult face mask 1 x inlet filter 1 x filter spanner
On/Off Switch
= On
3 Remove the nebuliser top from the cup and pour medication into the cup (max. 10ml.) = Off
4. Screw the top back onto the cup.
Turboneb 2 Particle Size Distribution
The Turboneb 2 supplies the highest flow rate for nebulising viscous antibiotics and has been designed to operate from ~ mains voltage. Two versions are available, UK and EURO, (i.e. plug type) both 220-240V ~ 50Hz.
The Turboneb 2 is not supplied with a starter kit. Note: Both machines are continuously rated for repeat use. Please refer to the information label on the base of the machine to establish that you have the correct voltage for your mains supply.
Econoneb/Turboneb 2
All accessories must comply with EN 13544-1
Nebuliser + Microneb III Cumulative % undersize
This compressor-only unit provides flexibility for the user to choose the most appropriate accessories for demanding applications.
Servicing Microns
Mains ~ Operation
To Replace Fuse 1. Switch off at mains. 2. Using a screwdriver or a coin push and twist fuse in an anti-clockwise direction to extract fuse. 3. Replace fuse.
5
Administering the Medication Switch the compressor unit on. Sitting in an upright relaxed position, place mouthpiece into the mouth (or face mask over the nose and mouth) and start breathing slowly and deeply. Do not try to breathe quickly. If you have any problems seek instruction from your doctor or physiotherapy department at your hospital. Switch off the compressor when the misting has stopped. Unplug the mains lead.
Operating Instructions 1 Connect mains lead to mains power supply. 2 Connect driveline to outlet filter nozzle (see page 7). 3 Connect nebuliser chamber, followed by mouthpiece or face mask, to the driveline (see page 7). 4 Press mains switch on (I). The switch will illuminate and the equipment can now operate.
5. Connect either the face mask or mouthpiece to the nebuliser top.
Key: AC2000 Econoneb Turboneb 2 World Traveller Note: The performance information provided is in accordance with standard EN 13544-1 but may not apply to drugs supplied in suspension or high viscosity form. In these cases, information should be sought from the drug supplier.
6
In order to maintain your warranty, your unit is required to be serviced by an approved service agent every 12 months. Please contact the manufacturer or distributor for details of your nearest authorised service agent. Warning: Disconnect power supply before servicing. When servicing, use only identical replacement parts. Not suitable for use with flammable anaesthetics. Caution: Do not immerse in water. Please Note: When returning your nebuliser for servicing at Clement Clarke International please contact customer services for an authorized returns number. Please do not return your consumables when returning your nebuliser for servicing. The nebuliser case should be wiped clean with an alcohol wipe or similar, before returning for service. Please ensure wipe solution is compatible with ABS plastics.
7