HS CLEMENT CLARKE INTERNATIONAL

HS CLEMENT CLARKE INTERNATIONAL Nebulisers

AC2000, World Traveller, Econeb and Turboned 2 Operating Instruction issue 9 Jan 2012

Operating Instruction

2 Pages

12 Year Pack for AC2000 (2012) Adult Year pack (2012)... L3605125 Contents: as above but with no outlet filter. Child Year Pack (2012)... L3605124 Contents: as above but with child size face masks and no outlet filter.  Clement Clarke International Limited, Edinburgh Way, Harlow, Essex CM20 2TT UK Telephone: +44 (0)1279 414969 Fax: +44 (0)1279 456300 www.clement-clarke.com e-mail: resp@clement-clarke.com  Please note: All our masks are made from a strong plastic with anti-microbial and low static properties, and are phthalate free.  Catalogue no: 1902328 Issue no: 9 01/12  Year Pack for World Traveller, AC2000, Econoneb & Turboneb 2 Adult Year pack... L3605122 Contents: 4 nebuliser chambers, 4 drivelines, 4 adult face masks, 1 mouthpiece, 4 inlet filters and 1 outlet filter. Child Year Pack... L3605123 Contents: as above but with child size face masks. Items for Econoneb and Turboneb 2 Fuse Pack (2 x T1AL)... 3605534  62VA (260mA)  Power Consumption  64VA (270mA)  68VA (296mA)  Fuse  1 x T1AL 20mm long  Fuse  1 x T1AL 20mm long  1 x T1AL 20mm long  Nominal Flow  Min flow 7 L/min, Max flow 9 L/min @ 138 kPa*  Nominal Flow  Min flow 7 L/min, Max flow 9 L/min @ 138 kPa*  Min flow 9.5 L/min Max flow 10.5 L/min @ 138 kPa*  Weight  2.8 kg (without starter pack)  Weight  2.7 kg  2.7 kg  Dimensions  375mm x 235mm x 115mm  Dimensions  210mm x 185mm x 185mm  210mm x 185mm x 185mm  Type Rating  Class II BF Continuous  Type Rating  Sound Pressure Level  Class II BF Continuous  Class II BF Continuous  60 dbA approx.  Sound Pressure Level  63 dbA approx.  63 dbA approx.  0120 Purchase your nebuliser and consumables at: www.clement-clarke.com Please read these instructions before using the equipment  Refer to the colour coded pages, applicable to your machine  Econoneb Turboneb 2 Hi-Flo  AC2000 World Traveller Notes on Nebuliser Care Caution 1 Do not immerse machine in water. 2 Physician prescribed use only. 3 Never use more frequently than prescribed. 4 If therapy is having no effect, consult physician.  EMC (Electro Magnetic Compatibility) Declaration With the increased number of electronic devices such as PC’s and mobiles, medical devices in use may be susceptible to electromagnetic interference from these devices. Which may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC with the aim to prevent unsafe product situations, the EN60601-1-2 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.  Cleaning In order that you benefit fully from your equipment, it is important that the machine and accessories are kept in a clean condition. Ensure that the medication chamber is taken apart and washed in warm soapy water. Rinse and allow to dry after each use. The jet holes should be blown clear by attaching the chamber to the air outlet from the compressor and running the machine for a couple of minutes. We advise that the tube is disconnected from both the outlet filter and the chamber after each use to prolong the life of the connector.  Replacement It is recommended that the following disposable items should be changed as follows: Nebuliser chamber Inlet filter Driveline Face mask  Troubleshooting If the green light in the mains switch is on, yet the motor does not function, there is an internal fault. The machine should be returned to the point of purchase or an authorised person for examination. If the green light(s) on the switches are off:  Air compressor will not operate when switched on.  Action  Problem  1. Check mains lead is securely connected each end. 2. For machines with a 3 pin plug (UK) remove and check the fuse in the plug. Fuse - 3.15AL 25mm long. 3. Check mains fuse in the control panel. AC2000 & World Traveller fuse - T1AL 20mm long. 4. If battery/pump switch light is off (World Traveller only), check DC fuse in control panel. Fuse - T5AL 20mm long. 5. Disconnect unit from electricity supply. Check mains fuse in the mains inlet socket.  Medical devices manufactured by Clement Clarke International Ltd conform to this EN60601-1-2 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: The use of accessories and cables other than those specified by Clement Clarke Int. Ltd, with the exception of cables sold by Clement Clarke International Ltd. as replacement parts for internal components, may result in increased emission or decreased immunity of the device. The medical devices should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is unavoidable, the medical device should be seen to operate normally as it should in this situation. Further guidance regarding the EMC environment (in accordance with EN60601-1-2) in which the device should be used is available at www.clement-clarke.com/ medicalquality  Guarantee This guarantee is offered to you as an extra benefit and does not affect your statutory rights.  change every 3 months  CCI products are carefully designed, manufactured and inspected. CCI undertake to replace or repair any part found to be defective in material or workmanship subject to the following terms and conditions:  } change every 12 months  Mouthpiece Outlet filter  Only nebuliser chambers supplied or approved by CCI should be used.  Storage  AC (mains) Min flow 7 L/min, Max flow 8.5 L/min @ 138 kPa* DC (battery) Min flow 6.5 L/min, Max flow 8.5 L/min @ 138 kPa*  Power Consumption  Operating Instructions for the following four nebuliser systems The machine should be stored in a dust and smoke-free area.  Nominal Flow  230V / 50Hz  Recommended:  T1AL 20mm long, T5AL 20mm long, T3.15AL 20mm long (rechargeable battery pack fuse)  220V-240V / 50Hz  0˚c - 40˚c RH: 15% - 95% Pressure: 950hPa - 1020hPa  60 dbA approx.  Fuse  Operating Voltage  The compressor/motor, excluding serviceable parts, are guaranteed for three years on condition that: the unit is serviced every 12 months for the first three years. cleaned and maintained in accordance with the instructions. servicing is undertaken by CCI approved engineers/agents. only CCI approved parts may be used to service this equipment. Where a rechargeable battery is supplied, a three months guarantee applies.  Safety Precautions  Sound Pressure Level  80VA 350mA-700mA~or 3.0A 220V-240V / 50Hz  ∗ Always disconnect from electricity supply before undertaking any maintenance or cleaning.  Class II BF Intermittent (use for 60 mins; do not reuse within 60 mins) 50-60Hz  Power Consumption Operating Voltage  Should this happen, switch off at mains and unplug immediately.  Type Rating Frequency  UK/EU  ∗ Never operate the unit where it may come into contact with water.  375mm x 235mm x 115mm 110-240V~ or 12V  UK/EU  fibres can be drawn into the unit when in use.  Dimensions Operating Voltage  Items for World Traveller Part no. Fuse pack for World Traveller (2 x T1AL, 1 x T5AL, 1 x T3.15AL) 3605535 DC cigar lighter lead... 3605667 Rechargeable battery pack... 3605290 Shoulder bag... 3607691 Items for AC2000 Fuse Pack (2 x T1AL)... 3605534 Shoulder bag... 3607691 Country  Turboneb 2  ∗ Never block air intake grills on the carrying case. ∗ Always keep electrical leads clear of heated surfaces. ∗ Position the unit on a clean surface. Do not place on carpet where  11 denotes AC denotes DC Without battery 2.8 kg With battery 3.6 kg Worldwide  World Traveller Hi-Flo UK/EU  Econoneb  Technical Specifications - cont. ∗ Avoid using in a room where people smoke. ∗ Store in a clean, dry, dust free environment at room temperature. ∗ Not suitable for use with flammable anaesthetic gases. ∗ Do not modify the equipment or its accessories in any way. ∗ Do not allow liquid to enter the mains input socket.  ~  Weight Country  Spares and Accessories *1 kPa = 0.01bar or 0.145psi Country  AC2000  Technical Specifications  This guarantee does not apply to: The disposable nebuliser chamber, driveline, face mask, mouthpiece and filters. Defects arising from misuse, negligence, improper maintentance, accident, damage in shipment or unauthorised modification or service. Regular servicing at 12 monthly intervals. To register this guarantee please return the card, supplied with this handbook, within 15 days of purchase. CCI shall not be liable for any third party or consequential loss or damage of whatever nature arising from or in connection with this equipment. Should it become necessary to make a claim under guarantee, return the unit properly packed (preferably in the original packaging) to the point of purchase (the manufacturer, shop, distributor or outlet where the device was purchased). Please include name and address, details of problem and proof of date of purchase (please retain original invoice). Carriage costs to be paid by the customer.  8  1. Check inlet filter. Replace if necessary. 2. Wash nebuliser chamber. Replace if problem still occurs. 3. Check driveline tubing is not kinked or leaking. Replace if necessary. 4. Service compressor.  Nebuliser chamber bubbles or produces little or no mist.  1. Check battery/pump switch is on and illuminates. 2. Check the rechargeable battery pack fuse. Fuse - T3.15AL 20mm long. 3. If the low battery indicator is on, recharge battery for 16 hours maximum.  World Traveller will not operate from the rechargeable battery pack  1. Check battery/pump switch is on. 2. Check cigar lighter lead is clean and working. 3. Check the DC fuse in the control panel. Fuse - T5AL 20mm long. 4. Check the soldered connections on the plug and the cigar lighter adaptor on the lead.  World Traveller will not operate from the cigar lighter lead.  Time taken to nebulise significantly increases.  Disposal Instructions All Nebulisers, including batteries where applicable, should NOT be disposed of with household waste as they are not bio-degradable in landfill sites. They should NOT be incinerated. For safe disposal take to: The local (council/authority) environmental waste site, (in accordance with the European Environmental directive). For details contact your local authority/recycling centre. IMPORTANT The wires of the mains lead wires are coloured in accordance with the following code: Blue - Neutral Brown - Live As these colours may not correspond to the coloured markings sometimes used to identify the terminals in a plug, proceed as follows: Connect the Blue wire to the terminal marked N or coloured black. Connect the Brown wire to the terminal marked L or coloured red. NB Neither wire should be connected to the earth pin marked E or coloured green or yellow and green.  9  10
File Type: PDF
File Size: 1.46 MB
File Name: HS CLEMENT CLARKE INTERNATIONAL - AC2000, World Traveller, Econeb and Turboned 2 Operating Instruction issue 9 Jan 2012 - 2012-01.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions