Integra LifeSciences Corporation

Camino Model CAM01 Directions for Use Issue 2

Directions for Use

8 Pages

SPECIFICATIONS CAMINO ADVANCED MONITOR WITH WAVEFORM DISPLAY, Model CAM01 Pressure Sensor Type Pressure Measurement Range (ICP) High ICP Alarm Low CPP Alarm Temperature Sensor Type Temperature Measurement Range Mean Cerebral Perfusion Pressure (CPP) Range Linearity and Hysteresis Reference Pressure Display  Analog Output RS232 Use  External Monitor Output External Monitor Input (Arterial Pressure) Battery Type Charge Time Operation Time Operating Temperature Operating Pressure Operating Humidity Shipping/Storage Temperature Shipping/Storage Pressure Shipping/Storage Humidity Power Requirement Dimensions Class of Equipment (IEC 60601-1) Protection Against Fluids (IEC 60601-1) Mode of Operation Weight  Fiberoptic pressure transducer -10 to +250 mmHg pressure, Resolution of 1 mmHg 0 to 250 mmHg, 1 mmHg increments 0 to 150 mmHg, 1 mmHg increments Thermistor transducer 16.7¡C to 42.2¡C (65¡F to 108¡F), Accuracy of –0.3¡ C (0.5¡F) 0 to 200 mmHg, Resolution of 1 mmHg  CAMINO  See individual Catheter specifications Atmospheric Backlit TFT active matrix LCD panel display of pressure waveform, numeric pressure, cerebral perfusion pressure, temperature, systolic and diastolic values 1V/100 mmHg Data acquisition may be accomplished using the SERIAL DATA CAPTURE program, PN MPM-1-SDC. For details contact Integra NeuroSciences. 5 V/V/ mmHg 1V/100 mmHg Rechargeable, sealed lead acid 8-10 hours to full charge 1-2 hour from full charge 15¡C to 40¡C 700 hPa to 1060 hPa 20% to 95% RH 0¡C to 50¡C 500 hPa to 1060 hPa 20% RH to 95% RH non-condensing 100-230 V, 50/60 Hz, 50 VA 335 mm H x 240 mm W x 115 mm D (12.9" x9.4" x 4.5") Class 1 Ordinary Continuous 5.0 kg (11.0 lbs.)  CE Mark obtained 1998  INTEGRA NEUROSCIENCES 311 ENTERPRISE DR. PLAINSBORO, NJ 08536 USA. (800) 654-2873, (609) 275-0500 FAX (609) 275-5363  Integra NeuroSciences Newbury Road Andover Hampshire SP10 4DR England Phone: +44 (0) 1264 345 700 Fax: +44 (0) 1264 332 113  3 000 R 700 ISS 2  CAMINO ADVANCED MONITOR WITH WAVEFORM DISPLAY MODEL CAM01  DIRECTIONS FOR USE  CAUTION: FEDERAL (U.S.A.) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN.  Read carefully prior to use
File Type: PDF
File Size: 236 KB
File Name: Integra LifeSciences Corporation - Camino Model CAM01 Directions for Use Issue 2.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions