Integra LifeSciences Corporation
MAYFIELD Patient Positioning For Success Guide
Guide
1 Page
Preview
Page 1
MAYFIELD®
Patient Positioning For Success Approach*
Skull Clamp Positioning
Upper lateral suboccipital. Head is maintained in 0-degrees of rotation (“Park Bench” position).
Access to Cerebellopontine angle and the lateral brainstem.
“Sweatband” = Stability
Skull Clamp Application
Limit uncertainty when positioning the MAYFIELD® Skull Clamp to the patient’s head, visualize a sweatband on the patient. The skull pins should be applied within the area covered by the sweatband.
Single pin side superior. Head resting on 2-pin rocker arm of skull clamp.
Approach* Posterior, parietal, occipital.
Access to Exposure to parietal and occipital lobes.
Skull Clamp Application Equal Forces = Stability Unequal Forces = Unstability
Skull clamp is applied parallel to the floor.
If the two skull pins on the rocker are equidistant from the center line, then the forces on these pins will be equal and stable.
If the two skull pins on the rocker are not equidistant from the center line, the forces on these two pins will not be equal and could be unstable. MAYFIELD Ultra Base Unit A2101
Approach*
MAYFIELD Swivel Adaptor A1018
Pterional, frontal, temporal and parietal approaches.
Access to
MAYFIELD Triad Skull Clamp A1108
Frontal, parietal, and temporal regions.
MAYFIELD Disposable Skull Pins A1072
Skull Clamp
MAYFIELD Ultra Base Unit A2101
Single pin side superior. Head resting on 2-pin rocker arm of skull clamp.
MAYFIELD Ball Socket Swivel Adaptor A1064 MAYFIELD Adult Horseshoe Headrest A1012 Posterior Cervical Spine Support A1073
*Patient position and application of the skull clamp can be made with numerous variations. The patient’s final position should be acceptable to the surgeon, taking into account the patient’s anatomy, pressure points, neck flexibility and access to the surgical target.
MAYFIELD XR2 Base Unit A2079 MAYFIELD Infinity XR2 Skull Clamp A2114 For more information or to place an order, please contact: United States, Canada, Asia, Pacific, Latin America USA 800-654-2873 888-980-7742 fax International +1 609-936-5400 +1 609-750-4259 fax integralife.com/contact n
n
Manufacturer: Integra LifeSciences Corporation 4900 Charlemar Drive, Bldg. A Cincinnati, OH 45227 USA n
MAYFIELD is a registered trademark of SM USA, Inc. and is used by Integra under license. Integra and the Integra logo are registered trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States and/or other countries. ©2015 Integra LifeSciences Corporation. All rights reserved. Printed in USA. 0334165-1-EN