KCI

Acti V.A.C Therapy System Alarm Troubleshooting Guide

Alarm Troubleshooting Guide

2 Pages

ActiV.A.C. Therapy System Alarm Troubleshooting ®  Quick reference for the delivery of prescribed therapy.  Customers needing technical assistance, please call KCI at 1-800-275-4524 to troubleshoot in real-time over the phone 24 hours a day.  Detecting and resolving common ActiV.A.C.® Therapy alarms. To be used in conjunction with device User Manual.* System Alarm  Alarm Condition  Canister Full Alarm  Unit has detected the canister is full and should be replaced despite minimal amounts of fluid in canister  Action/Resolution • Change ActiV.A.C.® canister  User Tips • Avoid placing ActiV.A.C.® into carrying bag with canister pointing upwards. Unit should be worn or hung so that touchscreen is visible in window • Avoid placing therapy unit upside down (with touchscreen facing down) for prolonged periods of time  • Check tubing for closed clamps, kinks, crimps or blockages  • Ensure a quarter-sized (2.5cm) hole has been cut in the drape  Blockage Alarm  Unit has determined that blockage is present  Leakage Alarm  Unit has detected a significant negative pressure leak which has not been resolved. If this alarm is not resolved within 3 minutes, therapy will stop  • Use leak detection procedures and the Seal Check™ tool, as discussed in the Quick Reference Guide which accompanies this device, to help find and resolve leak  • For larger, highly exudating wounds, adjust intensity level to highest level to ensure a faster draw down. Default setting is low intensity  Battery Critical Alarm  Alarm indicating 30 minutes of battery power remaining  • Immediately recharge battery  • Charge ActiV.A.C.® Therapy Unit at least twice a day  Low Pressure Alarm – Therapy Interrupted  Unit indicates negative pressure at wound may be below set pressure, potentially compromising therapeutic benefits  • Inspect to ensure a quarter-sized (2.5cm) • Ensure SensaT.R.A.C.™ pad is located in a hole has been cut in the drape flat area of the body, avoiding a skin fold • Ensure dressing and drape have not • Avoid the additional use and application of ™ shifted and blocked SensaT.R.A.C. Pad adhesive tape on or over SensaT.R.A.C.™ Pad outer lumens  • Ensure power cord is securely connected to therapy unit  • Address dressing leak alarms as quickly as possible to avoid a drain on the unit’s battery  • Check tubing for closed clamps, kinks, crimps or blockages  • Lower therapy unit and tubing to or below wound level  • Ensure dressing and drape have not shifted and blocked SensaT.R.A.C.™ Pad outer lumens  • Ensure a quarter-sized (2.5cm) hole has been cut in the dressing where the SensaT.R.A.C.™ Pad is placed  Charging Cord Connector  Therapy unit and tubing should be at or lower than wound surface
File Type: PDF
File Size: 2.37 MB
File Name: KCI - Acti V.A.C Therapy System Alarm Troubleshooting Guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions