ABThera OA NPT System Tip Sheet Jan 2010

Tip Sheet

5 Pages

ABThera™ Open Abdomen Negative Pressure Therapy (OA NPT) System  Tip Sheet, FAQ, and System Specifications  ABThera™ OA NPT System Tip Sheet •  System/Unit The power button should be held for two seconds to activate the unit and three seconds to deactivate it.  •  A full canister condition triggers the blockage alarm on the unit. Under this condition, the canister lid filter becomes occluded, triggering the alarm. Both the canister and lid should be replaced.  •  Ensure customers understand how to connect the tubing set to the canister correctly. Connecting the tubing set incorrectly could cause system-related issues. The canister connectors (on the tubing set) are marked with “patient” and “vacuum” symbols to match the port markings on the canister lid. Additionally, the “patient” tubing set connector has a tethered cap that can be used as an additional point of reference. The tethered cap must be removed from the tubing lumen before connecting to the canister lid. Please see Figure 1 for additional guidance.  Dressing  Figure 1. Connecting the tubing set to the canister  •  The tubing set is designed to be used with the ABThera™ Unit ONLY (this information is also presented in the IFU document). Using the tubing set with any other negative pressure source could cause system-related issues such as blockages or unit failure.  •  Observing dressing draw down and fluid removal during the first three minutes of pump operation is an excellent way to ensure a seal has been established. If a leak does exist, the Leak Alarm will be triggered five minutes after power is turned on. Canister The ABThera™ System has been verified and validated for use with the ABThera™ Canister ONLY (Part # 370620). Using other types of canisters could lead to system issues. Canisters are designed for single use ONLY (this information is also presented in the IFU document). Reusing canisters can significantly impair pump performance through the creation of blockages and other potential issues.  •  •  When troubleshooting leak alarms, the canister should first be inspected to ensure a proper lid seal and absence of hairline cracks (visual inspection of canister is recommended prior to use). The Dressing should be addressed after the canister to minimize the need for additional dressings.  •  Stocking canisters in all potential patient holding areas has been recognized as a best practice. This inventory approach ensures the availability of canisters when needed and minimizes any disruptions to patient therapy.  DSL#10-0029 (01/10)CONFIDENTIAL. For KCI internal training use only. Do not copy. Do not distribute outside KCI. Page 1
File Type: PDF
File Size: 168 KB
File Name: KCI - ABThera OA NPT System Tip Sheet Jan 2010 - 2010-01.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions