KONICA MINOLTA

MD300C5 Finger Pulse Oximeter Information Manual

Information Manual

3 Pages

of the Oximeter might be influenced. 5.5 The product will automatically be powered off when no signal is in the product for longer than 8 seconds. 5.6 PR tone modulation 5.7 Brightness adjustment  Information Manual  6. Product Intended Use  Version: FDA 1.0C5 Fingertip Pulse Oximeter  MD300C5  1.Measurement principle The oximeter is calibrated to display functional oxygen saturation. Principle of the Oximeter is as follows: An experience formula of data process is established taking use of Lambert Beer Law according to Spectrum Absorption Characteristics of Reductive hemoglobin(R Hb) and Oxyhemoglobin (O2 Hb) in glow and near-infrared zones. Operation principle of the instrument is Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning and Recording Technology, so that two beams of different wavelength of lights (660nm glow and 940nm near infrared light) can be focused onto human nail tip through perspective clamp finger-type sensor. Then measured signal can be obtained by a photosensitive element, information acquired through which will be shown on two groups of LEDs through process in electronic circuits and microprocessor.  2.Precautions for use Operation of MD300C5 may be affected by the use of an electrosurgical unit (ESU). The MD300C5 must be able to measure the pulse properly to obtain an accurate SpO2 measurement. Verify that nothing is hindering the pulse measurement before replying on the SpO2 measurement. l Do not use the MD300C5 in an MRI or CT environment l Do not use the MD300C5 in situations where alarms are required. The device has no alarms. l Explosion hazard: Do not use the MD300C5 in an explosive atmosphere. l The MD300C5 is intended only as an adjunct in patient assessment. It must be used in conjunction with other methods of assessing clinical signs and symptoms. l Check the pulse oximeter sensor application site frequently to determine the positioning of the sensor and circulation and skin sensitivity of the patient. l Do not stretch the adhesive tape while applying the pulse oximeter sensor. This may cause inaccurate readings or skin blisters. l Before use, carefully read the manual. l The MD300C5 has no SpO2 alarms, it is not for continuous monitoring, as indicated by the symbol. l Prolonged use or the patient’s condition may require changing the sensor site periodically. Change sensor site and check skin integrity, circulatory status, and correct alignment at least every 4 hours.  l l  Intended Use: Fingertip Pulse Oximeter MD300C5 is a portable non-invasive, spot-check, oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult and pediatric patient at home, and hospital (including clinical use in internist/surgery, Anesthesia, intensive care and etc). Not for continuously monitoring. The MD300C5 requires no routine calibration or maintenance other than replacement of batteries.  7. Operation Instructions 7.1 Installing two AAA batteries into battery cassette before covering its cover. 7.2 Open the clamp as illustrated in the picture below 7.3 Plug one of fingers into rubber hole of the Oximeter (it is best to plug the finger thoroughly) before releasing the clamp 7.4 Press the switch button once on front panel. 7.5 Your finger do not tremble during the Oximeter is working. Your body is not recommended in moving status 7.6 Read correspondent datum from display screen. 7.7 Six display modes After turn on the oximeter, each time you press the power switch, the oximeter will switch to another display mode, there are 6 display modes shown as follows Display Mode  Description Display mode when opening horizontal and normal facing  the  device,  After 1 click, the display is horizontal but handstand facing  After 1 click again, the display is vertical and handstand facing  3.Inaccurate measurements may be caused by Do not sterilize the device using autoclaving, ethylene oxide sterilizing, or immersing the sensors in liquid which may cause inaccurate readings. The device is not intended for sterilization. l Significant levels of dysfunctional hemoglobins (such as carbonxy- hemoglobin or methemoglobin) l Intravascular dyes such as indocyanine green or methylene blue l SpO2 measurements may be adversely affected in the presence of high ambient light. Shield the sensor area (with a surgical towel, or direct sunlight, for example) if necessary. l Excessive patient movement l High-frequency electrosurgical interference and defibrillators l Venous pulsations l Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line l The patient has hypotension, severe vasoconstriction, severe anemia, or hypothermia l The patient is in cardiac arrest or is in shock l Fingernail polish or false fingernails may cause inaccurate SpO2 readings. l Follow local ordinances and recycling instructions regarding disposal or recycling of the device and device components, including batteries. 4.Technical Specifications 4.1 Display type: LCD display SPO2 display range: 0-100% PR display range: 30-235 BPM PR display mode: bargraph Data update time: < 15 s l  4.2 LED Wavelengths Red: 660nm Infrared: 940nm 4.3 Battery life Two AAA 1.5V alkaline batteries could be continuously operated as long as 30 hours.  After another click, the display is vertical and normal facing  After another click again, the display is horizontal and normal facing with wave-shape filled form display  After 1 click once more, the display is horizontal and normal facing with wave-shape wire form display  When you press the power switch for a long time (more than one second), the brightness of the oximeter will be changed by degrees, there are 10 levels on brightness; the default level is level four. When your finger is plugged into the Oximeter, your nail surface must be upward.  4.4 Resolution: ±1% for SPO2 and ±1BPM for Pulse rate 4.5 Measurement Accuracy: SPO2: 70%--100%, ±3%; ≤70% no definition. PR: 30-235 BPM, ± 2 bpm during the pulse rate range of 30-99 bpm and 2% during the pulse rate range of 100-235 bpm  8. Brief Description of Front Panel Low power indicator  4.6 It is equipped with a function switch, through which the Oximeter can be powered off in case no finger is the Oximeter longer than 8 seconds. 4.7 Outline dimension: Length: 50mm Width: 28mm Height: 28mm Weight: 25g (without two AAA batteries) 4.8 Environment requirements: Operation Temperature: 5-40℃ Storage Temperature: -20-70℃ Humidity : 15%-80% in operation <93% in storage Declaration: EMC of this product comply with IEC60601-1-2 standard.  5.Product Properties 5.1 Operation of the product is simple and convenient 5.2 The product is small in volume, light in weight (total weight is about 50g including batteries) and convenient in carrying 5.3 Power consumption of the product is low and the two originally-equipped two AAA batteries can be operated continuously for 30 hours. 5.4 Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation  PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn  Power switch  PR Bargraph  SPO2 waveform SpO2 Patient pulse rhythm is indicated as such by bar graph.  9.Product Accessories 9.1 One hang lace 9.2 Two batteries 9.3 One instruction manual  10.Battery Installations 10.1 Put the two AAA batteries into battery cassette in correct polarities. 10.2 Push the battery cover horizontally along the arrow shown as below:  Pulse Rate
File Type: PDF
File Size: 104 KB
File Name: KONICA MINOLTA - MD300C5 Finger Pulse Oximeter Information Manual.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions