Laerdal Medical
AED Trainer 3 Directions for Use Rev B June 2012
Directions for Use
138 Pages
Preview
Page 1
AED Trainer 3 Directions for Use
English 日本語 Française Deutsch Español Italiano
www.laerdal.com
1 EN Laerdal AED Trainer 3 DFU.indd 1
08.06.12 09:59
AED TRAINER 3 USER INTERFACE
A B
G H
C
K D I E
A. Training Pads Connector Socket - Receptacle for the training pads connector plug.
B. Pads Connector LED - Flashes to indicate the socket location when device is turned on. Inserted pads connector plug covers the LED, which stops flashing when connector plug is properly seated. C. Remote Control Receiver Window - Receives signals from the optional remote control.
D. Speaker - Delivers voice instructions from the AED Trainer 3. Speaker volume can be adjusted with the remote control or set in the device configuration.
E. Connector - For future use. F. Green Ready Light - Illuminates when the AED Trainer 3 is turned on; flashes when device is receiving commands from the remote control; stays off when the device is not in use.
J
G. Infant/Child Key Port - Receptacle for the Training Infant/Child Key. When Key is inserted, the AED Trainer 3 operates in Infant/Child mode to simulate defibrillation of an infant or child under 8 years old or 25 kg (55 lbs).
H. Green On/Off Button - Turns on the AED Trainer 3 and starts voice instructions.
I. Orange Shock Button - Controls delivery of simulated shock. The button flashes when a shock is advised during a scenario.
J. Battery Compartment - Contains the four replaceable AA size alkaline batteries used to power the AED Trainer 3.
K. Operating System Card - Contains the Trainer operating system, all voice commands, and device configuration. The Operating System Card must be installed in the AED Trainer 3 to use the device.
3
1 EN Laerdal AED Trainer 3 DFU.indd 3
08.06.12 09:59
Directions for use (English) 5 日本語 26 Française 48 Deutsch 70 Español 92 Italiano 114
Visit http://www.laerdal.com for multi-language DFU.
1 EN Laerdal AED Trainer 3 DFU.indd 4
08.06.12 09:59
Contents Introduction Description and Intended use
6
Features
6
How supplied Standard Package Contents
7
Optional Accessories
7
Setting up the AED Trainer 3 Checking the Operating System Card
8
Installing the Batteries
8
Selecting a Language
9
Changing the Configuration
10
Connecting the Training Pads
11
Accessing the Training Infant/Child Key
13
Using the AED Trainer 3 Preparing to Use the Trainer
14
Selecting a Training Scenario
16
Running a Training Scenario
16
Using the Optional Remote Control
16
Appendices Parameter Settings
18
Training Scenarios
20
Remote Control
22
Troubleshooting Tips
23
Specifications
24
Regulatory Information
25
Glossary of Symbols
25
1 EN Laerdal AED Trainer 3 DFU.indd 5
08.06.12 09:59
INTRODUCTION
Introduction DESCRIPTION AND INTENDED USE The AED Trainer 3 is designed to prepare emergency responders to use the HeartStart FR3 automatic external defibrillator (AED) and other AEDs. Together with appropriate manikins, the AED Trainer 3 is intended to give realistic training on delivering correct treatment, including shock delivery and CPR, to a cardiac arrest victim. The AED Trainer 3 provides eight training scenarios that simulate realistic episodes of sudden cardiac arrest (SCA) and help responders become familiar with use of the HeartStart FR3 AED in an emergency. These scenarios are compatible with training programs developed by internationally recognized responder programs. The AED Trainer 3 is shipped with a factory default setup that complies with the ERC (European Resuscitation Council) and AHA (American Heart Association) 2010 Guidelines.The device may also be configured to conform to local protocols or Guideline Updates. Note: Before using the HeartStart FR3 Defibrillator, the responder should have completed an appropriate responder training program, which may include the use of the AED Trainer 3. Having completed such a course, the responder should demonstrate a proficiency in assessing the patient for lack of responsiveness and absence of breathing, cardiopulmonary resuscitation (CPR), and knowledge of applicable medical protocols and procedures. FEATURES The AED Trainer 3 is designed to replicate the operation of the HeartStart FR3 AED. However, it has no high-voltage capabilities, ensuring safety during training. It provides simulated shock delivery. The AED Trainer 3 can be used to provide training on the following key features of the HeartStart FR3 AED: •
Fast delivery of therapy. The AED Trainer 3 carry case duplicates the auto-on feature of the FR3 carry case. When the case is opened, the AED Trainer 3 automatically turns on.
•
Pre-connected pads. Like the FR3 AED, the AED Trainer 3 uses pre-connected pads to help optimize response time.
•
Infant/Child Key. The AED Trainer 3 comes with a Training Infant/Child Key to replicate the infant/child mode of the FR3 AED.
•
Voice prompts. The AED Trainer 3 guides you through each step of the training scenario with the same voice prompts as the FR3 AED.
•
Extensive configurability. Like the FR3 AED, the AED Trainer 3 configuration can be customized and its operation easily updated as needed. Note: The Training Infant/Child Key cannot be used with the HeartStart FR3 AED. An FR3 Infant/Child Key is required for use with the AED.
6
1 EN Laerdal AED Trainer 3 DFU.indd 6
08.06.12 09:59
Items included
How supplied STANDARD PACKAGE CONTENTS The AED Trainer 3 is shipped with the following items as standard: TRAINING
•
one AED Trainer 3
•
one Carry Case
•
one Training Infant/Child Key pre-installed on tether in carry case.
•
one External Manikin Adapter
•
one pre-installed AED Trainer 3 Operating System Card containing the AED Trainer 3 operating system
•
one reusable HeartStart Training Pads III interconnect cable
•
one set of reusable HeartStart Training Pads III
•
one printed Instructions for Use in English and Japanese
•
one multi-language Quick Start Guide
•
one set of “Training Only” stickers in multiple languages
•
4 AA size alkaline batteries (not shown)
AED Trainer 3
R
T FO NO ICAL IN CL
TRAINING
Philips Training Pads III
E
US
Reusable Training Pads III Interconnect cable
Training infant/child key
Operating System Card
Optional ACCESSORIES The following accessories are available separately for use with the AED Trainer 3: •
Remote Control, with one replaceable lithium CR2025 3V battery [REF: 198-00350]
•
Replacement Carry Case for AED Trainer 3 [REF: 198-10050]
•
Replacement Instructions for Use printed in English and Japanese [REF: 20-02971]
•
Replacement AED Trainer 3 Operating System Card [REF: 198-10250]
•
Replacement HeartStart Training Pads III Interconnect Cable [REF: 989803150201]
•
Replacement HeartStart Training Pads III [REF: 989803150181]
•
Replacement External Manikin Adapters, set of 5 [REF: M5089A]
•
Laerdal LINK Technology Training Pads [REF: 945090]
Carry Case
7
1 EN Laerdal AED Trainer 3 DFU.indd 7
08.06.12 09:59
SETUP
Setting up the AED Trainer 3 To set up the AED Trainer 3 for operation, you will need to ensure that the Operating System Card is properly installed, install the batteries, select a different language if you do not wish to use U.S. English, and connect the training pads. Instructions for each of these tasks follow. CHECKING THE OPERATING SYSTEM CARD The AED Trainer 3 Operating System Card contains the operating system for the AED Trainer 3. The AED Trainer 3 is shipped with the Operating System Card pre-installed. To remove, re-install, or replace the Operating System Card, follow the steps below: 1
Squeeze the latch on the battery compartment lid to release the lid. Lift out the lid and set it aside.
2
Check that the Operating System Card is installed in the slot at the top of the compartment. If not, install the Operating System Card in the orientation shown.
INSTALLING THE BATTERIES The AED Trainer 3 requires four AA size alkaline batteries. To install or replace the batteries in the AED Trainer 3, follow the steps below: 1
Squeeze the latch on the battery compartment lid to release the lid. Lift out the lid and set it aside.
2
Install four AA size alkaline batteries in the battery compartment oriented as illustrated inside the compartment. Note: Use only fresh batteries of the same type.
3
Replace the battery compartment lid.
4
Return the AED Trainer 3 to its case.
8
1 EN Laerdal AED Trainer 3 DFU.indd 8
08.06.12 09:59
SETUP SELECTING A LANGUAGE The default language of the AED Trainer 3 is U.S. English. To set up the AED Trainer 3 for another language, follow the steps below. 1
Press and hold both the green On/Off button and the orange Shock button for about six seconds. The AED Trainer 3 announces the default language “US English”.
2
Release both buttons.
3
Press and hold the orange shock button to scroll through each available language. The AED Trainer 3 announces each new language.
4
When the desired language is announced, press the green On/Off button to turn off the AED Trainer 3 and store the selected language. The AED Trainer 3 will use this language when it is next turned on.*
5
Apply the appropriate “Training Only” sticker for the language selected, as illustrated below.
* The AED Trainer 3 can be turned on by pressing either the on/off button or the shock button.
9
1 EN Laerdal AED Trainer 3 DFU.indd 9
08.06.12 09:59
SETUP CHANGING THE CONFIGURATION The AED Trainer 3 is shipped with a configuration replicating the default factory settings of the FR3 AED. If you want to change the AED Trainer 3 configuration to match local protocols or for other training purposes, follow the steps below: 1
Squeeze the latch on the battery compartment lid to release the lid. Lift out the lid and set it aside.
2
Remove the Operating System Card from the slot at the top of the compartment.
3
Insert the Operating System Card into the card slot of your computer or, if no slot is available, install the card into a standard card reader and connect it to your computer.
4
Open the AED Trainer 3 Configuration program and adjust the parameter settings as desired. See section: selecting a training scenario for detailed information about the available settings.
5
After making all desired changes, click on “Update.”
6
Click “Exit” to close the configuration program.
7
Remove the Operating System Card from the computer or card reader and replace it in the AED Trainer 3. See section: checking the operating system card for directions on installing the card. The AED Trainer 3 configuration will be updated automatically the next time the AED Trainer 3 is turned on.
10
1 EN Laerdal AED Trainer 3 DFU.indd 10
08.06.12 09:59
SETUP CONNECTING THE TRAINING PADS The AED Trainer 3 may be used with either HeartStart Training Pads III or Laerdal LINK Technology Training Pads. HEARTSTART TRAINING PADS III To connect the HeartStart Training Pads III to the AED Trainer 3, follow the steps below. 1
Remove the HeartStart Training Pads III from their storage bag, leaving them on their liner.
2
Remove the interconnect cable from its storage bag. Connect the pads cable to the interconnect cable.
G IN AIN
TR
G
IN
AIN TR
FOR E NOT AL US IC CLIN
3
Plug the interconnect cable’s yellow connector into the pads connector socket on the front of the AED Trainer 3. Be sure the connector clicks into place.
4
Place the AED Trainer 3 with the pre-connected pads in the carry case. The case is designed to store the AED Trainer 3 with the pads pre-connected.
The HeartStart Training Pads III are designed for up to 100 uses. To help ensure continued performance, avoid leaving the pads in heat or direct sunlight. To replace the pads, disconnect the connector plug from the AED Trainer 3 and repeat Steps 1 through 3, above.
11
1 EN Laerdal AED Trainer 3 DFU.indd 11
08.06.12 09:59
SETUP LAERDAL LINK TECHNOLOGY TRAINING PADS To connect the Laerdal LINK Technology Training Pads to the AED Trainer 3, follow the steps below. 1 Remove the Laerdal LINK Technology Training Pads from their storagebag, leaving them on their liner.
2
Plug the pads connector into the pads connector socket on the front of the AED Trainer 3. Be sure the connector clicks into place.
3
Place the AED Trainer 3 with the pre-connected pads in the carry case.The case is designed to store the AED Trainer 3 with the pads preconnected.
12
1 EN Laerdal AED Trainer 3 DFU.indd 12
08.06.12 09:59
SETUP Accessing THE TRAINING INFANT/CHILD KEY The Training Infant/Child Key is supplied on a tether cable pre-installed in the AED Trainer 3 carry case. To access the Training Infant/Child Key for use, remove it from its compartment in the case lid, and extend the tether to insert the key into the Infant/Child Key Port on the AED Trainer 3.
AED Tr
aine
1 5
2 6
3 7
r3
4 8
OK
Note: Do not store the Training Infant/Child Key installed in the AED Trainer 3. Install the Training Infant/Child Key in the AED Trainer 3 only when teaching defibrillation of infants or children under 8 years old or 55 lbs (25 kg).
13
1 EN Laerdal AED Trainer 3 DFU.indd 13
08.06.12 09:59
user instructions
Using the AED Trainer 3 PREPARING TO USE THE AED TRAINER 3 Before turning on the AED Trainer 3, follow the steps below: 1
Check that the pads are pre-connected as described, see section: Connecting the training pads. If no training pads are connected when the AED Trainer 3 is turned on, the AED Trainer 3 will provide a voice instruction to place the pads on the patient’s bare chest and then plug in the pads connector by the flashing light.
2
If you are using HeartStart Training Pads III, attach the external manikin adapter provided to the skin of the training manikin as shown below.
3
Place the pads on the adapter as shown.
1
2
AED Tr
1 5
2 6
ainer
3 7
3
4 8
OK
3
4
14
1 EN Laerdal AED Trainer 3 DFU.indd 14
08.06.12 09:59
user instructions
1
2
3
4
5
6
4
If you are using Laerdal LINK Technology Training Pads, use any Laerdal manikin equipped with Laerdal LINK Technology, such as Laerdal AED Resusci Anne or AED Little Anne. (The Laerdal LINK technology will indicate correct placement of the pads on the manikin.)
5
If you are training in infant/child defibrillation, insert the training Infant/Child Key in the port identified on the diagram on the inside front cover of this manual. The infant/child mode is intended for training in defibrillation of an infant or child under 8 years old or 55 lbs (25 kg).*
* The training Infant/Child Key should be kept with the AED Trainer 3, but not connected until you are ready to use the AED Trainer 3 in a pediatric scenario.
15
1 EN Laerdal AED Trainer 3 DFU.indd 15
08.06.12 09:59
user instructions SELECTING A TRAINING SCENARIO When you are ready to use the AED Trainer 3, follow the steps below: 1 Press and hold the green On/Off button for approximately six seconds. The AED Trainer 3 will announce “Training” and instruct you to press the orange shock button to select a training scenario. 2
Press the orange shock button as directed. The AED Trainer 3 announces the current training scenario number.
3
To select a different scenario, press and hold the orange shock button to scroll through each of the eight scenarios in sequence. The AED Trainer 3 announces each scenario number as it is reached. See section: Appendices for a detailed description of each scenario.
4
When you reach the desired scenario, press the On/Off button to turn off the AED Trainer 3 and store the scenario selection on the Operating System Card.The selected scenario will be active the next time the AED Trainer 3 is turned on. Note: The AED Trainer 3 automatically turns off automatically if it is inactive for ten minutes.
RUNNING A TRAINING SCENARIO To run a training scenario, press the On/Off button to turn on the AED Trainer 3, and following the AED Trainer 3’s voice instructions to simulate use of the FR3 AED in an emergency. For troubleshooting assistance, see section troubleshooting tips. 1
USING THE OPTIONAL REMOTE CONTROL If desired, the AED Trainer 3 can be used with an optional remote control that allows the instructor to select and override training scenarios.The remote control uses infrared light and requires a direct or indirect light path from the remote control to the receiver window on the AED Trainer 3. Do not cover the receiver window when using the remote control. The location of the receiver window is identified on the diagram on the inside front cover of this manual.
AED Trainer 3 1
2
3
4
5
6
7
8
OK
Note: If a direct line is blocked, pointing the remote control at the ceiling may provide a good indirect light path.
OK
For a description of the Remote Control operation, see Remote control. Note: The AED Trainer 3 can be configured for use with the AED Trainer 2 remote control, if desired. See section changing the configuration for directions on changing the configuration.
16
1 EN Laerdal AED Trainer 3 DFU.indd 16
08.06.12 09:59
Appendices Parameter Settings
18
Training Scenarios
20
Remote Control
22
Troubleshooting Tips
23
Specifications
24
Regulatory Information
25
Glossary of Symbols
25
1 EN Laerdal AED Trainer 3 DFU.indd 17
08.06.12 09:59
set parameters PARAMETER SETTINGS The following parameter settings are available in the AED Trainer 3. Default settings are shown in boldface.
Parameter
Settings
Description
Volume
loud, medium, soft
Sets the AED Trainer 3 speaker volume.
Shock Series
1, 2, 3, 4
Sets the number of shocks in a series that must be delivered before the AED Trainer 3 automatically activates a Basic CPR protocol.
Shock Series Interval (minutes)
1.0, 2.0, infinite
Sets the time interval used to determine if a delivered shock should be counted as part of the current shock series. This parameter applies only when the shock series setting is greater than 1.
Metronome
on, off
Enables (ON) and disables (OFF) audio beats for CPR compressions
AED Trainer 2 Remote Control
enable, disable
Enables or disables use of the AED Trainer 2 Remote Control rather than the AED Trainer 3 Remote Control.
Manikin LED
On, Off
Enables (On) or Disables (Off) the automatic illumination of the electrode pad LEDs in the Manikin Chest Skin indicating correct pad placement. When OFF the LEDs may only be illuminated using the remote control (Please note this function is only applicable when using Laerdal LINK electrodes and a Laerdal Link Manikin.)
Adult Basic CPR Duration (minutes)
1.0, 1.5, 2.0, 2.5, 3.0
Sets the length of the CPR protocol for adult Basic CPR.
Infant/Child Basic CPR Duration (minutes)
1.0, 1.5, 2.0, 2.5, 3.0
Sets the length of the CPR protocol for infant/child Basic CPR.
Adult NSA CPR Duration
1.0, 1.5, 2.0, 2.5, 3.0 minutes
Sets the length of the CPR protocol for adult Basic CPR.
Child NSA CPR Duration
1.0, 1.5, 2.0, 2.5, 3.0 minutes
Sets the length of the CPR protocol for infant/child Basic CPR
18
1 EN Laerdal AED Trainer 3 DFU.indd 18
08.06.12 09:59
set parameters
Parameter
Settings
Description
Adult CPR First Duration (minutes)
Parameter currently non-functional
Infant/child CPR First Duration (minutes)
Parameter currently non-functional
CPR Type
Parameter currently non-functional
Scenario
1, 2, 3, 4, 5, 6, 7,8
Sets the training scenario used when the AED Trainer 3 is turned on.
LINK Pads attachment tolerance
Slide Scale: Lower to Higher
Determines the required placement accuracy of training pads on a Laerdal LINK manikin. Lower tolerance equates to a more accurate pad placement requirement.
19
1 EN Laerdal AED Trainer 3 DFU.indd 19
08.06.12 09:59
Training scenarios Training scenarios To easily identify scenarios there is a pictorial scenario description label on the back of the AED Trainer 3. The symbols are defined below.
Symbol
Scenario Description Shockable rhythm detected by AED Trainer 3 Non-shockable rhythm detected by AED Trainer 3
Pads problem detected by AED Trainer 3 CPR First protocol initiated by AED Trainer 3
The following training scenarios are available for use with the AED Trainer 3:
Scenario
Symbol
1
Description • Shockable rhythm • One shock needed for conversion
One shock for conversion 2 One shock for conversion 3 Troubleshooting pads, one shock for conversion 4 Refibrillation after conversion
• Non-shockable rhythm • Non-shockable rhythm • Shockable rhythm • One shock needed for conversion • Non-shockable rhythm • Poor pads contact • Shockable rhythm • One shock needed for conversion • Non-shockable rhythm • Shockable rhythm • One shock needed for conversion • Non-shockable rhythm • Return to shockable rhythm after three minutes • One shock needed for conversion • Non-shockable rhythm
20
1 EN Laerdal AED Trainer 3 DFU.indd 20
08.06.12 09:59
Training scenarios
Scenario
Symbol
5
Description • Non-shockable rhythm throughout
Non-shockable rhythm 6 Two shocks for conversion 7 CPR first, one shock for conversion 8
• Shockable rhythm • Two shocks needed for conversion • Non-shockable rhythm • Shockable rhythm • CPR First • Shockable rhythm • One shock needed for conversion • Non-shockable rhythm • Shockable rhythm throughout
Shockable rhythm
21
1 EN Laerdal AED Trainer 3 DFU.indd 21