Laerdal Medical
Nursing Anne VitalSim and Nursing Anne Directions for Use Rev D
Directions for Use
84 Pages
Preview
Page 1
Nursing Anne VitalSim Nursing Kelly VitalSim NursingNursing Kelly VitalSim Anne Nursing KellyKelly Nursing Nursing Kelly
ENGLISH Directions for Use ENGLISH Directions for Use ESPAÑOL Instrucciones de Utilización ENGLISH Directionsdefor Use ESPAÑOL Instrucciones Utilización ITALIANO Instruzioni per l’Uso ESPAÑOL Instrucciones de utilización ITALIANO Instruzioni per l’Uso FRANÇAIS Mode d’Emploi ITALIANO Mode Instruzioni FRANÇAIS d’Emploi per l’Uso DEUTSCH Gebrauchsanweisung FRANÇAIS Gebrauchsanweisung Mode d’emploi DEUTSCH NEDERLANDS Handleiding DEUTSCH Handleiding Gebrauchsanweisung NEDERLANDS NORSK Bruksanvisning NEDERLANDSBruksanvisning Handleiding NORSK SVENSKA Bruksanvisning SUOMI Käyttöohje NORSK Bruksanvisning SVENSKA Bruksanvisning CHINESE SVENSKA Bruksanvisning SUOMI Käyttöohje JAPANESE SUOMI Käyttöohje CHINESE KOREAN CHINESE JAPANESE JAPANESE KOREAN KOREAN www.laerdal.com
www.laerdal.com www.laerdal.com
Table of Contents
Items Included: (1) Full-Body Female Manikin (1) Articulating Blood Pressure Training Arm (Nursing Anne VitalSim) (1) Articulating Female Multi-Venous IV Training Arm (1) Hospital Gown (1) Male Genitalia (1) Female Genitalia (3) Urinary Valves (3) Anal Valves (1) 10 foot Manikin Connector Cable (Nursing Anne VitalSim) (1) Simulated Blood Concentrate (1) 100 cc Syringe (1) Manikin Lubricant (1) Assembly Tool Kit
Items Included... 1 Skills Taught... 1 Teeth... 2 Carotid Pulse... 2 Tracheostomy Plug & Care... 2 NG Tube Placement... 2 Intubation... 2 Lungs... 2 Stomach Reservoir... 2 Belly Plates... 2 Injection Pads... 3 Waist, Knee and Ankle Joints... 3 Arms... 3 Legs... 3 IV Arm... 3 Replacing Skin & Vein System... 3 Blood Pressure Arm... 4 Auscultation of Heart, Breath, Bowel Sounds and Fetal Tones... 4 Genitalia... 4 Colon Reservoir... 5 Urinary Catheterization and Enema Simulation... 5 Troubleshooting... 5 Attaching Nursing Anne Modules to Manikin... 5 VitalSim Connection... 6 Care and Maintenance... 6 Replacement Parts... 6
Wig pictured on front cover, not included Optional Accessories Nursing Anne Modules: (1) Breast Exam Module, with interchangeable abnormalities (1) Mastectomy Module with staples and drain (1) Fundus Module with interchangeable uteri Wound Care & Assessment Set: (1) Abdominal Incision Module with Painted Sutures (1) Abdominal Incision Module with Staples and Penrose Drain (1) Abdominal Incision Module with Nylon Sutures and Penrose Drain (1) Abdominal Subcutaneous Heparin and Insulin Injection Module (1) Abdominal Packing Module (1) Infected Colostomy Stoma (1) Ventro-Gluteal and Gluteal Decubitus Ulcer Modules (1) Below Knee Amputation Stump (1) Thigh Packing and Irrigation Module (1) Thigh Suture Module (1) Thigh Debridement Module (1) Varicose Vein Leg with Stasis Ulcer (1) Diabetic Foot Module
Caution: Latex This product contains Natural Rubber latex which may cause allergic reactions when in contact with humans.
Skills Taught: • Basic patient handling • Denture care • Oral hygiene • Oral and nasal Intubation • Eye and ear irrigation (simulated) • NG Tube insertion, care medication administration and removal • Lavage/Gavage • Tracheostomy care and suctioning • Blood pressure skills (When used with VitalSim) • IV care and management • Subcutaneous and intramuscular injection • Oxygen delivery procedures • Ostomy irrigation and care • Catheterization skills • Enema simulation • Colonic irrigation • Wound assessment and care • Bandaging and dressing • Post-surgical mastectomy-care procedures • Recognition of breast disorders, their sizes and relative locations • Practice of fundus massage skills • Auscultation and recognition of normal and abnormal heart, breath and bowel sounds and fetal tones (When used with VitalSim)
Please contact Laerdal Customer Service for more information on Replacement Parts in other skin tones.
The product, when carrying the CE-mark, is in compliance with essential CE requirements and other relevant provisions of council directive 1999/5/EC.
Nursing Anne
English
English
1
Laerdal
Intubation – The following equipment is recommended:
Nursing Anne VitalSim Advanced is a full-body, lifelike vinyl manikin designed to teach all skills from basic patient handling to advanced nursing, including the measurement of noninvasive blood pressure and the auscultation and recognition of normal and abnormal heart, lung and bowel sounds and fetal tones.
a. Endotracheal tube, size 7.5 ID or smaller b. Manikin Lubricant or liquid soap c. 10 ml syringe d. Laryngoscope blade, size #2 or #3 straight or curved. e. Laryngoscope handle f. NG Tube, size 16 French
The manufacturing quality of this simulator should provide many sessions of training when reasonable care and maintenance are practiced.
Remove trach plug prior to insertion of intubation tubes.
Laerdal Recommends: Intubation tubes and airway passages should be sprayed with manikin lubricant or lubricated with liquid soap prior to intubation.
IV Injections – 22 gauge needle, or smaller Tracheostomy Tube – Size 6 NG Tube – Size 16 French Endotracheal Tube – 7.5 or smaller Laryngoscope Blade - Size #2 or #3, straight or curved blade Urethral Catheter – 16 French Enema Simulation – 7 mm
Lungs – Lungs may be removed from bronchial tubes by unscrewing them at the connector site. To replace, reverse procedure. Stomach Reservoir – Stomach reservoir attaches to esophagus with a connector. To fill reservoir with water, use 100 cc syringe.
Teeth – To remove: Grasp firmly and lift.
Dusting with talcum powder is helpful in replacing belly plates.
Insert and remove bottom teeth first when performing denture care. To reinsert both sets: a. Begin on one side and work around, aligning ridges with corresponding grooves in jaws. (Dusting with baby powder is helpful.) b. Press firmly into place.
Belly Plate with Multi-Sounds – To remove: 1. Apply pressure to center of plate. 2. Work your fingers under edge of plate while lifting. 3. Disconnect bowel sound speaker connector to release plate.
Carotid Pulse – To generate a carotid pulse, use the hand held red bulb located on the right axillary side of manikin. Firmly squeeze bulb while palpating for pulse at carotid site.
To insert: 1. Position plate over cavity. 2. Reconnect bowel sound speaker. 3. Work plate edges into groove on pelvis cavity.
Tracheostomy Plug – The tracheostomy plug may be removed by grasping firmly, then lifting up and out. To replace, press into hole. (Photo 1)
Belly Plate with Colostomy Stoma – To remove: 1. Apply pressure to center of plate. 2. Work fingers under edge while lifting. (Photo 2)
Photo 1 Tracheostomy Care – 1. Mix solution of 1/2 cup mild liquid detergent and 1/2 cup water. 2. Remove lungs. 3. Pour mixture into simulated lungs. 4. Fill lungs to a level where suction catheter will pick up mixture. 5. Reattach lungs at connector.
To insert: 1. Attach valve and genitalia. 2. Work plate edges into pelvis cavity.
Photo 2
The belly plate with colostomy also contains the urinary reservoir and colostomy stoma.
The consistency of the solution approximates the mucus normally suctioned in a tracheostomy patient.
We recommend a size 6 tracheostomy tube. Opening will accommodate other sizes, but a size 6 is usually most suitable. Drain and air-dry lungs immediately after each use. NG Tube Placement – This manikin features an esophagus and stomach reservoir for practice of NG tube insertion and skills such as lavage and gavage.
For best results, lubricate the tube with either silicone spray or liquid detergent prior to NG or OG tube insertion.
Laerdal
2
Nursing Anne
English
To fill reservoir: a. Remove colostomy stoma. b. Fill with fluid. c. Gently reinsert stoma.
6. Slide large washer and wing nut over bolt. 7. Use screwdriver to hold bolt while tightening wing nut inside pelvis. (Figure 2) To remove legs, reverse procedure.
Make sure genitalia and urinary connectors are in place prior to filling. Injection Pads – a. To remove, squeeze pad with fingers and pull. b. To replace, squeeze pad and insert in opening.
Dusting pads with talcum powder will assist with reinsertion. Injection pads may be injected with water. Foam should be removed from pads immediately following training. Squeeze out fluid and air dry.
Figure 2
Waist, Knee and Ankle Joints – These joints are connected with a bolt and lock nut. To remove, unscrew lock nut and pull bolt from joint. Segments will now easily disconnect.
IV Arm – Multiple Venipuncture sites: • Dorsal Veins of Hand (3) • Antecubital - Cephalic Vein - Median Vein - Basilic Vein
Attachment hardware is located in envelope inside carton. Arms – Arms are attached with a 4 1/2” long bolt, three washers, a spring and a wing nut.
A 22 gauge needle or smaller is recommended to extend the life of the IV Arm. When using an IV catheter, lubricate with manikin lubricant for easier insertion.
Figure 1
To attach: 1. Unfasten chest skin from shoulders. 2. Pull skin back to expose chest cavity. 3. Locate hole in shoulder. 4. Remove deltoid injection pad from arm by squeezing skin in center of pad while pulling. 5. Slide small washer over bolt. 6. Insert bolt through hole in arm and hole in manikin’s shoulder. 7. Add large washer, spring, another large washer and wing nut to bolt inside manikin’s chest. (Figure 1) 8. Use a screwdriver to hold bolt steady while tightening wing nut.
Directions for Use: 1. Attach IV bag to IV tubing. 2. Attach IV tubing to either vein. 3. Allow fluid to flow through arm and out other vein. 4. Clamp off flow of water from open vein. The arm is now ready to practice venipuncture.
When excessive leaking occurs at puncture sites, either a new vein system or skin should be installed to reduce loss of fluid. We recommend working at a sink when replacing the skin and vein system.
To remove arms, reverse procedure. Replacing Skin and Veins: Legs – Legs are attached with a 6” long bolt, a spring, a large washer, a small washer and a wing nut.
1. Remove skin: If replacing skin and veins, cut off skin. This can be done with a sharp knife, scalpel or scissors. (Figure 3) When finished, discard skin. (Figure 4)
Attachment hardware is located in envelope inside carton. To attach: 1. Remove belly plate and colon reservoir from manikin to locate hole in hip. 2. Remove thigh injection pad from leg by squeezing skin in center of pad while pulling. 3. Slide spring and small washer over bolt. 4. Insert bolt through hole in thigh. 5. Insert bolt through hole in pelvis.
Nursing Anne
Figure 3
Figure 4
3
Laerdal
Replacing veins: (Keeping skin) 1. Lubricate inside of skin with liquid detergent; let it flow down into the finger area. 2. Begin at top of arm and slowly pull skin down and off of arm. Do not roll, as that will cause skin to bind. 3. Remove tubing from track in mandrel. Glue may need to be scraped away to allow removal. 4. Rinse and dry vein grooves well and swab with alcohol. Be sure to remove any excess glue. 5. Place new veins along grooves, (Figure 5) spot gluing as needed. (We recommend a fast-drying glue.)
Genitalia: Both male and female genitalia have been provided for urinary catheterization and enema training procedures. Tube-like valves, with a screw cap on one end, connect urethra and anus to corresponding reservoirs. This cap must be connected to genitalia openings. Soft vinyl end of connector is attached to urinary and anal reservoirs with a white clamp. (Long valve connects urinary reservoir; short valve connects anal reservoir.) Pelvic support pin must be removed and replaced immediately when assembling and disassembling genitalia. (Figure 6)
Figure 6 Figure 5 Pelvic support pin must be replaced. Failure to replace pin will result in pelvic spread.
6. Generously lather arm mandrel with liquid soap.
Heat arms skins before replacing on mandrel. This can be done with a blow-dryer.
If this occurs, the genitalia module will no longer fit properly in the manikin.
7. Slide hand into skin. 8. Work skin over fingers, as with a glove. 9. Work arm skin up, over mandrel.
To disassemble: 1. Lift up on belly plate. 2. Pull upper portion of genitalia back to remove pelvic support pin. 3. Belly plate, genitalia with connectors, and colon reservoir may now be removed simultaneously.
Blood Pressure Arm – 1. Place Blood Pressure Cuff on arm. 2. Attach tubing on cuff to clear tube, located underneath Nursing Anne’s arm. (Photo 3) See VitalSim DFU for complete Blood Pressure operating procedures.
To assemble: (Photos 5, 6 & 7) 1. Screw both valves onto genitalia. When attaching valves, be sure alignment of genitalia, urinary reservoir (belly plate) and colon reservoir are as illustrated in Figure 7. 2. Lift up on edge of belly plate. 3. Pull down upper portion of genital. 4. Insert into pelvic cavity. 5. Replace the pelvic support pin. 6. Press belly plate into position.
Photo 3
Do not insert needles into blood pressure arm.
Long valve connects urinary reservoir; short valve connects anal reservoir.
Auscultation of Heart, Breath and Bowel Sounds and Fetal Tones – 1. Connect Nursing Anne to VitalSim Unit, via cable located on back of manikin. (Photo 4)
Figure 7
See VitalSim DFU for complete Heart, Breath and Bowel Sound Auscultation.
Photo 5 Slide tube to meet ridge on connector.
Photo 4
Photo 6 Area where clamp is placed.
Photo 7 Apply clamp and squeeze to tighten. Laerdal
4
Nursing Anne
Reservoir should be removed from manikin, inverted, drained and completely air-dried before storing.
English
Colon Reservoir – Colon reservoir inserts into pelvic cavity with narrow end downward and connector pointing outward. This connector attaches reservoir to anal valve on genitalia. (Photo 8)
To remove legs: 1. Remove abdominal plate by pulling up on its edges. 2. Remove genitalia and all internal attachments, reservoirs and pelvic pin. (If using sounds abdominal plate, detach cable.) 3. Remove thigh injection pad by squeezing skin in center of pad while pulling. 4. Locate wing nut on inside of pelvis. 5. Using screwdriver to hold bolt in place, twist and remove wing nut. 6. Remove spring and small washer from bolt. (Figure 8) 7. Remove bolt from thigh and pelvis.
Photo 8
Urinary Catheterization and Enema Simulation –
Figure 8
Catheters should be well lubricated with manikin lubricant or full strength liquid soap prior to using.
To attach Fundus Module:
After several uses, catheter may “hang” when water has washed away lubricant, causing friction and binding. If this occurs, generously lubricate a catheter and insert into urethra several times.
Fundus skin
Symphysis Pubis
Genitalia
If catheter hangs during removal, work it with an “in and out” motion. Use warm water in reservoirs when possible to keep soap from clogging the catheters. Make sure reservoirs are well drained of all water before disconnecting valves. Check List for Valves That May Leak: a. Do valve connections have an O-ring? b. Does the white clamp fit firmly against base of valve? c. Are valves attached correctly? d. If valves are attached correctly, are they properly connected to reservoirs and to genitalia?
Urinary Bladder
Connector
Fundus Foam Bottom
A size 16 French catheter is suggested for urethral catheterization. 1. Apply baby powder to pelvis and inner fundus skin. 2. Remove silicone straps from cut portion at back of fundus skin. 3. Slide skin up and over pelvis, with slit and straps positioned on posterior side of manikin. 4. Reattach legs. (Legs must be reattached at this point, without proceeding further with fundus upgrade assembly.) When reattaching legs, make sure to leave space in between thigh and skin to allow for leg articulation without rubbing against fundus skin. 5. Pull fundus skin partially down pelvis, exposing internal pelvic area. 6. Place fundus foam bottom inside pelvis. 7. Using connectors, connect genitalia to urinary reservoir. 8. Place genitalia/urinary reservoir inside pelvis. This must be done from the genitalia area. Go through 8. 9. the genitalia opening to place the reservoir and genitalia. (Photo 9) 9. Place symphysis pubis pelvic pin. This replaces the pelvic pin already located in the manikin. (Photo 9) 10. Pull fundus skin up and attach three (3) tabs at back. 11. Insert “firm” or “boggy” fundus ball.
Size 7mm catheter is suggested for enema simulation.
Troubleshooting – What can I do if my manikin develops a pelvic spread? Cinch pelvis with a belt and heat with a hair dryer to soften, cinching as you heat. Insert pin, leaving belt in place until cool. What do I do if my connectors leak? Make sure C-clamps are squeezed tightly into place and connectors are screwed on tightly. What can I do if I can’t remove my catheter? Make sure the cuff is deflated. Attaching Nursing Anne Modules to Manikin: Fundus Skills Module - Legs, internal components and genitalia must be removed from pelvis.
Applying baby powder to skin and modules will assist in attachment and removal.
Photo 9
Nursing Anne
5
Laerdal
Mastectomy Module: 1. Remove chest skin from female manikin by detaching at shoulders and back of torso. 2. Place mastectomy module with single foam breast insert over torso. 3. Reattach at shoulders and back of torso.
Replacement Parts: Product Number: 380471 380475 380600 380650 381402 381403 381404 381410 381411 381412 381413 381417 300-00150 300-00450 300-00550 300-00650 300-00750 300-00850 300-00950 300-01850 300-01950 300-02050 300-02150 300-02250 300-02950 300-03050 300-03150 300-03250 300-03350 300-03450 300-03550 300-03650 300-03850 300-03950 300-04250 300-04350 300-04550 300-04850 300-04950 325-00150 325-00250 325-00350 325-00450 325-00550 325-00650 325-00750 325-00850 325-00950 325-01150 325-01250 325-01350 325-01450 325-01550 325-01650 325-01750 325-01850 325-01050 325-02050 325-02150 325-02250 325-02350 325-02450 325-02550 325-02650 325-02750 375-51001 200-02050 325-03650 325-03450 325-03550
Breast Exam Module:
Caution! Misuse could result in damage to this module. 1. Remove chest skin from female manikin by detaching at shoulder and along back of torso. 2. Apply powder to back of nodules, back of breasts and inside tunnels. Nodules with pegs are to be fitted in the chest plate; nodules with out pegs may be inserted into tunnels on back of breasts. Do not use sharp instruments to insert or remove nodules from breasts! 3. Position breasts on plate. Nodules on back of breast will align with grooves in chest plate when positioned correctly. 4. Reattach chest skin.
VitalSim Connection See Vital DFU for complete connection and operating procedures. Care and Maintenance – 1. Clean with mild soap and water; do not submerse manikin or parts in cleaning fluids or water. Apply a light coat of talcum powder to the face and chest skin to achieve skin-like feeling. 2. Use only on clean surface. Avoid felt tipped markers, ink pens, acetone, iodine or other staining products and avoid placing the manikin on newsprint or inked lines of any kind. 3. To ensure longevity, each manikin should be cleaned after each training session and a general inspection should be conducted regularly. 4. Modules and all other parts should be drained and air-dried thoroughly before storage and disinfected when needed. After use of injection pads (use water only), accumulated water should be squeezed out. Do not store wet foam pads in the skin. To prevent mildew or mold, pads can be soaked in a mild solution of disinfectant and water or bleach and water. Squeeze excess solution from pads, allow them to dry, then store or reinsert in manikin. 5. Articulating parts will benefit from a light application of talcum powder prior to training sessions. 6. Store properly between teaching sessions.
Laerdal
6
Description: Plug, Belly plate-Adult Pin, Pelvis Leg Assembly, Left Adult Leg Assembly, Right Adult Pad Assembly, Deltoid Injection Adult Stoma, Infected Colostomy Stump, Left Lower Leg Foot, Diabetic Right Adult Pad, Thigh Packing Adult Pad, Thigh Sutured Adult Leg, Varicose Lower Right Adult Pad, Thigh Debridement Adult Pad Assembly, Thigh Injection Adult Valve/Clamp Set, Anal Adult Hosp Urin/Anal CVK Valve/Clamp Set, Urinary Hosp Adult Lubricant, Manikin-4 oz Bottle W/Sprayer Blood, Simulated-4 oz Red Plug, Tracheostomy Denture Set, Upper/Lower Adult Teeth, Upper-Adult Teeth, Lower-Adult Belly plate Assembly, Hosp w/Speakers Adult Belly plate Assembly, Hosp 3 Hole Adult Reservoir Assembly, Colon Hosp Adult Thigh, Right Adult Leg, Lower Right Adult Foot, Right Adult Thigh, Left Adult Leg, Lower Left Adult Foot, Left Adult Belly plate, Packing Adult Belly plate Sutured Adult Genitalia Assembly, Adult Male Genitalia Assembly, Adult Female Hardware Set, Adult Manikin-Legs/Arms to Body Hardware Set, Adult Manikin-Pelvis/Torso Belly plate Assembly, Suture/Drain Hosp Adult Gown, Hospital-Back Tie Stoma, Soft Style w/Thru Hole Pad Assembly, Ventral Gluteal Injection Adult Female Pad Assembly, Gluteal Injection Adult Female Kit, Skin/Vein Adult Female Multi-Venous IV Arm Module, Fundus Skills and Assessment-Nursing Anne Wound Set, Care and Assessment Adult Female Module, Mastectomy-Nursing Anne Module, Breast Exam-Nursing Anne Head Assembly, Female-Advanced Intubation Head Lung Assembly, Small-Adult Intubation Head Genitalia, Blank-Adult Female Arm Assembly, Blood Pressure Arm Assembly, Right Plain Adult Female Arm Assembly, Left Plain Adult Female Arm, Upper Left Plain Female Forearm, Left Plain w/Hand Female Arm, Upper Right Plain Female Forearm, Right Plain w/Hand Female Chest plate Assembly, Hospital Adult Female VitalSim Skin Assembly, Chest-Hospital Adult Female Insert, Breast Foam-Left Insert, Breast Foam-Right Pad, Dorsal Gluteal Ulcer Adult Female Pad, Ventral Gluteal Ulcer Adult Female Torso Assembly, Hospital Adult Female VitalSim Pelvis, Hospital w/o Bridge Adult Female Reservoir Assembly, Stomach Hospital Adult Female Arm, Female Multi-Venous IV Training Cuff Assembly, Blood Pressure, VitalSim Chest Skin (No ECG) Chest Skin (Spacer Style) Retrofit Kit (Chest Skin Spacer Style)
Nursing Anne
325-00550 325-00650 325-00750 325-00850 325-00950 325-01150 325-01250 325-01350 325-01450 325-01550 325-01650 325-01750 325-01850 325-01050 325-02050 325-02150 325-02250 325-02350 325-02450 325-02550 325-02650 325-02750 375-51001 200-02050 325-03650 325-03450 325-03550
Wound Set, Care and Assessment Adult Female Module, Mastectomy-Nursing Anne Module, Breast Exam-Nursing Anne Head Assembly, Female-Advanced Intubation Head Lung Assembly, Small-Adult Intubation Head Genitalia, Blank-Adult Female Arm Assembly, Blood Pressure Arm Assembly, Right Plain Adult Female Arm Assembly, Left Plain Adult Female Arm, Upper Left Plain Female Forearm, Left Plain w/Hand Female Arm, Upper Right Plain Female Forearm, Right Plain w/Hand Female Chest plate Assembly, Hospital Adult Female VitalSim Skin Assembly, Chest-Hospital Adult Female Insert, Breast Foam-Left Insert, Breast Foam-Right Pad, Dorsal Gluteal Ulcer Adult Female Pad, Ventral Gluteal Ulcer Adult Female Torso Assembly, Hospital Adult Female VitalSim Pelvis, Hospital w/o Bridge Adult Female Reservoir Assembly, Stomach Hospital Adult Female Arm, Female Multi-Venous IV Training Cuff Assembly, Blood Pressure, VitalSim Chest Skin (No ECG) Chest Skin (Spacer Style) Retrofit Kit (Chest Skin Spacer Style)
若想取得更多关于配件的资料, 请与我们中国各地办 事处联络.
本产品(当带有 CE 标志时)符合必需的 CE
Chinese
要求及 1999/5/EC 委员会指定的其它相关规 定。
Nursing Anne
7
Laerdal
300-03050 300-03150 300-03250 300-03350 300-03450 300-03550 300-03650 300-03850 300-03950 300-04250 300-04350 300-04550 300-04650 300-04750 300-04850 300-04950 325-00150 325-00250 325-00350 325-00450 325-00550 325-00650 325-00750 325-00850 325-00950 325-01150 325-01250 325-01350 325-01450 325-01550 325-01650 325-01750 325-01850 325-01050 325-02050 325-02150 325-02250 325-02350 325-02450 325-02550 325-02650 325-02750 375-51001 200-02050 325-03650 325-03450 325-03550
Leg, Lower Right Adult Foot, Right Adult Thigh, Left Adult Leg, Lower Left Adult Foot, Left Adult Belly plate, Packing Adult Belly plate Sutured Adult Genitalia Assembly, Adult Male Genitalia Assembly, Adult Female Hardware Set, Adult Manikin-Legs/Arms to Body Hardware Set, Adult Manikin-Pelvis/Torso Belly plate Assembly, .Suture/Drain Hosp Adult Belly plate Assembly, Staple/Drain Hosp Adult Belly plate, Abdominal Injection Hosp Adult Gown, Hospital-Back Tie Stoma, Soft Style w/Thru Hole Pad Assembly, Ventral Gluteal Injection Adult Female Pad Assembly, Gluteal Injection Adult Female Kit, Skin/Vein Adult Female Multi-Venous IV Arm Module, Fundus Skills and Assessment-Nursing Anne Wound Set, Care and Assessment Adult Female Module, Mastectomy-Nursing Anne Module, Breast Exam-Nursing Anne Head Assembly, Female-Advanced Intubation Head Lung Assembly, Small-Adult ...Intubation Head Genitalia, Blank-Adult Female Arm Assembly, Blood Pressure Arm Assembly, Right Plain Adult Female Arm Assembly, Left Plain Adult Female Arm, Upper Left Plain Female Forearm, Left Plain w/Hand Female Arm, Upper Right Plain Female Forearm, Right Plain w/Hand Female Chest plate Assembly, Hospital Adult Female VitalSim Skin Assembly, Chest-Hospital Adult Female Insert, Breast Foam-Left Insert, Breast Foam-Right Pad, Dorsal Gluteal Ulcer Adult Female Pad, Ventral Gluteal Ulcer Adult Female Torso Assembly, Hospital Adult Female VitalSim Pelvis, Hospital w/o Bridge Adult Female Reservoir Assembly, Stomach Hospital Adult ... Female Arm, Female Multi-Venous IV Training Cuff Assembly, Blood Pressure, VitalSim Chest Skin (No ECG) Chest Skin (Spacer Style) Retrofit Kit (Chest Skin Spacer Style)
다른 피부색의 교체 부품에 대한 자세한 정보는 지정 대리점에 문의하시기 바랍니다. 이 제품은 CE 마크가 있을 경우에 필수적인 CE 요구 조건 및 다른 1999/5/EC 지시를 준수합니다.
Laerdal
8
Nursing Anne