Laerdal Medical
Nursing Kelly VitalSim and Nursing Kelly Directions for Use Rev D
Directions for Use
100 Pages
Preview
Page 1
Introduction
Table of Contents
Nursing Kelly VitalSim is a full-body, lifelike vinyl manikin designed to teach all skills from basic patient handling to advanced nursing, including the measurement of noninvasive blood pressure and the auscultation and recognition of normal and abnormal heart, lung and bowel sounds.
Introduction...1 Laerdal Recommends...1 Items Included...2 Skills Taught...2 Teeth...2 Carotid Pulse...2 Tracheostomy Plug & Care...2 NG Tube Placement...2 Intubation...3 Chest...3 Lungs...3 Stomach Reservoir...3 Belly Plates...3 Injection Pads...3 Waist, Knee and Ankle Joints...3 Arms...3 Legs...4 IV Arm...4 Replacing Skin & Vein System...4 Blood Pressure Arm...5 Auscultation of Heart, Breath and Bowel Sounds ...5 Genitalia...5 Colon Reservoir...6 Urinary Catheterization and Enema Simulation...6 Troubleshooting...6 VitalSim...7 Care and Maintenance...7 Replacement Parts...7
Nursing Kelly
English
English
The manufacturing quality of this simulator should provide many sessions of training when reasonable care and maintenance are practiced.
Laerdal Recommends IV Injections – 22 gauge needle, or smaller Tracheostomy Tube – Size 6 NG Tube – Size 16 French Endotracheal Tube – 7.5 or smaller Laryngoscope Blade - Size #2 or #3, straight or curved blade Urethral Catheter – 16 French Enema Simulation – 7 mm
Caution: Latex This product contains Natural Rubber latex which may cause allergic reactions when in contact with humans.
1
Laerdal
Items Included
Teeth
(1) Full-Body Manikin (1) Articulating Blood Pressure Training Arm (Nursing Kelly VitalSim) (1) Articulating Multi-Venous IV Training Arm (1) Hospital Gown (1) Male Genitalia (1) Female Genitalia (3) Urinary Valves (3) Anal Valves (1) 10 foot Manikin Connector Cable (Nursing Kelly VitalSim) (1) Simulated Blood Concentrate (1) Manikin Lubricant Spray (1) Assembly Tool Kit (1) Direction for Use (1) Laerdal Global Warranty Booklet
To remove: Grasp firmly and lift. Insert and remove bottom teeth first when performing denture care. To reinsert both sets: a. Begin on one side and work around, aligning ridges with corresponding grooves in jaws. (Dusting with baby powder is helpful.) (Photo 1) b. Press firmly into place.
Optional Accessories Wound Assessment & Care (1) Lacerated Hand with Forearm Surgical Incision and Painted Sutures (1) Chest Surgical Incision Module (1) Abdominal Packing Module (1) Abdominal Incision Module with Painted Sutures (1) Abdominal Incision Modules with Penrose drain Staples and Nylon Sutures (One each) (1) Abdominal Subcutaneous Heparin and Insulin Injection Module (1) Thigh Packing and Irrigation Module (1) Thigh Suture Module with Nylon Sutures (1) Thigh Debridement Module (1) Infected Colostomy Stoma (1) Gluteal and Ventro-Gluteal Decubitus Ulcer Modules (One each) (1) Below Knee Amputation Stump (1) Below Elbow Amputation Stump (1) Diabetic Foot with Gangrenous Toes and Heel Decubitus ulcer (1) Varicose Vein Leg with Stasis Ulcer
Photo 1
Carotid Pulse To generate a carotid pulse, use the hand held red bulb located on the right axillary side of manikin. Firmly squeeze bulb while palpating for pulse at carotid site.
Tracheostomy Plug The Tracheostomy plug may be removed by grasping firmly, then lifting up and out. To replace, press into hole.
Skills Taught
Tracheostomy Care
• Basic patient handling • Denture care • Oral hygiene • Oral and nasal Intubation • Eye and ear irrigation (simulated) • NG Tube insertion, care medication administration and removal • Lavage/Gavage • Tracheostomy care and suctioning • Blood pressure skills (When used with VitalSim) • IV care and management • Subcutaneous and intramuscular injection • Oxygen delivery procedures • Ostomy irrigation and care • Catheterization skills • Enema simulation • Colonic irrigation • Wound assessment and care • Bandaging and dressing • Auscultation and recognition of normal and abnormal heart, breath and bowel sounds (When used with VitalSim)
1. Mix solution of 1/2 cup mild liquid detergent and 1/2 cup water. 2. Remove lungs and trachea. 3. Pour mixture into simulated lungs. 4. Fill lungs to a level where suction catheter will pick up mixture. 5. Reattach lungs at connector. The consistency of the solution approximates the mucus normally suctioned in a tracheostomy patient. We recommend a size 6 tracheostomy tube. Opening will accommodate other sizes, but a size 6 is usually most suitable.
Drain and air-dry lungs immediately after each use. Be careful not to introduce fluids into speaker ports or near electronics in manikin’s chest.
NG Tube Placement This manikin features an esophagus and stomach reservoir for practice of NG tube insertion and skills such as Lavage and Gavage. For best results, lubricate the tube with either manikin lubricant or liquid detergent prior to NG or OG tube insertion.
Laerdal
2
Nursing Kelly
English
Intubation The following equipment is recommended: a. Endotracheal tube, size 7.5 ID or smaller b. Manikin Lubricant spray or liquid soap c. 10 ml syringe d. Laryngoscope blade, size #2 or #3 straight or curved e. Laryngoscope handle f. NG Tube, size 16 French Photo 2
Remove trach plug prior to insertion of intubation tubes. To insert: 1. Attach valve and genitalia. 2. Work plate edges into pelvis cavity.
Intubation tubes and airway passages should be sprayed with manikin lubricant spray or lubricated with liquid soap prior to intubation.
The belly plate with colostomy also serves as the urinary reservoir. To fill reservoir: a. Remove colostomy stoma. b. Fill with fluid. c. Gently reinsert stoma.
Chest Plate To remove: 1. Apply pressure to center of plate. 2. Work your fingers under edge of plate while lifting.
Make sure genitalia and urinary connectors are in place prior to filling.
To insert: 1. Position plate over cavity. 2. Work plate edges into groove on torso cavity.
Injection Pads a. To remove, squeeze pad with fingers and pull. b. To replace, squeeze pad and insert in opening.
Lungs Lungs may be removed from bronchial tubes by unscrewing them at the connector site. To replace, reverse procedure.
Dusting pads with talcum powder will assist with reinsertion.
Stomach Reservoir The stomach reservoir attaches to esophagus with a connector. Unscrew reservoir from esophagus to fill or drain with water.
Injection pads may be injected with water. Foam should be removed from pads immediately following training. Squeeze out fluid and air dry.
Belly Plate with Multi-Sounds
Waist, Knee and Ankle Joints
To remove: 1. Apply pressure to center of plate. 2. Work your fingers under edge of plate while lifting. 3. Disconnect bowel sound speaker connector to release plate.
These joints are connected with a bolt and lock nut. To remove, unscrew lock nut and pull bolt from joint. Segments will now easily disconnect. When assembled, talcum powder should be used in joints to assist articulation.
Dusting with talcum powder is helpful in replacing belly plates.
Arms
To insert: 1. Position plate over cavity. 2. Reconnect bowel sound speaker. 3. Work plate edges into groove on pelvis cavity.
Arms are attached with a 4,5” long bolt, three washers, a spring and a wing nut. Attachment hardware is located in envelope inside carton.
Belly Plate with Colostomy Stoma To remove: 1. Apply pressure to center of plate. 2. Work fingers under edge while lifting. (Photo 2)
Nursing Kelly
To attach: 1. Remove chest plate. 2. Locate hole in shoulder. 3. Remove deltoid injection pad from arm by squeezing skin in center of pad while pulling. 4. Slide small washer over bolt. 5. Insert bolt through hole in arm and hole in manikin’s shoulder. 6. Add large washer, spring, another large washer and wing nut to bolt. (Figure 1) 3
Laerdal
Directions for Use: 1. Attach IV bag to IV tubing. 2. Attach IV tubing to either latex vein. 3. Allow fluid to flow through arm and out other latex vein. 4. Clamp off flow of water from open vein. The arm is now ready to practice venipuncture. When excessive leaking occurs at puncture sites, either a new vein system or skin should be installed to reduce loss of fluid.
Figure 1
We recommend working at a sink when replacing the skin and vein system.
7. Use a screwdriver to hold bolt steady while tightening wing nut. 8. Reinsert chest plate and deltoid pad. To remove arms, reverse procedure.
Replacing Skin and Veins Remove skin: If replacing skin and veins, cut off skin. This can be done with a sharp knife, scalpel or scissors. (Figure 3) When finished, discard skin, but keep thumb insert.
Legs Legs are attached with a 6” long bolt, a spring, a large washer, a small washer and a wing nut. Attachment hardware is located in envelope inside carton. To attach: 1. Remove belly plate from manikin to locate hole in hip. 2. Remove thigh injection pad from leg by squeezing skin in center of pad while pulling. 3. Slide spring and small washer over bolt. 4. Insert bolt through hole in thigh. 5. Insert bolt through hole in pelvis. 6. Slide large washer and wing nut over bolt. 7. Use screwdriver to hold bolt while tightening wing nut. (Figure 2)
Figure 3 Replacing veins: (Keeping skin) 1. Lubricate inside of skin with liquid detergent; let it flow down into the finger area. 2. Begin at top of arm and slowly pull skin down and off of arm. Do not roll, as that will cause skin to bind. Thumb will detach with skin; be sure to place in new skin. 3. Remove tubing from track in mandrel. Glue may need to be scraped away to allow removal. 4. Rinse and dry vein grooves well and swab with alcohol. Be sure to remove any excess glue.
Figure 4 Figure 2 To remove legs, reverse procedure.
IV Arm Multiple Venipuncture sites: • Dorsal Veins of Hand (3) • Antecubital - Cephalic Vein - Median Vein - Basilic Vein
Figure 5 5. Place new veins along grooves, (Figures 4 & 5) spot gluing as needed. (We recommend a fast-drying glue.) 6. Generously lather arm mandrel with liquid soap. Add thumb insert.
A 22 gauge needle or smaller is recommended to extend the life of the IV Arm.
Heat arms skins before replacing on mandrel. This can be done with a blow-dryer.
When using an IV catheter, lubricate with manikin lubricant for easier insertion.
Laerdal
4
Nursing Kelly
English
7. Slide hand into skin. (Photo 3) Do not insert needles into blood pressure arm.
Auscultation of Heart, Breath and Bowel Sounds Connect Nursing Kelly to VitalSim Unit, via cable located on back of manikin. (Photo 8) Photo 3 8. Work skin over fingers, as with a glove. (Photo 4)
Photo 8 Photo 4
See VitalSim DFU for complete Heart, Breath and Bowel Sound Auscultation.
9. Work arm skin up, over mandrel. (Photos 5 & 6)
Genitalia Both male and female genitalia have been provided for urinary theterization and enema training procedures. Tube-like valves, with a screw cap on one end, connect urethra and anus to corresponding reservoirs. This cap must be connected to genitalia openings. Soft vinyl end of connector is attached to urinary and anal reservoirs with a white clamp. (Long valve connects urinary reservoir; short valve connects anal reservoir.)
Photo 5
Pelvic support pin must be removed and replaced immediately when assembling and disassembling genitalia. (Figure 6)
Photo 6 Figure 6
Blood Pressure Arm 1. Place Blood Pressure Cuff on arm. 2. Attach tubing on cuff to clear tube, located underneath Nursing Kelly’s arm. (Photo 7)
Pelvic support pin must be replaced. Failure to replace pin will result in pelvic spread. If this occurs, the genitalia module will no longer fit properly in the manikin. To disassemble: 1. Lift up on belly plate. 2. Pull upper portion of genitalia back to remove pelvic support pin. 3. Belly plate, genitalia with connectors, and colon reservoir may now be removed simultaneously. To assemble: (Photos 9, 10 & 11) 1. Screw both valves onto genitalia. When attaching valves, be sure alignment of genitalia, urinary reservoir (belly plate) and colon reservoir are as illustrated in Figure 7.
Photo 7 See VitalSim DFU for complete Blood Pressure operating procedures. Nursing Kelly
5
Laerdal
Colon Reservoir Colon reservoir inserts into pelvic cavity with narrow end downward and connector pointing outward. This connector attaches reservoir to anal valve on genitalia. (Photo 12)
Figure 7 2. Lift up on edge of belly plate. 3. Pull down upper portion of genital. 4. Insert into pelvic cavity. 5. Replace the pelvic support pin. 6. Press belly plate into position.
Photo 12 Reservoir should be removed from manikin, inverted, drained and completely air-dried before storing.
Long valve connects urinary reservoir; short valve connects anal reservoir.
Urinary Catheterization and Enema Simulation Catheters should be well lubricated with manikin lubricant or full strength liquid soap prior to using.
After several uses, catheter may “hang” when water has washed away lubricant, causing friction and binding. If this occurs, generously lubricate a catheter and insert into urethra several times.
Photo 9 Slide tube to meet ridge on connector.
If catheter hangs during removal, work it with an “in and out” motion. Use warm water in reservoirs when possible to keep soap from clogging the catheters. Make sure reservoirs are well drained of all water before disconnecting valves. Check List for Valves That May Leak: a. Do valve connections have an O-ring? b. Does the white clamp fit firmly against base of valve? c. Are valves attached correctly? d. If valves are attached correctly, are they properly connected to reservoirs and to genitalia?
Photo 10 Area where clamp is placed.
A size 16 French catheter is suggested for urethral catheterization. Size 7mm catheter is suggested for enema simulation.
Troubleshooting What can I do if my manikin develops a pelvic spread? Cinch pelvis with a belt and heat with a hair dryer to soften, cinching as you heat. Insert pin, leaving belt in place until cool. Photo 11
What do I do if my connectors leak? Make sure C-clamps are squeezed tightly into place and connectors are screwed on tightly.
Apply clamp and squeeze to tighten.
What can I do if I can’t remove my catheter? Make sure the cuff is deflated.
Laerdal
6
Nursing Kelly
Replacement Parts
Product Number: Description: 312029 ����������������������� Kit, Skin/Vein Adult Multi-Venous IV Arm 380200 ����������������������� Arm Assembly, Blood Pressure 380460 ����������������������� Genitalia, Blank-Adult Male 380471 ����������������������� Plug, Belly plate-Adult 380475 ����������������������� Pin, Pelvis 380600 ����������������������� Leg Assembly, Left Adult 380650 ����������������������� Leg Assembly, Right Adult 380700 ����������������������� Arm, Male Multi-Venous IV Training 380800 ����������������������� Arm Assembly, Left Plain Adult 380801 ����������������������� Hand, Left Adult Male 381401 ����������������������� Arm, Upper Right Adult Male 381402 ����������������������� Pad Assembly, Deltoid Injection Adult 381403 ����������������������� Stoma, Infected Colostomy 381404 ����������������������� Stump, Left Lower Leg 381410 ����������������������� Foot, Diabetic Right Adult 381411 ����������������������� Pad, Thigh Packing Adult 381412 ����������������������� Pad, Thigh Sutured Adult 381413 ����������������������� Leg,Varicose Lower Right Adult 381414 ����������������������� Pad, Gluteal Ulcerated Adult Male 381415 ����������������������� Pad,Ventro-Gluteal Ulcerated Adult Male 381416 ����������������������� Hand, Lacerated w/Forearm Adult Male 381417 ����������������������� Pad, Thigh Debridement Adult 200-00550 ����������������� Cuff Assembly, Blood Pressure VitalSim 300-00150 ����������������� Pad Assembly, Thigh Injection Adult 300-00250 ����������������� Pad Assembly,Ventral Gluteal Injection Adult Male 300-00350 ����������������� Pad Assembly, Gluteal Injection Adult Male 300-00450 ����������������� Valve/Clamp Set, Anal Hosp Urin/Anal CVK 300-00550 ����������������� Valve/Clamp Set, Urinary Hosp Adult 300-00650 ����������������� Lubricant, Manikin-4 oz Bottle W/Sprayer 300-00750 ����������������� Blood, Simulated-4 oz Red 300-00850 ����������������� Plug, Tracheostomy 300-00950 ����������������� Denture Set, Upper/Lower Adult 300-01050 ����������������� Wound Set, Care and Assessment Adult Male 300-01150 ����������������� Head Assembly,VitalSim W/Trach Plug Adult Male 300-01350 ����������������� Reservoir Assembly, Stomach-Hosp Adult Male 300-01550 ����������������� Lung Bag Assembly 300-01650 ����������������� Chest plate Assembly,VitalSim Hosp Adult Male 300-01750 ����������������� Stump, Right Forearm Adult Male 300-01850 ����������������� Teeth, Upper-Adult 300-01950 ����������������� Teeth, Lower-Adult 300-02050 ����������������� Belly plate Assembly, Hosp w/Speakers Adult 300-02150 ����������������� Belly plate Assembly, Hosp 3 Hole Adult 300-02250 ����������������� Reservoir Assembly, Colon Hosp Adult 300-02350 ����������������� Forearm, Right Adult Male 300-02450 ����������������� Pad, Forearm Right Non-Injection Adult Male 300-02550 ����������������� Hand, Right Adult Male 300-02650 ����������������� Arm, Upper Left Adult Male 300-02750 ����������������� Forearm, Left Adult Male 300-02850 ����������������� Pad, Forearm Left Non-Injection Adult Male 300-02950 ����������������� Thigh, Right Adult 300-03050 ����������������� Leg, Lower Right Adult 300-03150 ����������������� Foot, Right Adult 300-03250 ����������������� Thigh, Left Adult 300-03350 ����������������� Leg, Lower Left Adult 300-03450 ����������������� Foot, Left Adult 300-03550 ����������������� Belly plate, Packing Adult 300-03650 ����������������� Belly plate Sutured Adult 300-03750 ����������������� Chest plate Sutured Adult 300-03850 ����������������� Genitalia Assembly, Adult Male 300-03950 ����������������� Genitalia Assembly, Adult Female 300-04050 ����������������� Pad Assembly, Right Forearm IV 300-04150 ����������������� Pad Assembly, Left Forearm IV 300-04250 ����������������� Hardware Set, Adult Manikin-Legs/Arms to Body 300-04350 ����������������� Hardware Set, Adult Manikin-Pelvis/Torso 300-04450 ����������������� Plug, Arm Adult 300-04550 ����������������� Belly plate Assembly, Suture/Drain Hosp Adult 300-04650 ����������������� Belly plate Assembly, Staple/Drain Hosp Adult 300-04750 ����������������� Belly plate, Abdominal Injection Hosp Adult 300-04850 ����������������� Gown, Hospital-Back Tie 300-04950 ����������������� Stoma, Soft Style w/Thru Hole 300-05150 ����������������� Arm Assembly, Right Plain Adult
This productis isin in compliance the This product compliance withwith the essential essential requirements of Council requirements of Council Directive 89 / Directive 336 / 89 / 336 EEC; EMC Directive. EEC; EMC /Directive.
Please contact Laerdal Customer Service for more information on Replacement Parts in other skin tones.
Nursing Kelly
English
380650 Leg Assembly, Right Adult 381402 Pad Assembly, Deltoid Injection Adult 381403 Stoma, Infected Colostomy 381404 Stump, Left Lower Leg 381410 Foot, Diabetic Right Adult 381411 Pad,Thigh Packing Adult 381412 Pad,Thigh Sutured Adult VitalSim™ Connection 381413 Leg,Varicose Lower Right Adult 381417 Pad,Thigh Debridement Adult See Vital DFU for complete 300-00150 Pad Assembly,Thigh Injection Adult connection 300-00450and operating Valve/Clamp Set, Anal Adult Hosp Urin/Anal CVK procedures. 300-00550 Valve/Clamp Set, Urinary Hosp Adult 300-00650 Lubricant, Manikin-4 oz Bottle W/Sprayer 300-00750 Blood, Simulated-4 oz Red 300-00850 Plug,Tracheostomy 300-00950 Denture Set, Upper/Lower Adult 300-01850 Teeth, Upper-Adult 300-01950 Teeth, Lower-Adult 300-02050 Belly plate Assembly, Hosp w/Speakers Adult 300-02150 Belly plate Assembly, Hosp 3 Hole Adult 300-02250 Reservoir Assembly, Colon Hosp Adult 300-02950 Thigh, Right Adult 300-03050 Leg, Lower Right Adult 300-03150 Foot, Right Adult 300-03250 Thigh, Left Adult 300-03350 Leg, Lower Left Adult 300-03450 Foot, Left Adult 300-03550 Belly plate, Packing Adult 300-03650 Belly plate Sutured Adult 300-03850 Genitalia Assembly, Adult Male 300-03950 Genitalia Assembly, Adult Female 300-04250 Hardware Set, Adult Manikin-Legs/Arms to Body 300-04350 Hardware Set, Adult Manikin-Pelvis/Torso 300-04550 Belly plate Assembly, Suture/Drain Hosp Adult 300-04650 Belly plate Assembly, Staple/Drain Hosp Adult 300-04750 Belly plate, Abdominal Injection Hosp Adult 300-04850 Gown, Hospital-Back Tie 300-04950 Stoma, Soft Style w/Thru Hole 325-00150 Pad Assembly,Ventral Gluteal Injection Adult Female 325-00250 Pad Assembly, Gluteal Injection Adult Female 325-00350 Kit, Skin/Vein Adult Female Multi-Venous IV Arm Care and Maintenance 325-00450 and Assessment-Nursing Annein 1. Clean with mild soap and Module, water; Fundus do notSkills submerse manikin or parts 325-00550 Wound Set, Care Adult Female cleaning fluids or water. Apply a light coatand ofAssessment talcum powder to the face 325-00650 Module, Mastectomy-Nursing Anne and chest skin to achieve skin-like feeling. 325-00750 Module, Breast Exam-Nursing Anne 2. Use only on clean surface. Avoid felt tipped markers, ink pens, acetone, 325-00850 Head Assembly, Female-Advanced Intubation Head iodine or other staining products and avoid placing theIntubation manikinHead on 325-00950 Lung Assembly, Small-Adult newsprint any kind. 325-01150 or inked lines of Genitalia, Blank-Adult Female 325-01250 Arm Assembly, Blood 3. To ensure longevity, each manikin should bePressure cleaned after each training 325-01350 Arm Assembly, Adult Female session and a general inspection shouldRight be Plain conducted regularly. 325-01450and all other parts Arm Assembly, Plain Adult 4. Modules should be Left drained and Female air-dried thoroughly 325-01550 Arm, Upper Left Plain Female before storage and disinfected when needed. After use of injection pads 325-01650 Forearm, Left Plain w/Hand Female (use water only), accumulated water should be squeezed out. Do not 325-01750 Arm, Upper Right Plain Female store wet foam pads in theForearm, skin. To prevent mildew or mold, pads can be 325-01850 Right Plain w/Hand Female soaked in a mild solution of disinfectant andHospital water Adult or bleach water. 325-01050 Chest plate Assembly, Femaleand VitalSim Squeeze pads, allow them to Adult dry, then 325-02050excess solution from Skin Assembly, Chest-Hospital Femalestore or 325-02150 Insert, Breast Foam-Left reinsert in manikin. 325-02250 parts will benefit Insert,from Breasta Foam-Right 5. Articulating light application of talcum powder 325-02350 prior to training sessions. Pad, Dorsal Gluteal Ulcer Adult Female 325-02450 Pad,Ventral Gluteal Ulcer Adult Female 6. Store properly between teaching sessions. 325-02550 Torso Assembly, Hospital Adult Female VitalSim 325-02650 Pelvis, Hospital w/o Bridge Adult Female 325-02750 Reservoir Assembly, Stomach Hospital Adult Female 375-51001 Arm, Female Multi-Venous IV Training 200-02050 Cuff Assembly, Blood Pressure,VitalSim
7
Laerdal
更换配件 产品编号:
300-04650 ����������������� Belly plate Assembly, Staple/Drain Hosp Adult 300-04750 ����������������� Belly plate, Abdominal Injection Hosp Adult 300-04850 ����������������� Gown, Hospital-Back Tie 300-04950 ����������������� Stoma, Soft Style w/Thru Hole 300-05150 ����������������� Arm Assembly, Right Plain Adult
说明:
312029 ����������������������� Kit, Skin/Vein Adult Multi-Venous IV Arm 380200 ����������������������� Arm Assembly, Blood Pressure 380460 ����������������������� Genitalia, Blank-Adult Male 380471 ����������������������� Plug, Belly plate-Adult 380475 ����������������������� Pin, Pelvis 380600 ����������������������� Leg Assembly, Left Adult 380650 ����������������������� Leg Assembly, Right Adult 380700 ����������������������� Arm, Male Multi-Venous IV Training 380800 ����������������������� Arm Assembly, Left Plain Adult 380801 ����������������������� Hand, Left Adult Male 381401 ����������������������� Arm, Upper Right Adult Male 381402 ����������������������� Pad Assembly, Deltoid Injection Adult 381403 ����������������������� Stoma, Infected Colostomy 381404 ����������������������� Stump, Left Lower Leg 381410 ����������������������� Foot, Diabetic Right Adult 381411 ����������������������� Pad, Thigh Packing Adult 381412 ����������������������� Pad, Thigh Sutured Adult 381413 ����������������������� Leg,Varicose Lower Right Adult 381414 ����������������������� Pad, Gluteal Ulcerated Adult Male 381415 ����������������������� Pad,Ventro-Gluteal Ulcerated Adult Male 381416 ����������������������� Hand, Lacerated w/Forearm Adult Male 381417 ����������������������� Pad, Thigh Debridement Adult 200-00550 ����������������� Cuff Assembly, Blood Pressure VitalSim 300-00150 ����������������� Pad Assembly, Thigh Injection Adult 300-00250 ����������������� Pad Assembly,Ventral Gluteal Injection Adult Male 300-00350 ����������������� Pad Assembly, Gluteal Injection Adult Male 300-00450 ����������������� Valve/Clamp Set, Anal Hosp Urin/Anal CVK 300-00550 ����������������� Valve/Clamp Set, Urinary Hosp Adult 300-00650 ����������������� Lubricant, Manikin-4 oz Bottle W/Sprayer 300-00750 ����������������� Blood, Simulated-4 oz Red 300-00850 ����������������� Plug, Tracheostomy 300-00950 ����������������� Denture Set, Upper/Lower Adult 300-01050 ����������������� Wound Set, Care and Assessment Adult Male 300-01150 ����������������� Head Assembly,VitalSim W/Trach Plug Adult Male 300-01350 ����������������� Reservoir Assembly, Stomach-Hosp Adult Male 300-01550 ����������������� Lung Bag Assembly 300-01650 ����������������� Chest plate Assembly,VitalSim Hosp Adult Male 300-01750 ����������������� Stump, Right Forearm Adult Male 300-01850 ����������������� Teeth, Upper-Adult 300-01950 ����������������� Teeth, Lower-Adult 300-02050 ����������������� Belly plate Assembly, Hosp w/Speakers Adult 300-02150 ����������������� Belly plate Assembly, Hosp 3 Hole Adult 300-02250 ����������������� Reservoir Assembly, Colon Hosp Adult 300-02350 ����������������� Forearm, Right Adult Male 300-02450 ����������������� Pad, Forearm Right Non-Injection Adult Male 300-02550 ����������������� Hand, Right Adult Male 300-02650 ����������������� Arm, Upper Left Adult Male 300-02750 ����������������� Forearm, Left Adult Male 300-02850 ����������������� Pad, Forearm Left Non-Injection Adult Male 300-02950 ����������������� Thigh, Right Adult 300-03050 ����������������� Leg, Lower Right Adult 300-03150 ����������������� Foot, Right Adult 300-03250 ����������������� Thigh, Left Adult 300-03350 ����������������� Leg, Lower Left Adult 300-03450 ����������������� Foot, Left Adult 300-03550 ����������������� Belly plate, Packing Adult 300-03650 ����������������� Belly plate Sutured Adult 300-03750 ����������������� Chest plate Sutured Adult 300-03850 ����������������� Genitalia Assembly, Adult Male 300-03950 ����������������� Genitalia Assembly, Adult Female 300-04050 ����������������� Pad Assembly, Right Forearm IV 300-04150 ����������������� Pad Assembly, Left Forearm IV 300-04250 ����������������� Hardware Set, Adult Manikin-Legs/Arms to Body 300-04350 ����������������� Hardware Set, Adult Manikin-Pelvis/Torso 300-04450 ����������������� Plug, Arm Adult 300-04550 ����������������� Belly plate Assembly, Suture/Drain Hosp Adult Laerdal
本产品(当带有 CE 标志时)符合必需的 CE 要求 及 1999/5/EC 委员会指定的其它相关规定。
请联系客户服务代表获取有关其它皮肤张力备件的详细 信息。
8
Nursing Kelly
© LAERDAL 2004. All rights reserved. 9895 rev D Printed in US