Directions for Use
13 Pages
Preview
Page 1
Laerdal Medical Documentation – Check Revision Before Use FOO-OOlO Rev A
~
.STRQLlED /CQN .
Vv .7f;:),?J; Os
REV
DESCRIPTION OF CHANGE
CHANGE
REFERENCE
:]3
"I
Release
REFERENCE
VERIFIED
APPROVED
DATEANDSIGN
DATEANDSIGN
DATEANDSIGN
DATEANDSIGN
DATEANDSIGN
NjA
REPLACES
NjA
TT-IV/IO
ORIGINATOR DATEANDSIGN
DMR
THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO LAERDAL AND SHALL NOT BE USED FOR ANY PURPOSE DETRIMENTAL TO OR BE REPRODUCED WITHOUT PERMISSION OF LAERDAL
PRODUCT GROUP
I
NjA IODS3Z-D
TOOL
PART NO
N/A
-
0
- 0 REV
-'NI.f.
helping save lives
mLE
DFU Kit, Male Multi-Venous
- A REV
1005320
LaerdaI
DHF
'),
J3tv
DOCUMENT NO
PRO-ML03-0028 *3IDS--
IV Arm REV
A
Laerdal Medical Documentation – Check Revision Before Use
Multi-Venous Access Arm Kit Directions for Use
Laerdal Medical Documentation – Check Revision Before Use
270-00001
2
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
TABLE OF CONTENTS Laerdal Recommends
4
Items Included
5
Skill Taught
5
Anatomy Represented
5
Instructions for Use
5
Replacing Skin
6
Replacing Veins
6
Care and Maintenance
8
Warranty
8
Replacement Parts
10
270-00001
3
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
The Multi-Venous Access Arm Kit is a full-size lifelike arm, which realistically simulates that of a patient. It is specifically designed for training professionals in the practice of venipuncture. As a result of quality construction and the ease of replacing individual parts, this simulator should provide many sessions of training when reasonable care and maintenance are practiced.
Laerdal Recommends: Needle or Catheter – Size 21-gauge or smaller When using a catheter or other venipuncture device, lubricate them with lubricant spray for easier insertion.
270-00001
4
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
Items Included: (1) Multi-Venous Access Arm (5) Syringes (1) IV bag with hose and clamp (1) Replacement arm skin (1) Replacement multi-vein (1) Bottle of simulated red blood concentrate (1) Manikin Lubricant Spray (1) Carry Case
Skills Taught: •
Adult venipuncture
Anatomy Represented: • • • • •
Dorsal veins of hand (3) Cephalic Median Basilic Antecubital
Instructions for Use: 1. Attach IV tubing to either vein. 2. Allow fluid to flow through arm and out other end of latex vein. 3. Clamp off flow of fluid. Simulator is now ready to practice venipuncture.
Laerdal Recommends: We recommend nothing larger than a 21-gauge needle. This will extend life of skin and veins. When using a catheter or other venipuncture devices, lubricate them with lubricant spray for easier insertion.
270-00001
5
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
Replacing Skin and Veins: Laerdal Recommends When leaking occurs sites, The either a new 1. Ifexcessive replacing both skin and veins,atcutthe off puncture skin and discard. vein orthumb skin will should bewith installed to(New reduce fluid. detach the skin. skin loss has aof thumb.) We recommend working at a sink when replacing skin and veins. Replacing skin: 1. Cut off skin. This can be done with a sharp knife or scalpel. (Figure1) 2. Discard skin.
Fig. 1
Replacing veins: (Keeping skin) 1. Lubricate inside of skin with liquid detergent; let it flow down into the finger area. 2. Begin at top of arm and slowly pull skin down and off of arm. Do not roll, as that will cause skin to bind. Thumb will detach with skin. 3. Remove tubing from track in mandrel. Glue may need to be scraped away to allow removal. 4. Rinse and dry vein grooves well and swab with alcohol. Be sure to remove any excess glue. 5. Place new veins along grooves, (Figure 2) spot gluing as needed. (We recommend a fast drying glue.) 6. Generously lather arm mandrel with liquid soap. Fig. 2 Laerdal Recommends Heat arms skins before replacing on mandrel. This can be done with a blowdryer.
270-00001
6
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
7. Slide hand into skin. (Photo 1)
Photo 1 8. Work skin over fingers, as with a glove. (Photo 2)
Photo 2 9. Work arm skin up, over mandrel. (Photos 3 & 4.)
Photo 3
270-00001
Photo 4
7
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
Care and Maintenance: 1. Clean with mild soap and water; do not submerse trainer or parts in cleaning fluids or water. 2. Use only on clean surface. Avoid felt tipped markers, ink pens, acetone, iodine or other staining products and avoid placing the manikin on newsprint or inked lines of any kind. 3. To ensure longevity, each trainer should be cleaned after each training session and a general inspection should be conducted regularly. 4. Modules and all other parts should be drained and airdried thoroughly before storage and disinfected when needed. 5. Articulating parts will benefit from a light application of talcum powder prior to training sessions. 6. Store properly between teaching sessions.
Warranty Laerdal warrants to the purchaser that its products are free from defects in material and workmanship for a period of one (1) year from the date of purchase by the original user. During the designated one (1) year period, Laerdal will, upon receipt of a product found to be defective due to materials or workmanship from the purchaser and notification in writing of the defect, at its option repair or replace any parts found to be defective or the entire product. Warranty period does not renew with replacement or repair of original product. Products found to be defective and notification of defects may also be sent to the authorized Laerdal dealer from whom the product was purchased. All postage, shipping or handling charges shall be the sole responsibility of the purchaser. Laerdal is responsible for the effects of safety, reliability and performance of its product(s) only if: – service, repair, readjustment or modification is carried out by Laerdal or persons authorized by Laerdal. – the electrical installation of the room where the product is used complies with pertinent equipment requirements. – the product is used in the proper manner in strict compliance with its Directions for Use.
270-00001
8
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
Laerdal shall not be liable under this warranty for incidental or consequential damages, or in the event any unauthorized repairs or modifications have been made or attempted, or when the product, or any part thereof, has been damaged by accident, misuse or abuse. This warranty does not cover batteries, fuses, normal wear and tear, excessive use, staining, discoloration or other cosmetic irregularity which does not impede or degrade product performance. Some states in the USA do not allow the exclusion or limitation of incidental or consequential damages, so those limitations or exclusions may not apply to you. There are no other express or implied warranties, whether of merchantability, fitness or purpose, or otherwise, on the product, its parts and accessories.
Cautions and Warnings This product contains Natural Rubber latex which may cause allergic reactions when in contact with humans.
270-00001
9
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
Replacement Parts: Part Number: 380700
Description: Right Multi-Venous IV Arm Skin & Multi-Vein Kit Adult Deltoid Pad Blood Concentrate Transfer Set Tubing Arm Attachment Hardware Set IV Bag with Tubing Transfer Set Manikin Lubricant Spray Carry Case
312029 381402 300-00750 TK-1003 1004492 1002961 300-00650 CC-0014
Please contact Customer Service Representatives for more information on Replacement Parts in other skin tones.
270-00001
10
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
(C) Copyright Medical Plastics Laboratory, Inc., Gatesville TX Document #1005320 Rev B June 9, 2004
270-00001
11
Laerdal
Laerdal Medical Documentation – Check Revision Before Use
Norway: LAERDAL MEDICAL AS P.O. Box 377, N-4002 Stavanger Tel. +47 51 51 17 00, Fax +47 51 52 35 57 E-mail: [email protected]
Italy: LAERDAL ITALIA s.r.l. Via Piero Gobetti 52/2 int.Z, 40129 Bologna Tel. +39 051-355587, Fax +39 051-355598 E-mail: [email protected].
Australia: LAERDAL Pty. Ltd. (ABN 47 003 817 490) 23 Edward Street, Oakleigh, Victoria 3166 Tel. +61 3 9569 4055, Toll free 1800 331 565 Fax +61 3 9569 4028, Toll free 1800 635 835 E-mail: [email protected]
Japan: LAERDAL MEDICAL JAPAN K..K.. Shinjuku IS Bldg.. 8F 2-13-12, Shinjuku, Shinjuku-ku, Tokyo 160-0022 Tel. 81-3-5919-2121, Fax: 81-3-5919-2122 E-mail: [email protected]
Benelux: "The Laerdal BeNeLux House" Dijkstraat 54, NL-5554 PS VALKENSWAARD Tel. +31 40 208 58 00, Fax +31 40 208 58 02 E-mail: [email protected]
Malaysia: LAERDAL HOSPILINE Sdn Bhd 12 Jalan Titir 33/25, Section 33, Shah Alam Technology Park, 40400 Shah Alam, Selangor Darul Ehsan, Tel +60 (3) 5122-7002, Fax +60 (3) 5122-5650 E-mail: [email protected]
Benelux: Belgium and Luxembourg LAERDAL BeNeLux NV Mechelsesteenweg 277, B-1800 VILVOORDE Tel. +32 2 253 36 96, Fax +32 2 253 36 90 E-Mail: [email protected]
New Zealand: LAERDAL NEW ZEALAND Ltd (GST Number 79-403-636) PO Box 302664, North Harbour, Auckland 1330 Tel. +61 3 9564 4066, Toll free 0800 523 732 Fax +61 3 9563 3368, Toll free 0800 528 852 E-mail: [email protected]
Canada and Latin America: LAERDAL MEDICAL CANADA LTD. 151 Nashdene Rd., Unit #45 Toronto, ON, Canada, M1V 4C3 Tel. +1 (416) 298-9600, Toll free 888/LAERDAL (523-7325) ou en français (800) 567-9987 Fax +1 (416) 298-8016 E-mail: [email protected]
Portugal: LAERDAL ESPANA, Sucursal em Portugal Rua da Bela Vista à Graca, no.31 A. Escritorio 9, 1170-054 Lisboa Tel. (+351)-21-816-6567, Fax (+351)-21-816-6568, Mob. (+351)-918765367 Spain: LAERDAL ESPANA, S.L. Manuel Tovar 19, 28034 Madrid Tel. (+34) 902-291110, Fax (+34) (91)-7291125 E-mail: [email protected]
Denmark: LAERDAL DANMARK Postbox 225, DK-8600 Silkeborg Tel. +45 80 333 112, Fax +45 80 333 555 E-mail: [email protected]
Sweden: LAERDAL MEDICAL AB Box 2064, Paviljongvägen 3-5, 132 02 Saltsjö-Boo Tel. +46 (0)8-55614610, Fax +46 (0)8-55614619 E-mail: [email protected]
Eastern Europe: LAERDAL C.E. EUROPE A-1060 Vienna, Mariahilferstr. 1d/1/3 Tel - Fax +43 15877140, Tel. +43 15815927 E-mail: [email protected]
United Kingdom: LAERDAL MEDICAL LTD. Laerdal House, Goodmead Road, Orpington, Kent BR6 0HX Tel. +44 (0)1689 876634, Fax +44 (0)1689 873800 E-mail: [email protected]
Far East: LAERDAL Singapore Pte Ltd No 1 Marine Parade Central #13-05, Parkway Centre Singapore 449408 Tel. +65 63464259, Fax +65 63467523 E-mail: [email protected]
USA LAERDAL MEDICAL CORPORATION 167 Myers Corners Road, P.O. Box 1840 Wappingers Falls, New York 12590-8840 Tel. (800) 431-1055, +1 (845) 297-7770 Fax (800) 227-1143, +1 (845) 298-4545 E-mail: [email protected]
Finland: LAERDAL OY Vattuniemenranta 2, 00210 HELSINKI Puhelin +358 (0)9-612 99 80, Telekopio +358 (0)9-692 77 99 E-mail: [email protected] France: LAERDAL MEDICAL FRANCE 1 rue des Vergers - Bâtiment n° 5 - 69578 Limonest Cedex Tél. +33 (0)4 72 52 02 52, Fax +33 (0)4 78 35 38 45 E-mail: [email protected]
LAERDAL TEXAS P.O. Box 38, 226 FM 116 South Gatesville, Texas 76528-0038 Tel. (800) 433-5539, (254) 865-7221 Telefax (254) 865-8011 E-mail: [email protected]
Germany: LAERDAL MEDICAL DEUTCHLAND GmbH Am Loferfeld 56, 81249 München Tel. +49 (0)89 / 864 954-0, Fax +49 (0)89 / 864 34 84 E-mail: [email protected]
270-00001
12
Laerdal