Directions for Use
11 Pages
Preview
Page 1
Neonatal Resuscitation Baby
Directions for Use
240-00001
2
Laerdal
Table of Contents Laerdal Recommends 4 Items Included 5 Skills Taught 5 Preparing the Trainer for Use 6 Disassembly and Reassembly 6 Lung Placement 7 Care and Maintenance 7 Warranty 8 Replacement Parts 9
240-00001
3
Laerdal
The Neonatal Resuscitation Baby is a full-body, lifelike vinyl manikin that realistically simulates a newborn patient. It is specifically designed for training professionals in the practice of neonatal intubation, umbilical catheterization and umbilical IV procedures. The manufacturing quality of this simulator should provide many sessions of training when reasonable care and maintenance are practiced.
Laerdal Recommends: Umbilical Catheter – Size 3.5 Laryngoscope Blade – Size 0 ET Tube – 3.0
240-00001
4
Laerdal
Items Included: (1) Neonatal Trainer (3) Umbilical Cords (1) MPL Manikin Lubricant (1) Diaper (1) Simulated Blood Concentrate (1) Baby Powder (1) Carry Case (1) Onesie Skills Taught: • Infant care and handling • Oral and nasal intubation • Oropharyngeal and Nasopharyngeal airway insertion • Right mainstem intubation • NG/OG tube insertion • Suctioning • Bag/Valve Mask ventilation • Chest compressions • Umbilical catheterization
Instructor Notes:
240-00001
5
Laerdal
Preparing the trainer for use: Filling stomach reservoir: 1. Remove stomach plug from left side of manikin. (Photo 1) 2. Place trainer on its right side and add 20-30cc of water through fill hole. (You may want to use a syringe when filling reservoir.) 3. Replace stomach plug.
Photo 1
Filling the umbilical reservoir: 1. Squeeze about 3 drops of simulated blood concentrate into umbilical reservoir and add water to fill. 2. Insert umbilical tubing through skin and partially into reservoir. (Photo 2)
Photo 2
Disassembly and Reassembly: 1. Remove arms and legs by rotating counter clockwise. 2. Slide skin off torso. 3. Remove foam ribcage and torso foam. 4. Remove head assembly by unscrewing the nut on the neck. (NOTE: Lungs and stomach reservoir will be attached to head.)
240-00001
6
Laerdal
To reassemble, reverse procedure.
Lung Placement: To get proper chest rise and fall, make sure lung bags are positioned as shown in picture. (Photo 3) Lungs must be folded under rib cage and should not extend below rib cage.
Rib cage is positioned on top of balloon lungs.
Photo 3
Care and Maintenance: 1. Clean with mild soap and water; do not submerse manikin or parts in cleaning fluids or water. 2. Use only on clean surface. Avoid felt tipped markers, ink pens, acetone, iodine or other staining products and avoid placing the manikin on newsprint or inked lines of any kind. 3. To ensure longevity, each manikin should be cleaned after each training session and a general inspection should be conducted regularly. 4. Modules and all other parts should be drained and air-dried thoroughly before storage and disinfected when needed. After use of injection pads (use water only), accumulated water should be squeezed out. Do not store wet foam pads in the skin. To prevent mildew or mold, pads can be soaked in a mild solution of disinfectant and water or bleach and water. Squeeze excess solution from pads, allow them to dry, then store or reinsert in manikin. 5. Articulating parts will benefit from a light application of talcum powder prior to training sessions. 6. Store properly between teaching sessions.
240-00001
7
Laerdal
Warranty Laerdal Medical warrants to the purchaser that its products are free from defects in material and workmanship for a period of one (1) year from the date of purchase by the original user. During the designated one (1) year period, Laerdal Medical will, upon receipt of a product found to be defective due to materials or workmanship from the purchaser and notification in writing of the defect, at its option repair or replace any parts found to be defective or the entire product. Warranty period does not renew with replacement or repair of original product. Products found to be defective and notification of defects may also be sent to the authorized Laerdal Medical dealer from whom the product was purchased. All postage, shipping or handling charges shall be the sole responsibility of the purchaser. Laerdal Medical is responsible for the effects of safety, reliability and performance of its product(s) only if: – service, repair, readjustment or modification is carried out by Laerdal Medical or persons authorized by Laerdal Medical. – the electrical installation of the room where the product is used complies with pertinent equipment requirements. – the product is used in the proper manner in strict compliance with its Directions for Use. Laerdal Medical shall not be liable under this warranty for incidental or consequential damages, or in the event any unauthorized repairs or modifications have been made or attempted, or when the product, or any part thereof, has been damaged by accident, misuse or abuse. This warranty does not cover batteries, fuses, normal wear and tear, excessive use, staining, discoloration or other cosmetic irregularity which does not impede or degrade product performance. Some states in the USA do not allow the exclusion or limitation of incidental or consequential damages, so those limitations or exclusions may not apply to you.
240-00001
8
Laerdal
There are no other express or implied warranties, whether of merchantability, fitness or purpose, or otherwise, on the product, its parts and accessories.
240-00001
9
Laerdal
REPLACEMENT PARTS LIST: Product Number: 1001348 1001335 1001336 1001337 1001338 1004106 1001343 1004506 1000262 CC-0009 9500-10-0018
Description: Umbilical Reservoir Right Arm Left Arm Right Leg Left Leg Head Assembly Torso Skin Umbilical Cord Set Manikin Lubricant Carry Case Onesie
Please contact Customer Service Representatives for more information on Replacement Parts in other skin tones
(C) Copyright Medical Plastics Laboratory, Inc., Gatesville TX Document #1004021 rev A February 11, 2003
240-00001
10
Laerdal
Norway: LAERDAL MEDICAL AS P.O. Box 377, N-4002 Stavanger Tel. +47 51 51 17 00, Fax +47 51 52 35 57 E-mail: [email protected]
Italy: LAERDAL ITALIA s.r.l. Via Piero Gobetti 52/2 int.Z, 40129 Bologna Tel. +39 051-355587, Fax +39 051-355598 E-mail: [email protected].
Australia: LAERDAL Pty. Ltd. (ABN 47 003 817 490) 23 Edward Street, Oakleigh, Victoria 3166 Tel. +61 3 9569 4055, Toll free 1800 331 565 Fax +61 3 9569 4028, Toll free 1800 635 835 E-mail: [email protected]
Japan: LAERDAL MEDICAL JAPAN K..K.. Shinjuku IS Bldg.. 8F 2-13-12, Shinjuku, Shinjuku-ku, Tokyo 160-0022 Tel. 81-3-5919-2121, Fax: 81-3-5919-2122 E-mail: [email protected]
Benelux:"The Laerdal BeNeLux House" Dijkstraat 54, NL-5554 PS VALKENSWAARD Tel. +31 40 208 58 00, Fax +31 40 208 58 02 E-mail: [email protected]
Malaysia: LAERDAL HOSPILINE Sdn Bhd 12 Jalan Titir 33/25, Section 33, Shah Alam Technology Park, 40400 Shah Alam, Selangor Darul Ehsan, Tel +60 (3) 5122-7002, Fax +60 (3) 5122-5650 E-mail: [email protected]
Canada: LAERDAL MEDICAL CANADA LTD. 151 Nashdene Rd., Unit #45 Toronto, ON, Canada, M1V 4C3 Tel. +1 (416) 298-9600, Toll free 888/LAERDAL (523-7325) ou en français (800) 567-9987 Fax +1 (416) 298-8016 E-mail: [email protected] Denmark: LAERDAL DANMARK Postbox 225, DK-8600 Silkeborg Tel. +45 80 333 112, Fax +45 80 333 555 E-mail: [email protected] Eastern Europe: LAERDAL C.E. EUROPE A-1060 Vienna, Mariahilferstr. 1d/1/3 Tel - Fax +43 15877140, Tel. +43 15815927 E-mail: [email protected]
New Zealand: LAERDAL NEW ZEALAND Ltd (GST Number 79-403-636) PO Box 302664, North Harbour, Auckland 1330 Tel. +61 3 9564 4066, Toll free 0800 523 732 Fax +61 3 9563 3368, Toll free 0800 528 852 E-mail: [email protected] Portugal: LAERDAL ESPANA, Sucursal em Portugal Rua da Bela Vista à Graca, no.31 A. Escritorio 9, 1170-054 Lisboa Tel. (+351)-21-816-6567, Fax (+351)-21-816-6568, Mob. (+351)-918765367 Spain: LAERDAL ESPANA, S.L. Manuel Tovar 19, 28034 Madrid Tel. (+34) 902-291110, Fax (+34) (91)-7291125 E-mail: [email protected]
Far East: LAERDAL Singapore Pte Ltd No 1 Marine Parade Central #13-05, Parkway Centre Singapore 449408 Tel. +65 63464259, Fax +65 63467523 E-mail: [email protected]
Sweden: LAERDAL MEDICAL AB Box 2064, Paviljongvägen 3-5, 132 02 Saltsjö-Boo Tel. +46 (0)8-55614610, Fax +46 (0)8-55614619 E-mail: [email protected]
Finland: LAERDAL OY Vattuniemenranta 2, 00210 HELSINKI Puhelin +358 (0)9-612 99 80, Telekopio +358 (0)9-692 77 99 E-mail: [email protected]
United Kingdom: LAERDAL MEDICAL LTD. Laerdal House, Goodmead Road, Orpington, Kent BR6 0HX Tel. +44 (0)1689 876634, Fax +44 (0)1689 873800 E-mail: [email protected]
France: LAERDAL MEDICAL FRANCE 1 rue des Vergers - Bâtiment n° 5 - 69578 Limonest Cedex Tél. +33 (0)4 72 52 02 52, Fax +33 (0)4 78 35 38 45 E-mail: [email protected]
USA and Latin America: LAERDAL MEDICAL CORPORATION 167 Myers Corners Road, P.O. Box 1840 Wappingers Falls, New York 12590-8840 Tel. (800) 431-1055, +1 (845) 297-7770 Fax (800) 227-1143, +1 (845) 298-4545 E-mail: [email protected]
Germany: LAERDAL MEDICAL DEUTCHLAND GmbH Am Loferfeld 56, 81249 München Tel. +49 (0)89 / 864 954-0, Fax +49 (0)89 / 864 34 84 E-mail: [email protected]
240-00001
MEDICAL PLASTICS LABORATORY, INC. P.O. Box 38, 226 FM 116 South Gatesville, Texas 76528-0038 Tel. (800) 433-5539, (254) 865-7221 Telefax (254) 865-8011 E-mail: [email protected]
11
Laerdal