Lafayette Instrument Company
JAMAR Owners Manual Issue 1
Owners Manual
8 Pages
Preview
Page 1
Hydraulic Hand Dynamometer Owner’s Manual Dynamomètre hydraulique à main Manuel d’emploi
The recognized standard for the measurement of hand grip strength La norme reconnue pour la mesure de la force de préhension
Contents English
About the Jamar ...2 Features...2 Operation/Normative Data for Grip Strength...2-3 Service Tips ...3-4
Adjustable Handle - Accommodates various size hands. The JAMAR handle adjusts to five grip positions: from 13/8" to 33/8", in half-inch increments. The adjustable handle allows therapists to quantify grip strength for different size objects since the size of the object being grasped may vary the grip strength on an individual patient.
Service/Recalibration ...4 References ...4
Operation To use the dynamometer:
For over 40 years the JAMAR Hand Dynamometer has been the industry standard for grip strength data collection. Many states use the JAMAR Hand Dynamometer as a standard testing instrument for compensation determinations.
Français
Nederlands
About the JAMAR®...
1. Set the adjustable handle to the desired spacing. (Before moving the handle from one position to another, note that the handle clip is located at the lower post (furthest from the gauge). If the handle is not replaced in the correct position, the readings will not be accurate). 2. Rotate the red peak-hold needle counter-clockwise to 0. 3. Let the patient comfortably arrange the instrument in his/her hand . Have patient squeeze with their maximum strength. The peak-hold needle will automatically record the highest force exerted. 4. Record the reading and reset the peak - hold needle to zero. NOTE: Due to temperature extremes during shipping, the gauge needle on your new JAMAR® Hydraulic Hand Dynamometer may not be resting on zero when you receive the instrument. If this is the case, the gauge needle can be easily repositioned by following these steps.
Deutsch
1. Unscrew the crystal and locate the center screw that holds the gauge needle. 2. Carefully hold the needle between your thumb and first finger.
Peak-Hold Needle
Peak-Hold Knob
Italiano
Features The JAMAR® Hand Dynamometer offers many features for routine screening as well as evaluation of hand trauma and disease. Dual-Scale Readout - The JAMAR Hand Dynamometer displays grip force in pounds and kilograms up to 200 pounds or 90 kilograms.
Español
Peak-Hold Needle - Automatically retains the highest reading until reset. Ideal for easy recording. Accurate and Reproducible - The JAMAR Hand Dynamometer is isometric in use and allows almost no perceptible motion of the handles, regardless of grip strength. Along with a comfortable grasp the JAMAR Hand Dynamometer ensures accurate and reproducible results.
2
Gauge Needle
Crystal
3. Using a screwdriver, turn the screw clockwise to move the needle lower or counterclockwise to move the needle higher. 4. Check the needle to make sure it is not bent before replacing the crystal.
Normative Grip Strength Data 2,3
10-11 12-13 14-15 16-17 18-19 20-24 25-29 30-34 35-39 40-44 45-49 50-54 55-59 60-64 65-69 70-74 75+
28.6 27.1 35.3 33.0 49.7 45.2 56.8 50.9 58.1 49.3 67.3 56.9 71.6 61.7 70.4 61.0 74.5 63.5 78.7 68.0 74.1 66.3 70.4 62.3 62.2 56.0 65.8 57.3 57.3 47.3 55.1 45.7 49.6 41.0 49.6 41.5 42.6 37.6
Proper Grip Strength Testing Procedures When Using Nomative Data Have the individual sit with their shoulder adducted and neutrally rotated, elbow flexed at 90º, forearm in neutral position, and wrist between 0º and 30º dorsiflexion and between 0º and 15º ulnar deviation. Set the JAMAR® Hand Dynamometer to the second handle position from the inside. Lightly hold around the readout dial to prevent inadvertent dropping. After the individual is positioned properly, say, “Squeeze as hard as you can...harder!...harder!...relax.”1
4.4 4.4 8.3 6.9 8.1 6.8 10.6 11.9 12.3 11.9 16.5 14.0 12.3 12.5 14.5 13.1 13.9 12.2 19.2 17.7 10.8 11.7 13.5 13.8 15.1 12.7 11.6 10.7 12.5 11.9 10.1 10.1 9.7 8.2 11.7 10.2 11.0 8.9
English
4.8 5.4 7.4 9.3 9.7 10.8 15.5 16.9 15.4 14.9 19.4 19.1 24.6 27.8 20.6 21.8 23.0 16.2 22.4 21.7 24.0 21.7 20.7 18.7 23.0 22.8 18.1 17.0 26.7 23.4 20.4 20.3 20.6 19.8 21.5 18.1 21.0 17.0
Nederlands
8-9
32.5 30.7 41.9 39.0 53.9 48.4 58.7 55.4 77.3 64.4 94.0 78.5 108.0 93.0 121.0 104.5 120.8 110.5 121.8 110.4 119.7 112.9 116.8 112.8 109.9 100.8 113.6 101.9 101.1 83.2 89.7 76.8 91.1 76.8 75.3 64.8 65.7 55.0
Français
R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L
Females Mean SD
3. Mathiowetz, V., Weimer, D.M., & Federman, S.M. (1986). Grip and Pinch Strength: Norms for 6- to 19- Year Olds. American Journal of Occupational Therapy, 40(10) 705-711.
Service Tips The JAMAR® Hand Dynamometer provides reliable service, with minimum maintenance. Occasionally, it’s a good idea to make a few checks (as listed below) to make sure the instrument is reading accurately. If you detect a problem, return the instrument to Homecraft AbilityOne for servicing.
Posts
Record the scores of three successive trials for each hand tested. The average score of the three trials can be compared to the normative data on the left, which is in pounds. From a statistical perspective, scores within two standard deviations of the mean are considered within normal limits. In addition, the individuals’ ability to use their hand functionally needs to be considered when interpreting a grip strength performance.
Remove the adjustable handle and check that each post moves freely up and down on its guide (the part the post bears on), even when you exert pressure on the side of the post. About once a year, place a small amount of grease on the two guides. If excessive friction exists between the post and guide, return the dynamometer for service.
1. Mathiowetz, V., Weber, K., Volland, G., & Kashman, N., (1984). Reliability and Validity of Hand Strength Evaluations. Journal of Hand Surgery, 9A, 222-226.
To check the hydraulic mechanism, first remove the adjustable handle. While watching the top post, push down on the bottom post. Normally, both posts should
2. Mathiowetz, V., Kashman, N., Volland, G., Weber, K., Dowe, M., & Rogers, S. (1985). Grip and Pinch Strength: Normative Data for Adults. Archives of Physical Medicine and Rehabilitation, 66(2) 69-74.
Deutsch
6-7
Males Mean SD
Italiano
Hand
Hydraulics
3
Español
Age
English Nederlands
travel about 1/8", with top and bottom posts travelling in opposite directions. Travel less than 1/16" requires service since it indicates a probable leak in the hydraulic system.
3. Specify the reason for your return.
Handle
5. Send your dynamometer and RA form to: Homecraft AbilityOne Shelley Close, Lowmoor Business Park, Kirkby-in-Ashfield, Nottinghamshire NG17 7ET, UK
Grasp the instrument normally and carefully look at the way the forks of the adjustable handle are supported on the posts. Each fork should touch the post approximately at its mid-point. If not, return the instrument for adjustment.
Peak-Hold Needle
LIMITED ONE YEAR WARRANTY
Turn the peak-hold knob counter-clockwise to check for excessive friction in the peak-hold assembly. If the peak-hold needle deflects the gauge needle, return the gauge for service.
Sammons Preston Rolyan warrants the JAMAR® 5030J1 Hand Dynamometer to be free from defects in workmanship and materials for one year from the date of purchase. Sammons Preston Rolyan will repair or replace, at its discretion, any instrument found defective during this period. If failure occurs after the one year warranty period, repairs will be made for a service charge. This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
Peak-Hold Knob
Français
Peak-Hold Needle
References The JAMAR® Hand Dynamometer has been in use for over 40 years, and has led to numerous data developments. Below is a partial list of references that may be used in order to further research data concerning the JAMAR Hand Dynamometer.
Deutsch
Gauge Needle
Crystal
If the peak-hold needle is knocked off its support pin, it can readily be re-positioned. Unscrew the crystal and turn it upside down. Locate the brass pin in the center of the crystal (the pin is part of the chrome knob on the outside of the crystal). Locate the slot on the brass pin and place the peak-hold needle into this slot.
Italiano
Calibration The JAMAR® Hand Dynamometer is calibrated by loading the center with weight and making appropriate adjustments in the gauge. It is not recommended that the user perform this operation, but rather, that the instrument be returned to Sammons Preston Rolyan for calibration. The calibration should be checked on a regular basis. If the instrument has been dropped or there is any reason to suspect that the calibration is erroneous, the instrument should be serviced immediately.
Service/Recalibration Español
4. Be sure to ship the dynamometer in its carrying case and a protective carton. Always insure the instrument with the post office or carrier.
1. Call +44 (0)1623 754047 to receive a repair request and authorisation (RA) number and shipping instructions. 2. Write the RA number on the RA label and on the outside of the shipping carton.
4
1. Delheimer S., Focht D., Schapmire D., Stewart T., St. James J.D., Townsend R. “Simultaneous Bilateral Testing: Validation of a New Protocol to Detect Insincere Effort During Grip and Pinch Strength Testing.” The Journal of Hand Therapy 15: 242-250, 2002. 2. Ewing-Fess, E. “A Method for Checking Jamar Dynamometer Calibration.” Journal of Hand Therapy 1. 1: 28-32, 1987. 3. Gill D., Reddon J., Renney C., Stefanyk W. “Hand Dynamometer: Effects of Trials and Session.” Perceptual and Motor Skills 61: 195-8, 1985. 4. Mathiowetz V., Federman S., Wiemer D. “Grip and Pinch Strength: Norms for 6 to 19 Year Olds.” The American Journal of Occupational Therapy 40: 705-11, 1986. 5. Mathiowetz V., Donahoe L., Renells C. “Effect of Elbow Position on Grip and Key Pinch Strength.” The Journal of Hand Surgery 10A: 694-7, 1985. 6. Mathiowetz V., Dove M., Kashman N., Rogers S., Volland G., Weber K. “Grip and Pinch Strength: Normative Data for Adults.” Arch Phys Med Rehabilitation 66: 69-72, 1985. 7. Mathiowetz V., Weber K., Volland G., Kashman N. “Reliability and Validity of Grip and Pinch Strength Evaluations.” The Journal of Hand Surgery 9A: 22-6, 1984.
Sammons Preston Rolyan 4 Sammons Court Bolingbrook, IL 60440
Sammons Preston Rolyan 4 Sammons Court Bolingbrook, IL 60440
Call toll free: 1-800-323-5547 In Canada call 1-800-665-9200
Ligne d’appel gratuit: 1-800-323-5547 Au Canada appelez le 1-800-665-9200
Fax toll free: 1-800-547-4333 In Canada fax 1-905-566-9207
Ligne d’appel gratuit: 1-800-547-4333 Au Canada fax 1-905-566-9207
Authorized European Representative:
Représentant européen autorisé :
Homecraft AbilityOne Shelley Close, Lowmoor Business Park, Kirkby-in-Ashfield, Nottinghamshire, NG17 7ET, UK Telephone: +44 (0)1623 754047 Facsimile: +44 (0)1623 755585
PART NO. 70523
Issue 1 © AbilityOne Homecraft Ltd. 2003