Sabina 200 Instruction Guide March 2012

Instruction Guide

12 Pages

Table of Contents Safety Instructions...2 Definitions...3 Technical Data...3 Measurements...4 Assembly...5 Operation...7 Charging the Batteries...8 Maximum Load...9 Recommended Lifting Accessories...9 Raising Operations...10 Simple Troubleshooting...11 Inspection and Maintenance...12 NOTE! This instruction guide contains important information for the user of the product. All who use the product should review and completely understand the contents of the instruction guide. Remember to keep the instruction guide in a place where it is always available to those using the product.  Safety Instructions  Before using, make sure that: • the lift is assembled in accordance with the assembly instructions • the lifting accessories are properly attached to the lift • the batteries have been charged for at least 12 hours • you have read the instruction guides for the lift and lifting accessories • personnel using the lift are informed of the correct operation and use of the lift. Before lifting, always make sure that: •	the lifting accessory are selected appropriately in terms of type, size, material and design with regard to the patient’s needs • the lifting accessories are not damaged • the lifting accessory are correctly and safely applied to the patient in order to avoid bodily injury • the lifting accessory is correctly applied to the sling bar • the sling bar latches are intact; missing or damaged latches must always be replaced • the sit-to-stand vest’s straps are properly connected to the sling bar hooks when the vest’s straps have been fully extended but before the patient is lifted from the underlying surface. • as a caregiver assure that the patient not are at risk of falling forward or to any side during lifting. After use, store the lift in forward direction towards a wall and out of reach of unauthorized Never leave a patient unattended in Sabina 200!  Sabina 200 have been tested by an accredited testing institute and fulfil the requirements specified in the Medical Device Directive 93/42/EEC, for Class 1 products. Viking S/Viking XS complies with the requirements in EN ISO 10535:2006, IEC 60601-1, IEC 60601-1-2, ANSI/AAMI ES60601-1, and CAN/CSA C22.2 no 60601-1. Under no circumstances must the lift be modified. If you have any questions, please contact Liko/Hill-Rom. Particular care must be observed when using strong sources of potential disturbance, such as diathermy, etc, so that diathermy cables are not positioned on or near the lift. If you have questions, please consult the responsible assistive-device technician or the supplier. The lift must not be used in areas where flammable mixtures may occur, for example in areas where flammable goods are stored. Sabina 200 • 7EN155105-04  2  www.liko.com
File Type: PDF
File Size: 1.47 MB
File Name: Liko - Sabina 200 Instruction Guide March 2012 - 2012-03.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions