Care and Maintenance of the Liko: Mobile Lifts Ceiling Lifts Sit to Stand Lifts Lift Stretchers English 7EN180818-02 2013-01-23
This instruction applies to Liko mobile lifts, ceiling lifts, sit to stand lifts, and lift stretchers, yet in this text we refer only to lifts. To avoid possible transmission of infectious disease, it is important to clean the lift if it has become soiled or if it is to be used by another patient. Also refer to your facility’s cleaning and disinfection policies for any additional guidelines on frequency. It is important to follow the recommendations in this manual to maintain the warranty and expected life time. This manual gives detailed cleaning and disinfecting procedures for Liko lifts. The instructions in this manual do not replace your facility’s cleaning and disinfection policies. This manual is intended for use by facility-approved persons only. To ignore this restriction could cause severe injury to people and serious damage to equipment. Liko/Hill-Rom recommends that the lift be disinfected prior to first use. Liko/Hill-Rom recommends to disinfect the lift prior to disposal in accordance with local environmental regulations. Liko’s products undergo continuous development, which is why we reserve the right to make product changes without prior notice. The only warranty Liko/Hill-Rom makes is the express written warranty extended on the sale or rental of its products. The information contained in this manual is subject to change without notice. Visit our website www.liko.com for updated versions of this manual or contact your local Liko/Hill-Rom representative for advice or more information. Safety recommendations • Wear protective equipment according to manufacturer’s instruction and per facility protocol throughout the cleaning operations, such as: rubber gloves, goggles, apron, face mask and shoe covers. • Unplug mains (AC power source) before cleaning and disinfection. • Never clean the lift by pouring water on it, steam cleaning it, or by using a high-pressure jet. • Refer to the recommendations made by the cleaning and disinfecting product manufacturer. Inadequate cleaning may increase risk of cross contamination!
1
7EN180818-02
2
www.liko.com
Alkyl dimethyl benzyl ammonium chloride = 13.238% Alkyl dimethyl ethylbenzyl ammonium chloride = 13.238%
Hydrogen Peroxide 0.1 -1.5% BenzylAlcohol: 1-5% Hydrogen Peroxide 0.1 -1.5% BenzylAlcohol: 1-5%
Ortho-Phenylphenol = 3.40% Ortho-Benzyl-para-Chlorophenol = 3.03
Sodium hypochlorite
Isopropyl alcohol = 70%
n-Alkyl dimethyl benzyl ammonium chlorides = 0.105% n-Alkyl dimethyl ethylbenzyl ammonium chlorides = 0.105%
Benzyl-C12-18-alkyldimethylammonium, chlorides (22 %) 2-Phenoxyethanol (20 %) Tridecylpolyethylenglycolether (15 %) Propan-2-ol (8 %)
Magnesium monoperoxyphtalate hexahydrate (50-100%) Anionic surfactant (5-10%) Nonionic surfactant (1-5%)
Hydrogen peroxyde (2.5-10 %) Lauryldimethylamine oxid (0-2.5 %) Ethanol (2.5-10 %)
Adipic acid 10-30% Amorphous silica < 1% Sodium Toluene sulphonate 5-10 % Troclosene sodium 10-30 %
Quaternary ammonium chloride
Accelerated Hydrogen Peroxide
Phenolic
Bleach
Alcohol
Quaternary ammonium
Benzyl-C12-18-alkyldimethylammonium, chlorides
Organic peroxide (type E, solid)
Ethanol
Troclosene sodium
*) Or equivalent
Didecyl dimethyl ammonium chloride = 8.704% Alkyl dimethyl benzyl ammonium chloride = 8.19%
Active ingredient
Quaternary ammonium chloride
Chemical class
4-6 in use
7
5.3 in use
approx 8.6 in use
11.5 - 12.5
5.0 – 7.0
12.2
Chlor-Clean
Anioxy-Spray WS
Dismozon Pur
Terralin Protect
CSI
Viraguard
Dispatch
Wexcide
Oxivir Tb
3
3.1 +/- 0.4 in use
HB Quat 25L
Virex II (256)
Cleaners / Disinfectant *)
9.5 in use
9.0 – 10.0 in use
pH
Application of commonly used Cleaning / Disinfectants on Liko products
Guest Medical Ltd
Anios
Bode
Shülke
Central Solutions Inc.
Veridien
Caltech
Wexford Labs
Johnson/Diversey
3M
Johnson/Diversey
Manufacturer *)
The lift straps for Golvo™ and ceiling lifts
Control box for all mobile lifts
The lift straps for Golvo™ and ceiling lifts
Foot rest for Sabina™ and Roll-On™
Viking™, Liko M220™, Liko M230™, Uno™, Sabina™, Golvo™, LikoLight™, Roll-On™, Likorall™, Multirall™
Hand controls for all lifts
The lift straps for Golvo™ and ceiling lifts
The lift straps for Golvo™ and ceiling lifts
Foot rest for Sabina™ and Roll-On™
May not be used on the following items:
Cleaning and Disinfection Recommendations All parts must be kept clean at all times in order to avoid the risk of infection. All necessary precautions must be taken to remove all visible stains and soiling. The cleaning and disinfecting method described below applies specifically to this device and all its accessories and is designed to save time and to help combat nosocomial infections more effectively. Equipment: • Protective equipment (such as: rubber gloves, goggles, apron, face mask and shoe covers) as recommended by the facility protocol and manufacturers instructions • Clean buckets • Cloths for washing and drying • Soft brush • Warm water • To find Cleaning / Disifectants compatible or not compatible for use on Liko’s products, follow the ”Application of commonly used Cleaning / Disinfectants on Liko products” at page 2 in this document.
7EN180818-02
3
www.liko.com
Viking™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. To have access to all areas run the lift into the highest and lowest positions and extend the base width adjustment entirely in and out. Remove the Battery to have access behind the battery. NOTE! Do not clean the piston rod! 4. Pay special attention to the following areas: • Sling bar (different designs) • Mechanical emergency lowering (different designs) • Handles • Hand control (different designs) • Emergency stop • Operation panel/display (where applicable) • Lever for base width adjustment (where applicable) • Pedal for base width adjustment (where applicable) • Locking handles • Wheels
Do not clean the piston rod!
Hand control
Sling bar
Battery
Handles Control box
Mechanical emergency lowering
Locking handle
Operation panel/ display
Emergency stop
Wheels
Lever for base width adjustment Pedal for base width adjustment
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The control box may not be cleaned with Anioxy Spray or equivalent.
7EN180818-02
4
www.liko.com
Liko M220™/Liko M230™ lifts Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. To have access to all areas run the lift into the highest and lowest positions and extend the base width adjustment entirely in and out. Remove the Battery to have access behind the battery. NOTE! Do not clean the piston rod! 4. Pay special attention to the following areas: • Sling bar • Mechanical emergency lowering • Handles • Hand control • Emergency stop • Pedal for base width adjustment (where applicable) • Wheels
Battery
Sling bar Control box Mechanical emergency lowering
Handles
Do not clean the piston rod! Hand control Emergency stop
Pedal for base width adjustment
Wheels
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The control box may not be cleaned with Anioxy Spray or equivalent.
7EN180818-02
5
www.liko.com
Uno™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. C lean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. W ipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. To have access to all areas run the lift into the highest and lowest positions and extend the base width adjustment entirely in and out. Remove the Battery to have access behind the battery. NOTE! Do not clean the piston rod! 4. Pay special attention to the following areas: • Sling bar (different designs) • Mechanical emergency lowering • Handles • Hand control • Emergency stop • Lever for base width adjustment (where applicable) • Locking handles • Wheels
Sling bar Handles Mechanical emergency lowering
Battery Hand control
Control box
Do not clean the piston rod!
Locking handles
Emergency stop Wheels Lever for base width adjustment
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The control box may not be cleaned with Anioxy Spray or equivalent.
7EN180818-02
6
www.liko.com
Sabina™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. To have access to all areas run the lift into the highest and lowest positions and extend the base width adjustment entirely in and out. Remove the Battery to have access behind the battery. The calf strap may be machine washed 60-80°C (140176°F), see ”Care and Maintenance of Liko Slings” for more information. NOTE! Do not clean the piston rod! 4. Pay special attention to the following areas: • Sling bar (different designs) • Side support (where applicable) • Handles • Mechanical emergency lowering (different designs) • Hand control • Emergency stop • Lower-leg support • Foot rest • Locking handles • Wheels • Lever for base width adjustment (where applicable) Sling bar Battery
Locking handles
Do not clean the piston rod!
Handles
Mechanical emergency lowering
Hand control Product label with serial no. (S/N)
Lower-leg support Calf strap
Control box
Locking handles
Foot rest Emergency stop Wheels
Side support
Lever for base width adjustment
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The control box may not be cleaned with Anioxy Spray or equivalent. The foot rest may not be cleaned with Terralin Protect, Virex II or equivalent. The leg support on Sabina II, S/N up to 460899 and leg support on Sabina 200, S/N up to 3501599 may only be cleaned with warm water and a facility approved neutral detergent. The leg support on Sabina II S/N from 460900 and leg support on Sabina 200, S/N from 3501600 may be cleaned with the recommended disinfectants. 7EN180818-02
7
www.liko.com
Golvo™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. To have access to all areas run the lift into the highest and lowest positions and extend the base width adjustment entirely out. Remove the Battery to have access behind the battery. Lower the sling bar to get access to the whole lift strap. Fully extend the lift strap by using the emergency lowering. After cleaning the lift strap, and before you raise the sling bar, make sure the lift strap has dried. After the emergency lowering device is used, the lifting level needs to be restored; see the Instruction Guide for the Golvo lift. 4. Pay special attention to the following areas: • Lift strap • Sling bar (different designs) • Arm rest • Mechanical emergency lowering • Hand control (different designs) • Handles • Operation panel (where applicable) • Emergency stop • Wheels
Lift strap
Battery Mechanical emergency lowering
Sling bar
Hand control Handles
Arm rest
Control box
Operation panel
Emergency stop Wheels
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The control box may not be cleaned with Anioxy Spray or equivalent. The lift strap may not be cleaned with Oxivir Tb, Dispatch, Chlor-Clean, Dismozon Pur or equivalent.
7EN180818-02
8
www.liko.com
LikoLight™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. To have access to all areas run the lift into the highest and lowest positions and extend the base width adjustment entirely in and out. Remove the Battery to have access behind the battery. NOTE! Do not clean the piston rod! 4. Pay special attention to the following areas: • Sling bar (different designs) • Mechanical emergency lowering • Handles • Hand control • Emergency stop • Pedal for base width adjustment • Lever for base width adjustment (where applicable) • Locking handles • Wheels
Battery Mechanical emergency lowering
Sling bar
Control box
Handles Do not clean the piston rod!
Hand control
Locking handles Pedal for base width adjustment
Emergency stop
Lever for base width adjustment Wheels
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The control box may not be cleaned with Anioxy Spray or equivalent.
7EN180818-02
9
www.liko.com
RollOn™ lift Cleaning Instruction 1. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 2. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. 3. Pay special attention to the following areas: • Torso cushion • Safety lock • Handles • Seat frame • Raising handles • Rear supports • Locking handles • Lower-leg support • Foot rest • Wheels
Torso cushion
Locking handle
Safety lock Handles
Seat frame
Rear supports
Raising handles
Lower-leg support
Foot rest
Locking handles
Wheels
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The foot rest may not be cleaned with Terralin Protect or Virex II or equivalent.
7EN180818-02
10
www.liko.com
Likorall™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. Clean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. Wipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. Lower the sling bar to get access to the whole lift strap. After cleaning the lift strap and before you raise the sling bar, make sure the lift strap has dried. The Likorall lift with mechanical emergency lowering: fully extend the lift strap by using the mechanical emergency lowering. After cleaning the lift strap and before you raise the sling bar, make sure the lift strap has dried. After the mechanical emergency lowering device is used, the lifting level needs to be restored; see the Instruction Guide for the Likorall lift. 4. Pay special attention to the following areas: • Lift strap • Electrical emergency lowering/raising • Emergency stop • Emergency stop cord • Mechanical emergency lowering (where applicable) • Sling bar (different designs) • Hand control (different designs) • Electrical emergency lowering device (where applicable)
Electrical emergency lowering/raising Emergency stop Emergency stop cord
Lift strap
Electrical emergency lowering device
Mecanical emergency lowering
Sling bar Hand control
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The lift strap may not be cleaned with Oxivir Tb, Dispatch, Chlor-Clean, Dismozon Pur or equivalent.
7EN180818-02
11
www.liko.com
Multirall™ lift Cleaning Instruction 1. Unplug mains (AC power source) before cleaning and disinfection. 2. C lean the lift with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 3. W ipe down the entire lift starting from the top down. Do not use a cloth that is dripping wet. Lower the sling bar to get access to the whole lift strap. After cleaning the lift strap and before you raise the sling bar, make sure the lift strap has dried. 4. Pay special attention to the following areas: • Electrical emergency lowering/raising • Mechanical emergency lowering • Emergency stop • Handles • Lift strap • Hand control • Sling bar (different designs)
Electrical emergency lowering/raising Mechanical emergency lowering Handles
Emergency stop
Lift strap
Hand control
Sling bar
Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the lift, wipe the lift with a moist cloth using clean water to remove all disinfectant residue. The lift may not be cleaned with CSI or equivalent. The hand control may not be cleaned with Viraguard or equivalent. The lift strap may not be cleaned with Oxivir Tb, Dispatch, Chlor-Clean, Dismozon Pur or equivalent.
7EN180818-02
12
www.liko.com
Lift Stretchers Cleaning Instruction 1. Clean the stretcher with a moist cloth, using warm water and a facility approved neutral detergent. A soft brush can be used to remove stains and resistant soil. 2. Wipe down the entire stretcher starting from the top down. Do not use a cloth that is dripping wet.
Liko OctoStretch™
Liko FlexoStretch™/Liko UltraStretch™
LikoStretch 1900™
LikoStretch 1800™
LikoStretch Mod 600 IC™ Disinfect Repeat the cleaning instructions after reading the ”Application of commonly used Cleaning / Disifectants on Liko products” at page 2 in this document. Follow the manufacturer’s instructions for proper use of the disinfectant. After you disinfect the stretcher, wipe the stretcher with a moist cloth using clean water to remove all disinfectant residue. The stretcher may not be cleaned with CSI or equivalent.
7EN180818-02
13
www.liko.com
© Copyright Liko AB 2013-01
w w w . l i k o . com Liko AB Nedre vägen 100 SE-975 92 Luleå Sweden [email protected]