Page 1
OPERATING INSTRUCTIONS
OPERATING TABLE SYSTEM MAGNUS
GA 1180.01 EN 16
Copyright notice All rights reserved. Any duplication, adaption or translation without prior written consent is prohibited unless otherwise provided for in the relevant copyright laws. © Copyright MAQUET GmbH & Co. KG Subject to technical modification! Illustrations and technical specifications may vary slightly from those in these Operating Instructions as a result of ongoing product development. V16.02 07-05-2012
MAGNUS 1180.01 GA 1180.01 EN 16
Table of contents
1 1.1 1.2 1.2.1 1.2.2 1.2.3 1.2.4 1.2.5 1.2.5.1 1.2.5.2 1.3 1.3.1 1.3.2 1.3.3 1.3.3.1 1.3.3.2 1.3.3.3 1.3.3.4 1.3.4 1.3.4.1 1.3.4.2 1.3.4.3 1.3.4.4 1.3.4.5 1.3.4.6 1.3.4.7 1.3.5 1.4 1.4.1 1.4.2 1.4.3 1.4.4 1.4.5 1.5 1.6 1.7 1.7.1 1.7.2 1.7.2.1 1.7.2.2 1.7.3 1.7.3.1 1.7.4 1.7.4.1 1.7.5 1.7.5.1
Introduction Foreword... 1 Environmental protection... 1 Packaging... 1 Rechargeable cells / Batteries... 1 Upholstery... 1 MAQUET products... 1 Disposal... 2 Within the European Economic Community... 2 Outside the European Economic Community... 2 How to use these operating instructions... 2 General... 2 Abbreviations... 2 Symbols... 3 Order number... 3 Cross-references... 3 Actions and responses... 3 Buttons and menus... 3 Definitions... 4 Design of safety notes... 4 Design for other notes... 4 Definition for 3-dimensional coordinate system... 5 Definition of slope and tilt... 5 Definition of permissible overall load... 6 Definition of hazardous location, Zone AP-M... 6 Definition Positioning- / Transportposition... 6 Symbols used... 7 Pictorial guide for the MAGNUS 1180.01 operating table system... 9 Pictorial guide – Basic components... 9 Pictorial guide – Columns... 10 Pictorial guide – Table top modules... 11 Pictorial guide – Hand controls... 12 Pictorial guide – Transporter (1180.65XX)... 13 Use in accordance with the intended purpose... 14 Applicable standards... 14 Intended purposes... 15 Operating table system MAGNUS 1180.01... 15 Column... 15 Stationary transformer unit (1150.80A0)... 15 Mobile transformer unit (1180.81A0/B0/C0)... 15 Table top... 16 Side rails... 16 Control units... 16 Charging unit / charging station... 16 Transporters... 17 Battery charging station (1009.74X0)... 17
2 2.1 2.2 2.3
Fundamental safety notes Personal safety notes... 18 Safety notes for the product... 23 Safety notes regarding the use of accessories... 24
MAGNUS 1180.01 GA 1180.01 EN 16
I
Table of contents
3 Operation 3.1 Columns... 25 3.1.1 General... 25 3.1.1.1 Motor-powered adjustments... 25 3.1.1.2 IR system code... 25 3.1.1.3 Override control panel... 26 3.1.2 Stationary column (1180.01AX/BX)... 27 3.1.2.1 General... 27 3.1.2.2 Rotate the stationary column... 27 3.1.3 Mobile column (1180.01C0) / independently manoeuvrable column (1180.01D0)... 28 3.1.3.1 General... 28 3.1.3.2 Potential equalisation... 28 3.1.3.3 Optical indicators... 29 3.1.3.4 Switching on the mobile / independently manoeuvrable column... 30 3.1.3.5 Battery operation... 31 3.1.3.6 Charging the rechargeable battery (operation on mains power)... 32 3.1.3.7 Moving the mobile column... 33 3.1.3.8 Independently manoeuvrable column (1180.01D0)... 34 3.2 Table top modules... 38 3.2.1 General... 38 3.2.1.1 Avoiding collisions... 38 3.2.1.2 Planning surgery... 39 3.2.1.3 Patient positioning... 39 3.2.1.4 Patient orientation... 41 3.2.2 Table width extenders 1001.75A0/76A0... 42 3.2.3 Module mounting points... 43 3.2.3.1 General... 43 3.2.3.2 Basic mounting point... 44 3.2.3.3 Joint mounting point... 45 3.2.3.4 Back plate mounting point... 45 3.2.3.5 Head rest mounting point... 46 3.2.4 Joint module (1180.11X0)... 47 3.2.4.1 Attaching the joint module... 47 3.2.4.2 Removing the joint module... 49 3.2.5 Back plate (1180.31X0)... 50 3.2.5.1 Attaching / removing the back plate... 50 3.2.6 Leg plates, pair (1180.54X0)... 51 3.2.6.1 Attaching / removing the leg plates... 51 3.2.6.2 Abducting the thigh plate... 52 3.2.6.3 Attaching / removing the calf plate... 53 3.2.6.4 Abducting the calf plate... 53 3.2.6.5 Folding down / raising the calf plate... 54 3.2.6.6 Folding down the calf plate from the 90° position... 54 3.2.7 Transfer board (1180.57X0)... 55 3.2.7.1 Attaching / removing the transfer board... 55 3.2.8 Extension plate (1180.32X0)... 56 3.2.8.1 Attaching / removing the extension plate... 56 3.2.9 Head rest (1180.53X0)... 57 3.2.9.1 Attaching / removing the head rest... 57 3.2.9.2 Adjusting the head plate... 58 3.2.10 Padding... 59 3.2.10.1 General... 59 3.2.10.2 PUR padding... 59 3.2.10.3 SFC pads... 60 3.2.11 Side rails... 61 3.3 Control units... 62 1180.01 II MAGNUS GA 1180.01 EN 16
Table of contents
3.3.1 General... 62 3.3.2 Attaching the control unit to the side rail... 63 3.3.3 User interface... 64 3.3.3.1 Switch on illumination... 65 3.3.3.2 Selector button [Patient position]... 66 3.3.3.3 Switch over button [Leg side]... 67 3.3.3.4 Motorised adjustment of the table top... 68 3.3.3.5 Aligning the patient horizontally... 69 3.3.3.6 Sloping the patient... 70 3.3.3.7 Lowering / raising the patient (column)... 71 3.3.3.8 Tilting the patient... 72 3.3.3.9 Shifting the patient longitudinally... 74 3.3.3.10 Deactivate the lock function temporarily... 75 3.3.4 Display... 76 3.3.4.1 General... 76 3.3.4.2 Display design... 76 3.3.4.3 Symbols for status bar... 77 3.3.4.4 Symbols for the navigation bar... 77 3.3.4.5 Standard patient positions... 79 3.3.4.6 Menu item [System information]... 80 3.3.4.7 [Patient positions] menu... 81 3.3.4.8 [Transfer] menu... 84 3.3.4.9 [Settings] menu... 85 3.3.4.10 [Fast memory] menu... 88 3.3.5 IR remote control (1180.91A0)... 89 3.3.5.1 General... 89 3.3.5.2 Acoustic signals... 89 3.3.5.3 IR code... 89 3.3.5.4 Transmission power... 89 3.3.6 Charging unit / Charging station... 90 3.3.6.1 General... 90 3.3.6.2 Mobile charging unit... 90 3.3.6.3 Stationary charging station... 91 3.3.6.4 Recharging the IR remote control... 92 3.3.6.5 Removing the IR remote control... 92 3.3.7 Corded hand control (1180.90A0)... 93 3.3.7.1 Connecting / unplugging the corded hand control... 93 3.3.8 Foot switch (1009.81G0/G1/G2)... 94 3.4 Transporter (1180.63X0 / 1180.64X0 / 1180.65XX)... 95 3.4.1 General... 95 3.4.2 Locking / unlocking the transporter... 95 3.4.3 Moving the transporter... 96 3.4.4 Switch button for table top transfer / column transport... 97 3.4.5 Transporter (1180.65XX)... 98 3.4.5.1 Adjusting the transporter height... 98 3.4.6 Transporter (1180.64X0 / 1180.65XX)... 99 3.4.6.1 Storing the corded hand control... 99 3.4.6.2 Sloping the table top electrically... 100 3.4.6.3 Replacing the battery... 101 3.4.7 Table top transfer... 102 3.4.7.1 General... 102 3.4.7.2 Table top transfer from transporter to column... 103 3.4.7.3 Table top transfer from column to transporter... 104 3.4.7.4 Moving the mobile column... 106 3.5 Explanation of the directions for use... 107 3.5.1 Lock the stationary column (1180.01AX/BX)... 107 MAGNUS 1180.01 GA 1180.01 EN 16
III
Table of contents
3.5.2 3.5.3 3.5.4 3.5.5 3.5.5.1 3.5.5.2 3.5.5.3 3.5.6
Tilt indicator of the operating table (1180.01C0)... 108 Tilt indicator of the operating table (1180.01D0)... 109 Transport / positioning height (1180.01D0)... 110 Extending / retracting the swivel castors of the independently manoeuvrable column (1180.01D0). . 110 Release function "Extending swivel castors"... 110 No tilting with extended swivel castors... 111 No longitudinal shift with extended swivel castors... 111 Switch button for "table top transfer / column transport"... 112
4 4.1 4.2 4.2.1 4.3 4.3.1 4.3.2 4.3.3 4.3.4
Patient positioning General... 113 Patient positioning (250 kg - 380 kg)... 113 Table top configuration for an overall load of 250 kg - 380 kg... 115 Special patient positions (250 kg - 320 kg)... 116 General... 116 Laparoscopic adiposity surgery position, standing, with abducted leg plates... 116 Laparoscopic adiposity surgery position, sitting (Variant I)... 117 Laparoscopic adiposity surgery position, sitting (Variant II)... 118
5 5.1 5.1.1 5.1.2 5.1.3 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.3 5.3.1 5.3.2 5.3.3 5.3.4 5.4 5.4.1 5.4.2 5.4.3 5.4.4
Hybrid operating table General... 119 Symbols for status bar... 120 Operating mode... 120 Examination mode... 120 Hybrid operating table in conjunction with PHILIPS angiography system... 121 General... 121 Examination mode... 121 Lock-in position... 122 Table top configurations... 122 Hybrid operating table in conjunction with SIEMENS angiography system... 123 General... 123 Examination mode... 123 Lock-in position... 124 Table top configurations... 125 Hybrid operating table in conjunction with TOSHIBA angiography system... 126 General... 126 Examination mode... 126 Lock-in position... 127 Table top configurations... 127
6 6.1 6.1.1 6.2 6.3
Display notes General... 128 Structure of display notes... 128 Notes on operation / special notes on operation... 128 Warning notes / Status messages... 130
1180.01 IV MAGNUS GA 1180.01 EN 16
Table of contents
7 7.1 7.1.1 7.1.2 7.1.3 7.1.4 7.2 7.2.1 7.2.2 7.3 7.3.1 7.3.2 7.3.3
Cleaning and disinfection General... 133 Basic notes... 133 No mechanical cleaning and disinfection... 134 Stainless steel surfaces... 135 Padding... 135 Cleaning... 136 General... 136 Cleaning procedure... 136 Disinfection... 137 General... 137 Suitable disinfectants... 137 Disinfection procedure... 138
8 8.1 8.2 8.3 8.3.1 8.3.2 8.3.3 8.3.4 8.3.5 8.3.6 8.4
Inspections Visual and functional inspections... 139 Inspection and Maintenance... 140 Malfunctions and troubleshooting... 141 General... 141 Operating table... 142 Transporters... 144 Mobile charging unit... 144 Mobile transformer unit... 145 IR remote control... 145 Repair... 146
MAGNUS 1180.01 GA 1180.01 EN 16
V
Table of contents
9 9.1 9.2 9.2.1 9.2.2 9.2.2.1 9.2.2.2 9.2.2.3 9.2.2.4 9.2.3 9.3 9.3.1 9.3.2 9.3.2.1 9.3.2.2 9.3.2.3 9.3.2.4 9.3.3 9.3.3.1 9.3.4 9.4 9.4.1 9.4.2 9.4.2.1 9.4.2.2 9.4.2.3 9.4.3 9.4.3.1 9.4.3.2 9.4.3.3 9.5 9.5.1 9.6 9.6.1 9.7 9.7.1 9.7.2
Technical specifications Ambient conditions... 147 Operating table... 147 Slope and tilt... 147 Height adjustment range... 148 Height adjustment range of stationary column (1180.01AX)... 148 Height adjustment range of stationary column (1180.01BX)... 148 Height adjustment range of mobile column (1180.01CX)... 148 Height adjustment range of independently manoeuvrable column (1180.01DX)... 148 Radiotranslucent area... 149 Table top modules... 151 Dimensions... 151 Motor-powered adjustment ranges... 152 Table top... 152 Joint module... 154 Back plate... 154 Motor-driven adjustment of the leg plate / thigh plate... 155 Manual adjustment ranges... 155 Calf plate... 155 Weights... 156 Columns... 156 General... 156 Stationary column (1180.01AX/BX)... 157 General specifications... 157 Dimensions... 157 Stationary transformer unit (1150.80A0)... 158 Mobile / independently manoeuvrable column... 159 Mobile column (1180.01C0)... 159 Independently manoeuvrable column (1180.01D0)... 160 Mobile transformer unit (1180.81A0/B0/C0)... 160 Mobile charging unit (1009.70A0)... 161 Electrical specifications... 161 Stationary charging unit (1009.71A0)... 161 Electrical specifications... 161 Transporter (1180.6XXX)... 162 Dimensions... 162 Weight... 163
1180.01 VI MAGNUS GA 1180.01 EN 16
Table of contents
10 Approved accessories and spare parts 10.1 General... 164 10.2 Table top modules... 165 10.2.1 Table top modules, overall load up to 380 kg... 165 10.2.1.1 Table top modules with basic mounting point... 165 10.2.1.2 Table top modules with joint mounting point... 165 10.2.1.3 Table top modules with back plate interface... 166 10.2.1.4 Table top modules with head plate interface... 166 10.2.2 Table top modules, overall load up to 250 kg... 166 10.2.2.1 Table top modules with basic mounting point... 166 10.2.2.2 Table top modules with joint mounting point... 166 10.2.2.3 Table top modules with back plate interface... 167 10.2.2.4 Table top modules with head rest interface... 167 10.2.3 Table top modules, overall load up to 180 kg... 168 10.2.3.1 Table top modules with joint mounting point... 168 10.3 Accessories – Control units... 168 10.4 Accessories Transporters... 169 10.4.1 Table top modules, overall load up to 380 kg... 169 10.4.2 Table top modules, overall load up to 250 kg... 169 10.5 Accessories for side rails... 169 10.5.1 General... 169 10.5.2 Side rail accessories... 170 10.6 Special-purpose accessories... 171 10.7 Spare parts... 172
MAGNUS 1180.01 GA 1180.01 EN 16
VII
Table of contents
1180.01 VIII MAGNUS GA 1180.01 EN 16
Introduction Foreword
1
Introduction
1.1
Foreword Your facility has selected the leading-edge medical technology made by MAQUET. We sincerely appreciate the trust you have placed in us. MAQUET is a member of the GETINGE group which is consistently directing its attention to pioneering medico-technical solutions.
1.2
Environmental protection
1.2.1
Packaging
1
MAQUET is one of the world’s leading suppliers for emergency rooms, operating rooms and intensive care units. MAQUET has been standing for innovation and advance in medical technology ever since it was founded in 1838. Solutions relevant to the needs of practice and customer-oriented services optimise working cycles and boost economy in hospitals – all to the benefit of the patient.
The packaging is made of materials compatible with the environment. MAQUET will dispose of the packaging materials upon request. 1.2.2
Rechargeable cells / Batteries These can be turned in to your local disposal system for proper handling.
1.2.3
Upholstery Upholstery can be disposed of with normal household wastes.
1.2.4
MAQUET products MAQUET will take back used products or those which are no longer in service. Please contact your MAQUET representative for more detailed information.
MAGNUS 1180.01 GA 1180.01 EN 16
1
1
Introduction How to use these operating instructions
1.2.5
Disposal
1.2.5.1
Within the European Economic Community This product is governed by the 2002/96/EU Directive (Directive on Waste Electrical and Electronic Equipment). This product has not been registered for use in private households; disposal using municipal
1.2.5.2
collection points for used electrical equipment is not permitted. Please contact your MAQUET representative for more detailed information on the correct and legal disposal.
Outside the European Economic Community When disposing of this product, ensure compliance with the applicable national regulations on the handling and disposal of used equipment.
1.3
How to use these operating instructions
1.3.1
General These operating instructions are provided to familiarise you with the features of this MAQUET product. They are subdivided into several chapters.
1.3.2
Please note: • Please read these operating instructions carefully and completely before using the product for the first time. • Always proceed in accordance with the information contained herein. • Store these operating instructions in a location near the product.
Abbreviations EC EMC EN IR INT IPS OR PUR SELV SFC VDE
1180.01 2 MAGNUS GA 1180.01 EN 16
European Community Electromagnetic compatibility European standard Infrared (remote control) Intermittent Internal Power Source Operating room Polyurethane integral foam Safety Extra Low Voltage Special Foam Core Verband der Elektrotechnik Elektronik Informationstechnik (Association for Electrical, Electronic & Information Technology)
Introduction How to use these operating instructions
1.3.3
Symbols
1.3.3.1
Order number
1
An "X" in the order number (e.g. 1122.33X4) is a placeholder for a number of variants. 1.3.3.2
Cross-references References to other pages in these operating instructions are identified with a double arrow symbol "".
1.3.3.3
Actions and responses The "" symbol identifies an action taken by the user while the "" symbol identifies the reaction that this will induce in the system.
1.3.3.4
Example: Turn on the light switch. Lamp lights up.
Buttons and menus Buttons and menus are enclosed in square brackets. Example: Press the [DOWN] button in the [Operation] menu.
MAGNUS 1180.01 GA 1180.01 EN 16
3
1
Introduction How to use these operating instructions
1.3.4
Definitions
1.3.4.1
Design of safety notes Pictogram
Descriptor
Text
DANGER!
Indicates a direct and immediate risk The text for the safety to persons, which may be fatal or note describes the type result in most serious injury. of risk and how to avert it.
WARNING!
Indicates a potential risk to persons or property which may result in health hazard or grave property damage.
CAUTION!
Indicates a potential risk to property which may result in property damage.
Fig. 1: Design of safety notes
1.3.4.2
Design for other notes Notes not referring to personal injury or property damage are used as follows: Pictogram
Descriptor
Reference to
NOTE
Supplementary assistance or further useful information.
ENVIRONMENT
Proper disposal.
Fig. 2: Design for other notes
1180.01 4 MAGNUS GA 1180.01 EN 16
Introduction How to use these operating instructions
1.3.4.3
1
Definition for 3-dimensional coordinate system Reference
X axis
Y axis
Z axis
Product
Longitudinal direction
Lateral direction
Height
Patient
Longitudinal
Transverse
Sagittal
Neutral
Horizontal
Horizontal
Vertical
Fig. 3: Definition of terms for the 3-dimensional coordinate system 1 Frontal plane (horizontal plane) 2 Sagittal plane
1.3.4.4
3 Transverse plane
Definition of slope and tilt
Fig. 4: Definition of slope and tilt 1 Reverse Trendelenburg (foot down) 2 Trendelenburg (head down)
3 Tilt 4 Slope
MAGNUS 1180.01 GA 1180.01 EN 16
5
1
Introduction How to use these operating instructions
1.3.4.5
Definition of permissible overall load The "permissible overall load" is calculated by adding the weight of the patient and the weight of accessories on the side rails. The "permissible overall load" is the load which can be placed on the table top.
1.3.4.6
Restrictions might result from the components table top and transporter for which other overall loads may be valid, or from special patient positions.
Definition of hazardous location, Zone AP-M
NOTE The medical environment is designated as "Zone AP-M" (1).
1
Fig. 5: Hazardous location, Zone AP-M
1.3.4.7
Definition Positioning- / Transportposition For moving the independently manoeuvrable operating table (1180.01D0), differentiation is made between moving it with and without patient. Positioning position Moving the independently manoeuvrable operating table with patient is only permitted within the operating theatre under the following conditions. The independently manoeuvrable operating table must be in the positioning position, i.e. lateral tilt and longitudinal shift are reset and the table top height is restricted. The independently manoeuvrable operating table is not approved for patient transfer.
1180.01 6 MAGNUS GA 1180.01 EN 16
Transport position Moving the independently manoeuvrable operating table without patient is only permitted within the hospital under the following conditions. The independently manoeuvrable operating table must be in the transport position, i.e. lateral tilt, slope, motor-powered leg plate adjustment and longitudinal shift are reset and the table top height is restricted.
Introduction How to use these operating instructions
1.3.5
1
Symbols used Symbols
Identification Labelling for Class I products, developed and marketed in compliance with Medical Device Directive 93/42/EU.
Labelling for devices incorporating a Type B applied part as defined in the IEC 60601-1 standard. Degree of protection against electric shock. Labelling in compliance with the IEC 60601-1 standard. Symbol for "Class II".
Labelling of Category AP equipment as per the IEC 60601-1 standard. Explosion protection by avoiding sources of ignition when using flammable blends of anaesthetics which are mixed with air, oxygen or nitrous oxide. Labelling as per IEC 60529 standard. Symbol for "splash protection".
Identification in accordance with standard IEC 60529. Symbol for "protection against touching components under tension (larger than 1 mm diameter)" and "protection against vertically falling drip water". Identification in accordance with standard IEC 60529. Symbol für "unspecified protection".
Internal Power Source
Labelling for intermittent operation, i. e., if the product is continuously operated for time "x", the product may not then be operated for time"y". E. g. int 10 / 20 means that the product may not be used/moved/dismantled for 20 minutes after 10 minutes of uninterrupted use/movement. Labelling in compliance with the IEC 60601-1 standard. Symbol for "Potential equalisation".
Labelling in compliance with the EN 980 standard. Symbol for "Serial number".
Fig. 6: Symbols (Part 1 of 2)
MAGNUS 1180.01 GA 1180.01 EN 16
7
1
Introduction How to use these operating instructions
Symbols
Identification Labelling in compliance with the EN 980 standard. Symbol for "Manufacturing date".
Labelling in compliance with the IEC 60601-1 standard. Symbol for "Observe the accompanying documents".
Labelling as per 2002/96/EU Directive (Directive on Waste Electrical and Electronic Equipment). Symbol for "Do not dispose of at the municipal collection points for used electrical equipment". Packaging label. Symbol for "Keep dry".
Packaging label. Symbol for "Fragile! Handle with care".
Packaging label. Symbol for "Top".
Transportation label. Symbol for "Temperature limitations".
Transportation label. Symbol for "Relative humidity".
Transportation label. Symbol for "Atmospheric pressure".
Cleaning Label. Symbol for "Do not splash with water".
Fig. 6: Symbols (Part 2 of 2)
1180.01 8 MAGNUS GA 1180.01 EN 16
Introduction Pictorial guide for the MAGNUS 1180.01 operating table system
1.4
Pictorial guide for the MAGNUS 1180.01 operating table system
1.4.1
Pictorial guide – Basic components 2
1
1
8
5 7
2 2 2
5
3
9
4 6 10 11
12
Fig. 7: Pictorial guide – Basic components for MAGNUS 1 Table top (1180.10X0) 2 Basic mounting point 3 Positioning mark on the basic table top (Patient orientation) 4 Basic joint 5 Socket for hand controls on the basic supporting arm
6 Column 7 Slope saddle 8 Table top mount 9 Socket for hand controls on the column 10 IR receiver and transmitter 11 Override control panel 12 Transporter
MAGNUS 1180.01 GA 1180.01 EN 16
9
1 1.4.2
Introduction Pictorial guide for the MAGNUS 1180.01 operating table system
Pictorial guide – Columns
4
1
6 7 8
3
2
2
5 9
10
11
13 12
Fig. 8: Pictorial guide – Columns 1 Stationary column (1180.01AX) 2 Locking lever (column rotation) 3 Built-in base plate 4 Stationary column (1180.01BX) 5 Floor standing base plate 6 Mobile column (1180.01C0) 7 Indicator for battery charge level and recharging
1180.01 10 MAGNUS GA 1180.01 EN 16
8 Connection for potential equalisation cable 9 Socket for mobile transformer unit 10 Independently manoeuvrable column (1180.01D0) 11 Pump pedal 12 Castor cover 13 Mobile transformer unit (1180.81X0) for column 1180.01C0/D0