Page 1
Instructions for use 7000.01B0/F0 MEERA CL Mobile operating table
IFU 7000.01 EN 02 2020-04-28
Copyright notice All rights reserved. Any duplication, adaptation or translation without prior written consent is prohibited unless otherwise provided for in the relevant copyright laws. © Copyright MAQUET GmbH
Subject to technical modification! Due to further development of the product, the figures used and technical specifications given in these Instructions for Use may slightly differ from the current state of the product.
V02 02 28-04-2020
7000.01B0/F0 IFU 7000.01 EN 02
Contents
Contents 1
Introduction ...
9
1.1
How to use these operating instructions... 1.1.1 Abbreviations ... 1.1.2 Symbols and formatting ... 1.1.3 Definitions ... 1.1.3.1 Design of safety notes... 1.1.3.2 Structure of notes ... 1.1.3.3 Definition for 3-dimensional coordinate system... 1.1.3.4 Definition of inclination and tilt... 1.1.3.5 Definition of hazardous location, Zone AP-M ... 1.1.3.6 Definition of permitted overall load ... 1.1.3.7 Definition of protrusion ... 1.1.3.8 Definition Positioning- / Transporting ... 1.1.3.9 Definition of usage-related restrictions ... 1.1.3.10 Definition of patient orientation... 1.1.3.11 Definition of CENTRAL position ... 1.1.3.12 Definition of applied part...
9 9 9 11 11 11 12 12 13 13 13 13 14 14 15 16
1.2
Symbols used ...
17
1.3
Disposal ... 1.3.1 Old products... 1.3.2 Packaging ... 1.3.3 Batteries and rechargeable batteries ... 1.3.4 Pads and covers ... 1.3.5 Maquet products ... 1.3.6 Used electrical devices ...
20 20 20 20 20 20 20
1.4
Overview... 21 1.4.1 Meera CL OR table with optional accessories ... 21 1.4.2 Hand controls... 22
1.5
Basic requirements ... 1.5.1 Use in accordance with the intended purpose ... 1.5.2 Applicable standards... 1.5.3 Intended use MEERA CL (7000.01XX)... 1.5.4 Variants... 1.5.5 Control devices, optional... 1.5.6 Product features... 1.5.6.1 Essential performance... 1.5.6.2 Latex-free materials... 1.5.7 Reportable event...
2
Safety notes... 25
2.1
General safety notes ...
25
2.2
Safety notes for the OR table ...
27
2.3
Safety notes regarding service ...
29
7000.01B0/F0 IFU 7000.01 EN 02
23 23 23 23 23 24 24 24 24 24
3 / 132
Contents
2.4
Safety notes regarding the use of accessories...
30
2.5
Safety notes regarding padding...
31
2.6
Safety notes EMC...
32
3
Initial operation ... 33
3.1
Storage ...
33
3.2
Ambient conditions ...
33
3.3
Power supply ...
33
3.4
Connecting the service interface ...
34
3.5
IR code ... 35 3.5.1 Grouping of IR codes according to product groups ... 35
3.6
Venting the hydraulic oil ...
4
Hand controls and functions ... 37
4.1
Overview of control devices...
37
4.2
Mounting the control device to the side rail ...
38
4.3
Override control panel ... 38 4.3.1 Control buttons and functions ... 39
4.4
Corded hand controls ... 40 4.4.1 Connecting/removing corded control devices ... 40 4.4.2 Foot switch (1009.81J0/J1/J2) ... 41
4.5
Universal control device (1009.25A0)... 4.5.1 Notes on use... 4.5.2 Acoustic signals of the control device ... 4.5.3 Button assignment and functions...
42 42 43 43
4.6
Adjustment functions ... 4.6.1 Adjusting the height of the OR table ... 4.6.2 Adjusting the back plate... 4.6.3 Inclining the table top ... 4.6.4 Tilting the table top laterally ... 4.6.5 Moving the table top longitudinally... 4.6.6 Moving the table top to the horizontal position... 4.6.7 Deactivating the lock function temporarily ...
44 44 44 45 45 46 46 47
4.7
Operating menu ... 4.7.1 Display start screen ... 4.7.2 Symbols for status bar ... 4.7.3 Main menu [Menu] ... 4.7.4 Connect the OR table ... 4.7.4.1 Connecting a new OR table ... 4.7.4.2 Reconnecting the known OR table... 4.7.4.3 OR table is renamed ... 4.7.4.4 Disconnect the OR table ... 4.7.4.5 Show IR code ... 4.7.5 Menu [Settings OR table]... 4.7.5.1 Switch sound on/off ...
47 47 48 49 49 50 51 52 52 53 53 53
4 / 132
36
7000.01B0/F0 IFU 7000.01 EN 02
Contents
4.7.6
4.7.7 4.7.8 4.7.9
4.7.10
4.7.5.2 Display next maintenance ... Menu [Device Settings] ... 4.7.6.1 Set the brightness on the touchscreen... 4.7.6.2 Set the language ... 4.7.6.3 Resetting the control device ... 4.7.6.4 Calling up system information ... Set the patient orientation ... Select the preset patient position... User-defined patient positions ... 4.7.9.1 Save user-defined patient positions ... 4.7.9.2 Editing user-defined patient positions ... 4.7.9.3 Selecting a user-defined patient position ... 4.7.9.4 Quick saving user-defined patient positions... 4.7.9.5 Move to quick-save memory position ... OR table adjustment function or lock / unlock button...
54 54 54 55 55 57 57 59 60 60 60 61 62 63 64
5
Operation and use... 65
5.1
Overview OR table ...
65
5.2
OR table ... 5.2.1 Acoustic signals issued by the OR table... 5.2.2 Setting up equipotential bonding... 5.2.3 Status indicators mains connection / battery charge state... 5.2.3.1 Overview of status display for mains connection ... 5.2.3.2 Overview of status display for battery charge state... 5.2.4 Battery operation... 5.2.5 Charge batteries (mains operation) ... 5.2.6 Locking / moving the OR table... 5.2.6.1 Status display [LOCK] / [UNLOCK] ... 5.2.6.2 Lock operating table ... 5.2.6.3 Moving the OR table...
65 65 66 67 67 68 69 69 71 72 72 73
5.3
Table tops and accessories ... 5.3.1 Mounting the table width extensions (1001.75A0 / 76A0)... 5.3.2 Mounting / removing the head rest ... 5.3.2.1 Mounting and removing the head rest using the head rest adapter (1130.81A0) 5.3.3 Mounting and removing the extension plate (1131.31BC)... 5.3.4 Mounting and removing the seat plate extension (1131.55BC ) ... 5.3.5 Mounting / removing the leg plates ... 5.3.5.1 Mounting / removing the pair of leg plates (1133.53BC) ... 5.3.5.2 Mounting / removing the leg plate (1133.58BC)... 5.3.6 Removing / mounting pads ...
74 74 75 76 77 78 79 79 80 81
5.4
Explanation of instructions for use... 5.4.1 CENTRAL position... 5.4.2 Maximum height when moving the OR table with a total load of up to 250 kg ... 5.4.3 Displace / lock the OR table...
82 82 82 83
7000.01B0/F0 IFU 7000.01 EN 02
5 / 132
Contents
6
Approved accessories and table top configuration ... 84
6.1
Table top configuration for an overall load up to 155 kg... 6.1.1 NORMAL patient orientation / OR table can be moved (UNLOCK)... 6.1.2 REVERSE patient orientation/ OR table can be moved (UNLOCK) ... 6.1.3 NORMAL patient orientation/OR table locked (LOCK) ... 6.1.4 REVERSE patient orientation/OR table locked (LOCK) ...
86 86 88 90 92
6.2
Table top configuration with an overall load of 155-250 kg ... 6.2.1 NORMAL patient orientation / OR table can be moved (UNLOCK)... 6.2.2 REVERSE patient orientation / OR table can be moved (UNLOCK) ... 6.2.3 NORMAL patient orientation/OR table locked (LOCK) ... 6.2.4 REVERSE patient orientation/OR table locked (LOCK) ...
94 94 96 97 99
6.3
Table top configuration with an overall load of 250-454 kg ... 101 6.3.1 NORMAL patient orientation/OR table locked (LOCK) ... 101
6.4
Approved accessories ... 102 6.4.1 Maximum overall load up to 155 kg ... 102 6.4.1.1 Accessories for NORMAL mounting point up to 155 kg ... 102 6.4.1.2 Accessories for REVERSE mounting point up to 155 kg ... 103 6.4.2 Maximum overall load 155–250 kg ... 105 6.4.2.1 Accessories for NORMAL interface from 155–250 kg... 105 6.4.2.2 Accessories for REVERSE mounting point 155–250 kg ... 106 6.4.3 Maximum overall load 250–454 kg ... 107 6.4.3.1 Accessories for NORMAL interface from 250-454 kg ... 107 6.4.3.2 Accessories for REVERSE mounting point 250–454 kg ... 107 6.4.4 Hand controls... 108 6.4.5 Accessories for side rails ... 108
6.5
Projection... 108 6.5.1 Projection with a NORMAL patient orientation... 108 6.5.2 Projection with a REVERSE patient orientation... 109
7
Display notes... 110
7.1
Structure of display notes ... 110
7.2
Notes on use ... 110
7.3
Warning notes / Status messages ... 111
8
Cleaning and disinfection ... 113
8.1
General information ... 113 8.1.1 No mechanical preparation ... 114 8.1.2 Padding... 114
8.2
Cleaning agents and disinfectants... 115 8.2.1 Suitable cleaning agents... 115 8.2.2 Suitable disinfectants ... 115 8.2.3 Non-usable products / substances... 115
8.3
Prepare the OR table for cleaning ... 116
8.4
Preparation ... 116 8.4.1 Pre-cleaning... 116
6 / 132
7000.01B0/F0 IFU 7000.01 EN 02
Contents
8.4.2 8.4.3 8.4.4
Disinfection ... 116 Drying... 116 Inspections... 116
9
Maintenance ... 117
9.1
Visual and functional inspections ... 117
9.2
Faults and troubleshooting ... 119
9.3
Inspection and Maintenance... 119
9.4
Maintenance of corded hand controls ... 119
9.5
Repair ... 120
9.6
Type plate ... 120
10
Technical specifications... 122
10.1 General specifications ... 122 10.2 Ambient conditions ... 122 10.3 Surface temperature of application set ... 122 10.4 Noise level ... 122 10.5 Electrical specifications ... 122 10.6 Weight ... 123 10.7 Dimensions ... 123 10.8 Adjustment ranges... 124 10.8.1 Longitudinal shift ... 124 10.8.2 Inclination... 124 10.8.3 Tilt ... 125 10.8.4 Back plate ... 125 10.9 Table top positions ... 126 10.9.1 FLEX position... 126 10.9.2 REFLEX position... 126 10.10Electromagnetic compatibility (EMC)... 127 10.10.1 Cable lengths ... 127 10.10.2 Electromagnetic emissions ... 127 10.10.3 Resistance to electromagnetic interference... 127
Index... 129
7000.01B0/F0 IFU 7000.01 EN 02
7 / 132
Contents
8 / 132
7000.01B0/F0 IFU 7000.01 EN 02
Introduction How to use these operating instructions
1
Introduction
1.1
How to use these operating instructions
1
These operating instructions are provided to familiarise you with the features of this product. The operating instructions are divided into separate chapters. Please note: • Read these operating instructions through carefully and completely before using the product for the first time. • Always proceed in accordance with the information provided in these operating instructions. • Store these operating instructions in the vicinity of the product.
1.1.1
Abbreviations EC EMC EN EEC HF IEC INT IP IPS IR ISO LED MDD OR table PUR RF SELV SFC SN UL UPS
1.1.2
European Community Electromagnetic compatibility European standard European Economic Community High Frequency International Electrotechnical Commission Intermittent International Protection (type of protection against ingress of solid bodies and liquids) Internal Power Source Infrared International Organization for Standardization Light-Emitting Diode Medical Devices Act Operating table Polyurethane integral foam Radio frequency Safety Extra Low Voltage Soft Foam Core (special foam core) Serial no. Underwriters Laboratories Inc. Uninterrupted Power Supply
Symbols and formatting Symbol
Meaning
1. 2.
Instructions to follow / list with numbered steps Result of an action
Tab. 1:
7000.01B0/F0 IFU 7000.01 EN 02
Symbols and formatting
9 / 132
1
Introduction How to use these operating instructions
Symbol
Meaning
●
Numbered steps / List entry / precondition Reference to other pages within this document
[...]
Key / Module / Mode
bold
Menu / on-screen button
[italics]
Field to be filled in
1122.33XX
Order number with different variants (XX)
Tab. 1:
10 / 132
Symbols and formatting
7000.01B0/F0 IFU 7000.01 EN 02
Introduction How to use these operating instructions
1.1.3
Definitions
1.1.3.1
Design of safety notes Pictogram
Tab. 2:
1.1.3.2
1
Descriptor
Text
DANGER!
Identifies an immediate danger to people, which may result in death or serious injuries.
WARNING!
Identifies a potential danger to people or property, which may result in damage to health or serious property damages.
CAUTION!
Identifies a potential danger to property, which may result in property damages.
Design of safety notes
Structure of notes Pictogram
Tab. 3:
7000.01B0/F0 IFU 7000.01 EN 02
Descriptor
Explanation
NOTE
Supplementary assistance or further useful information which does not indicate a risk of injury to persons or a risk of property damage are described in the text of the note.
ENVIRONMENT
Information regarding proper disposal.
Structure of notes
11 / 132
1
Introduction How to use these operating instructions
1.1.3.3
Definition for 3-dimensional coordinate system Reference
X axis
Y axis
Z axis
Product
Longitudinal direction
Lateral direction
Height
Patient
Longitudinal
Transverse
Sagittal
Neutral
Horizontal
Horizontal
Vertical
Fig. 1:
1.1.3.4
1
Frontal plane (horizontal plane)
2
Sagittal plane
3
Transverse plane
Definition of inclination and tilt
Fig. 2:
12 / 132
Definition of terms for the 3-dimensional coordinate system
Definition of inclination and tilt
1
Reverse Trendelenburg
3
Lateral tilt
2
Trendelenburg (head down)
4
Inclination
7000.01B0/F0 IFU 7000.01 EN 02
Introduction How to use these operating instructions
1.1.3.5
1
Definition of hazardous location, Zone AP-M The term "AP-M zone" 1 is used to refer to the medical environment.
1
Fig. 3:
1.1.3.6
Area with a risk of explosions, AP-M zone
Definition of permitted overall load The maximum permitted overall load is derived by adding the patient weight, side rail accessory weights and weight of positioning aids. The maximum permitted overall load is the maximum load that may be placed on the table top. Restrictions may result from special patient positioning devices or the accessories used for which other weight loads may apply.
1.1.3.7
Definition of protrusion Protrusion is the gap between the mounting point(s) of a table top to the relevant outer edge of the table top components (e.g. head rest, leg plates) applied to the front. The maximum protrusion of a table top may not be exceeded.
1.1.3.8
Definition Positioning- / Transporting When moving, a distinction is made between moving the mobile operating table with a patient and without a patient. Positioning Positioning refers to the process of moving the mobile operating table with a patient and within the operating room. Transporting Transporting refers to the process of moving the mobile operating table without a patient in the operating room.
7000.01B0/F0 IFU 7000.01 EN 02
13 / 132
1
Introduction How to use these operating instructions
1.1.3.9
Definition of usage-related restrictions As of certain overall load thresholds and when moving the mobile operating table, one or more of the following usage-related restrictions apply: • Use of accessories • Protrusion • Adjustment functions • Patient orientation • Moving the operating table The specific usage-related restrictions are listed in the chapter on tabletop configurations [8 Page 84] in the appropriate sub-chapters.
1.1.3.10
Definition of patient orientation
WARN IN G ! Risk of injury! Incorrectly adjusted patient orientation may cause adjustment of the OR table in a direction that was not intended. Check the correct patient orientation prior to making any adjustments. The patient orientation is indicated in the status bar on the display on the hand control. The patient orientation is based on the position of the patient on the table compared to the OR table base. NORMAL patient orientation The upper part of the patient's body is located above the longer section of the OR table base 1.
1
Fig. 4:
14 / 132
NORMAL patient orientation
7000.01B0/F0 IFU 7000.01 EN 02
Introduction How to use these operating instructions
1
REVERSE patient orientation The legs are located above the longer section of the OR table base 1 .
1
Fig. 5:
1.1.3.11
REVERSE patient orientation
Definition of CENTRAL position 1
2
Fig. 6:
CENTRAL position
With an overall load of 250 kg, the OR table may only be used if the OR table is in the CENTRAL position: The longitudinal shift of the OR table is lifted and the centre table top bar 1 is above the column 2 . The table top stops at the CENTRAL position during a longitudinal shift. depending on the OR table used, the longitudinal shift is then automatically continued or must be continued by pressing the button once again.
7000.01B0/F0 IFU 7000.01 EN 02
15 / 132
1
Introduction How to use these operating instructions
1.1.3.12
Definition of applied part
Fig. 7:
Applied part, OR table: Table top
The applied part of the OR table is the table top.
16 / 132
7000.01B0/F0 IFU 7000.01 EN 02
Introduction Symbols used
1.2
1
Symbols used Symbols are attached to products, type plates and packaging. Symbols
Labelling Labelling of products developed and marketed in accordance with relevant European legal provisions.
UL classification mark from Underwriters Laboratories as proof that the product has been assessed by Underwriters Laboratories for specific properties in order to exclude risks and to confirm the usability under certain circumstances. This labelling signifies compliance with the requirements both for the USA and for Canada. Labelling in accordance with the standard ISO 15223-1. Symbol for "Catalogue number / product number".
Labelling in accordance with the ISO 15223-1 standard. Symbol for "Serial number".
Symbol for the labelling of medical devices
Labelling in accordance with the standard ISO 15223-1. Symbol for "Name and address of the manufacturer". The date of manufacturing can be combined with this symbol. Labelling in accordance with the ISO 15223-1 standard. Symbol for "Consult instructions for use".
Marking according to the standard ISO 15223-1. Symbol for "Pay attention to the supplied documents".
Labelling in accordance with the IEC 60601-1 standard. Symbol for "Follow Instructions for use".
Tab. 4:
7000.01B0/F0 IFU 7000.01 EN 02
Symbols
17 / 132
1
Introduction Symbols used
Symbols
Labelling Labelling of devices with an applied part of Type B in accordance with the IEC 60601-1 standard. Level of protection against electric shock. Labelling in accordance with the IEC 60601-1 standard. Symbol for "Class II Equipment"
Labelling in accordance with the 2012/19/EU directive (on used electrical equipment and electronics). Symbol for "Do not dispose of product via the municipal collection points for used electrical equipment". Labelling in compliance with the IEC 60529 standard. Symbol for "Splash protection".
Labelling in compliance with the IEC 60601-1 standard. Symbol for "Equipotentiality".
Labelling of devices in the AP class in accordance with the IEC 60601-1 standard. Explosion protection ensured by the avoidance of ignition sources when using flammable blends of anaesthetics that are mixed with air, oxygen or nitrous oxide. Marking in compliance with the standard ISO 7010 Symbol for “warning concerning injury to hands e.g. Hazard of crushing, shearing Labelling in accordance with the ISO 15223-1 standard. Labelling of packaging materials. Symbol for "Keep dry". Labelling in accordance with the ISO 15223-1 standard. Symbol for "Fragile! Handle with care".
Labelling in accordance with the ISO 7000 standard. Symbol for "Top".
Tab. 4:
18 / 132
Symbols
7000.01B0/F0 IFU 7000.01 EN 02
Introduction Symbols used
Symbols
1
Labelling Labelling in accordance with the ISO 15223-1 standard. Symbol for "Temperature limit".
Labelling in accordance with the ISO 15223-1 standard. Symbol for "Humidity limitation".
Labelling in accordance with the ISO 15223-1 standard. Symbol for "Atmospheric pressure limitation".
Tab. 4:
7000.01B0/F0 IFU 7000.01 EN 02
Symbols
19 / 132
1
Introduction Disposal
1.3
Disposal
1.3.1
Old products Getinge will take back used products or those which are no longer in service. For further information, please contact your personal Getinge representative. Used products or parts thereof may be contaminated. In order to prevent a potential infection, the product must be cleaned and disinfected prior to its return/disposal. The national regulations and disposal regulations must be observed for all disposal measures.
1.3.2
Packaging The packing materials are made of materials compatible with the environment. The packing material may be disposed of by Getinge on request.
1.3.3
Batteries and rechargeable batteries Rechargeable batteries/batteries can be submitted to your regional disposal system.
ENVI RO NMEN T Defective rechargeable batteries must be recycled in accordance with guideline 2006/66/EC. Defective rechargeable batteries may not be opened, disposed of in household waste, burned or thrown in water. Defective rechargeable batteries should be returned to local collection points.
1.3.4
Pads and covers Pads and covers may be disposed of via the household waste.
1.3.5
Maquet products Maquet will take back used products or those which are no longer in service. Please contact your Maquet representative for more detailed information.
1.3.6
Used electrical devices Within the European Economic Community This product is within the scope of the validity of guideline 2012/19/EU (waste electrical and electronic equipment). This product is not registered for use in private households, it may also not be disposed of disposal via municipal collection points for waste electrical and electronic equipment. For further information on legally compliant disposal, please contact the assigned Getinge representative. Outside the European Economic Community When disposing of this product, ensure compliance with the applicable national regulations on the handling and disposal of used electrical equipment.
20 / 132
7000.01B0/F0 IFU 7000.01 EN 02