Masimo

Capnograph Systems

EMMA MEDACX Waveform Capnograph Quick Guide May 2016

Quick Guide

1 Page

EMMA® Waveform Capnograph Controls & Displays  Power & Airway Adapters  Battery Cover Release  Alarm Mute  Airway Adapter  EtC02 Value a  kP  Battery Status  On Button  Respiratory Rate Alarm Status  EtC02 Waveform  Power On: Insert Airway Adapter 1 Press Power on button 2 device ready 3 Power Off: Automatic On removal of Adapter 1 or 2 mins after 2 NO Breath detected and Alarm silenced 4  How to Zero device Battery Cover Release  3  Infant Airway Adapter  Battery types: Duracell Industrial 2 x AAA LR03 or Energizer Ultimate 2x AAA Lithium L92  [reduced deadspace 1 ml]  5  6  Note! Trained medical professional must determine correct airway adapter for each patient application.  Close Battery Cover  Alarms & Status Displays  2  kPa  kPa  kPa  kPa  3  1  EtC02 Low Alarm [setting] EtC02 High Alarm [setting] Press & Hold Power On 1 Press & Hold Alarm Mute 2 button for 5 secs. for button for 5 secs. Display changes as shown. Display changes as shown. Press Power button to 1 Press Alarm button 2 decrease High alarm. to increase Low alarm. Press 2 to increase Press 1 to decrease setting, when set; wait setting, when set; wait 5 secs device returns 5 secs device returns to zero 3 ready to use. to zero 3 ready to use. Alarm settings revert to default after device power off.  Alarm Priority: No Airway Adapter!  2  How to ZERO device NOTE! presence of ambient air [0% CO2] in the adapter is crucial for successful zero. Avoid breathing near device during zeroing process.  1  3  Clinical information kPa  2  4  EMMA should read 0.0 at power on. If it does NOT read 0.0 as shown 4 then insert NEW adapter. After inserting NEW adapter if device is NOT 0.0 but has offset 4 then the device needs re-zeroing.  Insert new adapter Press Power On 1 & Alarm 2 buttons simultaneously for 10 secs, then device counts down 10 to 0. When device flashes ‘0’ release both buttons 3 ready to use.  Adult/Paediatric Airway Adapter [deadspace 6 ml]  How to Set Alarms  1  Replace batteries  4  5  6  0  Batteries 1  Dotted line = EtC02 reached/exceed 7kPa kPa  Alarm Priority: Advisory! kPa  Alarm Priority: Caution!!! kPa  Normal C02 patient range 4.0 - 5.7 kPa Below 4.0 kPa is Hypocapnia Above 5.7 kPa is Hypercapnia EtC02 Inspiration Expiration  Normal waveform  Hyperventilation [decreasing C02]  Hypoventilation [increasing C02]  Alarm Priority: Advisory Clogged Adapter!  02392 469737 info@medacx.co.uk www.medacx.co.uk  Alarm Priority: Advisory Replace batteries!  Alarm Priority: Advisory Silenced!  Alarm Priority: Advisory Slienced Alarm has Cleared!  Apnea [loss of waveform]  142-CL-R1.0-MAY-16  MEDACX LIMITED • 1-3 ALEXANDER HOUSE • 60-62 STATION ROAD • HAYLING ISLAND • HAMPSHIRE • PO11 0EL
File Type: PDF
File Size: 1.51 MB
File Name: EMMA MEDACX Waveform Capnograph Quick Guide May 2016.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions