Instructions for Use
124 Pages
Preview
Page 1
EN 4–31
NL 32-59
FR 60-87
ID 88-115
Table of Contents 1. Intended Use / Contraindication / Population
5
2. Meaning of symbols
6
3. Important safety information
8
4. Product description
10
5. Cleaning
12
5.1 Before using for the first time and after every use
12
5.2 Before using for the first time and once a day
14
5.3 Cleaning the motor unit
15
6. Preparing for pumping
16
6.1 Mains operation
16
6.2 Battery operation
16
6.3 Assembling the pump set
18
7. Expression
20
7.1 P reparing for single pumping
20
7.2 Pumping
20
7.3 Preparing for hands-free expression with Easy Expression Bustier
22
7.4 P reparing for double pumping
24
8. Storing and thawing breast milk
26
8.1 Storage
26
8.2 Freezing
26
8.3 Thawing
26
9. Feeding breast milk
27
10. Troubleshooting
28
11. Warranty / disposal
29
12. Complete care during breastfeeding time
30
13. EMC / Technical description
116
14. Technical specifications
122
1. 1. Intended use / Population – Contraindication
5
The intended use and indications of breast pumps Breast pumps are intended to be used by lactating women in the hospital or home environment for expressing breast milk. Breast pumps are indicated to alleviate the symptoms of engorgement by expressing milk. In case of mastitis breast pumps support the healing process by removing breast milk from the affected breast. Breast pumps are indicated to relieve sore and cracked nipples and to bring out flat or inverted nipples. Also breast pumps enable mothers to provide breast milk for babies who cannot feed directly at the breast for a variety of reasons such as latch-on problems, cleft palate or premature babies. Intended patient population/user Adolescent paediatric or adult lactating women. Many women find it convenient, or even necessary, to use a breast pump to express and store their breast milk once they have returned to work, are travelling or are otherwise separated from their baby. Women are often delighted to learn that a breast pump can be used as a supplement to breastfeeding and that some pumps are designed to mimic the suckling of a nursing baby. Contraindications There are no known contraindications for the Swing maxi breast pump.
2. Meaning of symbols The warning symbol identifies all instructions that are important for safety. Failure to observe these instructions can lead to injury or damage to the breast pump! When used in conjunction with the following words, the warning symbol stands for:
Warning Can lead to serious injury or death.
Caution
Can lead to minor injury.
i
6
Note
i
Info
Can lead to material damage. Useful or important information that is not related to safety.
Symbols on the packaging This symbol indicates that the material is part of a recovery/recycling process. This symbol indicates a carton package. This symbol indicates to keep the device away from sunlight. This symbol indicates to handle the fragile device with care. This symbol indicates the temperature limitation for operation, transport and storage. This symbol indicates the humidity limitation for operation, transport and storage. This symbol indicates the atmospheric pressure limitation for operation, transport and storage. This symbol indicates to keep the device dry. This symbol indicates that the packaging contains products intended to come in contact with food according to regulation 1935/2004. This symbol indicates unique GSI Global Trade Item Numbers (GTIN) This symbol indicates do not dispose the device together with unsorted municipal waste (for EU only). This symbol indicates to follow instructions for use.
Symbols on the device This symbol indicates to follow instructions for use. This symbol indicates the compliance with the essential requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices.
This symbol indicates the manufacturer. This symbol indicates do not dispose the device together with unsorted municipal waste (for EU only). This symbol indicates the compliance with additional USA and Canada safety requirements for medical electrical equipment. This symbol indicates a type BF applied part. SN
This symbol indicates manufacturer's serial number of the device. This symbol indicates the positioning of battery cell. This symbol indicates the protection against ingress of solid foreign objects and against harmful effects due to the ingress of water. This symbol indicates the date of manufacture (four digits for the year and two digits for the month).
Symbols on the mains adapter This symbol indicates that the mains adapter is a class II device. This symbol indicates the compliance with China Compulsory Certification. This symbol indicates that the mains adapter is safety tested. This symbol indicates that the mains adapter is for indoor use only. This symbol indicates the compliance with USA and Canada safety requirements. This symbol indicates the compliance with Federal Communications Commission requirements. This symbol indicates polarity of d.c. power connector. N136
This symbol indicates the compliance with AUS/NZ regulatory requirements (Regulaltory compliance mark). This CE-mark indicates the compliance with the low voltage and electromagnetic compatibility directive. This symbol indicates to not dispose the device together with unsorted municipal waste (for EU only). The solid bar symbol indicates that mains adapter is put on the market after 13 August 2005. This symbol indicates the compliance with Japanese safety requirements. This symbol indicates the compliance with energy efficiency requirements. This symbol indicates alternating current. This symbol indicates direct current.
7
3. Important safety information
Failure to follow these instructions/safety information can lead to danger from the device. Subject to technical changes.
8
Device Danger of electrocution! Keep the device dry! Never immerse in water or other liquids! The Swing maxi breast pump is not heat-resistant: keep away from radiators and open flames. Do not expose the motor unit to direct sunlight. Repairs must be performed only by an authorised service agency Do not repair yourself! No modifications to the device are permitted. Never use a damaged device. Replace damaged or worn parts. MAX. 250 h
The operating life of the Swing maxi breast pump is 250 hours. The service life is two years.
Electrical use Separation from the mains is only assured through the disconnection of the mains adapter from the wall socket outlet. Keep the mains adapter away from heated surfaces. Do not reach for any electrical device if it has fallen into water. Unplug immediately. The breast pump should never be left unattended when plugged into a power source.
9
Use Use the Swing maxi breast pump only for its intended use as described in this manual. Never operate an electrical device if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Do not use the Swing maxi breast pump while bathing or showering.
Do not use the Swing maxi breast pump while sleeping or overly drowsy. This is a single user product. Use by more than one person may present a health risk. Do not drive whilst hands-free pumping. Supervision is necessary when the Swing maxi breast pump is used in the vicinity of children. Contact your lactation consultant or physician if you experience problems or pain. Portable and mobile radio frequency communications equipment can affect the Swing maxi breast pump. l Plastic bottles and component parts become brittle when frozen and may break when dropped. l Also, bottles and component parts may become damaged if mishandled, e.g. dropped, over-tightened, or knocked over. l Take appropriate care in handling bottles and components. l Do not use the breast milk if bottles or components become damaged.
4. Product description
10
Spare parts and accessories available for order can be found on page 30 2x PersonalFit™ Breast shield M (24mm) (for other breast shield sizes see Chapter 12, page 30)
2x Freestyle connectors (breast shield base, membrane, transparent cap)
2x bottle
2x bottle stand
1x Calma Solitaire
2x Calma multi lid
1x motor unit
11
LED On/Off button
Short tubing Tubing support
Reduce vacuum
Increase vacuum
Let-down button Fixing clip PVC tubing port
Battery compartment Power adapter port
Long tubing 1x Swing maxi tubing
1x mains adapter
5. Cleaning
Caution
12
lO nly use drinking-quality water for cleaning. l Take apart and wash all parts that come in contact with the breast and breast milk immediately after use to avoid dry up of milk residues and to prevent growth of bacteria.
5.1 B efore using for the first time and after every use
1
Disassemble the pump set into individual parts.
Note
i
l T he pump set requires no maintenance. l Take care not to damage parts of the pump set during cleaning. l If the individual components of the pump set are cleaned in a dish washer parts may be discoloured by food pigments. This has no impact on the function.
4
Rinse all parts with cold, clear water (approx. 20 °C) for 10 – 15 seconds.
13
2
3
Rinse all parts with cold, clear water (approx. 20 °C).
Clean all parts with plenty of warm soapy water (approx. 30 °C).
or As an alternative to steps 2, 3 and 4.
5
Dry with a clean cloth or leave to dry on a clean cloth.
If you clean the individual parts of the pump set in the dishwasher, place them on the top rack or in the cutlery section.
5. Cleaning
lO nly use drinking-quality water for cleaning. l Take apart and wash all parts that come in contact with the breast and breast milk immediately after use to avoid dry up of milk residues and to prevent growth of bacteria.
5.2 Before using for the first time and once a day
1 More information on page 12, chapter 5.1 steps 2–4
Caution
14
Disassemble the pump set into individual parts.
Note
i
l W hen boiling, a tea spoon of citric acid may be added to avoid a buildup of limescale. l S tore the pump set in a clean bag/ container until next use. Or store it in clean paper or a cloth.
3
Dry with a clean cloth or leave to dry on a clean cloth.
15
2a
Cover all parts with water and boil for five minutes.
or
2b
Use QuickClean* bags in the microwave in accordance with the instructions.
5.3 Cleaning the motor unit
1
Wipe off with a clean, damp cloth.
*More information at www.medela.com
6. Preparing for pumping
Warning
16
l r e 6.1 Mains operation: Follow the exact order of the steps.
6.1 Mains operation
1
l O nly use the mains adapter supplied with the Swing maxi. l M ake sure the voltage of the mains adapter is compatible with the power source.
Plug the mains adapter cord into the motor unit.
i
Info
l r e 6.2 Battery operation: T he batteries do not need to be removed when the main adapter is used for pumping. lR egularly check the condition of the batteries in the motor unit. l If Swing maxi will remain unused for a longer period of time, remove the batteries from the battery compartment. lB atteries last for two to three pumping sessions (approx. 1 ½ hours pumping time).
6.2 Battery operation
1
Open the battery compartment on the back in the direction of the arrow.
17
2
Plug the mains adapter into the mains socket.
2
3
Insert six AAA Micro 1.5 V batteries.
Close the battery compartment.
6. Preparing for pumping
Caution
18
l Wash hands thoroughly (at least one minute) with soap and water before touching the breast and pump parts.
1
Note
i
l Use Medela original accessories only. l C heck pump set components for wear or damage before use and replace if necessary. l A ll components must be completely dry before use.
i
6.3 Assembling the pump set
Carefully insert the light yellow membrane into the base of the breast shield.
4 Info
l Carry out all the steps with care and assemble the pump set correctly. Otherwise a good vacuum may not be achieved.
Screw bottle into connector.
19
2
3
Fasten the transparent cap to the connector. ➙ M ake sure that all three snaps (top and side) are engaged.
Push the breast shield onto the connector.
5
6
Insert the short tubing into the transparent cap as far as it will go.
Insert the long tubing into the motor unit.
7. Expression
Caution
20
l r e step 2 (chapter 7.1): Answer the following questions to find out whether the available breast shield size will fit: l Is your nipple moving freely in the tunnel? l Is minimal or no areolar tissue being pulled into the tunnel of the breast shield? l D o you see a gentle, rhythmical motion in the breast with each cycle of the pump? l D o you feel the breast emptying all over? l Is your nipple pain-free? If the answer to any of these questions is “No” or if you experience problems or pain during expression, consult your breastfeeding and lactation consultant or midwife.
7.1 Preparing for single pumping
1
Insert the unused short tubing into the tubing holder.
7.2 Pumping
1
Note
i
l r e step 3 (chapter 7.1): Do not hold the pump set by the bottle. This can lead to blockage of the milk ducts and engorgement. l W ipe the breast with a warm washcloth (do not use alcohol).
Switch on the breast pump with . ➙ T he stimulation phase lasts a maximum of two minutes. The stimulation phase will then automatically change to the expression phase.
21
2
1
Place the breast shield on your breast so that your nipple is properly centred in the tunnel.
2
1
If your milk starts to flow earlier, press the button to change to the expression phase. ➙ M ake sure that the milk is flowing into the bottle properly.
3
Hold the breast shield onto your breast with your thumb and index finger. Support your breast with the palm of your hand.
3
The vacuum can be adjusted in every phase. Comfort vacuum: Use to increase the vacuum until it is slightly unpleasant. Then press to dial it back minimally.
7. Expression
4
Caution
22
l C ontact your midwife or lactation consultant if you can express only minimal or no milk or if expression is painful.
Note
Switch off the breast pump with .
i
l A lways disconnect the Swing maxi from the power source after expression. l O nly fill the bottle to the 150 ml mark.
i
Info
l T he Swing maxi switches off automatically if the pump has been running for 30 minutes without any manipulations. l D o not kink the tubing during expression.
7.3 Preparing for hands-free expression with the Easy Expression Bustier*
1
Overview of LEDs lights up
On
does not light up
Off
even, regular flashing
Stimulation phase
light constantly on
Expression phase
rapid flashing
Min./Max. vacuum
Put on the Easy Expression Bustier and leave the zip open slightly.