Medela
Mini Electric Instructions for Use Rev D Sept 2014
Instructions for Use
168 Pages
Preview
Page 1
Mini Electric™ EN Instructions for use | DE Gebrauchsanweisung FR Mode d’emploi | IT Istruzioni per l’uso NL Gebruiksaanwijzing | ID Petunjuk penggunaan
BPA Bisphenol-A
free
EN 04–29
DE 30–55
FR 56–81
IT 82–107
NL 108–133
ID 134–159
Table of Contents
4
1. Intended use / Population – Contraindication
5
2. Meaning of symbols
6
3. Important safety information
8
4. Product description
10
5. Cleaning
12
5.1 Before using for the first time and after every use
12
5.2 Before using for the first time and once a day
14
5.3 Cleaning the motor unit
15
6. Preparing for pumping
16
6.1 Mains operation
16
6.2 Battery operation
16
6.3 Assembling the pump set
18
7. Expression
20
7.1 P reparing for pumping
20
7.2 Pumping
20
8. Storing and thawing breastmilk
24
8.1 Storage
24
8.2 Freezing
24
8.3 Thawing
24
9. Feeding breastmilk
25
10. Troubleshooting
26
11. Warranty / disposal
27
12. Complete care during breastfeeding time
28
13. EMC / Technical description
160
14. Technical specifications
167
1. Intended use / Population – Contraindication
5
The intended use and indications of breastpumps Breastpumps are intended to be used by lactating women in the hospital or home environment for expressing breastmilk. Breastpumps are indicated to alleviate the symptoms of engorgement by expressing milk. In case of mastitis breastpumps support the healing process by removing breastmilk from the affected breast. Breastpumps are indicated to relieve sore and cracked nipples and to bring out flat or inverted nipples. Also breastpumps enable mothers to provide breastmilk for babies who cannot feed directly at the breast for a variety of reasons such as latch-on problems, cleft palate or premature babies. Intended patient population/user Adolescent paediatric or adult lactating women. Many women find it convenient, or even necessary, to use a breastpump to express and store their breastmilk once they have returned to work, are travelling or are otherwise separated from their baby. Women are often delighted to learn that a breastpump can be used as a supplement to breastfeeding and that some pumps are designed to mimic the suckling of a nursing baby. Contraindications There are no known contraindications for the Mini Electric breastpump.
2. Meaning of symbols The warning symbol identifies all instructions that are important for safety. Failure to observe these instructions can lead to injury or damage to the breastpump! When used in conjunction with the following words, the warning symbol stands for:
Warning Can lead to serious injury or death.
Caution
Can lead to minor injury.
i
6
Note
i
Info
Can lead to material damage. Useful or important information that is not related to safety.
Symbols on the packaging This symbol indicates that the material is part of a recovery/recycling process. This symbol indicates a carton package. This symbol indicates to keep the device away from sunlight. This symbol indicates to handle the fragile device with care. This symbol indicates the temperature limitation for operation, transport and storage.
°C
This symbol indicates the humidity limitation for operation, transport and storage. This symbol indicates the atmospheric pressure limitation for operation, transport and storage. This symbol indicates to keep the device dry. This symbol indicates that the packaging contains products intended to come in contact with food according to regulation 1935/2004. This symbol indicates unique GSI Global Trade Item Numbers (GTIN) This symbol indicates do not dispose the device together with unsorted municipal waste (for EU only). This symbol indicates to follow instructions for use. This symbol indicates the date of manufacture (four digits for the year and two digits for the month).
Symbols on the device This symbol indicates to follow instructions for use. 0123
This symbol indicates the compliance with the essential requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices.
This symbol indicates the manufacturer. This symbol indicates do not dispose the device together with unsorted municipal waste (for EU only). This symbol indicates a type BF applied part. +
- This symbol indicates the positioning of battery cell.
IP22
This symbol indicates the protection against ingress of solid foreign objects and against harmful effects due to the ingress of water.
Symbols on the mains adapter This symbol indicates that the mains adapter is a class II device. This symbol indicates the compliance with China Compulsory Certification. This symbol indicates that the mains adapter is safety tested. This symbol indicates that the mains adapter is for indoor use only. This symbol indicates the compliance with Canada safety requirements. This symbol indicates the compliance with USA and Canada safety requirements. This symbol indicates the compliance with USA safety requirements. 125°C
This symbol indicates the mains adapter is fitted with thermal cut-out (number indicates cut-out temperature) This symbol indicates polarity of d.c. power connector. This symbol indicates isolating safety transformer. This CE-mark indicates the compliance with the low voltage and electromagnetic compatibility directive. This symbol indicates to not dispose the device together with unsorted municipal waste (for EU only). The solid bar symbol indicates that mains adapter is put on the market after 13 August 2005. This symbol indicates the compliance with Japanese safety requirements. This symbol indicates alternating current. This symbol indicates direct current.
9 VDC
This symbol indicates the compliance with the essential requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices.
7
3. Important safety information
Failure to follow these instructions/safety information can lead to danger from the device. Subject to technical changes.
8
Device Danger of electrocution! Keep the device dry! Never immerse in water or other liquids! The Mini Electric breastpump is not heat-resistant: keep away from radiators and open flames. Do not expose the motor unit to direct sunlight. Repairs must be performed only by an authorised service agency Do not repair yourself! No modifications to the device are permitted. Never use a damaged device. Replace damaged or worn parts. MAX. 150 h
The operating life of the Mini Electric breastpump is 150 hours. The service life is two years.
Electrical use Separation from the mains is only assured through the disconnection of the mains adapter from the wall socket outlet. Keep the mains adapter away from heated surfaces. Do not reach for any electrical device if it has fallen into water. Unplug immediately. The breastpump should never be left unattended when plugged into a power source.
9
Use Use the Mini Electric breastpump only for its intended use as described in this manual. Never operate an electrical device if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Do not use the Mini Electric breastpump while bathing or showering.
Do not use the Mini Electric breastpump while sleeping or overly drowsy. This is a single user product. Use by more than one person may present a health risk. Do not drive whilst hands-free pumping. Supervision is necessary when the Mini Electric breastpump is used in the vicinity of children. Contact your lactation consultant or physician if you experience problems or pain. Portable and mobile radio frequency communications equipment can affect the Mini Electric breastpump.
Important: l Plastic bottles and component parts become brittle when frozen and may break when dropped. l Also, bottles and component parts may become damaged if mishandled, e.g. dropped, over-tightened, or knocked over. l Take appropriate care in handling bottles and components. l Do not use the breastmilk if bottles or components become damaged.
4. Product description
10
Spare parts and accessories available for order can be found on page 28. 1x PersonalFit™ Breastshield M (24 mm) (for other breastshield sizes see Chapter 12, page 28)
1x PersonalFit™ connector 1x valve head
1x bottle
1x bottle stand
11
1x motor unit Power adapter port Vacuum regulator
2x valve membrane On/off slider button
1x protective cap
1x disc
1x lid
1x mains adapter
5. Cleaning
Caution
12
l O nly use drinking-quality water for cleaning. lT ake apart and wash all parts that come in contact with the breast and breastmilk immediately after use to avoid dry up of milk residues and to prevent growth of bacteria.
5.1 B efore using for the first time and after every use
1
Disassemble the pump set into individual parts.
Note
i
l T he pump set requires no maintenance. l Take care not to damage parts of the pump set during cleaning. l If the individual components of the pump set are cleaned in a dish washer parts may be discoloured by food pigments. This has no impact on the function.
4
Rinse all parts with cold, clear water (approx. 20 °C) for 10–15 seconds.
13
2
3
Rinse all parts with cold, clear water (approx. 20 °C).
Clean all parts with plenty of warm soapy water (approx. 30 °C).
or As an alternative to steps 2, 3 and 4.
5
Dry with a clean cloth or leave to dry on a clean cloth.
If you clean the individual parts of the pump set in the dishwasher, place them on the top rack or in the cutlery section.
5. Cleaning
lO nly use drinking-quality water for cleaning. l Take apart and wash all parts that come in contact with the breast and breastmilk immediately after use to avoid dry up of milk residues and to prevent growth of bacteria.
5.2 Before using for the first time and once a day
1 More information on page 12, chapter 5.1 steps 2–4.
Caution
14
Disassemble the pump set into individual parts.
Note
i
l W hen boiling, a tea spoon of citric acid may be added to avoid a buildup of limescale. l S tore the pump set in a clean bag/ container until next use. Or store it in clean paper or a cloth.
3
Dry with a clean cloth or leave to dry on a clean cloth.
15
2a
Cover all parts with water and boil for five minutes.
or
2b
Use QuickClean* bags in the microwave in accordance with the instructions.
5.3 Cleaning the motor unit
1
Wipe off with a clean, damp cloth.
*More information at www.medela.com
6. Preparing for pumping
Warning
16
l r e 6.1 Mains operation: Follow the exact order of the steps.
6.1 Mains operation
1
l O nly use the mains adapter supplied with the Mini Electric. l M ake sure the voltage of the mains adapter is compatible with the power source.
Plug the mains adapter cord into the motor unit.
i
Info
l r e 6.2 Battery operation: T he batteries do not need to be removed when the main adapter is used for pumping. I Regularly check the condition of the batteries in the motor unit. I If Mini Electric will remain unused for a longer period of time, remove the batteries from the battery compartment.
6.2 Battery operation
1
Remove the battery compartment cover.
17
2
Plug the mains adapter into the mains socket.
2
3
Insert two AA LR6 batteries.
Slide the cover back.
6. Preparing for pumping
Caution
18
l Wash hands thoroughly (at least one minute) with soap and water before touching the breast and pump parts.
1
Note
i
l Use Medela original accessories only. l C heck pump set components for wear or damage before use and replace if necessary. l A ll components must be completely dry before use.
i
6.3 Assembling the pump set
Carefully push the valve membrane onto the valve head until it engages.
4 Info
l Carry out all the steps with care and assemble the pump set correctly. Otherwise a good vacuum may not be achieved.
Screw the bottle onto the breastshield.
19
2
3
Push the breastshield onto the connector.
Push the valve head and membrane onto the connector. Position valve head laterally.
5
6
Insert the motor unit into the connector.
Rotate motor unit clockwise until the long battery compartment is located over the bottle.
7. Expression
Caution
20
l r e step 2 (chapter 7.1): Answer the following questions to find out whether the available breastshield size will fit: l Is your nipple moving freely in the tunnel? l Is minimal or no areolar tissue being pulled into the tunnel of the breastshield? l D o you see a gentle, rhythmical motion in the breast with each cycle of the pump? l D o you feel the breast emptying all over? l Is your nipple pain-free? If the answer to any of these questions is “No” or if you experience problems or pain during expression, consult your breastfeeding and lactation consultant or midwife.
7.1 Preparing for pumping
1
Place the breastshield on your breast so that your nipple is properly centred in the tunnel.
7.2 Pumping
1
Note
i
l r e step 2 (chapter 7.1): Do not hold the pump set by the bottle. This can lead to blockage of the milk ducts and engorgement. l W ipe the breast with a warm washcloth (do not use alcohol).
Set the vacuum control to minimum.
21
2
1
Hold the breastshield onto your breast with your thumb and index finger. Support your breast with the palm of your hand.
2
1
Switch on the breastpump. S lide the switch to Start.
3
Turn the vacuum control up towards MAX until it is slightly uncomfortable. Then turn down slightly towards MIN. M ake sure that the milk flows into the bottle properly.