MIDMARK
Progeny Dental Products and Systems
Ultra-series Dental Chairs Model 153592 and 153758 User Guide Rev S Oct 2012
User Guide
12 Pages
Preview
Page 1
User Guide
Midmark Ultra-series Dental Chairs Models:
153592 and 153758
Intended Use... 2 Electromagnetic Interference... 2 Transportation / Storage / Operating Conditions ... 2 Disposal of Equipment... 2 Symbols... 3 Touch Pad Location... 4 Power to the Chair... 4 Collision Protection System... 5 Chair Up / Down... 6 Back Up / Down... 6 Programming Chair Positions... 7 Rotating the Chair... 8 Adjusting the Headrest... 9 Barriers... 10 Cleaning Chair Upholstery... 10 Cleaning Procedures... 10 Specifications...11 Technical Library at Midmark.com Language of origin: English
Serial Number Label
DA2553i
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 1
Part No. 003-1107-00 Rev. S (10/29/12)
Compliance and Specifications
Disposal of Equipment At the end of this product’s life, the unit, accessories and other consumable goods may be contaminated from normal use. Consult local codes and ordinances for proper disposal of this equipment and other consumable goods.
Intended Use To provide patient support and positioning during dental exams.
Electromagnetic Interference Midmark dental operatory components are designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and this operatory, remove the interfering device from room and / or plug product into an isolated circuit.
Transportation / Storage / Operating Conditions Transportation / Storage Temperature:...23°F to 100°F (-5°C to 38°C) Relative Humidity:... 10% to 90% (non-condensing) Atmospheric Pressure:... 7.2 PSI to 15.3 PSI (50 kPa to 106 kPa) Operating Temperature Range: ...59°F to 95°F (15°C to 35°C)
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 2
Symbols These symbols appear on your equipment and/or in the manuals.
Fragile
warning
Indicates a potentially hazardous situation which could result in serious injury if not avoided.
Proper Shipping Orientation
Caution
Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided. It may also be used to alert against unsafe practices
Relative Humidity
Equipment Alert
Indicates a potentially hazardous situation which could result in equipment damage if not avoided.
100 F 38 C
23 F -5 C
Transportation & Storage Temperature Atmospheric pressure
Consult Manual
30
Duty Cycle 5 min
Maximum Patient Weight
Keep Dry
Type B, Applied Part
Maximum stacking height (Refer to “n” number on package.)
Type T Fuse
Transportation Orientation
Protective Earth Ground
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 3
Product Features Optional Touchpad Locations
Touch Pad Location The chair position touch pads allow you to position your patient from either side of the chair. Additional touch pads are available as options on delivery units and casework.
Power to the Chair When power is properly connected to the chair, the Power ON indicator illuminates. 1
2
3 4
Standard Touchpad Locations
Power ON
DA2549i
If the chair has no power...
A. Check / reset facility circuit breaker. B. Contact your dealer for service if necessary.
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 4
Collision Protection System To prevent damage to the chair or other equipment, the Midmark Ultra-series dental chairs are equipped with a Collision Protection System. If the safety bail cover of the chair contacts an object while the chair is moving down, the Chair Down function is disabled. To resume normal operation, remove the obstruction.
warning
Ensure patient is in a seated position while chair is moving.
Collision with safety bail cover stops Chair Down function. [All other functions work properly]
KA944300
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 5
Operation and Adjustments Chair Up / Down To move the chair UP or DOWN...
Back Up / Down
Press and hold the appropriate button on the foot control or touch pad.
Press and hold the appropriate button on the foot control or touch pad. Back UP
Chair UP
Chair UP
To move the back section UP or DOWN...
Back UP
Back DOWN
Chair DOWN
Back DOWN
Chair DOWN
KA944402i
KA944401i
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 6
Programming Chair Positions To program a chair position...
A) Move the chair to desired position. B) Press the Program button. (single “beep”) C) Press the desired Position button (1, 2, 3, or 4). (three “beeps”) Tip:
You must press the Position button within three seconds of pressing the Program button
To recall a programmed position...
Press desired Position button (1, 2, 3, or 4).
Position Buttons
Program
Position Buttons
Program
(this button is unmarked)
KA944403i
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 7
Rotating the Chair Caution
Be sure release handle is in the LOCKED position and chair is secure before beginning any procedure. 30° (LR/console models: 15°)
30° (LR/console models: 15°)
LOCKED
To rotate the chair...
A) Move release handle to UNLOCKED position. B) Move chair to desired position. C) Move release handle to LOCKED position. UNLOCKED KA943701i © 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 8
Adjusting the Headrest To adjust the headrest at pivot point(s)... A) Loosen clamp knob. B) Adjust headrest to desired position. C) Tighten clamp knob.
To adjust the headrest length... Slide headrest up / down as desired.
Note: Adjust friction if headrest will not stay in position.
KA943301
Adjustment Screws Jam Nuts
To adjust the headrest friction...
A) Remove back section upholstery. B) Loosen two jam nuts. C) Loosen / tighten two adjustment screws as necessary. D) Tighten two jam nuts (hold adjustment screws in place).
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 9
KA943002i
Cleaning Barriers
Cleaning Procedures
Single-use barriers and disposable items significantly reduce the need for chemical cleaners, thus prolonging the life of the equipment. Barrier material must be impervious to moisture / fluids.
Use cleaners that are appropriate for the situation, such as warm water and mild detergents, or a 10% solution of bleach with water. NOTE Every dental practice is different, and no single cleaner is the best choice for every facility. Listed below are some organizations to assist you in choosing the best cleaners available for your practice.
Examples of protective barriers: • Plastic covers (available from your dealer or equipment manufacturer) • Clear plastic wrap
• Organization for Safety & Asepsis Procedures:
• Plastic bags • Plastic sheets
http://www.osap.org
• Plastic tubing
• American Dental Association:
• Plastic-backed paper • Materials similar to those listed here
http://www.ada.org • Dept. of Health & Human Resources Centers for Disease Control & Prevention (CDC):
Cleaning Chair Upholstery Spot Cleaning
use mild soap and water solution
Difficult stains
use a mild solvent (ex. Fantastic®, 409®)
http://www.cdc.gov
Allow upholstery to air dry or use a hair dryer on the lowest setting!
Read all labels carefully!
Caution
Midmark assumes no responsibility or liability for any result, expressed or implied. These are suggested practices, based on the best information available at this time this is written.
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 10
Specifications
warning
Do not modify this equipment without authorization of the manufacturer.
Midmark Ultra-series Dental Chairs Patient Weight (max):
300 lbs (136 kg)
Electrical Rating:
115 V~ Models: 5A, 60 Hz 230 V~ Models: 3A, 50/60 Hz
Fuses: 115 VAC Models
warning
F1 & F2 (line input): 250V, T6.3AL, Time-delay F3 (transformer): 250V, T0.10AL, Time-delay
230 VAC Models
F1 & F2 (line input): 250V, T3.15AL, Time-delay F3 (transformer): 250V, T0.05AL, Time-delay
Duty Cycle (Motor Run Time):
Intermittent Operation (30 seconds ON / 5 minutes OFF)
Classifications:
Class I, Type B Applied Part Ordinary Equipment Intermittent Operation
Certifications:
ES/IEC/EN 60601-1, CAN/CSA-C22.2 No. 60101-1 (Safety Standards), EN/IEC 60601-1-2 (EMC Standards)
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
Chair- 11
Equipment is not suitable for use in the presence of a flammable anesthetic mixture with oxygen, air, or nitrous oxide. Clarification: Equipment is suitable for use in the presence of oxygen, air, or nitrous oxide.
Warranty Information SCOPE OF WARRANTY Midmark Corporation (“Midmark”) warrants to the original purchaser its Dental products and components (except for components not warranted under “Exclusions”) manufactured by Midmark to be free from defects in material and workmanship under normal use and service. Midmark’s obligation under this warranty is limited to the repair or replacement, at Midmark’s option, of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark prove to be defective. APPLICABLE WARRANTY PERIOD
(a) Five (5) years for all products and components (except for the shorter periods in (b and c), including plastic laminate top surfaces, door and drawer fronts, casters, and electrical components such as task lights and cords. (b) Three (3) years for task light ballast. (c) One year (1) for plastic laminate, solid surface countertops and accessories. EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following;
The applicable warranty period, measured from the date of delivery to the original user, shall be as follows: 1. DENTAL PRODUCTS are warranted against defect in material and workmanship for the period indicated below from the time of delivery: (a) Two (2) years for all products and components (except for the periods in b thru e). (b) “KINK-VALVE” module carries a ten (10) year warranty. (c) The original light bulb on a new light carries a one (1) year warranty. (d) Accessories not manufactured by Midmark are excluded. (e) Replacement parts and accessories carry a ninety (90) day warranty. 2. Oral Surgery PRODUCTS are warranted against defect in material and workmanship for a period of one (1) year from the time of delivery. 3. STERILIZERS PRODUCTS are warranted against defect in material and workmanship for a period of one (1) year from the time of delivery. 4. ULTRASONIC CLEANER PRODUCTS when used in accordance with manufacturer’s instructions and under normal use, are guaranteed for two (2) years after date of shipment. Within the period guaranteed, the manufacturer will repair or replace free of charge, at its sole discretion, all parts that are defective because of material or workmanship including costs for removing or installing parts. Repairs are made on a FOB repair depot basis. Manufacturer’s liability, whether based on warranty, negligence or other cause, arising out of and/or incidental to sale, use or operation of the transducer elements, or any part thereof, shall not in any case exceed the cost of repair or replacement of the defective equipment, and such repair or replacement shall be the exclusive remedy of the purchaser, and in no case shall manufacturer be responsible for any and/or all consequential or incidental damages including without limitation, and/or all consequential damages arising out of commercial losses. © 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
5. INTEGRA™ DENTAL CASEWORK AND ARTIZAN™ DENTAL FURNITURE PRODUCTS are warranted against defect in material and workmanship for the period indicated below from the time of delivery:
(1) repairs and replacements because of misuse, abuse, negligence, alteration, accident, freight damage, or tampering; (2) matching of color, grain, or texture except to commercially acceptable standards; (3) changes in color caused by natural or artificial light; (4) products which are not installed, used, and properly cleaned as required in the Midmark “Installation” and or “Installation/Operation” Manual for this applicable product; (5) products considered to be of a consumable nature; (6) accessories or parts not manufactured by Midmark; (7) specially manufactured products; (8) charges by anyone for adjustments, repairs, replacement parts installation, or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark. EXCLUSIVE REMEDY Midmark’s only obligation under this warranty is the repair or replacement of defective parts. Midmark shall not be liable for any direct, special indirect, incidental, exemplary or consequential damages or delay including, but not limited to, damages for loss of profits or loss of use. NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products.
THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.
Chair- 12