Barrier-Free™ Examination Table To purchase a printed copy of this manual, click on the "Place Order" button below.
Place Order
User’s Guide Style C
For models: 622 623
SF- 1882
003-1593-00 Rev L (11/11)
Go To Table Of Contents
Owner’s Product Identification (The information below is required when calling for service)
Model Number:
Serial Number:
Date of Purchase:
Name of Owner / Facility:
Name of Dealer:
Dealer’s Phone Number:
Midmark Authorized Service Company:
Serial / Model Number Label (exact location may vary)
MA731100i SF-1841
Table of Contents Important Information Safety Symbols ... 2 Transportation / Storage Conditions ... 2 Intended Use ... 3 Electrical Requirements ... 3 Electromagnetic Interference ... 3 Authorized CE Representative ... 3 Disposal of Equipment ... 3 Safety Instructions ... 4 Operation Table Up / Down Operation ... 5 Back Section Operation: 622 ... 6 623 ... 7 Home Function - 623 only ... 8 Exam Assistant™ Drawer System ... 9 Paper Roll & Tear Straps ... 10 Stirrups ... 11 Footrest & Treatment Pan ... 12 Drawer Heater (optional) ... 12 Pelvic Tilt (optional) ... 13 Duplex Receptacle (optional) ... 14 Maintenance Cleaning ... 15 Preventative Maintenance ... 15 Calling for Service ... 15 Specifications Weights, Dimensions, Electrical Specifications ... 16 Regulatory Compliance Chart: 622 / 623 ... 17 Range of Motion & Dimensions ... 18 Warranty Information Limited Warranty ... 20
1
Go To Table Of Contents
Important Information Safety Symbols Caution Indicates a potentially hazardous situation which could result in injury if not avoided.
Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage if not avoided.
Note Amplifies a procedure, practice, or condition. Consult User Guide for important information.
181 kg 400 lbs
ETL CLASSIFIED
Proper shipping orientation
Maximum stacking height (palletted units)
Fragile
Fuse rating specification
Type B, Applied Part
Dangerous voltage / shock hazard
Protective earth ground
Duty Cycle (motor run time): 30 seconds ON, 5 minutes OFF
Patient weight limit
CONFORMS TO: UL STD 60601-1 CERTIFIED TO: CAN/CSA STD C22.2 NO 601.1
42185
Keep dry
This product has been evaluated with respect to electrical shock, fire & mechanical hazards only, in accordance with UL60601-1 and CAN/CSA C22.2 NO. 601.1.
Transportation / Storage Conditions Ambient Temperature Range: ... +5°C to +38°C (+41°F to 100°F) Relative Humidity ... 10% to 90% (non-condensing) Atmospheric Pressure ... 500hPa to 1060hPa (0.49atm to 1.05atm)
2
Go To Table Of Contents
Intended Use This product is intended to be used as a chair / table to provide positioning and support of patients during general examinations and procedures conducted by qualified medical professionals.
Electrical Requirements Caution When using high frequency surgical devices or endocardial catheters: • Use non-conductive material to insulate patient from metal portions of the table. • Consult operating instructions for the device before using in conjunction with drawer or upholstery heater. Failure to comply may result in electric shock or burns to patient.
Electromagnetic Interference This Midmark table is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and this table: • Remove interfering device from room • Plug table into an isolated circuit • Increase seperation between table and interferring device • Contact Midmark if interference persists Electromagnetic Compliance Statements per EN60601-1-2 are available online:
(or click on button below)
Go to: www.documark.com (Use the FIND feature to locate: 077-0501-00)
EMC Statements
Authorized CE Representative Countries in the EEC should direct all questions, incidents, and complaints to Midmark’s Authorized CE representative listed below: Midmark Europe SAS 22, Rue De St. Denis 53500 Ernee, FRANCE Phone: 33-2-430-517-76 Fax: 33-2-430-569-10
Disposal of Equipment At the end of product life, the table, accessories, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods.
3
Go To Table Of Contents
Safety Instructions Caution Be sure that all personnel and equipment are clear of the table before activating any function. Failure to do so could result in personal injury. At the table’s lowest height [18 in. (45.7 cm)], the clearance between the bottom of the drawer and the floor is approximately 3.5 in. (9 cm). Make sure patient (esp. feet) and all objects are clear of this area before lowering table. If the table malfunctions, immediately release foot pedal, unplug the table power cord, and assist the patient from the table. If table continues to malfunction, call for service. Failure to comply with these instructions may result in injury to patient and/or damage to equipment.
Clearance: Approx. 3.5 in. (9 cm) MA611800i
4
Go To Table Of Contents
Operation Table Up / Down Operation Note The table automatically stops at its maximum and minimum height.
To move the table Up or Down... Press and hold the appropriate button.
622
623 UP
DOWN
MA658600i
DOWN
UP
Equipment Alert
UP DOWN
If the table’s weight limit is exceeded, you will hear a “beep” and the function will be disabled. If the problem occurs with a normal load, contact your service technician.
Max. 37 +0.5 in. (94 +1.3 cm)
Min. 18 +0.5 in. (45.7 +1.3 cm)
MA626000i
5
Go To Table Of Contents
Back Section Operation - 622
To position the back section... A. While holding the back section in place, squeeze the Back Release Handle (either side). B. Move the back section. C. Release handle to lock back section in position.
Range of Motion 0° (horizontal) to +80° +5°
Back Release Handle MA600301i
6
Go To Table Of Contents
Back Section Operation - 623 Note The back section automatically stops at the top and bottom of its travel.
To position the back section... Press and hold the appropriate button.
UP UP
DOWN
DOWN
MA658600i
Equipment Alert If the table’s weight limit is exceeded, you will hear a “beep” and the function will be disabled. If the problem occurs with a normal load, contact your service technician. Range of Motion 0° (horizontal) to +80° +5°
MA626200i
7
Go To Table Of Contents
Home Function - 623 only Note The Home Function automatically lowers the table to 20” (50.8 cm). Press the Stop button at anytime to stop movement.
To activate the Home Function... Press and release the Home button.
Home
MA658600i
Home
Stop
Stop
Max. 37 +0.5 in. (94 +1.3 cm)
Home Function Height 20 +0.5 in. (50.8 +1.3 cm)
MA626100i
8
Go To Table Of Contents
Exam Assistant™ Drawer System
C To use the drawer front as a shelf... Pull drawer front down to release the magnetic latch.
Equipment Alert The maximum weight the shelf will support is 10 lbs (4.5 kg).
Tabs
C
If drawer front folds past horizontal... Press two tabs and swing drawer front upward.
Equipment Alert
MA603101i
If drawer front folds past horizontal, do not operate table.
9
Go To Table Of Contents
Paper Roll & Tear Strap Note Up to four paper rolls (max.) may be stored under the back section. Paper Roll Size (maximum): 622 & 623 (-007 & -008)... 21 in. long x 3.5 in. diameter (53.3 cm x 8.9 cm) 623 (-009 & -010) ... 19.7 in. long x 4.7 in. diameter (50 cm x 12 cm)
To install the paper roll... Insert rod ends into sockets under head end of upholstery.
To install the paper tear strap... Attach strap to snaps on each side of table.
MA628701i
10
Go To Table Of Contents
Stirrups Caution Be sure the stirrups are locked in place before using. The stirrups will not support the patient’s entire weight.
To position the stirrups... A. Pull the stirrup out, then unfold. B. Lift the stirrup slightly, then move it left or right as desired. C. Release stirrup to lock in position.
A
B
C MA602500i
11
Go To Table Of Contents
Footrest & Treatment Pan Caution Do not use footrest to support patient’s entire weight.
To access the treatment pan... Lift footrest pad slightly, then slide pad back into table.
To extend footrest... Pull footrest out to desired position.
MA626400i
Drawer Heater (optional) Note The drawer heater switch illuminates when heater is ON. The drawer heater warms the contents of the drawer to approximately 98°F (37°C).
To turn the drawer heater ON / OFF... Press & release the drawer heater switch.
MA625702i
Drawer Heater Switch
12
Go To Table Of Contents
Pelvic Tilt (optional)
To elevate seat section... Lift seat until pelvic support drops into place.
Pelvic Support
To return seat section to flat position... A. Lift seat section slightly. B. Pivot pelvic support handle upward. C. Lower seat section.
MA718301i
13
Go To Table Of Contents
Duplex Receptacle (not available on 230 volt models) The duplex receptacle on the side of the table provides power for accessories used during medical procedures. There are two circuit breakers located under the seat section. If the receptacle’s maximum load is exceeded, the circuit breakers interrupt power to the receptacle.
Maximum Load: ... 115 VAC, 5 amps
To reset the circuit breaker... Push circuit breaker switch.
Circuit Breakers 5 A M P
Tripped (no power)
5 A M P
Reset (power)
MA603404i
14
Go To Table Of Contents
Maintenance Cleaning Clean upholstery with 5% bleach/water solution.
Equipment Alert The upholstery is resistant to most medicinal-type stains, but may be damaged by solvents and dyes. Immediately remove any fluids spilled on the upholstery. Clean the table weekly, wiping the painted metal and plastic surfaces with a clean, soft cloth, and mild cleaners. Periodic applications of common furniture wax will ease cleaning and maintain the finished luster of the table.
Preventive Maintenance Periodically inspect the following areas:
• • •
Power cord should be free of cuts or other visible damage. All fasteners should be present and tightened securely. All mechanical functions should operate properly.
Periodically lubricate the following areas to maintain quiet, smooth, operation: • Back hinge (use light machine oil) • Footrest slide (use household furniture wax) Have a qualified service technician inspect your table every six months.
Calling For Service Note Model / Serial Number information is required when calling for service. Contact your Midmark Dealer, or log onto www.midmark.com to locate your nearest service provider. To contact Midmark directly: 1-800-Midmark (1-800-643-6275) or 937-526-3662 8:00 am until 5:00 pm. Monday through Friday (EST) [excluding standard U.S. holidays]
15
Go To Table Of Contents
Specifications Weights, Dimensions, Electrical Specifications Patient Weight (Maximum) ... 400 lbs (181.4 kgs) Paper Roll (maximum size): ... (See Paper Roll & Tear Straps page) Range of Motion & Dimensions ... (See Range of Motion & Dimensions page) Weight of Table: [Weights listed are for 115V models. The 230V transformer adds 14.5 lbs (6.5 kg)]
622 / 623 w/upholstery ... 325 lb (147 kg) w/packaging & skid (no uph.) ... 375 lb (192.7 kg) Upholstery w/packaging (shipped seperately) ... 40 lbs (18.1 kg) Power Cord(s) [115V models have two cords]: ... 8 ft. (243.8 cm) long Electrical Requirements: ... [See Regulatory Compliance Charts] Foot / Hand Control Voltage: ... 14 VAC, SELV (Safety Extra Low Voltage) Duplex Receptacle (optional) maximum load: ... 115 VAC, 5A, 50/60 Hz Fuses: 622/623 (all): F1 & F2 (on main PC board) ... 10A, 250V, Type-T, 1/4" x 1 1/4" F3 (on main PC board) ... 5A, 250V, Type-T, 1/4" x 1 1/4" F4 (on main PC board) ... 187 mA, 250V, Type-T, 1/4" x 1 1/4" F5 (on main PC board) ... 4A, 250V, Type-T, 1/4" x 1 1/4" Models w/ drawer heater distribution board fuses (2) ... 800 mA, 250V, Type-T, 5 x 20mm Models w/ upholstery heater uph. heater PC board fuses (2) ... 1/2 A, 250V, Type-T, 1/4" x 1 1/4" 623 (-009 & -010): located next to IEC inlet (2) ... 4A, 250V, Type-T, 5 x 20 mm Duty Cycle: Actuator motor run time: ... Intermittent Operation [30 seconds ON / 5 minutes OFF] Receptacle / Drawer Heater / Uph. Heater: ... Continuous Operation
Classifications: ... Class 1, Type B Applied Part, Protection against ingress of fluids: ... IPX0 [Foot Control only: IPX1]
Equipment not suitable for use in the presence of a flammable anesthetic mixture with air, or with oxygen, or nitrous oxide.
16
V V
Midmark Power Back Table - Export w/ Pelvic Tilt
Midmark Power Back Table - Export w/ Pelvic Tilt, Drawer Heater, & Heated Upholstery
623-010
V
V
623-009
Midmark Power Back Table 623-008 w/ Receptacle, Pelvic Tilt Drawer Heater, & Heated Upholstery
623-007
Midmark Power Back Table w/ Receptacle
V
Midmark Manual Back Table 622-008 w/ Receptacle, Drawer Heater, Pelvic Tilt, & Heated Upholstery
622-007
V
Description
Serial Number Prefix
X
X
X
X
X
X
UL 60601-1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CAN/CSA EN IEC 22.2, 60601-1-2 60601-1 #601.1-M90 (EMC)
Complies To:
X
X
X
X
X
X
CE
230
230
115
115
115
115
VAC +/10%
4.25
3.75
13.5
12.5
11.5
10.5
Amps
50/60
50/60
50/60
50/60
50/60
50/60
Cycles (Hz)
Electrical Ratings:
All upholstery complies with California Bureau of Home Furnishing Technical Bulletin 117 Optional upholstery is available that complies with California Bureau of Home Furnishing Technical Bulletin 133.
Midmark Manual Back Table w/ Receptacle
Model
Fire Code Ratings:
Regulatory Compliance Chart - 622 / 623
Go To Table Of Contents
17
Go To Table Of Contents
Range of Motion & Dimensions
Max. 37 +0.5 in. (94 +1.3 cm) Min. 18 +0.5 in. (45.7 +1.3 cm)
Auto Return Height 20 +0.5 in. (50.8 +1.3 cm)
0° (horizontal) to +80° +5°
Pelvic Tilt (optional) Max: 7° +2° Min: 1.5°
MA8381i
18