BRM3 Brain Monitor In-Service Infant Preparation and BRM3 Technology
BRM3 Brain Monitor In-service Overview • HELP Screen • Set-up • Preparing the Patient
► Hydrogel Electrodes ► Low Impedance Electrodes
• Starting and Stopping a Recording • Entering Patient Information • Markers • Printing Options • Taking Snapshots • Managing Files ► Archiving a Session to USB ► Restoring Sessions from USB ► Deleting Files
• Cleaning the BRM3
Copyright 2008 •DOC-001709A
2
510K Clearance • Indications for use: • The BRM3 Brain Monitor is an electroencephalographic or EEG system; a device used to measure and record activity of the patient’s brain obtained by placing two or more electrodes on the head
► The BRM3 Brain Monitor is intended for use to monitor the state of the brain by acquisition of EEG signals, in clinical environments such as the intensive care unit, and for clinical research
► The BRM3 Brain Monitor is intended for use only with neonatal patients, defined as from birth to 28 days post-delivery, and corresponding to a post-conceptual age of 24 – 46 weeks
► The BRM3 Brain Monitor does not provide any diagnostic conclusion about the patient’s condition. Copyright 2008 •DOC-001709A
3
Help Topics
Copyright 2008 •DOC-001709A
4
BRM3 Brain Monitor Set-Up
Copyright 2008 •DOC-001709A
5
Sensor Adaptor Set
Copyright 2008
6
Hydrogel and Low Impedance Needle Electrodes
Copyright 2008
7
Preparing the Patient - Two EEG Channels
• 5 Electrodes
► 4 Active ► 1 Ground - (Green)
• Lead Placement:
► C3/P3 and C4/P4 placement ► Ground – back or chest
Copyright 2008 •DOC-001709A
8
Gather Supplies • Sensors
► Sensor Adaptor Set (with Positioning Aid included inside the pouch) ► Electrodes
• Hydrogel electrodes • Low impedance needle electrodes • Other – 1.5 mm compatible electrodes
• Skin Marker • Skin Prep
► NuPrep™, water, gauze, cotton swab, wrap hat (optional) - for hydrogel electrodes ► Antiseptic prep – for low impedance needle electrodes ► Tape or other securing adhesive – for low impedance needle electrodes
• Comb – if excessive hair is present Copyright 2008 •DOC-001709A
9
Applying Electrodes
• Mark
• Prep
• Place
• Connect
Copyright 2008 •DOC-001709A
10
Placing Electrodes – Hydrogel
C 3
P3
Copyright 2008 •DOC-001709A
11
Hydrogel Electrodes • PURPLE
• BLACK
► Back of
► Front
the head
of the
head
Copyright 2008
12
Preparing the Site - Ground Electrode
Copyright 2008 •DOC-001709A
14
Placing Electrodes – Low Impedance Needles
C 3
P3
Copyright 2008 •DOC-001709A
15
Preparing the Site - Low Impedance Needle Electrodes
Copyright 2008 •DOC-001709A
16
Preparing the Site - Ground Electrode
Copyright 2008 •DOC-001709A
17
Connecting the Sensor Adaptor Set to the Data Acquisition Unit (DAU)
Copyright 2008 •DOC-001709A
18
Main Menu – Starting a Recording
3
Copyright 2008 •DOC-001709A
19
Copyright 2008
20
Copyright 2008