ACQUIDATA Calibration Procedure Edition 1

Calibration Procedure

10 Pages

ACQUIDATA CALIBRATION PROCEDURE The calibration procedure for the Acquidata product family is very simple. No special calibration screen or recording phase needs to be selected. Simply open a new recording using the settings file as if recording a urodynamics study. Select the settings with which you wish to check and calibrate the transducers.  CALIBRATION CHECKING Preparing Transducers Connect and prepare the transducers you intend calibrating file as follows: A) External Pressure Transducers: Check that the electrical transducer cables are connected to the AcquiAmplifier. Connect a vesical pressure catheter to the male port and connect a stopcock to the female port of the external pressure transducer. Connect a 10ml syringe of water to the stopcock, turn the stopcock so as to allow flushing of the pressure transducer and flush out all air bubbles. Close the stopcock to the transducer arm and hold the fluid filled catheters distal end (which is open to ambient pressure) at the same height as the centre of the transducer sensing area. B) MTC device pressure transducer catheters: Check that the electrical transducer cables are correctly connected to the AcquiAmplifier. Ready a water filled burette (tube) to a depth of 50 to 80cm. After about five minutes (to allow warm up) immerse the catheter sensing end into the water (to allow wetting) and remove from the water immediately prior to starting the calibration procedure. C) Fill volume transducer: Check that the electrical transducer cables are correctly connected to the AcquiAmplifier. Ready the transducer on the pole and hang a validated (accurate) 500g or 1000g weight on the transducer hook. D) Void Flow: This is calculated by running the contents of an IV bag of saline from the bag when on the calibrated Fill volume transducer, directly into the primed and zero balanced flow receiving chambers funnel. Calibration Checking Start the data scrolling with the start button or by using the key F11. Zero/Balance the channels by using the controls appropriate for either the Minim or Petite/Median/Major models. Note - the Minim has only an ‘All Zero’ mode. The other models allow global (all) or individual channel (via screen menu) mode. Ensure that there is enough baseline available (5 to 10mm) to later use before applying the calibrating (flow, pressure or volume) source. As the re-calibration process is common to all channels only one channel example will be explained below. In that example the channel is urethral pressure which is an A) External Pressure transducer. • Lift the distal end of the fluid filled catheter from the datum point (where the zero balance was done) to a known height of approximately 70 to 100cm. • Hold the catheter steady at this known cmH2 O height and allow 10mm duration of the trace at this level. • Check whether the displayed pressure on the screen is accurate to within +/- 3% of the full scale range.  Prepared By:  Checked By: Author  Content Authority  Approved By:  CONTROLLED DOCUMENT QA Manager  Date Date Date Review is MANDATORY on or before 24 months from Date of Approval Hand-written amendments are NOT allowed. Each amendment requires a new edition.  Do NOT Copy. Contact QA Manager if copy required  NS02301-SETUP Edition  1  Copy  1  Page  1 of 10
File Type: PDF
File Size: 360 KB
File Name: NEOMEDIX Systems - ACQUIDATA Calibration Procedure Edition 1.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions