NSK

Ti-Max Handpiece External Coolant Straight Operation Manual

2 Pages

External Coolant Straight Handpiece Titanium Body  Ti-SG65L  OM-H0133E 001  CAUTION • When operating the handpiece always consider the safety of the patient. • This handpiece is designed for implant surgery. • Do not disassemble or alter the handpiece. • Check for vibration, noise and overheating outside the patient's oral cavity before use. If any abnormalities are found, stop using the handpiece immediately and contact authorized dealer. • Should the handpiece function abnormally, cease operation immediately and return the handpiece to an authorized dealer for repair. • Do not allow any impact on to the handpiece. Do not drop the handpiece. • Do not rotate the motor when the Bur Lock Ring is at OPEN position, or a bur is not mounted in the chuck and do not turn the Bur Lock Ring while the handpiece is rotating. It may cause the motor/handpiece disconnection or sudden heat generation. • Do not connect or disconnect the handpiece until the derive motor has completely stopped. • After each use, be sure to clean, lubricate and sterilize the handpiece. If blood is left on the handpiece, it can clot causing rust. • Perform periodical maintenance checks. • The user shall be responsible for operation, maintenance and operation.  1. Specifications Model Gear Ratio Allowable Max. Speed Bur Size Optics Weight  Ti-SG65L 1 : 1 Direct Drive 40,000 min-1 Handpiece Bur (ø2.35) Glass Rod Optic 66g  2. Connecting / Disconnecting the Handpiece (1) Connecting Align the Positioning Marks of the handpiece and the motor. Insert those straight until end of the motor insertion. (2) Disconnecting Hold the handpiece and the motor and pull those out straight.  Handpiece  Positioning Mark  Motor  Fig.1  3. Mounting and Removing Bur (1) Mounting Bur 1) Turn the Bur Lock Ring in the direction of mark “O” until it clicks. 2) Insert the Bur 3) Turn the Bur Lock Ring in the direction of mark “C” until it clicks. Make sure the Black Dots align. (See the picture below) (2) Removing Bur Turn the Bur Lock Ring in the direction of mark “O” until it clicks and remove the bur.  Open  Bur Lock Ring  Align the Black Dots  Close  Black Dots  Fig. 2  CAUTION for Bur Usage • Only use suitable burs. • Do not use bent, damaged or sub-standard burs. The Shank could bend or brake even within the recommended speed. • Always keep the bur shanks clean. Dirt or debris in a chuck could cause poor bur concentricity or low chuck retention force. • Follow the instructions of bur manufactures for recommended operating speed as bur breakage may occur if rotated at an excessive speed. • Always mount the bur even when the handpiece is not in use. • Before use always check that the bur is correctly seated and locked in place. • Make sure if the Black Dots of the Bur Lock Ring align after fixing the bur. Rotating the bur in an improper position may cause heat generation, which results in burns.
File Type: PDF
File Size: 653 KB
File Name: NSK - NAKANISHI - OM-H0133E - Ti-Max Handpiece External Coolant Straight Operation Manual - 2009-07.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions