O-Two Medical Technologies Inc

Pressure Regulators

01FC Series Medical Gas Flow Controllers Operating Instructions Rev 7 Feb 2020

Operating Instructions

2 Pages

WARRANTY: The O-Two Therapy Flow Controllers for Use with Medical Gases are manufactured from the finest quality materials. Each individual part is subject to strict quality control tests to ensure exceptionally high standards. The manufacturer warrants to the purchaser of the O-Two Flow Controller that its component parts are free from defects in material and workmanship for a period of five (5) years from the date of purchase. The manufacturer will replace and/  FLOW CONTROLLERS  FOR USE WITH MEDICAL GASES  or repair all parts of the Flow Controller at its option for five years from the date of purchase at no cost to the purchaser, upon the notification of the defects, in writing by the purchaser and confirmation of said defect by the manufacturer. All shipping costs shall be borne by the purchaser. The manufacturer shall be liable under this warranty only if the Flow Controller  REF  01FC  and its parts have been used and serviced in the normal manner described in the instruction manual. This warranty does not cover failure resulting from alterations, accidental damage, misuse or operation not in accordance with the instructions provided. Wear items are not covered hereunder. This warranty is null and void if unauthorized repairs are attempted or performed. There are no other expressed or implied warranties. This warranty gives no specific legal rights.  INTENDED USE: The O-Two Medical Technologies “Therapy Flow Controller” is intended for the delivery of adjustable therapy flow rates (medical oxygen or medical air) to a patient. DESCRIPTION: The O-Two “Therapy Flow Controller” is a therapy flow administration device which is capable of delivering a controllable continuous flow of medical gas (oxygen or air) within the specified range. Connected to medical gas supply system, O-Two “Therapy Flow Controller” can deliver the desired therapy flow by adjusting flow-selecting control.  SAFETY WARNINGS  1. It is imperative that the O-Two Therapy Flow Controller only be operated in accordance with the instructions as described in this manual by clinically trained and authorized personnel. Do not use the Flow Controller for driving any medical equipment. 2. Using oil, grease or other petroleum-based substances with oxygen and oxygen mixtures may cause fire or explosion. Never handle Flow Controllers with oily or greasy hands or gloves. Do not use or store oxygen equipment near excessive heat or open flame. 3. Make sure that the inlet fittings on flow controllers are properly mated for the gas intended. Never attempt to force an incompatible connection or change the connectors. Never interchange flow controllers, hoses, or other equipment with similar equipment intended for use with other gases. 4. Disconnect the flow controller from a pressure source and release all gas from the flow controller after each use. 5. Do not stand in front of a flow controller outlet when opening the pressure source in case foreign particles are present which could cause a hazardous malfunction of the flow controller. Never occlude the outlet to test for the presence of pressure. 6. The flow controller doesn’t indicate that a flow is occurring. 7. Setting the flow-selecting knob between adjacent settings may cause the output flow to cease!  SPECIFICATIONS:  8. Varying inlet pressure outside the specified operating inlet pressure has significant impact on the accuracy of output therapy flow rate!  GAS  Medical Oxygen, Medical Air  OPERATING INLET PRESSURE  50 to 55 PSI  9. Presence of outlet resistance may result in decrease of the flow rates delivered.  THERAPY FLOWRATE RANGE  0 – 6 l/min, 0 – 8 l/min, 0 – 15 l/min, 0 – 25 l/min  STORAGE TEMPERATURE  From -28°C to +60°C  10. Ambient temperature variations within the specified operating temperature range have no effect on the accuracy of flow rate.  OPERATING TEMPERATURE  From -18°C to +50°C  11. Oxygen therapy may be critical treatment. The application of oxygen therapy using this flow controller should be made in strict accordance with the prescription and instructions of a physician.  O-TWO MEDICAL TECHNOLOGIES INC.  12. Never disassemble a flow controller under pressure! Disassembly and assembly of flow controllers shall be performed only by O-Two authorized and trained personnel. Unauthorized disassembly will void the warranty. Lubricant, if used in the maintenance of the flow controller, shall be compatible with the intended medical gases. Use of lubricants not recommended by the manufacturer may cause fire or explosion.  45A Armthorpe Road, Brampton, Ontario, Canada L6T 5M4 Tel. (905) 792-6896 Fax (905) 799-1339 www.otwo.com  Rev. 7 Feb 2020
File Type: PDF
File Size: 419 KB
File Name: O-Two Medical Technologies Inc - 01FC Series Medical Gas Flow Controllers Operating Instructions Rev 7 Feb 2020 - 2020-02.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions