Instruction Manual
58 Pages
Preview
Page 1
Adventurer Pro Balances Instruction Manual
Compliance Compliance to the following standards is indicated by the corresponding mark on the product. Marking
Standard This product conforms to the EMC directive 2004/108/EC, the Low Voltage Directive 2006/95/EC and the Non-automatic Weighing Instruments Directive 90/384/EEC. The complete declaration of Conformity is available from Ohaus Corporation. AS/NZS4251.1, AS/NZS4252.1 CAN/CSA-C22.2 No. 1010.1-92; UL Std. No. 61010A-1
EC Emissions Note This device complies with EN55011/CISPR 11 Class B Group 1. Important notice for verified weighing instruments Weighing instruments verified at the place of manufacture bear one of the preceding marks on the packing label and the green ‘M’ (metrology) sticker on the descriptive plate. They may be put into service immediately. Weighing instruments to be verified in two stages have no green ‘M’ (metrology) on the descriptive plate and bear one of the preceding identification marks on the packing label. The second stage of the initial verification must be carried out by the approved service organization of the authorized representative within the EC or by the national weights and measures (W+M) authorities. The first stage of the initial verification has been carried out at the manufacturer’s work. It comprises all tests according to the adopted European standard EN45501:1992, paragraph 8.2.2. If national regulations limit the validity period of the verification, the user of the weighing instrument must strictly observe the re-verification period and inform the respective W+M authorities. Disposal In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. For disposal instructions in Europe, refer to www.ohaus.com/weee. Thank you for your contribution to environmental protection.
FCC Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Industry Canada Note This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
ISO 9001 Registration In 1994 Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (VQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard’s requirements. On May 15, 2003, Ohaus Corporation, USA, was re-registered to the ISO 9001:2000 standard.
Adventurer Pro
EN-1
TABLE OF CONTENTS 1. 1.1 1.2 1.3
INTRODUCTION ... EN-3 Description ... EN-3 Features ... EN-3 Safety Precautions ... EN-3
2. 2.1 2.2
INSTALLATION ... EN-4 Unpacking ... EN-4 Installing Components ... EN-4 2.2.1 Assembly of Models AV412, AV812, AV2101, AV2102, AV3102, AV4101, AV4102, AV8101 ... EN-4 2.2.2 Assembly of Models AV64, AV114, AV213, AV264, AV313, AV413, AV513 ... EN-5 2.2.3 Assembly of Model AV53 ... EN-8 2.2.4 Assembly of Models AV212 ... EN-9 Selecting the Location ... EN-9 Leveling the Balance ... EN-9 Connecting Power ... EN-10 2.5.1 AC Adapter ... EN-10 2.5.2 Battery Installation ... EN-10 2.5.3 Turning Power On and Off ... EN-10 Initial Calibration ... EN-10
2.3. 2.4 2.5
2.6
3. OPERATION ... EN-11 3.1 Overview of Controls & Display Functions ... EN-11 3.1.1 Models AV53, AV212, AV412, AV812, AV1502, AV2101, AV4101, AV8101 ... EN-11 3.1.2 Models AV64, AV64C, AV114, AV114C, AV212C, AV53C, AV213, AV213C, AV313C, AV264, AV264C, AV412C, AV413, AV413C, AV513C, AV812C, AV2101C, AV2102, AV2102C, AV3101C, AV3102, V4101C, AV4102, AV4102C, AV8101C ... EN-11 3.2 Button Control Functions ... EN-13 3.3 Using the Button Control Functions ... EN-14 3.3.1 Setting the Balance to Zero ... EN-14 3.3.2 Taring ... EN-14 3.3.3 Changing Units of Measure ... EN-14 3.3.4 Changing Application modes ... EN-14 3.3.5 Printing Data ... EN-14 3.4 MenuEN-16 3.4.1 Menu Structure ... EN-15 3.4.2 Menu Navigation ... EN-16 3.4.3 Changing Settings ... EN-16
EN-2 3.5
Adventurer Pro
TABLE OF CONTENTS (Cont.)
Application Modes ... EN-17 3.5.1 Weighing ... EN-17 3.5.2 Parts Counting ... EN-17 3.5.3 Percent Weighing ... EN-18 3.5.4 Check Weighing ... EN-19 3.5.5 Animal Weighing ... EN-20 3.5.6 Display Hold ... EN-21 3.5.7 Totalize ... EN-22 3.6 Additional Features ... EN-22 3.6.1 Weigh Below ... EN-22 3.6.2 Battery Operation ... EN-23 3.7 Balance Settings ... EN-24 3.7.1 Calibration ... EN-24 3.7.2 Calibration Masses ... EN-29 3.7.3 Setup ... EN-30 3.7.4 Readout ... EN-30 3.7.5 Mode ... EN-30 3.7.6 Unit ... EN-31 3.7.7 Print-1 and Print-2 ... EN-31 3.7.8 RS232-1 and RS232-2 ... EN-32 3.7.9 GLP Data ... EN-33 3.7.10 GLP Print ... EN-34 3.7.11 Reset ... EN-34 3.7.12 Lockout ... EN-35 3.7.13 End ... EN-35 3.8 Legal for Trade (LFT) ... EN-35 3.9 Sealing Access to the Balance Settings ... EN-36 3.10 Printing Data ... EN-36
4. MAINTENANCE ... EN-37 4.1 Calibration ... EN-37 4.2 Cleaning ... EN-37 4.3 Troubleshooting ... EN-37 4.4 Service Information ... EN-38 4.5 Parts ... EN-38 4.6 Accessories ... EN-39 5. TECHNICAL DATA ... EN-40 5.1 Drawings ... EN-41 5.2 Specifications ... EN-43 5.3 Capacity x Readability ... EN-46 5.4 Communication ... EN-49 5.4.1 Commands ... EN-49 5.4.2 Connections ... EN-50 Limited Warranty ... EN-51
Adventurer Pro
EN-3
1 INTRODUCTION This manual contains installation, operation and maintenance instructions for the Ohaus Adventurer Pro balances. Please read the manual completely before using the balance.
1.1 Description The Adventurer Pro balances are precision weighing instruments that will provide you with years of service if properly cared for. The Adventurer Pro balances are available in capacities from 51 grams to 8100 grams.
1.1.1 Model Name Designations Example: AV214CDR AV = Product family abbreviation Adventurer Pro 214 = 210g model with 0.0001g readability C = With internal calibration (INCAL) D = Dual range model R = 2nd interface installed (RS232) U = 2nd interface installed (USB)
1.2 Features The Adventurer Pro balances include many standard features. These include: • Battery* or AC Adapter operation (AC Adapter included) • Weighing, Parts Counting, Percent Weighing, Check Weighing, Animal Weighing Display Hold and Totalize application modes. • In-use cover • RS232 interface • Integral security bracket • Weigh below hook * Battery operation is only available on certain models. The Adventurer Pro also offers several optional features • Internal Calibration • USB interface • Second RS232 Interface
1.3 Safety Precautions Please follow these safety precautions: • Verify that the input voltage printed on the AC Adapter matches the local AC power supply. • Use the balance only in dry locations. • Do not operate the balance in hostile environments. • Do not drop loads on the platform. • Do not place the balance upside down, without first installing the cone cover. • Service should be performed only by authorized personnel.
3 page 3 to 8.pmd
3
7/20/2009, 11:45 AM
EN-4
Adventurer Pro
2 INSTALLATION 2.1 Unpacking Carefully remove your Adventurer Pro balance and each of its components from the package. Save the packaging to ensure safe storage and transport.
2.2 Installing Components Use the illustrations and instructions below to identify and assemble your Adventurer Pro model with its components. All components must be installed before using the balance.
2.2.1 Assembly of Models AV412, AV812, AV2101, AV2102, AV3102, AV4101, AV4102, AV8101 Note: Assembly instructions also apply to models with the suffix C, CR, CU, R or U. 1. Insert the Sub-platform on the Mounting Cone located in the center of the balance. Align the Sub-platform so that it is fully seated on the cone. 2. Place the Weighing Pan on the Sub-platform. 3. For applicable Adventurer Pro models, place the Wind Ring over the pins located on the perimeter of the balance.
Weighing Pan
Sub-platform Wind Ring (INCAL models)
Pin
3 page 3 to 8.pmd
Mounting Cone
4
7/20/2009, 11:45 AM
Adventurer Pro
EN-5
2.2.2 Assembly of Models AV64, AV114, AV213, AV264, AV313, AV413, AV513C, AV53C Note: Assembly instructions also apply to models with the suffix C, CR, CU, R or U. 1. Insert the Platform Assembly on the Mounting Cone in the center of the balance. 2. Carefully remove each of the five (5) glass Draft Shield sections from its packing. You will note that two (2) of these are plain, two (2) contain handles, and the other is set in a plastic frame. These sections or panels comprise the front and rear, side doors, and top (respectively) of the Draft Shield. The Draft Shield contains four (4) upright posts and two (2) cross-members which act as a framework for insertion of the panels. 3. Install the plain glass panels to form the front and rear of the Draft Shield. • Select a plain glass panel and insert the bottom edge of the glass in the recessed slot in front of the balance, as shown. • As you push the top edge of the glass panel toward the cross-member, reach inside the top of the framework and depress the small clip located under the cross-member. • Press the glass panel into the framework until you feel the glass slip into place. • Release the clip when the glass panel is fully inserted. • Repeat these steps to install the other plain glass panel on the opposite side of the framework. Clip Locations
Close-up of Clip Platform Assembly Glass Rear Panel
Mounting Cone
Recessed Slot Glass Front
3 page 3 to 8.pmd
5
7/20/2009, 11:45 AM
EN-6
Adventurer Pro
2.2.2 Assembly of Models AV64, AV114, AV213, AV264, AV313, AV413, AV513, AV53C (Cont.) 4. Install the glass doors in the sides of the Draft Shield framework. Note: The glass doors must be inserted in the Draft Shield framework before inserting the top door; likewise, you must remove the top door before you remove the side doors. • Hold and position each door so that the handle is near the front of the balance and the small notch on the bottom edge of the door is lined up with the tab that protrudes from the side of the balance housing (shown below). • Insert the top edge of the glass door into the recessed area under the top crossmember of the Draft Shield framework. • Slide the notch on the bottom edge over the tab and slip the door in place. 5. The door may now be opened by sliding it toward the back of the balance.
Left Door
Close-up of Tab
Right Door
Close-up of Notch
3 page 3 to 8.pmd
6
7/20/2009, 11:45 AM
Adventurer Pro
EN-7
2.2.2 Assembly of Models AV64, AV114, AV213, AV264, AV313, AV413, AV513C, AV53C (Cont.) 6. Install the top door panel. • Insert the top door in the Draft Shield by holding the door vertically over the top of the Draft Shield framework, as shown. • Position the back edge of the door so that it lines up with two small hinges located on the rear cross-member. • Gently press the door on to the hinges, until it snaps into place. • Tilt the door forward to close.
Top Door
Close-up view of recessed hinge on Draft Shield cross-member
3 page 3 to 8.pmd
7
7/20/2009, 11:45 AM
EN-8
Adventurer Pro
2.2.3 Assembly of Model AV53 Note: Assembly instructions also apply to models with the suffix R or U. 1. Insert the Sub-platform on the mounting cone in the center of the balance. 2. Place the Weighing Pan on the Sub-platform. 3. Attach the Draft Shield by inserting the round bottom edge in the circular recessed slot, as shown. 4. Place the metal cover on top of the Draft Shield.
Draft Shield Cover
Round Edge of Draft Shield Weighing Pan Sub-platform Mounting Cone Circular Recessed Slot
3 page 3 to 8.pmd
8
7/20/2009, 11:45 AM
Adventurer Pro
EN-9
2.2.4 Assembly of Models AV212 Note: Assembly instructions also apply to models with the suffix C, CR, CU, R or U. 1. Insert the Sub-platform on the Mounting Cone located in the center of the balance. 2. Place the Weighing Pan on the Sub-platform. 3. Place the Wind ring over the shoulder of the balance.
Weighing Pan Sub-platform Wind ring
Mounting Cone
2.3 Selecting the Location Locate the balance on a firm, steady surface. Avoid locations with excessive air current, vibrations, heat sources, or rapid temperature changes.
2.4 Leveling the Balance Before the balance is used, the feet should be adjusted so that the scale is level with the surface. This will enable accurate weighing. You will see a level bubble indicator in a small round window on the front of the balance. Level the balance by adjusting the leveling feet so the bubble is centered in the circle, as seen below.
Balance Level
Untitled-1
9
6/23/2009, 11:49 AM
EN-10
Adventurer Pro
2.5 Connecting Power 2.5.1 AC Adapter Connect the AC Adapter to the wall outlet. Connect the plug into the receptacle on the rear of the balance. For use with CSA Certified (or equivalent approved) power source, which must have a limited circuit output.
2.5.2 Battery Installation Some Adventurer Pro models operate with batteries. To install batteries, remove the pan and its components and install the cone cover to protect the load cell.
CAUTION: To protect the balance from damage while installing batteries, make sure the cone cover is in place. Remove the battery comparment cover from the bottom of the balance. Install 4 AA (LR6) batteries in the compartment, aligning the batteries according to the + and - symbols. With the balance in an upright position, remove the cone cover and re-install the pan and its components.
2.5.3 Turning Power On and Off Press the On/Zero button to turn power on. The balance performs a segment check. The balance then displays the last selected application mode.
To turn power off, press and hold the Off button until OFF is displayed, then release the button.
2.6 Initial Calibration When the balance is first installed, and when it is moved to another location, it must be calibrated to ensure accurate weighing results. Have the appropriate calibration masses available before beginning calibration. Refer to Section 3.7.1 for masses and calibration procedure.
IMPORTANT: Balance should acclimate to its new surroundings for at least 4 hours. Balance electronics should be warmed up for 1 hour prior to use.
Untitled-1
10
6/23/2009, 11:49 AM
Adventurer Pro
EN-11
3 OPERATION 3.1 Overview of Controls & Display Functions 3.1.1 Models AV53, AV212, AV412, AV812, AV2101, AV4101, AV8101
9 10
8 7
11
6 5
1 2 3 4
12
Top Views
Bottom View
14 Rear View
17 13 18
3.1.2 Models AV64, AV64C, AV114, AV114C, AV212C, AV53C, AV213, AV213C, AV313, AV313C, AV264, AV264C, AV412C, AV413, AV413C, AV513C, AV812C, AV2101C, AV2102, AV2102C, AV3101C, AV3102, AV4101C, AV4102, AV4102C, AV8101C
8 7
15
10 16 9
6 5
1 2 3 4
12
Top Views
Bottom View 16
17 14
18 13 Rear View
Untitled-1
11
6/23/2009, 11:49 AM
EN-12
Adventurer Pro
3.1 Overview of Controls and Display Functions (Cont.) 19
20
21
33 32 31 22 23
30 29
28 27 26
25
24
Digital Display Window TABLE 3.1-1 ADVENTURER PRO CONTROLS AND DISPLAY FUNCTIONS.
Untitled-1
No. Description 1 On / Zero / Off / Yes Button 2 Print Unit / No Button 3 Level Bubble 4 Function Mode / Back button 5 Tare Menu-Cal / Exit Button 6 Display 7 Pan 8 Type label on side of housing
No. Description 18 Lock Switch 19 Primary (7 segment) display 20 Brackets 21 Units of Measurement 22 Memory Indicator 23 Battery Strength Indicator 24 Pieces Indicator 25 Secondary (14 Segment) Display
9 Data label 10 Weigh Below Opening 11 Battery Compartment 12 Leveling feet 13 COM 1 Connector 14 COM 2 Connector (AV...R and AV...U Models only) 15 Wind Ring 16 Draft Shield 17 Power Connector
26 Gross Indicator 27 Brutto Indicator 28 Tare Indicator 29 Preset Tare Indicator 30 Net Indicator 31 Stability Indicator
12
32 Negative Indicator 33 Center of Zero Indicator
6/23/2009, 11:49 AM
Adventurer Pro
EN-13
3.2 Button Control Functions Four multifunction buttons are used to to operate the balance and navigate the menus. The function of each button is shown below. Press and Release Press and Hold
Yes
Primary Function
No
Back
Menu Function
Exit
Print On/Zero • If balance is off, • Sends current turns balance on. display value to the serial interface. • If balance is on,
Tare Function • Performs tare • Operation is dependent on the operation. application mode.
sets zero. Secondary Function
Menu Function
5 page 13 to 19.pmd
Unit Off • Change • Turns balance off. weighing unit.
Mode • Change application mode.
Menu-Cal • Enter the User menu. Calibration is the first sub-menu.
Back No Yes • Reverts back to • Accepts the • Rejects the previous menu current (blinking) current setting setting on the (blinking) on the item. display. • Decrements a display. value being • Increments a entered. value being entered.
13
Exit • Immediately exits menu mode. • Aborts a calibration in progress.
6/23/2009, 1:38 PM
EN-14
Adventurer Pro
3.3 Using the Button Control Functions 3.3.1 Setting the Balance to Zero Remove the load from the pan and press the Zero button to set the display to zero. When the weighing pan or platform is empty, The Center of Zero indicator turns on when the measurement is within + 1/4 d of the zero setting.
3.3.2 Taring Taring refers to the action of allowing for the weight of a container so that only the weight of objects held in the container (net weight) is displayed. To Tare Place the empty container on the pan and press the Tare button. Add material to the container. The net weight of the material is displayed. To clear the Tare value, remove the container from the pan and press the Tare button. Auto Tare Auto Tare automatically compensates for container weight so the balance displays net weight. Auto Tare must be set ON in the Setup sub-menu (See Section 3.7.2 Setup Sub-menu). The secondary display shows PLACE CONTAINER (blinking). When the container is placed on the pan, it is automatically tared and Net weight is displayed. The Tare value is automatically cleared when the container is removed from the pan. Preset Tare Use the xT command in the command table to enter a preset tare value through a computer. To clear the Tare value, enter a value of 0.0. See Section 5.4.1.
3.3.3 Changing Units of Measure The Adventurer Pro can be configured to measure in a variety of units, including custom units. The Unit Sub-menu is used to enable or disable a specific unit. To select a unit of measure: Press and hold the Unit button, then release it when the desired unit is displayed. Note: If the desired unit is not displayed, it must be turned on in the Unit menu (See Section 3.7.5).
3.3.4 Changing Application Modes The Adventurer Pro can be configured to operate in various application modes. The Mode Submenu is used to enable or disable a specific application mode. Press and hold the Mode button and release it when the desired mode is shown on the secondary display. Note: If the desired mode is not displayed, it must be turned on in the Mode menu. See Section 3.7.4.
3.3.5 Printing Data Press the Print button to send the displayed value to the COM port (See Section 3.10). Note: The port must have Auto Print set to OFF.
5 page 13 to 19.pmd
14
6/23/2009, 1:38 PM
Adventurer Pro
EN-15
3.4 MENU 3.4.1 Menu Structure The Adventurer Pro balance menu structure is illustrated below. CALIBRATION (3.7.1) Internal Calibration (InCal) Span Linearity Calibration test (CalTest) Calibration Adjust (Cal Adj) End Cal
PRINT-1 (3.7.7) Output When Stable GLP Tare Auto Print Content Num Only Header, Gross, Net, Tare, Ref, Result, GLP Layout Line Format 4LF Form Feed List End Print-1
PRINT-2 (Optional) Output When Stable GLP Tare Auto Print Content Num Only Header, Gross, Net, Tare, Ref, Result, GLP Layout Line Format 4LF Form Feed List End Print-2 RESET (3.7.11) Setup Readout Mode Unit Print-1 Print-2 RS232-1 RS232-2 GLP Data GLP Print Lockout Global End Reset
5 page 13 to 19.pmd
SETUP (3.7.3) Legal Trade Auto Tare Auto Off Back Light * End Setup
UNIT (3.7.6) mg g kg oz lb ct dwt oz t GN N t HK t SC
READOUT (3.7.4) Auto Zero Filter Gross Ind. End Read
t TW m Tical Baht Meshgal Tola Custom End Unit
RS232-1 (3.7.8) Baud Parity Handshake End RS1 GLP PRINT (3.7.10) Time Balance ID User ID Project ID Difference Name End GLP Prt LOCKOUT (3.7.12) Cal Setup Readout Mode Unit Print-1 Print-2 RS232-1 RS232-2 GLP Data GLP Print Reset Lock Set End Lockout
15
MODE (3.7.5) Weigh Count Percent Check Weigh Animal
Display Hold Totalize End Mode
RS232-2 (Optional) Baud Parity Handshake End RS2
GLP DATA (3.7.9) User ID Proj ID Time Date End GLP Data
END (3.7.13)
* Only included on models with battery operation.
6/23/2009, 1:38 PM
EN-16
Adventurer Pro
3.4.2 Menu Navigation The Adventurer Pro menu structure consists of three levels. The top level is the main menu which consists of a number of sub-menus. Enter
TOP LEVEL
CALIBRATION END
SETUP
LOCKOUT
READOUT
RESET
SECOND LEVEL
MODE
GLP PRINT
UNIT
PRINT-1
PRINT-2
GLP DATA
RS232-2
RS232-1
Typical Sub-menu
The second level of the menu structure is the sub-menu level. Each sub-menu is a loop that consists of a number of menu items.
END RS232
POWER
HANDSHAKE
BAUD
Typical Menu Item
PARITY
BOTTOM LEVEL The bottom level of the menu structure is the menu item level. Each menu item level consists of two or more settings
3.4.3
Typical Setting
8 NOP
7 EVEN
7 NOP
7 ODD
Changing Settings
To change a menu setting, perform the following steps: ENTER THE MENU Press and hold the Menu button until MENU appears on the primary (7-Segment) display. Release the button and the first sub-menu appears on the secondary (14-Segment) display (blinking). Note: When the secondary display is blinking, press Yes to accept. Press No or Back or view another selection. SELECT THE SUB-MENU Press the No button to select the next sub-menu or the Back button to select the previous sub-menu in the loop. Press the Yes button to select the sub-menu that appears on the secondary display (blinking). The sub-menu name now appears on the primary display and the first menu item in the sub-menu now appears on the secondary display (blinking). SELECT THE MENU ITEM Press the No button to select the next setting or the Back button to select the previous setting in the loop. Press the Yes button to select and save the setting on the secondary display (blinking) as the new menu item setting. EXIT THE MENU Press the Exit button at any time to quickly exit the menu or select END sub-menu and press the Yes button.
5 page 13 to 19.pmd
16
6/23/2009, 1:39 PM
Adventurer Pro
EN-17
3.5 Application Modes The Adventurer Pro balance incorporates Weighing, Parts Counting, Percent Weighing, Check Weighing, Animal Weighing, Display Hold and Totalize application modes. The default setting has the weighing mode turned on and all other application modes turned off. Note: Before using any application modes, they must be turned on in the Mode menu (See Section 3.3.4).
3.5.1 Weighing Use this mode to determine the weight of items in the selected unit of measure. The Adventurer Pro is shipped with grams enabled. Before using other units of measure, these units must be turned on in the Unit menu ( See Section 3.7.5 ). Weigh Press and hold Mode until the display shows WEIGH, then release the button. Press Zero to zero the balance. Place objects to be weighed on the pan to display the weight. The example displays a 200 gram weight.
3.5.2 Parts Counting Use the Parts Counting Mode to count samples of uniform weight. Press and hold Mode until Count is displayed, then release the button. Establish an Average Piece Weight (APW). Each time a new type of part is counted, the nominal weight of one piece (Average Piece Weight) must be established using a small quantity of pieces. This APW is stored until replaced by another APW. If an APW has already been established, Count is displayed with Clear APW? blinking. Press No to use the previously saved APW. Otherwise, press Yes to establish a new APW.
(Clear APW? blinking)
The current weight (0.00) is shown on the primary display and the default sample size (PLACE 10) is shown on the secondary display. To change the sample size, press and hold the No button to increment the sample size through the range of 1 to 100. Release the button when the desired sample size appears on the secondary display.
5 page 13 to 19.pmd
17
6/23/2009, 1:39 PM