OLYMPUS
MAJ-2301 Foot Switch Instructions
Instructions
76 Pages
Preview
Page 1
INSTRUCTIONS
FOOT SWITCH
Labels and Symbols
1
Important Information - Please Read Before Use
4
Summary of Equipment Functions
10
Chapter 1
Checking the Package Contents
11
Chapter 2
Nomenclature and Functions
13
Chapter 3
Installation and Connection
19
Chapter 4
Inspection
37
Chapter 5
Operation
45
Chapter 6
Reprocessing, Storage, Disposal, and Transportation
51
Chapter 7
Troubleshooting
53
MAJ-2301
Appendix
59
Contents
Contents Labels and Symbols ... 1 Important Information - Please Read Before Use ... 4 Intended use / Intended purpose ... 4 Patient selection criteria ... 4 Contraindications ... 4 Clinical Benefit ... 4 Instruction manual ... 4 User qualifications ... 5 Instrument compatibility ... 5 Prohibition of improper repair and modification ... 5 Signal words ... 6 Precautions ... 6 EMC ... 9
Summary of Equipment Functions ... 10
Chapter 1 Checking the Package Contents ... 11 1.1
Checking the package contents ... 11
Chapter 2 Nomenclature and Functions ... 13 2.1
Symbols and descriptions ... 13
2.2
Foot switch ... 14
2.3
Wireless unit ... 16
2.4
Foot switch hanger ... 16
2.5
Foot switch cable ... 17
2.6
Pairing stickers ... 17
Chapter 3 Installation and Connection ... 19 3.1
Precautions for installation and connection ... 19
3.2
Installation procedure workflow ... 20
3.3
Connection of wireless unit ... 21
3.4
Connection of foot switch hanger ... 24
3.5
Insertion of batteries into the foot switch ... 26
3.6
Pairing ... 31
3.7
Assign the functions of the switches ... 35
3.8
Storage of foot switch ... 36
MAJ-2301 INSTRUCTION MANUAL
i
Contents
Chapter 4 Inspection ... 37 4.1
Precautions of workflow ... 37
4.2
Inspection workflow ... 38
4.3
Inspection of remaining battery power (for wireless control) ... 38
4.4
Inspection of foot switch cable (for wired control) ... 41
4.5
Inspection of foot switch operation ... 43
Chapter 5 Operation ... 45 5.1
Operating precautions ... 45
5.2
Wireless control of foot switch ... 46
5.3
Wired control of foot switch ... 48
Chapter 6 Reprocessing, Storage, Disposal, and Transportation ... 51 6.1
Reprocessing, storage, disposal, and transportation ... 51
Chapter 7 Troubleshooting ... 53 7.1
Troubleshooting ... 53
7.2
Troubleshooting guide ... 54
7.3
Returning this instrument for repair ... 57
Appendix ... 59 Combination equipment ... 59 System chart ... 59
Specifications ... 61 Environments ... 61 Specifications ... 61
EMC information ... 63 Cautions on 2.4 GHz band radio wave equipment ... 68
ii
MAJ-2301 INSTRUCTION MANUAL
Labels and Symbols
Labels and Symbols Safety-related labels and symbols are attached on the locations shown below. If labels or symbols are missing or illegible, contact Olympus.
Foot switch
Battery compartment
Product plate
Product plate details
CE marking
Ukraine Radio Law Certification mark Crossed-out wheeled bin’ symbol Non-ionizing radiation marking Ingress protection rating Product plate
Inside of battery compartment
Battery insertion orientation indication The applicable battery type and the orientation for inserting the batteries are indicated.
MAJ-2301 INSTRUCTION MANUAL
The product name, power rating, non-ionizing radiation marking, and Ingress protection rating are indicated.
Rechargeable battery inhibition indication This marking inhibits the use of rechargeable batteries.
1
Labels and Symbols
Wireless unit
Wireless unit
Serial number plate Manufacturing date Product plate Date of manufacture
Product plate details
CE marking
Ukraine Radio Law Certification mark
Non-ionizing radiation marking Product plate
Crossed-out wheeled bin’ symbol
2
MAJ-2301 INSTRUCTION MANUAL
The product name, manufacturer name, power rating, and non-ionizing radiation marking are indicated.
Labels and Symbols
Back cover of this instruction manual Symbol
Description
Symbol
Description
Manufacturer
Authorized representative in the European Community
Translation
Importer (into European Union)
Package Symbol
Description Date of manufacture
95% 10%
Symbol 70C –20C
1060hPa
Humidity limit
Description Temperature limit
Atmosphere limit
700hPa
Unique device identifier
Catalogue number
Serial number
MAJ-2301 INSTRUCTION MANUAL
3
Important Information - Please Read Before Use
Important Information - Please Read Before Use
Intended use / Intended purpose This instrument has been designed to be used with Olympus Surgical Microscope for use in controlling it.
Patient selection criteria None known.
Contraindications None known.
Clinical Benefit Supports to achieve the clinical benefit of OME-V200 by providing wireless or wired operation function.
Instruction manual This instruction manual contains essential information on using this instrument safely and effectively. Before use, thoroughly review this manual and the manuals for the related equipment and use the equipment as instructed. Keep this and all related instruction manuals in a safe, accessible location. If you have any questions about any information in this manual, contact Olympus.
Terms used in this manual Surgical microscope (OME-V200) The surgical microscope designated by Olympus to be used in combination with this instrument.
4
MAJ-2301 INSTRUCTION MANUAL
Important Information - Please Read Before Use
Pairing Action of giving one-to-one correspondence between the wireless unit connected to the surgical microscope and the foot switch for holding wireless communication between them.
View field movement Function that moves the positioning of observation using the foot switch.
User qualifications The operator of this instrument must be a physician or medical personnel under the supervision of a physician and must be qualified to operate and perform safely in clinical procedures of microsurgery using surgical microscope. This manual, therefore, does not explain or discuss the details of microsurgery using surgical microscope. For details of microsurgery using a surgical microscope, the physician and operator are requested to judge from their viewpoints as specialists.
Instrument compatibility This instrument should be used in combination with the ancillary equipment shown in “ System chart” on page 59. Using incompatible equipment can result in patient or operator injury and/or equipment damage as well as malfunction. This instrument complies with EMC standard for medical electrical equipment edition 4 (IEC 60601-1-2: 2014).
Prohibition of improper repair and modification Never allow a person other than Olympus-qualified personnel to disassemble or modify the instrument, as this may result in injury of the patient or operator as well as damage to the equipment. Olympus will not assume any liability for human accident or equipment damage occurred due to repair by a person other than Olympus-qualified personnel.
MAJ-2301 INSTRUCTION MANUAL
5
Important Information - Please Read Before Use
Signal words The following signal words are used throughout this manual:
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices or potential equipment damage.
NOTE
Indicates additional helpful information.
Precautions Follow the warnings and cautions given below when handling this instrument. This information is to be supplemented by the warnings and cautions given in each chapter.
WARNING • Strictly observe the following precautions. Failure to do so may place the patient and medical personnel in danger of an electric shock. Do not souse or spill a liquid such as water over the wireless unit. If a liquid is spilt on it, immediately wipe it. Should a liquid penetrate the wireless unit, immediately stop using it and contact Olympus. Do not prepare, inspect, or use the foot switch with wet hands. Should a liquid enter the foot switch during the battery replacement, for example, immediately remove the batteries to prevent a fire or electric shock hazard. Once a liquid has entered the foot switch, do not use it because the equipment may have been damaged. • Never install and operate the foot switch in locations where: The concentration of oxygen is high; Oxidizing agents (such as nitrous oxide (N2O)) are present in the atmosphere; Flammable gases are present in the atmosphere; Flammable liquids are near. Otherwise, explosion or a fire may result because the foot switch is not explosion-proof. • Do not use for purposes other than those described in “ Intended use / Intended purpose” on page 4, as this may result in injury of the patient or operator as well as damage to the equipment.
6
MAJ-2301 INSTRUCTION MANUAL
Important Information - Please Read Before Use
WARNING • This instrument should be used under the conditions specified in “ Environments” on page 61. Otherwise, imperilment of safety or failure of equipment may result as well as malfunction.
CAUTION • Since this instrument has a wireless function, it may affect peripherals to be used at the same time. • Handle batteries by strictly observing the following. Incorrect use of batteries may cause fluid leak, heat generation, which would lead to equipment damage. Use batteries specified for this instrument. Do not use rechargeable batteries. Insert batteries by observing the (+) and (–) polarity. Use only batteries of the same brand. Do not use a battery with a broken coating. Do not use a battery deformed by dropping or other impact. Do not use a battery if any irregularity, including fluid leak, discoloration, and deformation, is observed. • Do not use this instrument in any place where it may be subject to strong electromagnetic radiation (for example, in the vicinity of a microwave therapeutic equipment, MRI, wireless set, short-wave therapeutic equipment, cellular/portable phone, etc.). This may impair the performance of this instrument. • Do not use this instrument in any place with strong magnetic force, or bring magnetized equipment or magnets closer. This may impair the performance of this instrument. • Do not apply excessive force to a switch of this instrument or press it with a sharp or hard object. Otherwise, the switch damage may result. • Connect various connectors in a dry state without contamination of electrical contacts. Also, do not touch the electrical contacts inside the connector directly. If the electrical contacts are dirty or used under wet conditions, the equipment may cause malfunction. • Do not apply excessive force or strong impact to this instrument, ancillary equipment, and cables. Otherwise, equipment damage or failure may result. • Remove batteries when they are exhausted or not to be used for a long period. If batteries are left inside the instrument, over-discharge may cause fluid leak, which may eventually lead to a failure of this instrument. • Remove dust and dirt from batteries before use. If the (+) or (–) pole is dirty or dusty, a contact failure may result. MAJ-2301 INSTRUCTION MANUAL
7
Important Information - Please Read Before Use
NOTE • Startup display icons are displayed on four corners of the observation monitor screen for ten to twenty seconds after the power is turned ON on the surgical microscope. Afterwards the icons will disappear. These icons are displayed until the setup of the surgical microscope has completed and does not mean malfunction.
Figure 1 • In case any serious incident happens to user or patient while operating the device,that incident should be reported to Olympus and the competent authority of the respective member state or country.
8
MAJ-2301 INSTRUCTION MANUAL
Important Information - Please Read Before Use
EMC • For safety, always use this instrument in combination with equipment compliant to the EMC standard. Otherwise, interference from or to other equipment may result. • The foot switch and wireless unit radiate RF energy to achieve their intended use (control of the surgical microscope). This means that they could produce electromagnetic interferences when they are placed in the proximity of equipment carrying the symbol marking below or mobile and portable RF communications equipment such as a cellphone. If an electromagnetic interference occurs, a relief measure such as displacement of interfered equipment will be required.
• The foot switch and wireless unit incorporate the radio communication function as shown in the following table. Consequently, they may be affected by electromagnetic interference from nearby equipment that uses the same frequency band as them. Before using them, make sure that there is no risk of electromagnetic interference from nearby equipment. Frequency band with potential risk of extraneous interference
2400 – 2483.5 MHz
Modulation method
Primary modulation: FSK Secondary modulation: FHSS
Antenna power
1.0 mW
Table 1
MAJ-2301 INSTRUCTION MANUAL
9
Summary of Equipment Functions
Summary of Equipment Functions This instrument is designed to be connected to the Olympus-designated surgical microscope. By pairing between the foot switch and wireless unit, the control signals of the surgical microscope can be transmitted with either wireless or wired connection. The function incorporated in this instrument is outlined below. Note that only one foot switch can be pairing with a wireless unit.
Pairing of foot switch and wireless unit Pairing of the foot switch and wireless unit enables wireless communication between them. Pairing can be set using the foot switch cable provided with this instrument. Wireless control of the functions of the surgical microscope is possible by controlling the foot switch. Refer to Section 3.6, “Pairing”.
Wired connection of foot switch In case the wireless signal is weak or the batteries are exhausted, the foot switch can be connected directly to the Olympus-designated surgical microscope using the provided foot switch cable. When the foot switch is connected through the foot switch cable, the functions of the surgical microscope can be controlled from the foot switch even when it contains no batteries in it. Refer to Section 5.3, “Wired control of foot switch”.
NOTE • The foot switch cannot control the microscope functions unless the provided wireless unit is connected to the microscope. Be sure to connect the wireless unit to the surgical microscope even before the wired control operation. • Wireless communication is not performed when wired connection.
10
MAJ-2301 INSTRUCTION MANUAL
1.1 Checking the package contents
Chapter 1
1.1
Checking the Package Contents
Checking the package contents
Match all items in the package, such as the foot switch, wireless unit, and accessories, with the components shown below. Inspect each item for damage. If the instrument is damaged, a component is missing, or you have any questions, do not use the instrument; immediately contact Olympus.
Foot switch and Wireless unit
Foot switch (MAJ-2301)
Wireless unit
Accessories
Foot switch hanger
Foot switch cable
Pairing stickers (No.1 – No.10)
Retaining screws (M4 × 5 mm) (× 4)
Retaining screws (M4 × 12 mm) (× 2)
Allen screwdriver (3 mm width across flats)
MAJ-2301 INSTRUCTION MANUAL
11
Ch.1
1.1 Checking the package contents
Instruction manual (This book)
EU DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY for Ukraine Radio Law
NOTE
Ch.1
This instrument does not come with batteries. Before use, prepare three “C”-size 1.5 V alkaline batteries separately.
12
MAJ-2301 INSTRUCTION MANUAL
2.1 Symbols and descriptions
Chapter 2
Nomenclature and Functions
This chapter is intended to explain the names and functions of the parts of the foot switch.
2.1
Symbols and descriptions
Foot switch Symbol
Ch.2 Description
Symbol
Description
Communication status marking
Battery power marking
Battery insertion orientation indication
Rechargeable battery inhibition indication
Foot switch 1
Foot switch 2
Foot switch 3
Foot switch 4
Foot switch 5
Foot switch 6
Medical device
Model number
Wireless unit Symbol
Description Foot switch marking
MAJ-2301 INSTRUCTION MANUAL
Symbol
Description Serial number
13
2.2 Foot switch
2.2
Foot switch
Upper surface 1
2
3
4
5
6 (6)
6 (5)
Ch.2 6 (3) 6 (4)
No.
7 (C)
7 (D)
7 (A)
7 (B)
6 (1)
6 (2)
Name
Description
1
Handle
To be held when carrying the foot switch. It can also be hooked on the foot switch hanger when storing the foot switch.
2
Pairing indicator
Indicates pairing with the combined wireless unit. Refer to Section 3.6, “Pairing”.
3
Joystick
Used to control the movement by the joystick on the foot switch of the surgical microscope.
4
Communication status indicator
The green LED lights when the communication status is good and flashes when it deteriorates. Refer to Section 5.2, “Wireless control of foot switch”.
5
Battery power indicator The amber LED lights or flashes according to the remaining battery power level. Refer to Section 3.5, “Insertion of batteries into the foot switch”.
6
Foot switches 1 to 6
The functions of the surgical microscope can be assigned to these switches. The function assignment is performed from the surgical microscope.
7
Foot switches A to D
Used to control the focusing and zooming functions of the surgical microscope. The functions of the four switches are assigned from the surgical microscope.
NOTE For the function assignment of the switches, refer to the instruction manual for the surgical microscope.
14
MAJ-2301 INSTRUCTION MANUAL
2.2 Foot switch
Rear and front surface 4 1 2
5
8
6 View when battery compartment cover is opened
3
7
7 Rear surface
Terminal surface
Ch.2
Close-up view of connection terminal
No.
Name
Description
1
Battery compartment cover
Opened or closed for inserting or removing batteries.
2
Finger hook
Insert your fingertip for opening the battery compartment cover.
3
Locks
Used to lock or unlock the battery compartment cover.
4
Battery compartment
Insert three “C”-size 1.5 V alkaline batteries.
5
Packing
Prevents water penetration inside the battery compartment.
6
Ribbon
To be pulled for removing batteries from the foot switch.
7
Connection terminal
Connect the FOOTSWITCH connector (on the side marked “FOOTSWITCH”) of the foot switch cable.
8
Terminal cover
Lid for protecting the connection terminal. To be opened when connecting the foot switch cable to the terminal.
MAJ-2301 INSTRUCTION MANUAL
15
2.3 Wireless unit
2.3
Wireless unit 1 2
2 3
Ch.2 No.
Name
Description
1
Connection terminal
Means of electrical connection to the surgical microscope.
2
Attaching holes
Used to attach the wireless unit to the surgical microscope using the provided retaining screws (M4 × 5 mm).
3
Pairing sticker attaching part
Attach the pairing sticker.
2.4
Foot switch hanger 1
2 4
3
No.
Name
Description
1
Attaching section
Used when attaching to the movement handle of the surgical microscope.
2
Attaching holes
Used to attach the foot switch hanger to the surgical microscope using the provided retaining screws (M4 × 12 mm).
3
Hook
Used to hook the foot switch.
4
Cable hook
Used to hook the cable when storing it.
16
MAJ-2301 INSTRUCTION MANUAL
2.5 Foot switch cable
2.5
Foot switch cable 2
1
3
4
5
6
7
No.
Name
1
FOOTSWITCH connector
Connect this connector to the connector on the foot switch when using it with wired connection.
2
Index
Connect the cable to the terminal on the foot switch so that this marking is visible on the top.
3
FOOTSWITCH marking
Indicates that the FOOTSWITCH connector is to be connected to the foot switch on this side.
4
MICROSCOPE marking
Indicates that the MICROSCOPE connector is to be connected to the surgical microscope on this side.
5
Index
Connect the cable to the footswitch terminal on the surgical microscope so that this marking is visible on the top.
6
MICROSCOPE connector
Connect this connector to the foot switch terminal on the surgical microscope.
7
Lock
Used for removing from a foot switch or surgical microscope.
2.6
Description
Pairing stickers 1
No.
Name
1
Pairing stickers No.1 – No.10
Description Attach the sticker matching the pairing indication on the paired foot switch onto the wireless unit. Refer to Section 3.6, “Pairing”.
MAJ-2301 INSTRUCTION MANUAL
17
Ch.2