INSTRUCTIONS
VISERA ELITE III VIDEO SYSTEM CENTER
Labels and Symbols
1
Important Information - Please Read Before Use
3
Summary of Equipment Functions
15
Chapter 1
Checking the Package Contents
17
Chapter 2
Nomenclature and Functions
19
Chapter 3
Installation and Connection
39
Chapter 4
Settings and functions in the Settings screen
105
Chapter 5
Inspection
223
Chapter 6
Operation
247
Chapter 7
Home button functions
263
Chapter 8
Functions available on the images screen
307
Reprocessing, Storage, and Disposal
323
OLYMPUS OTV-S700
Chapter 9
Chapter 10 Troubleshooting
331
Appendix
361
Contents
Contents Labels and Symbols ... 1 Important Information - Please Read Before Use ... 3 Intended purpose ... 3 Contraindications ... 3 Clinical benefit ... 3 Applicability of endoscopy and endoscopic treatment ... 3 Instruction manual ... 4 User qualifications ... 8 Instrument compatibility ... 8 Repair and modification ... 8 Classification of laser product ... 9 Signal words ... 9 Precautions ... 10 Precautions for use on and near the cardiac area ... 13 About security ... 14
Summary of Equipment Functions ... 15
Chapter 1 Checking the Package Contents ... 17 1.1
Checking the package contents ... 17
Chapter 2 Nomenclature and Functions ... 19 2.1
Symbols and descriptions ... 19
2.2
Front panel ... 27
2.3
Touch panel ... 28 Home ... 28 Image ... 29 Settings ... 30 Software keyboard ... 31
2.4
Rear panel ... 32
2.5
Side panels ... 34
2.6
Monitor ... 35
Chapter 3 Installation and Connection ... 39 3.1
Precautions for installation and connection ... 39
3.2
Installation and connection workflow ... 40
3.3
Installation of the equipment ... 41 Installation of the this instrument ... 42
3.4
Connection to the AC mains power supply ... 45 Using with a mobile workstation ... 47 Using without a mobile workstation ... 48
OTV-S700 INSTRUCTION MANUAL
i
Contents
3.5
Connection of the monitor ... 49 Compatible monitors ... 49 OEV321UH ... 50 OEV321UH Settings ... 52 OEV262H ... 56 OEV262H Settings ... 58 LMD-X310S ... 62 LMD-X310S settings ... 64 LMD-X550S ... 66 LMD-X550S settings ... 68 LMD-X310ST ... 70 LMD-X310ST settings ... 72 LMD-X550ST ... 74 LMD-X550ST settings ... 76 LMD-XH320ST ... 78 LMD-XH320ST settings ... 79 LMD-XH550ST ... 82 LMD-XH550ST settings ... 83
3.6
Connect the light source ... 86 Compatible light sources ... 86 CLL-S700 ... 86 CLV-S400 ... 88
3.7
Connection of the keyboard ... 90 Compatible keyboards ... 90 Keyboard ... 91
3.8
Connection of the video recorder ... 92 Compatible video recorders ... 92 IMH-200 ... 92 IMH-20 ... 94 IMH-10 ... 96 HVO-4000ST ... 98 nCare ... 101
3.9
Connection of the color video printer ... 103 Compatible color video printer ... 103
3.10 Connection of the foot switch ... 104 Compatible foot switch ... 104 MAJ-1391 ... 104
Chapter 4 Settings and functions in the Settings screen ... 105 4.1
List of settings and functions operated in Settings screen ... 105 Patient data ... 105 User presets ... 106 Security Settings ... 110 System Settings ... 111 Maintenance settings ... 112
4.2
ii
Display the Settings screen ... 114
OTV-S700 INSTRUCTION MANUAL
Contents
4.3
Operation in Patient data screen ... 115 Patient data ... 115 Display the Patient data screen ... 116 Register patient data ... 117 Edit patient data ... 118 Delete patient data ... 119 Load patient data ... 119
4.4
Operation in User presets screen ... 120 Display the user presets screen ... 120 Register new user presets ... 121 Copy user presets ... 123 Delete user presets ... 124 Edit user presets ... 125
4.5
User ID/Home screen custom button in user presets ... 128 Change user ID ... 128 Assign a function to a touch panel custom button ... 129
4.6
Custom switch settings in user presets ... 130 Assign a function to a remote switch of videoscope ... 130 Assign a function to a remote switch of camera head ... 131 Assign a function to a foot switch ... 132 Assign a function to a keyboard custom key ... 133
4.7
Settings about scope in user presets ... 134 Select magnification for 4K digital zoom ... 134 Set the display of the AF frame ... 135 Set Continuous AF Sensitivity ... 136
4.8
Settings about Release/Pre-freeze in user presets ... 137 Set the each recording destination for exam image obtained release 1 and 2 ... 137 Set the area to be recorded at release ... 138 Set the file format of the exam image ... 139 Set the Pre-freeze level ... 140
4.9
Settings about display on the monitor in user presets ... 141 Set the size of the endoscopic image ... 141 Set the display time of the index image ... 142 Set whether to display the Data display at the start of non-examination state ... 143 Select information to display ... 144 Select state of Data display at the start of examination state ... 145 Select text size of Data display ... 146 Select text color of Data display ... 147 Set the display position of message and index images ... 147 Set the display position of Data display in right side ... 148 Set the display time of the channel position displayed on the monitor ... 149
4.10 Settings about basic image adjustment in user presets ... 150 Set the iris mode ... 150 Set the iris area ... 151 Set the iris sensitivity ... 151 Set ON/OFF of the HDR (High Dynamic Range) ... 152 Set ON/OFF of the 4K up convert ... 153 OTV-S700 INSTRUCTION MANUAL
iii
Contents
4.11 Settings about image adjustment on each observation mode in user presets ... 154 Set the brightness mode ... 154 Set the brightness of endoscopic image ... 155 Set the contrast of the endoscopic image ... 156 Set the color tone of the endoscopic image ... 157 Set the color mode ... 158 Set the maximum gain of AGC ... 159 Set the enhancement mode of endoscopic image ... 160 Enable/disable NBI color adjustment ... 161
4.12 Security settings ... 162 Display the Security settings screen ... 162 Set enable/disable the security features ... 163 Setting the security level ... 165 Set the portable memory encryption ... 166 Set the restriction of recording patient data ... 167 Set the portable memory encryption/decryption password ... 168 Set sales/service login restriction ... 169 Set security targets ... 170 Manage account ... 171 Output audit logs ... 174 Initialize password of sales/service accounts ... 175 Login ... 175 Log out ... 176
4.13 System setup ... 177 Use the sequential setting ... 177 Use the individual setting ... 178
4.14 Settings in “Language/Display” (System setup) ... 180 Set the display language ... 180 Set the date display format ... 181 Set the date ... 182 Set the time ... 183 Set the patient data display mode ... 184 Set an initial comment displayed on the monitor ... 185 Set the brightness of the touch panel ... 186
4.15 Settings in “Video output” (System setup) ... 187 Select the video (3G-SDI(4K) OUT A to D terminal) ... 187 Set the signal standard of the video (3G/HD-SDI OUT1/2 terminal) ... 188 Set signal standard of the video (3G/HD-SDI recorder OUT terminal) ... 189 Set display/hidden of the Data display (3G/HDI recorder OUT terminal) ... 190
4.16 Settings in “Device connection” (System setup) ... 191 Set the IMH control terminal (Recorder terminal) ... 191 Set the Remote1/2 terminals ... 192 Set the model of keyboard connecting to the Keyboard terminal ... 193 Set enable/disable of sending use history (Not available) ... 194
iv
OTV-S700 INSTRUCTION MANUAL
Contents
4.17 Settings in “Image recording” (System setup) ... 194 Set whether to save exam image in the internal memory of this instrument ... 194 Set whether to record exam images with their patient data to portable memory ... 195 Set the still time at release ... 196 Set the still time at capture for color video printer ... 197
4.18 Settings in “Start/End exam” (System setup) ... 198 Set whether to start examination state at the start of recording ... 198 Set whether to remain the comment and patient data at turning OFF ... 199 Set whether to end examination state at turning OFF ... 199 Set whether to turn CLL lamp ON automatically ... 200
4.19 Maintenance ... 201 Display the Maintenance screen ... 201 Display test image for checking the image on the monitor ... 202 Check light intensity ... 202 Set maintenance notification ... 203 Display a history of messages ... 203 Output a history of messages to the portable memory ... 205 Format a portable memory to use with this product ... 205 Check whether portable memory is usable with this instrument ... 206 Back up ... 207 Export settings data in bulk ... 209 Export selected settings data ... 210 Restore this instrument by backup data ... 211 Import bulk settings data ... 212 Import selected settings data ... 214 Export a setting list (CSV file) ... 216 Display the model and serial number of peripheral devices ... 216 Display the OTV information ... 217 Display CLV/CLL information ... 217 Display and the edit the data in the scope ... 218 Set notification to inspect the endoscope ... 219 Format internal memory ... 220 System reset ... 221 Delete portable memory password in this instrument ... 222 Updade the OTV ... 222 Updade the CLL ... 222
Chapter 5 Inspection ... 223 5.1
Precautions of workflow ... 223
5.2
Inspection workflow ... 224
5.3
Connection of an endoscope ... 225 VISERA ELITE series videoscope ... 226 Fiberscope ... 227 Rigid endoscope and camera head ... 228
5.4
Inspection of the power supply ... 230
OTV-S700 INSTRUCTION MANUAL
v
Contents
5.5
Inserting the portable memory ... 231 Compatible portable memory ... 231 Portable memory ... 231
5.6
Monitor display inspection ... 233
5.7
Inspection of Data display on the monitor ... 233
5.8
Inspection of the endoscopic image ... 235
5.9
Inspection of the brightness adjustment function ... 237 Inspection of the automatic brightness adjustment ... 237 Inspection of the manual brightness adjustment ... 238
5.10 Inspection of the freeze function ... 240 5.11 Inspection of the release function ... 240 5.12 Inspection of the recording function ... 241 5.13 Inspection of the endoscopic image rotation function ... 243 5.14 Inspection of the custom switches ... 244 5.15 Inspection of the optical-digital observation function ... 245 Confirmation of available optical-digital observation ... 245 Inspection of optical-digital observation mode ... 245
5.16 After inspection ... 246
Chapter 6 Operation ... 247 6.1
Precautions for operation ... 247
6.2
Operation workflow ... 250
6.3
Turn ON the video system center and peripheral device ... 251
6.4
Adjust the white balance ... 252
6.5
Load a user presets ... 254
6.6
Enter or load a patient data ... 255 Enter a patient data with the touch panel ... 255 Enter a patient data with the keyboard ... 256 Load a patient data registered on this instrument ... 257
6.7
Observation and recording of the endoscopic image ... 258
6.8
Termination of the operation ... 259
6.9
Transportation ... 261
Chapter 7 Home button functions ... 263 7.1
Display the home screen ... 263
7.2
Home screen ... 264
7.3
Function list screen ... 265 Display the function list screen ... 265 List of functions in Function list screen ... 267
vi
OTV-S700 INSTRUCTION MANUAL
Contents
7.4
Functions in “Observ.” ... 270 Switch the observation mode ... 270 Switch enhancement mode ... 271 Switch the size of endoscopic image ... 272 Set the magnification of the digital zoom ... 273 Rotate the endoscopic image ... 274
7.5
Functions in “Record” ... 275 Freeze the endoscopic image (Freeze) ... 275 Record a still image (Release) ... 276 Record a still image on color video printer ... 276 Record video on a video recorder ... 277 Record a video clip on a video recorder ... 278 Record audio during recording video on a ovideo recorder ... 279 Set DVR function ... 280
7.6
Functions in “Bright/Color” ... 280 Adjust the brightness ... 280 Switch the brightness mode ... 281 Switch the iris sensitivity ... 281 Switch the iris mode ... 282 Switch the iris area ... 283 Switch the contrast ... 284 Switch enable/disable of HDR ... 285 Switch enable/disable of laser mode ... 286 Adjust the color tone ... 287 Switch the color mode ... 288 Switch enable/disable of NBI color adjustment ... 289
7.7
The functions in “Info.” ... 290 Switch display/hidden of Data display ... 290 Switch the text size of Data display ... 291 Switch the text color of Data display ... 292 Enter a comment ... 293 Switch display/hidden of the scope information ... 294 Switch display/hidden of the switch information ... 296 Switch display/hidden and move the arrow pointer on the monitor ... 298 Switch display/hidden of the cursor on the monitor ... 299
7.8
Functions in “Prepare/End exam” ... 300 Turn the lamp ON/OFF ... 300 Adjust white balance ... 300 Load a user presets ... 301 Enter the patient data (Preparation screen) ... 302 Load patient data (Preparation screen) ... 303 Execute the exam end ... 304 Saving user presets ... 304 Lock the touch panel ... 305
Chapter 8 Functions available on the images screen ... 307 8.1
Displaying the screen of image data ... 307 OTV-S700 INSTRUCTION MANUAL
vii
Contents
8.2
Operating the folders in which images are saved ... 308 Delete the folder with the images ... 308 Transfer a folder with images to portable memory ... 309
8.3
Operating an image files ... 310 Display an image saved in internal memory/portable memory ... 310 Deleting an image file ... 311 Transferring an imag file to portable memory ... 313 Printing an image ... 314
8.4
Displaying the memory information ... 316
8.5
Portable memory folder structure, folder name, file name ... 317 The structure of folders on portable memory and the detailed information of the image files and folders ... 317 Play back the images using the PC ... 319
Chapter 9 Reprocessing, Storage, and Disposal ... 323 9.1
Reprocessing ... 323 Surface disinfectant cleaner ... 324 Signs of degradation from reprocessing ... 325 Preparing equipment for reprocessing ... 325 Reprocessing procedure ... 326
9.2
Storage ... 328
9.3
Disposal ... 329
Chapter 10 Troubleshooting ... 331 10.1 Troubleshooting ... 331 10.2 Troubleshooting guide ... 332 10.3 Returning the video system center for repair ... 360
Appendix ... 361 Combination equipment ... 361 System chart ... 361
Specifications ... 365 Environment ... 365 Specifications ... 365
Security information of this instrument ... 379 Introduction ... 379 Usable peripheral devices ... 379 Product Security ... 379 Security Function for protection of security information ... 381 Security Function for external access protection ... 383 Audit log record and output function for inspection ... 384 Maintenance of security function ... 384
EMC information ... 385 Index ... 391
viii
OTV-S700 INSTRUCTION MANUAL
Labels and Symbols
Labels and Symbols Safety-related labels and symbols are attached on the locations shown below. If labels or symbols are missing or illegible, contact Olympus.
Rear panel Electric rating The product name, rated voltage, and frequency are shown. VISERA ELITE III VIDEO SYSTEM CENTER MODEL
OLYMPUS OTV-S700
POWER INPUT:
100–240 V
50/60 Hz 170 VA
Indicates to refer to the instruction manual for the cable to be connected. Refer to the instruction manual.
Potential equalization terminal
Manufacturing date
Serial number
MEDICAL DEVICE Medical device CE marking
Crossed-out wheeled bin’ symbol
Authorized representative in the European Community
Manufacturer
OTV-S700 INSTRUCTION MANUAL
1
Labels and Symbols
Front panel
Indicates to refer to this instruction manual for the degree of protection against electric shock of this product. Refer to “ Combination that this product becomes CF type” on page 370.
UDI label A label required by some countries’ regulations regarding identification of medical device also known as Unique Device Identification (UDI).
Back cover of this instruction manual Symbol
Description Manufacturer
Authorized representative in the European Community
Translation
Importer (into European Union)
2
OTV-S700 INSTRUCTION MANUAL
Important Information - Please Read Before Use
Important Information - Please Read Before Use
Intended purpose This video system center is intended to process electronic signals transmitted from a video endoscope/camera head and output image signal to monitor, and to be used with Olympus endoscopes, video endoscopes, camera heads, light sources, monitors and other ancillary equipment for endoscopic diagnosis, treatment, and observation.
Contraindications TYPE BF endoscopes connected to this video syste center must never be applied directly to the heart. Leakage current from the TYPE BF applied part may be dangerous and cause ventricular fibrillation or otherwise seriously affect the cardiac function of the patient. Accordingly, always adhere to the following points. − Never apply the TYPE BF endoscope connected to this video system center to the heart or any area near the heart. − Never allow an EndoTherapy accessory or another endoscope applied to or near the heart to come in contact with the TYPE BF endoscope connected to this video system center.
Clinical benefit Supports to achieve the clinical benefit of connected endoscopes, camera heads, light sources, and other ancillary equipment by providing endoscopic diagnosis, treatment, and observation.
Applicability of endoscopy and endoscopic treatment If there is an official standard on the applicability of endoscopy and endoscopic treatment that is defined by the hospital’s administration or other official institutions such as academic societies on endoscopy, follow that standard. Before starting endoscopy and endoscopic treatment, thoroughly evaluate its properties, purposes, effects, and possible risks (their natures, extent, and probability). Perform endoscopy and endoscopic treatment only when its potential benefits are greater than its risks. Fully explain to the patient the potential benefits and risks of the endoscopy and endoscopic treatment as well as any examination/treatment methods that can be performed in its place, and perform the endoscopy and endoscopic treatment only after obtaining the consent of the patient. Even after starting the endoscopy and endoscopic treatment, continue to evaluate the potential benefits and risks, and immediately stop the endoscopy/treatment and take proper measures if the risks to the patient become greater than the potential benefits. OTV-S700 INSTRUCTION MANUAL
3
Important Information - Please Read Before Use
Instruction manual This instruction manual contains essential information on using the video system center safely and effectively. Before use, thoroughly review this manual and the manuals of all equipment that will be used during the procedure and use the equipment as instructed. Keep this and all related instruction manuals in a safe, accessible location. If you have any questions or comments about any information in this manual, contact Olympus.
Terms used in this manual Camera head: The camera head is a device that converts endoscopic images taken by a fiberscope or rigid endoscope into electrical signals.
Color video printer: The color video printer is a device that prints the frozen video image.
Video recorder: The video recorder is a device that records the video.
Video system center: The video system center is a device that processes the signal from the endoscope and sends the endoscopic image to the monitor.
Healthcare facility grade wall mains outlet: The healthcare facility grade wall mains outlet is a wall AC mains power outlet socket having the exclusive terminal for grounding.
Isolation transformer: The isolation transformer is a safety device that is used to isolate the noninsulated equipment with potentially high leakage currents to decrease the possibility of an electric shock.
Automatic brightness adjustment: The automatic brightness adjustment automatically adjusts the intensity of the light emitted from the light source so that the endoscopic image will be maintained at constant brightness even if the distance between the distal end of the endoscope’s insertion tube and the subject changes.
Manual brightness adjustment: The manual brightness adjustment function is used to adjust manually the intensity of the light emitted from the light source.
4
OTV-S700 INSTRUCTION MANUAL
Important Information - Please Read Before Use
Image sensor: The image sensor is a device that converts light into electrical signals.
Electric zoom/Digital zoom: The electric/digital zoom function changes the zoom ratio of the image.
Iris: The iris function is used to electrically measure the brightness of an endoscopic image.
Color adjustment: Color adjustment adjusts the color balance and the chroma on the monitor.
AF (Auto Focus): AF is the function to focus on a subject automatically.
C-AF (Continuous Auto Focus) C-AF is the function which automatically keeps the focus on the subject even if the distance to the subject changes.
Laser mode This mode can reduce the halation that occurs when this instrument is used in combination with a laser device. To reduce the halation, filter and electronic shutter are used.
Freeze: The freeze function makes a frozen image of a live image.
Pre-freeze: The pre-freeze function is used to display the image with the least blur when being frozen.
Release: The release function is used to record an endoscopic image.
Capture: Stores the image in the color video printer.
Index image: The index image is displayed on the monitor when executing the release function.
Contrast: This is the ratio of brightness between the brightest and darkest areas in an image.
OTV-S700 INSTRUCTION MANUAL
5
Important Information - Please Read Before Use
Structure enhancement: Structure enhancement is an image processing technique that electrically emphasizes the detailed patterns and edges of an image to increase sharpness.
AGC (Automatic Gain Control): The AGC is used to increase the brightness of an endoscopic image electrically when the brightness of the image is dark because the distance between the endoscope’s distal end and the object is too long.
Image rotation: The image rotation function is a function that rotates the endoscopic image by 180 degrees.
Portable memory: A digital medium for storage of images, etc.
Internal memory: This is space to store the frozen images, patient information, and user settings data.
Wash-out: Wash out is the inability to see details in the endoscopic image due to excessive brightness.
HDTV: This is a format for high-resolution video transmission.
HDR (High Dynamic Range) It is a display technology that can express a wider range of brightness than before.
4K: This is a format for high-resolution video transmission featuring higher definition than the HD format.
Data display: Information such as “date and time” and “patient data” displayed on the monitor.
Endoscope information: Information such as “model name” or “channel inner diameter” of the endoscope connected to this instrument.
WLI (White Light Imaging) observation: This is observation using white light.
6
OTV-S700 INSTRUCTION MANUAL
Important Information - Please Read Before Use
YE (Yellow Enhance) observation: This is observation which emphasizes the yellow color of the WLI observation.
Optical-digital observation: This is observation using specific filtered light.
NBI (Narrow Band Imaging) observation: This is optical-digital observation using blue and green narrow band light.
Custom switch: The custom switch is a general term for the buttons, keys, and switches to which functions can be assigned: “CUSTOM” key on the keyboard, remote switch on the endoscope, remote switch on the foot switch, and custom button on the touch panel.
Software keyboard: The keyboard displayed on the touch panel.
Memory page: Memory page is the area to store the images that the color video printer has.
Patient data/Patient information: Following items are basic information of identification for patient: patient ID, name, sex. date of birth and ages.
Exam image: Image captured in endoscopy exam.
Exam information: It includes patient information and exam image which are made and managed in each examination.
Setting information: They are set as user settings, system settings and security settings.
Backup information: They are transferred when backup function is executed. refer to “ Back up” on page 207.
Administrator privilege: This privilege can manage security functions of OTV-S700 and restrict function used by Olympus representatives and accounts with General user privilege.
General user privilege: This privilege is permitted to access to information in this instrument but cannot manage security functions. OTV-S700 INSTRUCTION MANUAL
7
Important Information - Please Read Before Use
Account information: It consists of ID and password and is managed in each its privilege.
Short clip When recording a movie, a normal movie and a short movie are recorded.
OSS (Open Source Software) This is a generic term for a group of software whose source code can be used, researched, reused, modified, extended, and redistributed to the extent that it complies with the pledge set by the author. This software is used in some parts of this product.
User qualifications If there are official standards for user qualifications to perform endoscopy and endoscopic surgery that are defined by the hospital’s medical administrators or other official institutions, such as academic societies on endoscopic surgery, follow those standards. If there are no official qualification standards, the operator of this instrument must be a physician approved by the medical safety manager of the hospital or person in charge of the department.
Instrument compatibility Refer to “ System chart” on page 361 to confirm that the video system center is compatible with the peripheral device being used. Using incompatible equipment may result in patient injury or equipment damage and makes it impossible to obtain the expected functionality. This instrument complies with the EMC standard for medical electrical equipment, edition 4 (IEC 60601-1-2: 2014). When connecting to an instrument that complies with a previous edition of the EMC standard for medical electrical equipment edition, the EMC characteristics could be vulnerable.
Repair and modification The video system center does not contain any user-serviceable parts. Do not disassemble, modify, or attempt to repair it; patient or operator injury, equipment damage and/or the impossibility to obtain the expected functionality can result. Some problems that appear to be malfunctions may be correctable by referring to Chapter 10, “Troubleshooting”. If the problem cannot be resolved using the information in Chapter 10, contact Olympus. This instrument is to be repaired by Olympus technicians only. Olympus is not liable for any injury or damage which occurs as a result of repairs attempted by non-Olympus personnel.
8
OTV-S700 INSTRUCTION MANUAL
Important Information - Please Read Before Use
Classification of laser product The video system center is CLASS 1 LASER PRODUCT.
Signal words The following signal words are used throughout this manual:
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices or potential equipment damage.
NOTE
Indicates additional helpful information.
OTV-S700 INSTRUCTION MANUAL
9
Important Information - Please Read Before Use
Precautions Follow the warnings and cautions given below when handling the video system center. This information is to be supplemented by the warnings and cautions given in each chapter.
DANGER • Strictly observe the following precautions. Failure to do so may place the patient and medical personnel in danger of an electric shock. − When the video system center is used to examine a patient, do not allow metal parts of the endoscope or its accessories to touch metal parts of other system components. Such contact may cause unintended current flow to the patient. − Keep fluids away from all electrical equipment. If fluids are spilled on or into the unit, stop operation of the video system center immediately and contact Olympus. − Do not prepare, inspect, or use the video system center with wet hands. • Never install and operate the video system center in locations where: − The concentration of oxygen is high − Oxidizing agents (such as nitrous oxide (N2O)) are present in the atmosphere − Flammable gases are present in the atmosphere − Flammable liquids are near
WARNING • Do not use this instrument for any purpose other than its “ Intended purpose” on page 3. • In case of video system center failure or malfunction, always keep another video system center ready for use. • Do not look directly into the distal end of the endoscope or distal end of the light guide when they are emitting light. The intense light may cause eye injury. • Operate the endoscope or perform endoscopic treatment while observing the endoscopic live image. If operating the endoscope or performing endoscopic treatment while freezing or playing back the endoscopic image, patient injury may occur. • Do not apply excessive force to the video system center and/or other instruments connected. Otherwise, damage and/or malfunction can occur. • Do not use the video system center in any place where it may be subject to strong electromagnetic radiation (for example, in the vicinity of a microwave therapeutic equipment, MRI, wireless set, short-wave therapeutic equipment, cellular/portable phone, etc.). This may impair the performance of the video system center.
10
OTV-S700 INSTRUCTION MANUAL
Important Information - Please Read Before Use
WARNING • Output the observation image directly to the observation monitor and do not relay it through peripheral equipment. Depending on the condition of the equipment, the endoscope image may be lost. • SDI signals transmit signals to multiple peripheral devices in a daisy chain connection. If the power of a device in the middle of the connection is turned off, the video signal will not be supplied to the subsequent devices. • Before use, make sure that there is no electromagnetic interference between this product and other medical electronic devices used in conjunction with it. Failure to do so may result in loss of live images or malfunction of the product. • To avoid electromagnetic interference from equipment other than this product and this system, care should be taken to avoid excessive proximity or stacking. Failure to do so may result in loss of live images or malfunction of the product. • Although the illumination light emitted from the endoscope’s distal end is required for endoscopic observation and treatment, it may also cause alteration of living tissues such as protein denaturation of biological tissue by inappropriate use. Observe the following warnings on the illumination. − Always set the minimum required brightness. The brightness of the image on a video monitor may differ from the actual brightness at the distal end of an endoscope. − Do not continue observation in proximity to tissue or keep the distal end of the endoscope in contact with living tissue for a long time. − When discontinuing the use of the endoscope, extinguish the lamp by tapping the lamp button.
CAUTION • Use the video system center only under the conditions described in “ Environment” on page 365. Otherwise, improper performance, compromised safety, and/or equipment damage may result. • Do not use the product in a manner that deviates from what is described in this instruction manual. If you deviate from the instructions, the leaked laser beam may cause eye damage. • Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. • Do not allow a foreign object to penetrate the inside of the video connector socket, portable memory port, and terminals on the rear panel. The video system center may malfunction. • Do not use a pointed or hard object to press the buttons on the front panel, touch panel, and/or keyboard. This may damage the buttons. OTV-S700 INSTRUCTION MANUAL
11