Instruction Manual
112 Pages

Preview
Page 1
272145 NE-C25-all
11/5/07
2:28 PM
Page 1
INSTRUCTION MANUAL
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner.
ENGLISH
FRANÇAIS
ESPAÑOL
PORTUGUÊS
Compressor Nebulizer System MODEL NE-C25
272145 NE-C25-all
11/5/07
2:28 PM
Page 2
CONTENTS Before Using the Device Introduction... 3 Safety Information Operating the Device... 4 Risk of Electrical Shock... 6 Maintenance and Storage... 6 Know Your Unit Main Unit... 7 Components and Replacement Parts... 8
Operating Instructions Preparing the Nebulizer for Use... 9 Attaching the Air Tubing... 12 Using the Device... 13
Care and Maintenance Cleaning after Each Use... 16 Daily Disinfecting... 17 Changing the Air Filter... 19 Caring for the Device... 20
Troubleshooting Troubleshooting Guide... 22 Warranty... 23 FCC Statement... 24 Specifications... 25
The illustrations shown in this instruction manual are image drawings and may differ slightly from the appearance of the actual product.
2
272145 NE-C25-all
11/5/07
2:28 PM
Page 3
Before Using the Unit
INTRODUCTION Thank you for purchasing the OMRON® CompAir® XLT® NE-C25 Compressor Nebulizer System.
Fill in for future reference. DATE PURCHASED: _____________ SERIAL NUMBER: _______________
Staple your purchase receipt here
This product was developed for the successful treatment of asthma, allergies and other respiratory disorders. The compressor forces air to the nebulizer. When the air enters the nebulizer, it converts the prescribed medication into a mist of microscopic droplets that can easily be inhaled. Your NE-C25 CompAir® XLT® comes with the following components: • Compressor • 5 Replacement Filters • Carrying Bag • Jet-Air® Nebulizer Kit • Air Tubing • Mouthpiece • User Registration Card • Instruction Manual (English, Spanish, Portuguese, French) The following optional accessories are sold separately: • Adult Mask • Child Mask
The CompAir® XLT® is a prescription medical device. Operate this device only as instructed by your physician and/or licensed healthcare practitioner.
SAVE THESE INSTRUCTIONS 3
272145 NE-C25-all
11/5/07
2:28 PM
Page 4
SAFETY INFORMATION To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE Read all the information in the instruction book and any other literature included in the box before using the unit. For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner. Do not block the ventilation slots located on the sides of the device. Do not place the device where the ventilation slots may be obstructed during operation. This could result in the compressor overheating or malfunctioning. Do not cover the compressor with a blanket, towel, or any other type of cover during use. This could result in the compressor overheating or malfunctioning. Do not use the device where the device may be exposed to flammable gas or vapors. Do not use tap or mineral water in the nebulizer kit for nebulizing purposes. Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or masks before using them for the first time after purchase. If the device has not been used for a long period of time clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or masks before using them. Always dispose of any remaining medication in the medication cup after each use. Use fresh medication each time you use the device. Provide close supervision when this device is used by, on, or near infants, children or compromised individuals. Do not insert any object into the compressor. Make sure the air filter is clean. If the air filter has changed color or has not been used for 30 days, replace the filter. 4
272145 NE-C25-all
11/5/07
2:28 PM
Page 5
SAFETY INFORMATION OPERATING THE DEVICE (continued) Do not operate without an air filter. Make sure the nebulizer kit is correctly assembled, the air filter is properly installed, and the air tubing is correctly connected to the compressor and the nebulizer kit. Air may leak from the air tubing during use if not securely connected. Inspect the compressor (main unit) and the nebulizer parts each time before using the device. Make sure no parts are damaged, the nozzle and air tubing are not blocked and the compressor operates normally. Do not use the device if the air tubing is bent. Do not block the air filter cover. Do not alter the baffle, the nozzle in the medication cup or any part of the nebulizer kit. Do not add more than 6ml of medication to the medication cup. Do not operate the device at temperatures greater than +104˚F (+40˚C). Do not tilt the nebulizer kit so the angle of the kit is greater than 45˚. Medication may flow into the mouth. Do not shake the nebulizer kit while using the device. Do not subject the compressor or any of the components to strong shocks, such as dropping on the floor. This device is approved for human use only. Do not disassemble or attempt to repair the device or components. Operate the device only as intended. Do not use the device for any other purpose. Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Changes or modification not approved by Omron Healthcare will void the user warranty.
5
272145 NE-C25-all
11/5/07
2:28 PM
Page 6
SAFETY INFORMATION RISK OF ELECTRICAL SHOCK Do not plug or unplug the power cord into the electrical outlet with wet hands. Do not immerse the compressor (main unit) in water or other liquid. Do not spill water or other liquids on the compressor and power cord. The compressor and power cord are not waterproof. If liquid spills on these parts, immediately unplug the power cord and wipe off the liquid with gauze or other soft absorbent material. Do not use or store the device in humid locations, such as a bathroom. Use the device within the operating temperature and humidity. Do not use a cellular phone near the device. It may result in an operational failure. Do not overload power outlets. Plug the device into an outlet with the appropriate voltage. Do not use extension cords. Plug the power cord directly into the electrical outlet. Unplug the power cord from the electrical outlet after using the device. Unplug the power cord from the electrical outlet before cleaning the device.
MAINTENANCE AND STORAGE Keep the device out of the reach of unsupervised infants and children. The device may contain small parts that can be swallowed. Do not leave the cleaning solution in the nebulizer parts. Rinse the nebulizer parts with clean hot tap water after disinfecting. Wash the nebulizer parts after each use. Dry the parts immediately after washing. Do not store the air tubing with moisture or medication remaining in the air tubing. This could result in infection as a result of bacteria. Store the device and the components in a clean, safe location. Do not carry or leave the nebulizer kit with medication in the medication cup. Do not place or attempt to dry the device, components, or any of the nebulizer kit parts in a microwave oven. Do not wrap the power cord around the compressor (main unit).
6
272145 NE-C25-all
11/5/07
2:28 PM
Page 7
KNOW YOUR UNIT Compressor: Mouthpiece AC Power Cord
Power Switch
Air Tubing Connector
Ventilation Slots
Air Filter Cover Jet Air Nebulizer Kit
Nebulizer Kit Holder
Nebulizer Kit: Air Tubing
Top of Jet Air Nebulizer
Mouthpiece
Baffle
Nozzle
6 5 4 3 2 1
Nebulizer Medication Cup
Air Tubing Connector 7
272145 NE-C25-all
11/5/07
2:28 PM
Page 8
KNOW YOUR UNIT Components: Air Tubing
Air Filters Package of 5
Instruction Manual
Air Filter Cover
User Registration Card
Carrying Bag
Child Mask
Nosepiece
INSTRUCTION MANUAL ®
Compressor Nebulizer MODEL NE-C25
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner
Optional Accessories: Adult Mask
Accessories and Replacement Parts
Model No.
Adult Mask...9920 Air Filters (Package of 5)...9930 Child Mask...9921 Nosepiece...C911 JetAir® Reusable Nebulizer Kit Set...9914 Includes Nebulizer Kit, Mouthpiece and Air Tubing JetAir® Disposable Nebulizer Kit Set...9973 Includes Nebulizer Kit, Mouthpiece and Air Tubing Instruction Manual...NE-C25INST Rev 8
272145 NE-C25-all
11/5/07
2:28 PM
Page 9
PREPARING THE NEBULIZER FOR USE WARNING Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or masks before using them for the first time after purchase. WARNING If the device has not been used for a long period of time clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or masks before using them.
For directions on cleaning and disinfecting refer to page 16 and page 17. CAUTION Make sure the air filter is clean. If the air filter has changed color or has not been used for 30 days, replace the filter.
For directions on changing the air filter refer to page 19. 1. Turn the power switch off. Make sure the power switch is in the O position. 2. Plug the power plug into the electrical outlet. WARNING Do not plug or unplug the power cord into the electrical outlet with wet hands. CAUTION Do not overload power outlets. Plug the device into the appropriate voltage outlet. CAUTION Do not use extension cords. Plug the power cord directly into the electrical outlet.
3. Gently twist the nebulizer kit counter clockwise and lift the top of the nebulizer kit off.
Baffle
4. Make sure the baffle is placed securely in the medication cup. CAUTION Do not alter the baffle, the nozzle in the medication cup or any part of the nebulizer kit. 9
6 5 4 3 2 1
272145 NE-C25-all
11/5/07
2:28 PM
Page 10
Operating Instructions
PREPARING THE NEBULIZER FOR USE 5. Add the correct amount of prescribed medication to the medication cup. WARNING For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner. WARNING Do not spill water or other liquids on the compressor and power cord. The compressor and power cord are not waterproof. If liquid spills on these parts, immediately unplug the power cord and wipe off the liquid with gauze or other soft absorbent material. WARNING Do not use tap or mineral water in the nebulizer kit for nebulizing purposes. CAUTION Do not add more than 6ml of medication to the medication cup.
6. Assemble the nebulizer kit by gently twisting the top and bottom sections together clockwise. Make sure the two sections fit securely.
10
272145 NE-C25-all
11/5/07
2:28 PM
Page 11
PREPARING THE NEBULIZER FOR USE 7. Attach the desired inhalation accessory.
USING THE MOUTHPIECE
Attach the mouthpiece to the top of the nebulizer kit.
USING THE NOSEPIECE
Attach the nosepiece to the top of the nebulizer kit.
USING THE CHILD MASK
Attach the mask to the top of the nebulizer kit.
USING THE ADULT MASK
Attach the mask to the top of the nebulizer kit.
11
272145 NE-C25-all
11/5/07
2:28 PM
Page 12
ATTACHING THE AIR TUBING 1. Push one end of the Air Tubing onto the Air Tubing Connector on the front side of the compressor. 2. Push the other end of the Air Tubing onto the Air Tubing Connector on the bottom of the Nebulizer Kit. NOTE: Keep the nebulizer kit upright when attaching the air tube. Medication may spill out of the medication cup.
CAUTION Make sure the nebulizer kit is correctly assembled, the air filter is properly installed, and the air tubing is correctly connected to the compressor and the nebulizer kit. Air may leak from the air tubing during use if not securely connected. CAUTION Do not use the device if the air tubing is bent.
3. Use the Nebulizer Kit Holder as a temporary holder for the nebulizer kit.
12
272145 NE-C25-all
11/5/07
2:28 PM
Page 13
USING THE DEVICE WARNING Do not use the device where the device may be exposed to flammable gas or vapors. WARNING Do not use or store the device in humid locations, such as a bathroom. Use the device within the operating temperature and humidity. CAUTION Provide close supervision when this device is used by, on, or near infants, children or compromised individuals. CAUTION Do not use a cellular phone near the device. It may result in an operational failure. CAUTION Inspect the compressor (main unit) and the nebulizer kit parts each time before using the device. Make sure no parts are damaged, the nozzle and air tubing are not blocked and the compressor operates normally.
1. Hold the nebulizer kit as illustrated on the right.
CAUTION Do not tilt the nebulizer kit so the angle of the kit is greater than 45˚. Medication may flow into the mouth. CAUTION Do not shake the nebulizer kit while using the device.
2. Turn the power switch on. The power switch is in the (1) position. NOTE: The compressor starts. Make sure the nebulization begins and aerosol is generated.
To stop the nebulization, turn the power switch to the off
13
position.
272145 NE-C25-all
11/5/07
2:28 PM
Page 14
USING THE DEVICE WARNING Do not block the ventilation slots located on the sides of the device. Do not place the device where the ventilation slots may be obstructed during operation. This could result in the compressor overheating or malfunctioning. WARNING Do not cover the compressor with a blanket, towel, or any other type of cover during use. This could result in the compressor overheating or malfunctioning. CAUTION Do not block the air filter cover.
3. Inhale medication as instructed by your physician or licensed healthcare practitioner. USING THE MOUTHPIECE
Insert the mouthpiece into your mouth. Inhale medication breathing normally. Exhale normally through the mouthpiece. USING THE NOSEPIECE
Inhale the medication through the nosepiece. Exhale through the mouth. USING THE CHILD MASK or THE ADULT MASK
Place the mask over the nose and mouth. Pull the elastic strap over the head. Gently pull on the strap to securely hold the mask over the nose and mouth. Inhale the medication. Exhale normally though the mask. 4. Complete the treatment. WARNING For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner.
14
272145 NE-C25-all
11/5/07
2:28 PM
Page 15
USING THE DEVICE 5. At the end of the treatment, turn the power switch off. The power switch is in the position. The compressor turns off and nebulization stops. 6. Disconnect the Air Tubing from the Nebulizer Kit. Grasp the end of the Air Tubing connected to the nebulizer kit and gently pull down to disconnect the Air Tubing from the Air Tubing Connector on the bottom of the nebulizer kit. 7. Check the Air Tubing. No condensation or moisture should remain in the Air Tubing. WARNING Do not store the air tubing with moisture or medication remaining in the air tubing. This could result in infection as a result of bacteria.
If any condensation or moisture remains in the air tubing, remove the moisture from the air tubing. Follow the directions below: 1. Make sure the Air Tubing is still connected to the Air connector on the front side of the compressor. 2. Turn the power switch on. The power switch is in the (1) position. The compressor will start and pump air through the air tubing to expel the moisture. 3. Turn the power switch off. 8. Disconnect the Air Tubing from the compressor. Grasp the end of the Air Tubing and gently pull the Air Tubing off the Air Connector on the front side of the compressor. 9. Unplug the device from the electrical outlet. CAUTION Unplug the power cord from the electrical outlet after using the device.
15
00V
AC1
272145 NE-C25-all
11/5/07
2:28 PM
Page 16
CLEANING AFTER EACH USE Following the cleaning instructions after each use will prevent any remaining medication in the bottle from drying resulting in the device not nebulizing effectively and will help prevent infections. WARNING Wash the nebulizer parts after each use. Dry the parts immediately after washing.
1. Remove the inhalation accessory (mouthpiece, mask, or nosepiece) from the nebulizer kit. 2. Disconnect the air tubing from the nebulizer kit. 3. Gently twist the nebulizer kit counterclockwise and lift to separate the nebulizer kit into two sections. 4. Remove the baffle from the bottom section of the nebulizer kit. 5. Discard remaining medication in the medication cup. WARNING Always dispose of any remaining medication in the medication cup after each use. Use fresh medication each time you use the device.
6. Rinse all the parts of the nebulizer kit and the mouthpiece, nosepiece or mask with hot tap water. You may also wash these parts in a dishwasher. Remove the parts after the wash and rinse cycle is completed. DO NOT wash the mask in a dishwasher. CAUTION Place the nebulizer pieces in a basket recommended for dishwasher use. Place the basket on the top shelf to avoid any damage to the nebulizer kit.
7. Rinse the mask with hot tap water. 8. Hand dry or air dry in a clean environment using a soft, clean, lint-free cloth. 9. Assemble the nebulizer kit and store the nebulizer kit in a dry, sealed bag in the storage pocket of the carrying bag.
16
272145 NE-C25-all
11/5/07
2:28 PM
Page 17
DAILY DISINFECTING You can disinfect daily by soaking the parts in a vinegar solution or using a commercially available medical disinfectant. If your physician or respiratory therapist specifies a different cleaning procedure follow their instructions. Disinfect the nebulizer kit and the mask, nosepiece or mouthpiece after the last treatment of the day. VINEGAR METHOD
1. Make a solution of 1 part white vinegar and 3 parts distilled water. Make enough solution to submerge the parts. 2. Remove the inhalation accessory (mouthpiece, mask, or nosepiece) from the nebulizer kit. 3. Disconnect the air tubing from the nebulizer kit. 4. Gently twist and pull the nebulizer kit counterclockwise and lift to separate the nebulizer kit into two sections. 5. Remove the baffle from the bottom section of the nebulizer. 6. Wash all the parts of the nebulizer kit, the mouthpiece, nosepiece or mask in warm water and a mild detergent. Rinse in hot tap water. You may also wash the nebulizer kit, mouthpiece or nosepiece in a dishwasher. DO NOT wash the mask in a dishwasher. CAUTION Place the nebulizer pieces in a basket recommended for dishwasher use. Place the basket on the top shelf to avoid any damage to the nebulizer kit.
7. Submerge the parts in the white vinegar and distilled water solution for 30 minutes. 8. Remove the parts and discard the solution. Rinse the parts with hot tap water.
17
272145 NE-C25-all
11/5/07
2:28 PM
Page 18
DAILY DISINFECTING 9. Hand dry or air dry in a clean environment using a soft, clean, lint-free cloth. 10. Assemble the nebulizer kit and store the nebulizer kit in a dry, sealed bag. Place sealed bag in the storage pocket of the carrying bag. WARNING Store the device and the components in a clean, safe location. MEDICAL DISINFECTANT METHOD
Consult your physician or respiratory therapist regarding the use of medical disinfectant cleaners. Carefully follow the instructions supplied by the manufacturer of the medical disinfectant.
18
272145 NE-C25-all
11/5/07
2:28 PM
Page 19
CHANGING THE AIR FILTER Change the air filter every 30 days even if the air filter does not appear dirty. If the air filter appears dirty, or if water or medication has spilled on the air filter replace with a new air filter immediately. 1. Pull the air filter cover to remove it from the front side of the compressor. 2. Remove the dirty filter with a small pointed object. CAUTION Do not attempt to wash or clean the air filter. Damp air filters can cause blockages. Do not substitute cotton or any other material for the air filter. CAUTION Wash the air filter cover regularly to prevent any blockage in the cover. Do not boil. Make sure the cover is dry before inserting the new air filter. CAUTION Do not operate without air filter.
3. Insert a new air filter into the air filter cover. CAUTION Before inserting the new air filter make sure the air filter is clean and free of dust. Use only the Omron air filter designed for this device.
4. Put the air filter cover back on the compressor.
19
272145 NE-C25-all
11/5/07
2:28 PM
Page 20
CARING FOR THE DEVICE To keep your device in the best condition and protect the unit from damage follow these directions: CAUTION Do not subject the compressor or any of the components to strong shocks, such as dropping on the floor. CAUTION Use only Omron authorized parts and accessories. CLEANING THE COMPRESSOR
Clean the casing of the main unit by using a soft cloth moistened with water or a mild detergent. Do not use abrasive cleaners. Dry the casing immediately using a soft clean cloth. WARNING Do not immerse the compressor (main unit) in water or other liquid. CAUTION Unplug the power cord from the electrical outlet before cleaning the device. CAUTION Do not insert any object into the compressor. STORING THE DEVICE
1. Put the nebulizer kit and the inhalation accessory (mouthpiece, nosepiece or mask) in a dry, sealed bag. Place the bag in the storage pocket of the carrying bag. 2. Coil the air tubing and place in the storage pocket. 3. Place the compressor in the carrying bag. CAUTION Do not wrap the power cord around the compressor (main unit).
20