Dental Electrosurgery Units

SENSIMATIC 700SE Instructions rev Sept 2010

Instructions

4 Pages

7) Recontour Edentulous Ridges-Removal of redundant soft tissue makes impression taking and fitting complete and partial dentures more accurate and comfortable. Ideal for preparation of ovate pontic sites. Electrode recommendations: #T2; T5; #T8; #T16; #P4.  Caution Federal Law restricts this device to sale by or on the order of a properly licensed practitioner.  8) Removal of Hyperplastic and Hypertrophic Tissue-Ideal in case of medication-induced gingival hyperplasia. Electrode recommendations: #T2; #T5; #T8; #T16; #P4. 9) Pericoronitis-Fast, easy removal of pericoronal tissue above partially-erupted third molars. Electrode recommendations: #T5; #T8; #T16.  10) Performing Gingivectomy or Gingivaplasty-Predictably reduce depth of shallow periodontal pockets. Electrode recommendations: #T2; #T5; #T8; #T16; #P4. 11) Frenectomy-Relieve excess muscle tension and tissue pull and improve esthetics. Electrode recommendation: #T2.  12) Exposing Teeth with Delayed Eruption-Allow orthodontic eruption to proceed. Electrode recommendations: #T2; #T5; #T8; #T16.  13) Performing Tissue Biopsy-Controlled removal of suspect lesions with minimal tissue damage. Electrode recommendations: #T2; #T5.  14) Exposing Pre-Placement Implant Sites-Clean, smooth gingival incisions with control of bleeding for fast exposure of the implant placement site. (IMPORTANT: AVOID CONTACT WITH THE BONE.) Electrode recommendations: #T2; #T8; #T16. 15) Periodontal Flaps-Controlled, sharp incisions for better healing. Electrode recommendation: #T2.  16) Controlling Bleeding of Nicked Gingival Papillae-For accurate impressions after crown preparation. Electrode recommendation: #P4. 17) Reshaping of Gingival Sulcus into Healthy U-shape-After crown preparation. Electrode recommendation: #P4.  300 Executive Drive, PO Box 9004, Edgewood, NY 11717 • Phone: 631-249-1134 Fax: 631-249-1242 • Web: www.parkell.com • Email: info@parkell.com European Authorized Representative: (Not a dealer/distributor) EMERGO EUROPE, Molenstraat 15, 2513 BH, The Hague, The Netherlands Tel: +31 (0)70 345 8570 Fax: +31 (0)70 346 7299  IMPORTANT-READ FIRST This manual, in whole or in part, should not be considered a substitute for formal training. Appropriate education in the use of electrosurgical procedures is REQUIRED prior to undertaking any procedures on patients.  DEVICE DESCRIPTION The Sensimatic™ 700SE Electrosurge is a solid-state dental electrosurgery unit. It features a low-impedance, high-frequency output not found in older, vacuum tube-based electrosurgery units. Once set for the case at hand, the device adjusts for changes in tissue thickness automatically, to compensate for different resistance encountered in the soft tissue being treated. INTENDED USE/INDICATIONS Model 700SE is useful in restorative and operative dentistry, as well in the performance of oral surgery, periodontics, orthodontics, endodontics, prosthodontics, and crown and bridge procedures. From the dozens of uses cited in current literature, here are some areas where electrosurgery has proven useful in the practice of general dentistry. • For impression taking, to gain access to margins of prepared teeth or to remove interproximal tissue. • To extend the clinical height of crowns. • Gingivectomy. • Removal of pericoronal tissue on 3rd molars. • Biopsy. • To reduce and remove swollen and hypertrophied gum tissue around the necks of teeth, to gain better access and visibility. • To plane tissue of edentulous region prior to making impressions for prosthodontics. • Control of bleeding prior to cementation or other restorative procedures. • Incision, excision, drainage or coagulation of minor periodontal conditions. • Exposure of unerupted teeth. • For surgery with antisepsis and hemostasis. • Implant surgery-IMPORTANT NOTE: Although electrosurgical devices allow clean, smooth incisions with lessened bleeding, they are recommended only for first-stage, implant placement surgery. Metal implants should not be touched with an active electrode. Therefore, use of these devices in later stages of implant surgical procedures is to be avoided. CONTRAINDICATIONS • Do not use this device around persons wearing a pacemaker or other implantable electronic devices.  A00619rev*910 8  1
File Type: PDF
File Size: 650 KB
File Name: parkell - A00619 - SENSIMATIC 700SE Instructions rev Sept 2010 - 2010-09.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions