Penumbra, Inc

Penumbra System

Penumbra ENGINE Pump Operation Maintenance and Service Manual Sept 2019

Operation Maintenance and Service Manual

4 Pages

O P E R AT I O N , M A I N T E N A N C E , A N D SERVICE MANUAL  P e n u m b r a EN G I NE ™  R  Device Description  Specifications  The Penumbra ENGINE is an electromechanical device designed to create vacuum pressure for use with Penumbra Aspiration Systems. The Penumbra ENGINE’s accessory component is a 1,000 mL disposable ENGINE canister with a vacuum filter for fluid containment. The Penumbra Aspiration Systems include an aspiration tubing that connects the canister to the sterile field.  Table 1 – Penumbra ENGINE Specifications 100-240 VAC  Frequency  50 Hz; 60 Hz  Current  2.0 A  Fuse  Two 2A, 5 X 20 mm Operating Speed Type T (Time lag fuse) Breaking Capacity 1500A at 250VAC (T2A H 250VAC)  Port Output  5-20VDC, 3.0A  Motor and Pump Description  Oil-less, diaphragm pump  Maximum Vacuum  ≤10% of Ambient Pressure ≥26.9 inHg (91.1 kPa) at sea level  Flow Rate  0-0.8 SCFM (0-23 LPM)  Width  13 in (33 cm)  Depth  11 in (28 cm)  Height  10 in (25 cm)  Weight  15 lbs max (6.8 kg)  Sound  <60 dBa  Duty Cycle  Non-continuous duty [45 min (97.8%) ON / 1 min (2.2%) OFF]  Date of Manufacture  The date of manufacture can be identified in the unit label where the first four digits refer to the year of manufacture, the following two digits refer to the month of manufacture, and the last two digits refer to the day of manufacture.  Operating Principle  The Penumbra ENGINE is intended to generate vacuum pressure for use with Penumbra Aspiration Systems.  Indication for Use  The Penumbra ENGINE is indicated as a vacuum source for Penumbra Aspiration Systems.  Contraindications  There are no contraindications.  Warnings / Precautions  • The canister is intended for single use only. Do not reuse. Reuse may result in canister cracking or vacuum filter blockages, which may result in the inability to aspirate. • Do not block bottom air vents. Unit may overheat and shut off or fail to restart if run for extended periods of time without airflow. • To avoid the risk of electrical shock, this equipment must only be connected to a supply mains with protective earth. • Do not position the Penumbra ENGINE so that it is difficult to remove the power cord. The means of mains disconnect is to remove the power cord. • Only use replacement fuse with correct rating (see Table 1 for fuse rating). • Remove and service the Penumbra ENGINE if liquids or solids have been drawn into the Penumbra ENGINE. • Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. • Do not use in an oxygen rich environment. • To prevent fire or shock hazard, use a replacement power cord of equal rating. • Do not re-infuse blood or fluid from the canister back into the patient. • Do not use petroleum based compounds, acids, caustics, or chlorinated solvents to clean or lubricate any parts. It will reduce the service life of the Penumbra ENGINE. Use only water-based solvents for cleaning. • Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. • Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30 cm) to any part of the Penumbra ENGINE. Otherwise, this could result in degradation of the performance of this equipment. • Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the Penumbra ENGINE as they can interfere with and result in degradation of the performance of the equipment. • Equipment is not safe for MR use. • No modification of this equipment is allowed.  Compatible Accessories  The Penumbra ENGINE is compatible with the 1,000 ml disposable ENGINE canister. Note:	Plastic canisters, canister lids, and vacuum filters are Single Use Only and CANNOT be reused. The canister comes pre-assembled with a removable lid and vacuum filter. The vacuum filter is included to prevent fluid and aerosol contamination of the pump. The vacuum filter protects against pump contamination in the case of canister overflow because it prevents the overflow from reaching the pump. Table 2 – Standard Compatible Equipment and Accessories Accessories  One 1,000 ml disposable ENGINE canister with lid  Description  The ENGINE canister has a self-sealing material that acts as an overflow protection device. When the vacuum filter comes in contact with moisture, the self-sealing material stops vacuum and prevents fluids from entering the pump and damaging the system.  Set-Up  1. Place the ENGINE canister on a flat surface and check that the lid is securely attached. 2. Insert the ENGINE canister into the canister receptacle.  Operator Profile  Operators of the Penumbra ENGINE should be experienced in performing the associated surgical or interventional procedure. No specific training is required to operate the Penumbra ENGINE other than reading and understanding this manual. Installation (set-up) of the Penumbra ENGINE and Canister can be found below.  Use Environment  The Penumbra ENGINE is intended for use in operating rooms or interventional catheterization laboratories.  1 (4)  English  Voltage
File Type: PDF
File Size: 1.17 MB
File Name: Penumbra, Inc - Penumbra ENGINE Pump Operation Maintenance and Service Manual Sept 2019 - 2019-09.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions