Pilling

RETRACTOR IMA TAKEDOWN SYSTEM

IMA Retractor Instructions for Use

15 Pages

en  INSTRUMENT DESCRIPTION (ENGINEERING)  PREPARATION AT POINT OF USE  The following instructions are for the Pilling IMA Retractor (341136).  Directly after use, remove coarse contamination from the instruments and keep the instrument moist for transit to the processing site. Prior to cleaning and sterilization do not use any fixing agents or hot water (>104°F, >40°C) since this may lead to the fixation of residue and can interfere with the cleaning process.  INDICATIONS FOR USE  The Pilling IMA Retractor (341136) is a re-useable surgical instrument used to retract and hold soft tissue and connected bone during internal mammary artery surgical procedures.  TRANSPORTATION  During the transportation of the instruments to the processing site, store contaminated instruments securely in a closed container or instrument case to avoid damage to the instruments and/or contamination of the environment.  CLEANING, DISINFECTION AND DRYING INSTRUCTIONS  The Pilling IMA Retractor (341136) should be cleaned independently according to the instructions listed below.  INSTRUCTIONS FOR USE  1. Prior to placement of the retractor in the patient, join the two blades together (lightly touching) and the reinforcing T-screw (A) in fully extended position with no tilt (illustration 1).  1 A  2. After a median sternotomy, place the Pilling IMA Retractor (341136) in the patient with the lifting blade on the side of the patient to be raised for IMA takedown. 3. Turn the handle (B) to open the sternum (illustration 2).  2 A  B  C  4. When sufficiently opened, slowly turn the reinforcing screw (A) to allow the tilt of the retractor and lift of one half of the sternum to increase exposure. Do not over-tighten the reinforcing screw to avoid potential damage to the ribs. 5. After completing the IMA dissection, reverse the order of placement for removal.  Automatic Processing Instructions For Use with Alkaline or Enzymatic Detergents  Manual Processing Instructions For Use with Enzymatic Detergents  PRE-CLEANING • Soak the instrument in lukewarm tap water for a minimum time of 5 minutes. • Disassemble the instrument (if applicable) under lukewarm tap water. • Brush under lukewarm tap water with a soft brush until all visible residues are removed.  PRE-CLEANING • Soak the instrument in lukewarm tap water for a minimum time of 5 minutes. • Disassemble the instrument (if applicable) under lukewarm tap water. • Brush under lukewarm tap water with a soft-bristled brush until all visible residues are removed.  CLEANING • Place the opened instrument in a wire basket and start the cleaning process. • Pre-rinse for 2 minutes with cold water. • Empty. • Pre-rinse for 3 minutes with cold water. • Empty. • Wash for 5 minutes at 131°F (55°C) with a 0.5% alkaline detergent or at 113°F (45°C) with a 0.8% enzymatic detergent. • Empty. • Neutralize for 3 minutes with cold water. • Empty. • Rinse for 2 minutes with cold water. • Empty. Note: The preparation of concentration, temperature and application time of the cleaning agent must be according to the instructions for use provided by the detergent manufacturer. Detergents must be approved for use with metal reusable general surgical instruments. Examples of detergents used in validation studies: Enzymatic Detergent: Cidezyme/Enzol; Alkaline Detergent: Neodisher Mediclean.  CLEANING • Place the instrument in an ultrasound bath at 104°F (40°C) with a 0.5% enzymatic detergent. • Sonicate for 10 minutes (minimum). • Remove the instrument and flush with lukewarm tap water for approximately 15 seconds while simultaneously brushing with a soft-bristled brush. Note: The preparation of concentration, temperature and application time of the cleaning agent must be according to the instructions for use provided by the detergent manufacturer. Detergents must be approved for use with metal reusable general surgical instruments. Examples of detergents used in validation studies: Enzymatic Detergent: Cidezyme/Enzol.  DRYING Dry the outside of the instruments using the drying cycle of the cleaning equipment. If necessary, instruments can be dried by hand with a lint-free cloth.  DRYING Dry instruments with a lint-free cloth.  DISINFECTION Teleflex does not provide disinfection instructions due to the sterility instructions provided.  DISINFECTION Teleflex does not provide disinfection instructions due to the sterility instructions provided.
File Type: PDF
File Size: 2.32 MB
File Name: Pilling - Teleflex - L02412 - IMA Retractor Instructions for Use - 2018-12 - R01.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions