seca
seca 952 Instruction manual and guarantee Rev B Dec 2018
Instruction Manual
64 Pages

Preview
Page 1
seca 952
D
Bedienungsanleitung und Garantieerklärung
2
GB Instruction manual and guarantee F Mode d’emploi et garantie
22
I
Manuale di istruzioni e garanzia
32
E
Manual de instrucciones y garantia
42
P
Instruções de utilização e declaração de garantia
52
12
1. Signed and sealed English
With seca products, you are not only purchasing technology which has been perfected over 100 years, but also quality with official legal certification confirmed by institutions. seca products comply with European directives, standards and national laws. When you buy seca, you buy the future. Products bearing this symbol meet the applicable regulatory requirements of the European Community, especially the following:
0123
• Directive 93/42/EEC for medical devices seca’s professionalism is also recognized by official testing agencies. TÜV Süd Product Service, the appointed office for medical devices, confirms with this certificate that as a medical devices manufacturer, seca consistently complies with the strict legal requirements. seca’s quality assurance system includes the areas of design, development, production, sales and service of medical scales and length measuring systems as well as software and measuring systems for assessing state of health and nutrition. seca helps the environment. Saving natural resources is very important to us. We therefore make every effort to save on packaging materials wherever it makes sense and whatever is left over can be conveniently disposed of on site via the recycling system.
12
2. Congratulations! By purchasing the seca 952 electronic chair scale, you have acquired a highly-accurate and sturdy piece of equipment. seca has been putting its experience at the service of health for over 150 years now, and as market leader in many countries of the world, is always setting new standards with its innovative developments for weighing and measuring. In accordance with national regulations, the seca 952 wheelchair scale with standing aid is used primarily in hospitals, doctors’ surgeries and in-patient nursing facilities. The weight display can be switched between kilogrammes (kg), pounds (lb) and stones (st). Weight is determined within a few seconds.
The seca 952 can be moved on castors, and its low power consumption means that it can be used on a mobile basis with batteries for long periods. seca 952 chair scales are made for people who are not especially steady on their feet. To give you a safe feeling while weighing, the chair scale has a solid tubular frame and a firmly bolted seat. The freerunning casters make the scale very easy to move. The wheel-locking lever, together with the swiveling armrests and foot supports, makes it easier to sit in safety. The scale is of a very sturdy construction and will give you long and loyal service. It is easy to operate and the large display is easy to read.
3. Safety Before using the new scale, please take a little time to read the following safety instructions.
Warnings • Never use the seca 952 chair scale for transport purposes. Do not use seca 952 chair scale to transport people or objects. If you transport people or objects using the chair scale, there is an acute risk of injury. • Never place the seca 952 chair scale on sloping surfaces. The brakes on the casters could be released. • Prevent the scale from rolling away accidentally. Use the wheel brake when the patient is sitting down or getting up
Model 952
and assist people who are unsteady on their feet.
Notes • Follow the safety instructions in the instruction manual. • Keep the operating manual and the declaration of conformity contained therein in a safe place. • Have scale serviced on a regular basis (see “Servicing” on page 19). • Use only the type of battery stated (see “Power supply” on page 14).
GB 13
4. Before you start… Unpacking The scope of supply includes: • Chair scale comes complete assembled
• Battery holder containing 6 mignon-type AA 1.5 V batteries • 1 set of operating instructions
Power supply The scale is powered exclusively by batteries. – Open the battery compartment in the base of the display housing. – Connect the cable to the holder and batteries. – Place the holder in the battery compartment. – Close the lid of the battery compartment again.
The LC display has a low power consumption – 4000 weighing operations can be performed with one set of batteries. Once battery voltage is no longer adequate, the battery symbol first appears in the display to indicate that battery power is dropping. Once battery power is no longer sufficient, bAtt appears in the display and weighing is no longer possible.
14
5. Operation Controls and displays Controls on the display
0.0
kg
Switch scale on and off
press briefly
switch between kg, lbs and st
press briefly
start a new weighing operation without removing the load from the scale set display to zero, activate/deactivate tare function
hold down
Other controls The armrests on the chair scale can be swivelled backwards independently. This is useful because it makes it easier for the person being weighed to sit down. – Ensure that you do not trap any part of the body or pieces of clothing when folding the rests down.
Model 952
GB 15
– The rear casters can be locked if you push down the two locking levers on the casters. This device should be used when the patient is sitting down on the scale or getting up from it.
Locking lever – Once the person who is to be weighed is seated, the foot-rests are tilted downwards. The patient can now place his or her feet on the foot-rests.
Correct weighing – Press the start key with no load on the scale. se(A, 8.8.8.8.8. and 0.0 appear consecutively in the display. The scale is then automatically set to zero and ready to use. – If necessary, switch the weight display (see page 17). – Get the patient to sit on the scale. – The patient’s weight can only be determined once he or she is no longer in contact with the floor. Be sure, therefore, that the patient’s feet are on the foot rest throughout the weighing operation. – Read the weighing result off the digital display. – If a load greater than 200 kg is placed on the scale, StOP appears in the display. – To switch off the scale, press the start key again.
16
StOP
Auto-hold function The HOLD function is activated automatically at weights of over 1.5 kg. The display flashes until a stable weight has been measured. The display is then frozen until the next weighing operation. HOLD appears in the display. – To perform a new measurement without removing the load from the scale first, press the hold/tare key.
Switching the weight display The weight display can be switched between kilogrammes (kg), pounds (lb) and stones (st). – Switch on the scale using the start key. Weight is initially displayed in the last setting selected. – To switch the weight display between kilogrammes, pounds and stones, keep pressing the kg/lb/st key until the desired unit appears in the display. – The kg, lbs or sts display lights up.
0.0 0:00.0
kg
0.0
lbs
sts
Automatic switch-off/economy mode The scale switches off automatically after approx. 3 minutes if it has no load on it. If the tare or hold functions are activated, the scale switches off after approx. 2 minutes. If the scale has a load of at least 2 kg on it, it does not switch off for approx. 2 minutes.
Taring weight display (TARE) The Tare function is very useful if an additional weight (a blanket, for example) is to be ignored for weighing purposes. Proceed as follows: – Press the start key with no load on the scale. – First place the additional weight (a blanket, for example) on the scale and activate the Tare function by depressing and holding the hold/tare key.
Model 952
GB 17
The display is reset to zero. 0.0 appears in the display. The note “NET” appears. – Now put the patient and the additional weight on the scale. The scales calculate the patient’s weight without the additional weight.You can now perform as many weighing operations as you like. – Hold the key down again to deactivate the Tare function; the scale is then back in normal weighing mode and the tare value has been erased. – The tare value is likewise erased by the scale being switched off.
0.0
kg
NET
6. Cleaning Clean the seat and the housing as required using a domestic cleaning agent or commercially-available disinfectant. Follow the manufacturer’s instructions. Under no circumstances use abrasive or acid cleaners, white spirit, benzene or the like for cleaning. Such substances can damage the high-quality surfaces.
7. What do I do if… « no weight display comes on? – Is the scale switched on? – Check the batteries. « 0.0 does not appear before weighing? – Switch off the scale with the Start key and start the scale again – there must not be any load on the scale – and only its feet should be in contact with the floor. « one segment is illuminated constantly or not at all? – The relevant segment has a fault. Inform Servicing. « the display shows ? – Battery voltage is running low. Change the batteries in the next few days. « bAtt appears in the display? – Batteries are empty. Put in new batteries. « St0p appears in the display? – Maximum load has been exceeded. « the display flashes? – If you have just activated the Hold or Tare function, please wait until the scale has detected a steady weight value. The display will then stop flashing. – If there has been no activation of a function beforehand, remove the load from the scale and wait until 0.0 is displayed, then weigh again. « the display Er and a number appear (e.g. Er:12)? – Switch off the scale with the Start key and start the scale again. The scale will then
18
work normally again. If this is not the case, disconnect the power supply by briefly removing the batteries. If this measure is equally unsuccessful, inform the Service department.
8. Servicing Your seca scale leaves the factory with an accuracy greater than ±0,1 %/±100 g. To ensure that this accuracy is maintained, the product must be carefully set up and regularly maintained. Depending on the frequency of use, we recommend servicing every 3 to 5 years. Please ensure that a qualified service agent is used. If in doubt, contact seca Customer Service for further information.
9. Technical data Maximum load Minimum load Graduations Dimensions height: width: depth: Height of figures Weight Temperature range Power supply Batteries Power consumption EN 60 601-1: medical electrical equipment type B: Accuracy Functions
200 kg / 440 lbs / 31.5 st 1 kg 100 g / 0.2 lbs 920 mm 565 mm 810 mm 20 mm approx. 24.5 kg +10 °C to +40 °C batteries 6 type AA 1.5 V batteries approx. 25 mA
greater than ±0,1 %/±100 g Switch between units, NET, Auto-hold
10. Disposal Disposing of the device
Batteries
Do not dispose of the device in domestic waste. The device must be disposed of properly as electronic waste. Follow the national regulations which apply in your case. For further information, contact our service department at: service@seca.com
Do not throw used batteries away in domestic waste. Dispose of batteries at collection points in the vicinity. When buying new batteries, select those low in harmful substances and containing no mercury (Hg), cadmium (Cd) or lead (Pb).
Model 952
GB 19
11. Warranty A two-year warranty from date of delivery applies to defects attributable to poor materials or workmanship. All moveable parts - batteries, cables, mains units, rechargeable batteries etc. - are excluded. Defects which come under warranty will be made good for the customer at no charge on production of the receipt. No further claims can be entertained. The costs of transport in both directions will be borne by the customer should the equipment be located anywhere other than the customer’s premises. In the event of transport damage, claims under warranty can be
honoured only if the complete original packaging was used for any transport and the scale secured and attached in that packaging just as it was when originally packed. All the packaging should therefore be retained. A claim under warranty will not be honoured if the equipment is opened by persons not expressly authorised by seca to do so. We would ask our customers abroad to contact their local sales agent in the event of a warranty matter.
12. Declaration of conformity seca gmbh & co. kg hereby declares that the product meets the terms of the applicable European directives. The unabridged declaration of conformity can be found at: www.seca.com.
20
VHFDJPEK FRNJ +DPPHU6WHLQGDPPभ˼भ +DPEXUJՅ*HUPDQ 7HOHSKRQH )D[ LQIR#VHFDFRP
VHFDRSHUDWHVZRUOGZLGHZLWKKHDGTXDUWHUV LQ*HUPDQDQGEUDQFKHVLQ VHFDIUDQFH VHFDXQLWHGNLQJGRP VHFDQRUWKDPHULFD VHFDVFKZHL] VHFD]KRQJJXR VHFDQLKRQ VHFDPH[LFR VHFDDXVWULD VHFDSROVND VHFDPLGGOHHDVW VHFDEUDVLO VHFDVXRPL VHFDDPpULFDODWLQD VHFDDVLDSDFLILF DQGZLWKH[FOXVLYHSDUWQHUVLQ PRUHWKDQFRXQWULHV
$OOFRQWDFWGDWDXQGHUZZZVHFDFRP
17-10-06-346d_12-2018B
0HGLFDO0HDVXULQJ 6VWHPVDQG6FDOHV VLQFH