Instruction Manual
77 Pages

Preview
Page 1
seca 869
P
Bedienungsanleitung und Garantieerklärung
2
Instruction manual and guarantee
14
Mode d’emploi et garantie
26
Manuale di istruzioni e garanzia
38
Manual de instrucciones y garantia
50
Instruções de utilização e declaração de garantia
62
1. Congratulations! English
By purchasing the seca 869 electronic personal scale, you have acquired a highly-accurate and sturdy piece of equipment. seca has been putting its experience at the service of health for over 150 years now, and as market leader in many countries of the world, is always setting new standards with its innovative developments for weighing and measuring. The weight display can be switched between kilogrammes (kg), pounds (lb) and stones (st). Weight is determined within a few seconds.
In addition to the conventional determination of weight, the seca 869 also has a function for determining body mass index. For this purpose, height is entered on the keypad and the body mass index associated with the weight value is output. The scale is of a very sturdy construction and will give you long and loyal service. It is easy to operate and the large display is easy to read. Its low power consumption means that with a set of batteries, the seca 869 can be used on a mobile basis for long periods.
2. Safety Before using the new scale, please take a little time to read the following safety instructions. • Follow the safety instructions in the inplatform and the case must be laid so struction manual. that it does not present a tripping hazard. • Keep the operating manual and the declaration of conformity contained • Avoid pulling hard on the connecting therein in a safe place. cable to the display unit. • Use only the type of battery stated (see • Use the assembly material supplied. “Changing the batteries” on page 23). • When assembling, ensure that screws • When using the scale with a mains unit, are tight and that the rod has been asensure that the supply cable is routed in sembled correctly (see “Fitting the wall such a way as to exclude any type of bracket” on page 15). tripping hazard. • Have repairs carried out exclusively by • Do not drop the scale or subject it to authorised persons. violent shocks. • Have scale serviced on a regular basis • The cable between the weighing (see “Servicing” on page 22).
14
3. Before you start… Remove the packaging and place the scale on a firm, level surface. The scope of supply includes: • • • • • •
Weighing platform Display head plus connecting cable Wall bracket 2 Screws 2 Rawlplugs 6 mignon-type AA 1.6 V batteries
Desk-top stand If you prefer, you can stand the display part rather than hang it on the wall: Alter the angle of the display part to enable the display to be read most easily.
Fitting the wall bracket The display part is intended for mounting on the wall. Use the mounting material supplied to do so. – Screw the wall bracket to the wall as shown. Be aware that you have a length of only 2.25 m of cable between the scale and the display part. The cable may not contact the weighing platform during weighing, as this might falsify the result.
Model 869
15
– Push the display onto the wall bracket.
– If you want to change the location of the scale, take the display out of the wall bracket and push it into the bracket on the weighing platform to transport it.
Power supply The scale is generally powered by batteries. The LC display has a low power consumption – 10,000 weighing operations can be performed with one set of batteries. When or bAtt appear in the display, you should change the batteries. You require 6 AA-type 1.5 V batteries. – Carefully turn over the scale so that the base of the scale is accessible. – Open the cover. – Insert the new batteries in the battery compartment. Check that the polarity is correct! – Close the cover. – Then turn the scale back up the right way. Note: the scale is prepared for use with a seca mains unit which is available as an accessory.
16
Connection for mains unit
Connecting the connecting cable to the weighing platform The connecting cable of the display part is used to transmit digital data which are considerably less sensitive to interference than the otherwise conventional small analog measuring signals. Ageing and wear on the cable and on the plug contacts thus have no effect on the accuracy of the scale. To make the connection, proceed as outlined below: – Connect the cable of the display case to the socket under the carrying handle. – Then place the scale upright again. The cable may not contact the weighing platform during weighing, as this might falsify the result.
4. Setting up and aligning the scale The screwed feet can be used to level off any slight unevenness in the floor. – Place the scale on a level surface. – Align the scale by screwing the foot screws. The air bubble in the spirit level must be right in the centre of the circle. – Ensure that only the feet of the scale are in contact with the floor. The scale may not be in contact at any other point.
Model 869
spirit level
17
5. Operation Controls and displays The controls and display are in the display part.
Switch scale on and off press briefly hold down in function menu
s switch between kg and lbs s switch between lbs and sts s increase value
press briefly hold down in function menu
s activate/deactivate hold function s set display to zero, activate/deactivate tare function s decrease value
Activating the BMI function, Confirmation
Correct weighing – Press the start key with no load on the scale. se(a, 8.8.8.8.8. and 0.0 appear consecutively in the display. The scale is then automatically set to zero and ready to use. – If necessary, switch the weight display (see page 19). – Read the weighing result off the digital display. – If a load greater than 250 kg or 550 lbs is placed on the scale, St0P appears in the display. – To switch off the scale, press the start key again.
18
Switching the weight display The weight display can be switched between kilogrammes (kg) and pounds (lb) or between pounds (lb) and stones (st). – Switch on the scale using the start key. Weight is initially displayed in the last setting selected. – To switch the weight display between kilogrammes and pounds, press the kg/ lbs/sts key. – The kg or lbs display lights up. – To switch weight display between pounds and stones, hold down the kg/lbs/sts key for approx. 2 seconds. The lbs or sts display lights up.
Automatic switch-off/economy mode The scale automatically detects whether it is being operated on rechargeable/nonchargeable batteries or whether it is connected to the mains. – Operation on rechargeable/non-chargeable batteries: automatic shut-down after 20 seconds. – With mains operation: shut-down only via keypad.
Taring weight display (TARE) The tare function is very useful, for example for determining the weight of a child or an object placed on the scale in addition to yourself. Proceed as follows: – Press the start key with no load on the scale. – First stand on the scales yourself without the additional weight and activate the Tare function by depressing and holding the hold/tare key. The display is reset to zero, 0.0 flashes in the display until weight is detected to be stable. Only then is the Tare function fully activated. The note “NET” appears. – Now take the additional load onto the scale. You can leave the scale to do so, in which case ---- appears. The scale determines the weight of the additional load. You can now perform as many weighing operations as you like.
Model 869
19
– Hold the key down again to deactivate the Tare function; the scale is then back in normal weighing mode and the tare value has been erased. – The tare value is likewise erased by the scale being switched off.
Store weight value (HOLD) You can also continue displaying the weight determined once the load has been removed. This makes it possible to look after a patient first, before having to note the weight: – Press the hold/tare key whilst the load is on the scale. “HOLD” appears in the digital display. The value remains saved in the display until the hold function is automatically switched off. – The HOLD function can be switched off by pressing the hold/tare key again. 0.0 appears in the display if the scale has no load on it, otherwise the current weight. The “HOLD“ display vanishes.
Body Mass Index (BMI) Body Mass Index puts height and weight in relationship to one another, providing more accurate information than ideal Broca weight, for example. A tolerance range is given which is considered ideal for health. – Press the start key with no load on the scale. se(a, 8.8.8.8.8. and 0.0 appear consecutively in the display. The scale is then automatically set to zero and ready for operation. – Press the FUNC key. On the display, you will see the last height entered. – You can use the arrow keys to adjust the value in increments according to the graduations displayed. – Once the correct value is set, press the FUNC key again. The BMI function is now activated. – Step on the scale and keep still. – Read off the BMI on the digital display and compare it with the categories on page 21. – To return to normal weighing mode, press the FUNC key.
20
– To switch off the scale, press the Start key again.
Evaluating Body Mass Index for adults: Compare the value determined with the categories quoted below which correspond to those used by WHO, 2000. • BMI below 18.5: Warning, this patient weighs too little. There could be a tendency to anorexia. An increase in weight is recommended to improve well-being and performance. If in doubt, consult a specialist. • BMI between 18.5 and 24.9: The patient is of a normal weight. He can stay as he his. • BMI between 25 and 30 (pre-obese): The patient is slightly to moderately overweight. He should cut his weight if he is already ill (e.g. diabetes, hypertension, gout, fat metabolism disorders). • BMI over 30: Weight reduction is essential. Metabolism, cardiovascular system and bones are all under strain. A consistent diet, plenty of movement and behavioural training are all recommended. If in doubt, consult a specialist.
6. Cleaning Clean the rubber surface and the housing as required using a domestic cleaning agent or commercially-available disinfectant. Follow the manufacturer’s instructions. Under no circumstances use abrasive or acid cleaners, white spirit, benzene or the like for cleaning. Such substances can damage the high-quality surfaces and the printing.
Model 869
21
7. What do I do if… … no weight display comes on? – Is the scale switched on? – Check the batteries. – Is the plug contact for connecting the display to the scale correctly connected? – Is the plug contact of the mains unit properly connected to the scale? … 0.0 does not appear before weighing? – Switch off the scale with the Start key and start the scale again – there must not be any load on the scale – and only its feet should be in contact with the floor. … one segment is illuminated constantly or not at all? – The relevant segment has a fault. Inform Servicing. … the display shows ? – Battery voltage is running low. Change the batteries in the next few days. … batt appears in the display? – Batteries are empty. Put in new batteries. … St0p appears in the display? – Maximum load has been exceeded. … the display flashes? – If you have just activated the Hold or Tare function, please wait until the scale has detected a steady weight value. The display will then stop flashing. – If there has been no activation of a function beforehand, remove the load from the scale and wait until 0.0 is displayed, then weigh again. … the display E and XX.XX appear? – Switch off the scale with the Start key and start the scale again. The scale will then work normally again. If this is not the case, disconnect the power supply by briefly removing the batteries. If this measure is equally unsuccessful, inform the Service department.
8. Servicing Your seca scale leaves the factory with an accuracy greater than ± 0.15 %. To ensure that this accuracy is maintained, the product must be carefully set up and regularly maintained. Depending on the frequency of use, we recommend servicing every 3 to 5 years. Please ensure that a qualified service agent is used. If in doubt, contact seca Customer Service for further information.
22
Changing the batteries When or bAtt appear in the display, you should change the batteries. You need 6 type AA 1.5 V batteries. – Carefully turn over the scale so that the base of the scale is accessible. – Open the cover. – Insert the new batteries in the battery compartment. Check that the polarity is correct! – Close the cover. – Then turn the scale back up the right way.
9. Technical data Dimensions scale width: height: depth: Dimensions weighing platform width: height: depth: Height of figures Weight Temperature range Maximum load Minimum load Power supply Power consumption Batteries EN 60 601-1: Insulated equipment, Protection Class II: medical electrical equipment type B: Accuracy Graduations 0 up to 150 kg 150 kg up to 250 kg: Functions
Model 869
313 mm 58+6 mm 315 mm 205 mm 55 – 75 mm 48 – 80 mm 20 mm approx. 3.9 kg +10 °C to +40 °C 250 kg / 550 lbs / 39 sts 2 kg / 4.4 lbs Battery/ mains unit (option) approx. 30 mA 6 type AA 1.5 V batteries
greater than ± 0.15 % 100 g 200 g Switch between units, Tare, Hold Body Mass Index
23
10. Spare parts and accessories Power supply Model dependent mains unit Plug-in mains unit, Euro: 230V~ / 50Hz / 12V= / 130mA seca spare part no.: 68-32-10-252 Desk-top mains unit, switchable, Euro: 115V~ / 230V~ / 50-60Hz / 9V= / 350mA seca spare part no.: 68-32-10-243 Plug-in mains unit, USA: 120V~ / 60Hz / 12V= / 150mA seca spare part no.: 68-32-10-259 Attention! Use only seca original plug-in mains units with 9 V or controlled 12 V output voltage. Commercially-available mains units may supply a higher voltage than stated and thus lead to damage to the scale.
Accessories Carrying case 421 seca spare part no.: 421 00 00 009
11. Disposal Disposing of the device
Batteries
Do not dispose of the device in domestic waste. The device must be disposed of properly as electronic waste. Follow the national regulations which apply in your case. For further information, contact our service department at: service@seca.com
Do not throw used batteries away in domestic waste. Dispose of batteries at collection points in the vicinity. When buying new batteries, select those low in harmful substances and containing no mercury (Hg), cadmium (Cd) or lead (Pb).
24
12. Warranty A two-year warranty from date of delivery applies to defects attributable to poor materials or workmanship. All moveable parts - batteries, cables, mains units, rechargeable batteries etc. - are excluded. Defects which come under warranty will be made good for the customer at no charge on production of the receipt. No further claims can be entertained. The costs of transport in both directions will be borne by the customer should the equipment be located anywhere other than the customer’s premises. In the event of transport damage, claims under warranty can be
Model 869
honoured only if the complete original packaging was used for any transport and the merchandise secured and attached in that packaging just as it was when originally packed. All the packaging should therefore be retained. A claim under warranty will not be honoured if the equipment is opened by persons not expressly authorised by seca to do so. We would ask our customers abroad to contact their local sales agent in the event of a warranty matter.
25