SEERS MEDICAL
Medicare Multi Couch SM9xxx and SM05xx series Service Manual Issue 1
Service Manual
19 Pages
Preview
Page 1
SERVICE MANUAL SEERS Medicare Multi Couch (Single & Dual Foot Sections) Model No.’s: SM9556, SM9566, SM9576, SM9586, SM9686 SM0555, SM0565, SM0575, SM0585
DOC No. 07-005-SM
1
ISSUE 1
1. GENERAL MAINTENANCE. CONGRATULATIONS on the purchase of your SEERS MEDICAL Product. If these service instructions are adhered too, this product will provide many years of safe and reliable use. IF THESE SERVICE INSTRUCTIONS ARE NOT FOLLOWED - YOUR WARRANTY COULD BE INVALID! Always keep these Service Instructions available for reference.
WARNINGS! Warnings identify potential hazards which if not followed correctly, could result in serious injury, or possibly even death!
Ensure electric couches are not used in the presence of flammable gasses such as an anaesthetic agent. DO NOT EXCEED the Maximum Safe Working Load of 240 Kg (528 lbs) – which must be distributed evenly across the working surface Do not concentrate uneven weight on either side of the couch. When the plug is disconnected, this acts as a disconnect device. Use only accessories that have been designed or approved for use with this couch. Children must not play with the couch at any time. Adequately supervise children in the proximity of the couch.
CAUTIONS! Cautions identify circumstances which if not followed correctly, could result in failure or damage of the equipment!
SEERS MEDICARE MULTI COUCH –SERVICE INSTRUCTIONS PAGES
PAGES
PAGES
ALL
ALL
ALL
DOC No. 07-005-SM
2
ISSUE 1
2. CLEANING INSTRUCTIONS
WARNING! Disconnect the couch from the mains power supply prior to carrying out any cleaning or decontaminating. DO NOT SATURATE PRODUCT IF PRODUCT GETS SATURATED DURING CLEANING, THIS COULD ACCELERATE CORROSION, REDUCING PRODUCTS LENGTH OF SERVICE.
General Cleaning: To get rid of any dust or marks on the surface Vinyl MUST be wiped DAILY with a moist soft cotton cloth. Visible and loose dirt can be picked up with a vacuum cleaner (Do not use a brush type vacuum) Use a soapy cotton cloth and gently rub stains with circular movements. For more stubborn marks a dilute bleach solution can be used 5% Bleach to 95% Water.
Stain Removal: Blot excess liquid as quickly as possible with a clean 100% cotton white absorbent cloth or sponge. If necessary use clean warm water. Clean the entire area where the spot occurred on the cushion, arm etc. Water may dissolve dirt particles and make cleaning easier. Spills that are still moist are the easiest to remove. Leave to air dry naturally, do not use a hair dryer etc to speed up the drying.
Coffee, tea etc spills: Use an absorbent white cloth or piece of paper. DO NOT RUB. Allow the stain to be absorbed and removed from the material surface. Then rub gently with white tissue paper in circular movements to remove any remaining dampness and residue.
Ink, Ball point pen, Denim, hard stains: Rub the stain by means of gentle circular movements with tissue dampened with 96°alcohol and water (1:1) After this rub the surface with gentle circular movement with tissue paper to dry it.
Butter, oil, grease stains: Wipe excess butter, oil or grease off the surface with a clean 100% Cotton white dry cloth. Use a soapy cotton cloth and gently rub the stain with circular movements. Use a clean damp cloth to wipe the area and dry the surface.
DOC No. 07-005-SM
3
ISSUE 1
Chewing gum: Place ice cubes in a plastic bag and apply on the chewing gum. Wait several minutes, lift the ice bag and remove the chewing gum.
DO NOT USE CHEMICALS, SADDLE SOAP, CLEANING SOLVENTS, FURNITURE POLISH, OILS, VARNISH, ABRASIVE CLEANERS OR AMMONIA IN WATER. Frequency of routine couch cleaning will depend on exact application. Frequency of routine couch cleaning will depend on exact application. 1.
Ensure the couch is in a suitable area for cleaning.
2.
The couch must be OFF of the wheels.
3.
Disconnect from mains power supply if electric model.
4.
Control handsets can be wiped over using an alcohol wipe.
5.
Prepare a solution of warm water and a neutral detergent.
6.
DO NOT SATURATE PRODUCT – This should be a wipe down – not a soaking!
7.
Start by cleaning the top surface of the couch, working down onto the frames below, ensuring to not accidentally activate any of the release levers, or user interface parts.
8.
Ensure the couch is dry before re-use.
9.
Safely discard of cleaning materials.
10.
Wash hands thoroughly.
If DECONTAMINATING the couch then repeat steps above using a dilute Hypochlorite & warm water mixture (mixed at 10,000ppm) instead of warm water and soap.
DOC No. 07-005-SM
4
ISSUE 1
3. MAINTENANCE
WARNING! Disconnect the couch from the mains power supply prior to carrying out any maintenance. All electrical maintenance should be performed by a suitably qualified person. BLUE or BROWN wires must not be connected to any earth terminal. 1.
A visual inspection should be carried out daily prior to use.
2.
Regular servicing should be carried out a minimum of every six months or more frequently if the couch is in constant use.
3.
Routine servicing or repair must only be performed by suitably qualified people.
4.
Look for any visual signs of damage. Ensure all nuts, bolts and other fasteners are present and fitted where expected. If loose (can be undone by hand), re- tighten using suitable tools – but taking care to not over tighten as this could cause binding, juddering, identifiable by a likely noise.
5.
Upholstery fixings should be checked regularly and tightened if loose. DO NOT USE PRODUCT IF ANY UPHOLSTERY FIXING SCREWS ARE MISSING!
6.
Check hinge pins are secured correctly by the e clips. IF THESE ARE MISSING DO NOT USE COUCH!
7.
Check gas struts operate smoothly and correctly throughout all ranges of movement. The upholstered section should lock once the release lever is no longer operated.
8.
Check hydraulic pump (hydraulic variant only) for smooth operation and any signs of leakage.
ELECTRIC MODELS ONLY 9.
On electric models ,check the power cable and air pipes on hand and foot switch controls, looking for any cuts, abrasions or any other deterioration that may have occurred and replace if necessary.
10.
Ensure that the mains power supply plug is attached securely to the motor.
11.
Check mains plug connections are tight and the correct fuse is fitted.
DOC No. 07-005-SM
5
ISSUE 1
DOC No. 07-005-SM
6
ISSUE 1
DOC No. 07-005-SM
7
ISSUE 1
DOC No. 07-005-SM
8
ISSUE 1
DOC No. 07-005-SM
9
ISSUE 1
PROJECTION
WELD DEFORMITY Dimensions that are boxed denotes must be inspected after welding.
WELD TOLERANCE NOTE! All Welds to be 6mm Fillets unless otherwise stated.
DIMENSIONS Dimensions are in Millimetres (mm)
MATERIAL SEAMS Seams of materials to be on inside or underside whenever possible.
TOLERANCES Unless stated otherwise are +0.1 DIMENSIONAL +0.5 HOLE DIA. -0.0 -0.5
REVISION HISTORY DESCRIPTION DATE
REV 1
APPROVED
13
12
15
17
1
14
8 4
3 2
16 10
PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 08F-3003-ZZ Universal Chair Top Frame Link Bar 2 2 06B-0660-SF M6x60 Hex Head Set Screw - BZP 3 6 06W-0600-SF M6 Form B Washer - BZP 4 2 06N-0600-SF M6 Nylock 'T' Type Nut - BZP 5 2 06C-0006-SF M6 NUT CAP 1 06P-0003-ZP Trunnion 6 7 2 06F-0016-SF 16mm Capped Starlock - Zinc 8 2 06C-0308-SF 3/8" Rubber Ferrule 9 1 06B-1265-SF M12 x 65 Hex Head Bolt 8.8 BZP 1 06W-1200-SF M12 'B' TYPE FLAT WASHER BZP 10 11 1 06N-1200-SF M12 Type 'T' Nyloc Nut 1 06C-0012-SF M12 NUT CAP - Grey 12 1 08F-1057-ZZ Therapy Drop End Hing Pin (472) 13 14 2 06F-0007-SF 0070 DIN 6799 E Clip 7mm 15 4 06B-1030-SF M10 x 30 Long Hex Bolt - BZP 16 4 06N-1000-SF M10 NYLOC NUT - BZP 17 4 06W-1000-SF M10 'B' TYPE FLAT WASHER BZP 1 06G-0150-SF 150N Gas Strut - 95mm Stroke - Anti Trap 18 4 06B-0620-SF M6 x 20 Pan Head Pozi Drive Screw 19 20 1 08F-1051-ZZ Therapy Drop End Couch Foot Frame 21 1 08F-1052-ZZ Therapy Drop End Foot Frame Release Lever 22 3 06W-1810-SF Nylon Spacer 18x12.8x10
20
3
5
7
9
22
11
19
21
6
2
18
Material:-
Finish:Kenton Road, Debenham Suffolk, UK, IP14 6LA T: +44 (0)1728 861590 F: +44 (0)1728 861868 E: [email protected] W: www.seersmedical.com
SEERS Medical Ltd 2012
Title
Single Leg Rest Assembly
FOR EXPLANATION OF DIMENSIONS, TOLERANCES AND NOTES, REFER TO BS 8888:2000 ENSURE SHARP EDGES ARE REMOVED
Designed by
Drawing No.
Scale
nigel.hodder 02-1068-AI
Date
15/09/2014 Edition
1
Sheet
1/1
PROJECTION
WELD DEFORMITY Dimensions that are boxed denotes must be inspected after welding.
WELD TOLERANCE NOTE! All Welds to be 6mm Fillets unless otherwise stated.
DIMENSIONS Dimensions are in Millimetres (mm)
MATERIAL SEAMS Seams of materials to be on inside or underside whenever possible.
TOLERANCES Unless stated otherwise are +0.1 DIMENSIONAL +0.5 HOLE DIA. -0.0 -0.5
REVISION HISTORY DESCRIPTION DATE
REV 1
APPROVED
25
3 20
9 26 PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 08F-3003-ZZ Universal Chair Top Frame Link Bar 1 08-3004-ZZ 2 Single Leg Section - LH 1 08F-3005-ZZ Single Leg Section - RH 3 4 1 08F-3023-ZZ New Podiatry Leg Release Lever R/H 5 1 08F-3024-ZZ New Podiatry Leg Release Lever L/H 6 2 08T-3004-ZZ New Podiatry Release Lever Pivot Pin. 7 4 06S-1008-SF 10mm External Circlip 8 2 06B-0660-SF M6x60 Hex Head Set Screw - BZP 9 10 06W-0600-SF M6 Form B Washer - BZP 10 2 06N-0600-SF M6 Nylock 'T' Type Nut - BZP 11 2 06C-0006-SF M6 NUT CAP 12 2 06P-0003-ZP Trunnion 13 4 06F-0016-SF 16mm Capped Starlock - Zinc 14 2 06C-0308-SF 3/8" Rubber Ferrule 15 2 06B-1265-SF M12 x 65 Hex Head Bolt 8.8 BZP 16 2 06W-1200-SF M12 'B' TYPE FLAT WASHER BZP 17 2 06N-1200-SF M12 Type 'T' Nyloc Nut 18 2 06C-0012-SF M12 NUT CAP - Grey 19 1 08F-1057-ZZ Therapy Drop End Hing Pin (472) 20 2 06F-0007-SF 0070 DIN 6799 E Clip 7mm 4 06B-1030-SF M10 x 30 Long Hex Bolt - BZP 21 4 06N-1000-SF M10 NYLOC NUT - BZP 22 4 06W-1000-SF M10 'B' TYPE FLAT WASHER BZP 23 24 2 06G-0150-SF 150N Gas Strut - 95mm Stroke - Anti Trap 25 8 06W-6289-SF Instalation Washer 018060200001 26 8 06B-0620-SF M6 x 20 Pan Head Pozi Drive Screw
3 18
15
19 21 13
17 16 1 23
2
5
22
15
10
24 7
6
14
12
11
9
Designed by
4
8
Checked by
Date Scale
Approved by
nigel.hodder Kenton Road, Debenham, Suffolk, UK FOR EXPLANATION OF DIMENSIONS, TOLERANCES T: +44 (0)1728 861590 AND NOTES, REFER TO BS 8888:2000 F: +44 (0)1728 861868 E: [email protected] W: www.seersmedical.com
SEERS Medical Ltd 2011
ENSURE SHARP EDGES ARE REMOVED
Date
14/09/2014 Title
Dual Footrest Assembly Drawing No.
02-1069-AI
Edition
Sheet
1
1/1
DOC No. 07-005-SM
10
ISSUE 1
DOC No. 07-005-SM
11
ISSUE 1
DOC No. 07-005-SM
12
ISSUE 1
DOC No. 07-005-SM
13
ISSUE 1
DOC No. 07-005-SM
14
ISSUE 1
DOC No. 07-005-SM
15
ISSUE 1
DOC No. 07-005-SM
16
ISSUE 1
SEERS MEDICAL Limited Kenton Road Debenham Suffolk IP14 6LA t: +44 (0)1728 861590 f: +44 (0)1728 861868 e: [email protected] w: www.seersmedical.com © SEERS MEDICAL Limited
The
mark on this product demonstrates conformity with the Medical Device Directive 93/42/EEC.
DOC No. 07-005-SM
17
ISSUE 1