OPERATING INSTRUCTIONS SEERS Medicare Gynaecology Couch Model No.’s: SM8553, SM8563, SM8573, SM8583, SM8583D, SM8593D
INDEX
1. GENERAL INFORMATION – WARNINGS & CAUTIONS 2. HOW TO USE – a. WHEEL SYSTEM b. ADJUSTABLE FOOT c. ADJUSTING THE HEIGHT OF THE COUCH d. ALTERING THE BACKREST ANGLE e. APPLYING TILT (models SM8583 & SM8583D) f. OPTIONAL ACCESSORY – DOUBLE OR TRIPLE FOOTSWITCH CONTROL g. LEG SUPPORTS h. ARM LOOPS i. DEBRIS TRAY j. FOLD DOWN LEG EXTENSION k. REMOVABLE LEG EXTENSION
3. CLEANING INSTRUCTIONS 4. MAINTENANCE 5. WARRANTY 6. TECHNICAL DATA
SEERS MEDICARE GYNAECOLOGY COUCH OPERATING INSTRUCTIONS PAGES
ISSUE
DATE
ALL
3.0
17/10/2012
DOC No. 03-016-UM
2
ISSUE 3
1. GENERAL INFORMATION. CONGRATULATIONS on the purchase of your SEERS MEDICAL Product. If these operating instructions are adhered too, this product will provide many years of safe use. IF THESE OPERATING INSTRUCTIONS ARE NOT FOLLOWED - YOUR WARRANTY COULD BE INVALID! Always keep these Operating Instructions available for reference. ALL User Interfaces are identified by the DARK GREY COLOUR.
WARNINGS! Warnings identify potential hazards which if not followed correctly, could result in serious injury, or possibly even death!
Ensure electric couches are not used in the presence of flammable gasses such as an anaesthetic agent. DO NOT EXCEED the Maximum Safe Working Load of 240 Kg (528 lbs) – which must be distributed evenly across the working surface Do not concentrate uneven weight on either side, or either end of the couch. When the plug is disconnected, this acts as a disconnect device. Use only accessories that have been designed or approved for use with this couch. Children must not play with the couch at any time. Adequately supervise children in the proximity of the couch.
CAUTIONS! Cautions identify circumstances which if not followed correctly, could result in failure or damage of the equipment!
Attention refer to these Operating Instructions for further information
DOC No. 03-016-UM
3
ISSUE 3
2. HOW TO USE. a.
WHEEL SYSTEM
Lever Down = Wheels activated and ON
Lever Up = Wheels retracted and OFF
WARNING! This Couch is not designed for patient transportation Ensure Wheels are retracted prior to patient transfer or treatment. Disconnect the electric lead prior to re-locating the couch, ensuring the lead is not trapped in the mechanism.
b.
ADJUSTABLE FOOT CAUTION! Ensure Wheels are retracted before adjusting the adjustable foot.
DOC No. 03-016-UM
1.
Ensure the couch is off of the wheels
2.
Adjust the foot by turning clockwise or anticlockwise until the couch is stable.
3.
Secure the foot by tightening the nut until it locks against the threaded cap. 4
ISSUE 3
c.
ADJUSTING THE HEIGHT OF THE COUCH
Hydraulic Elevation (models SM8553) 1.
To elevate the couch, push the pedal downwards with your foot. Repeat until correct height is achieved.
2.
To lower couch, raise the pedal upwards, by putting your toe underneath the lever, lifting the lever upwards.
Electric Elevation (models SM8563)
1W
1 Way Hand Switch
DOC No. 03-016-UM
1 Way Foot Switch
5
ISSUE 3
ADJUSTING THE HEIGHT OF THE COUCH (models SM8573, SM8583 & SM8583D) To adjust the height of the couch, simply press the raise or lower button of the top button indicated by the symbol, until desired height is achieved. Once the button is released the couch height is locked in that position ready for use.
d.
ALTERING THE BACKREST OF THE COUCH (models SM8573, SM8583 & SM8583D) To adjust the backrest, simply press the raise or lower button of the middle button indicated by the symbol, until desired angle is achieved. Once the button is released the backrest is locked in that position ready for use.
ALTERING THE BACK REST ANGLE (models SM8553 & SM8563) 1.
2. 3.
4. DOC No. 03-016-UM
6
To raise the backrest, simply grasp the release lever towards the upholstery and adjust the backrest to the angle desired. Releasing the lever automatically locks the section at that angle. To lower, grasp the lever again, and lower the backrest to the required angle. Releasing the lever automatically locks the section. ISSUE 3
e.
APPLYING TILT TO THE COUCH (models SM8583 & SM8583D)
To apply tilt to the couch, simply press the raise or lower button of the bottom button indicated by the tilt symbol, until desired angle is achieved. Once the button is released the tilt angle is locked in that position ready for use.
f.
OPTIONAL ACCESSORY – DOUBLE OR TRIPLE FOOTSWITCH CONTROL (models SM8573, SM8583 & SM8583D)
To adjust couch, press the relevant button to adjust height, tilt or backrest angle up or down.
g.
LEG SUPPORTS 1
1. 2.
A 3. 4.
B
5.
To adjust the angle of the leg support, loosen locking knob on underside (A) and adjust support to desired position. Re-tighten locking knob to secure. To adjust height of the leg support, loosen locking knob on underside (B) and adjust support to desired height Re-tighten locking knob to secure. To adjust the leg support length position, loosen the locking knob on underside of main frame (not shown) and slide the chrome slider in or out of box section to desired position. Re-tighten locking knob to secure.
CAUTION! Ensure ALL Locking Knobs are secure and tightened fully, prior to commencing treatment DOC No. 03-016-UM
7
ISSUE 3
H.
ARM LOOPS 1. Locate Arm Loop into Holder Bracket on side of couch, and secure with indexed lever. 2. To gain more movement on the lever, depress button in centre of the lever, and pull out lever and move lever to opposite direction. 3. Release button, and then repeat tightening or loosening procedure.
I.
DEBRIS TRAY 1.
j.
FOLD DOWN LEG EXTENSION
1.
Grasp leg extension and rotate through 90 degrees.
2.
To insert or remove the Debris tray simply slide in or out of holder brackets.
Raise leg extension until horizontal.
3.
Slide ball knob full length of slot to engage support bar into socket, on BOTH sides on the underside of the leg extension
CAUTION! The Fold Down Leg Extension is NOT designed to be used as a seat. Patient weight should not be concentrated on the end of the couch. The Leg Extension is to support lower limbs during supine or prone treatments when a full length couch is required DOC No. 03-016-UM
8
ISSUE 3
k.
REMOVABLE LEG EXTENSION 1.
The Leg Extension is to support lower limbs during supine or prone treatments when a full length couch is required
2. To use the extension, simply engage the extension into the receiving brackets and secure by tightening the locking lever on the underside.
CAUTION! The Removable Leg Extension is not designed to be used as a seat. Patient weight should not be concentrated on the end of the couch The Leg Extension is to support lower limbs during supine or prone treatments when a full length couch is required
DOC No. 03-016-UM
9
ISSUE 3
3.
CLEANING INSTRUCTIONS
General Cleaning: To get rid of any dust or marks on the surface the Faux Leather MUST be wiped DAILY with a moist soft cotton cloth. Visible and loose dirt can be picked up with a vacuum cleaner (Do not use a brush type vacuum) Use a soapy cotton cloth and gently rub stains with circular movements. For more stubborn marks a dilute bleach solution can be used 5% Bleach to 95% Water. Stain Removal: Blot excess liquid as quickly as possible with a clean 100% cotton white absorbent cloth or sponge. If necessary use clean warm water. Clean the entire area where the spot occurred on the cushion, arm etc. Water may dissolve dirt particles and make cleaning easier. Spills that are still moist are the easiest to remove. Leave to air dry naturally, do not use a hair dryer etc to speed up the drying. Coffee, tea etc spills: Use an absorbent white cloth or piece of paper. DO NOT RUB. Allow the stain to be absorbed and removed from the material surface. Then rub gently with white tissue paper in circular movements to remove any remaining dampness and residue. Ink, Ball point pen, Denim, hard stains: Rub the stain by means of gentle circular movements with tissue dampened with 96°alcohol and water (1:1) After this rub the surface with gentle circular movement with tissue paper to dry it. Butter, oil, grease stains: Wipe excess butter, oil or grease off the surface with a clean 100% Cotton white dry cloth. Use a soapy cotton cloth and gently rub the stain with circular movements. Use a clean damp cloth to wipe the area and dry the surface. Chewing gum: Place ice cubes in a plastic bag and apply on the chewing gum. Wait several minutes, lift the ice bag and remove the chewing gum. DO NOT USE CHEMICALS, SADDLE SOAP, CLEANING SOLVENTS, FURNITURE POLISH, OILS, VARNISH, ABRASIVE CLEANERS OR AMMONIA IN WATER. Frequency of routine couch cleaning will depend on exact application. 1. Ensure the couch is in a suitable area for cleaning. 2. The couch must be OFF of the wheels. 3. Disconnect from mains power supply if electric model. 4. Control handsets can be wiped over using an alcohol wipe. 5. Prepare a solution from the guidelines detailed above. DOC No. 03-016-UM
10
ISSUE 3
6. DO NOT SATURATE PRODUCT – This should be a wipe down – not a soaking! 7. Start by cleaning the top surface of the couch, working down onto the frames below, ensuring to not accidentally activate any of the release levers, or user interface parts. 8. Ensure the couch is dry before re-use. 9. Safely discard of cleaning materials. 10. Wash hands thoroughly. If DECONTAMINATING the couch then repeat steps above using a dilute Hypochlorite & warm water mixture (mixed at 10,000ppm) instead of warm water and soap. It is crucial that any staining is treated as soon as possible but never later than 24 hours. Delays in cleaning will give stains time to react with the plasticiser in the faux leather making it more and more difficult to remove.
Note: These are recommended or suggested methods of cleaning. The manufacturer is not responsible for damage incurred while cleaning. Always try the cleaning method in a hidden area first to see the results. Remember if you are not sure contact you customer representative before proceeding.
DOC No. 03-016-UM
11
ISSUE 3
4. MAINTENANCE
WARNING! Disconnect the couch from the mains power supply prior to carrying out any maintenance. All electrical maintenance should be performed by a suitably qualified person. BLUE or BROWN wires must not be connected to any earth terminal.
1.
A visual inspection should be carried out daily prior to use.
2.
Regular servicing should be carried out a minimum of every six months or more frequently if the couch is in constant use.
3.
Routine servicing or repair must only be performed by suitably qualified people.
4.
Look for any visual signs of damage. Ensure all nuts, bolts and other fasteners are present and fitted where expected. If loose (can be undone by hand), re- tighten using suitable tools – but taking care to not over tighten as this could cause binding, juddering, identifiable by a likely noise.
5.
Upholstery fixings should be checked regularly and tightened if loose. DO NOT USE PRODUCT IF ANY UPHOLSTERY FIXING SCREWS ARE MISSING!
6.
Check hinge pins are secured correctly by the e clips. IF THESE ARE MISSING DO NOT USE COUCH!
7.
Check gas struts operate smoothly and correctly throughout all ranges of movement. The upholstered section should lock once the release lever is no longer operated.
8.
Check hydraulic pump (hydraulic variant only) for smooth operation and any signs of leakage.
ELECTRIC MODELS ONLY 9.
On electric models, check the power cable and air pipes on hand and foot switch controls, looking for any cuts, abrasions or any other deterioration that may have occurred and replace if necessary.
10.
Ensure that the mains power supply plug is attached securely to the motor/control box
11.
Check mains plug connections are tight and the correct fuse is fitted. DOC No. 03-016-UM
12
ISSUE 3
5. WARRANTY SEERS MEDICAL Limited standard terms and conditions apply to this device. A copy of this is available upon request. This contains full details of warranty terms and does not affect your statutory rights. For any further information on this product, regarding spares, warranty, service or maintenance information, please contact:
SEERS MEDICAL Limited Kenton Road Debenham Suffolk IP14 6LA T: +44 (0)1728 861590 F: +44 (0)1728 861868 E: [email protected] W: www.seersmedical.com © SEERS MEDICAL Limited
Manufactured in the UK by SEERS MEDICAL Limited. As part of our ongoing development programme SEERS MEDICAL Limited reserves the right to modify specifications and materials of this couch without prior notice.
DOC No. 03-016-UM
13
ISSUE 3
6. TECHNICAL DATA - MEDICARE GYNAECOLOGY COUCH Index
Elevation Control
SM8553
SM8563
SM9573
SM8583, SM8583D
Hydraulic
Electric
Electric + Electric Backrest
Electric, + Electric Tilt, + Electric Backrest
Overall Length (cm)
145cm with out extension, 176cm with extension.
Mid Section Length (cm)
54
Backrest Length (cm)
88
Extension Length (cm)
31
Width (cm)
65
Minimum Height (cm)
49
Maximum Height (cm)
104
Electrical Data SM8563 SM9573
SM8583, SM8583D
230 v
100-120v
230 v
100-120v
230 v
100-120v
220-240v
100-120v
220-240v
100-120v
220-240v
100-120v
Current
24v
24V
24v
24V
24v
24V
Power
600ma
1300mA
600ma
1300mA
600ma
1300mA
Mains Plug Fuse Rt (UK)
5.0A x 1
-
5.0A x 1
-
5.0A x 1
-
SM8553
Actuator / Control Box
IEC 601-1 Classification Class Class 1
Class 1
Class 1
Double Insulated Type B Equipment
DOC No. 03-016-UM
14
ISSUE 3
SEERS MEDICAL Limited Kenton Road Debenham Suffolk IP14 6LA t: +44 (0)1728 861590 f: +44 (0)1728 861868 e: [email protected] w: www.seersmedical.com © SEERS MEDICAL Limited
The
mark on this product demonstrates conformity with the Medical Device Directive 93/42/EEC. DOC No. 03-016-UM
15
ISSUE 3