Siemens Healthcare Diagnostics Inc.

Analyzers

Dimension ENZ I Calibrator Instrcuions for Use DXDCM

Instruction Manual

2 Pages

DC35  DC35  DC35  DC35  Dimension® clinical chemistry system  Dimension® clinical chemistry system  Dimension® clinical chemistry system  Dimension® clinical chemistry system  ENZ I CAL  ENZ I CAL  ENZ I CAL  ENZ I CAL  LOT  2010-03-01  Assigned Values/Sollwert/Valeurs Attribuées/Valori Assegnati/Valores Asignados  LEVEL 1a  LEVEL 2  LEVEL 3  Units/Einheiten/ Unités/Unità/ Unidades  LDI  539  1066  U/L  LEVEL 1a  LEVEL 2  LEVEL 3  SI*  0.00  9.00  17.80  µkat/L  0  Intended Use The ENZ I CAL is an in vitro diagnostic product for the calibration of the lactate dehydrogenase (LDI) method on the Dimension® clinical chemistry system. Reagents Contents: 4 vials: (2 vials Calibrator Level 2, 1.5 mL per vial) (2 vials Calibrator Level 3, 1.5 mL per vial)  Do not reuse / Nicht zur Wiederverwendung / Ne pas réutiliser / Non riutilizzare / No reutilizar  EXP CCYY-MM-DD  LDI  Enzyme I Calibrator  Symbols Key Symbolschlüssel Explication des Symboles Interpretazione simboli Clave de los Símbolos  9GD056  ENZ I CAL is a liquid bovine serum albumin based product containing lactate dehydrogenase (chicken heart).  Use By / Verwendbar bis / Utiliser jusque / Utilizzare entro / Fecha de caducidad  Note: Level 1 calibrator for LDI is not included in the ENZ I CAL carton. Purified Water Diluent (Cat. No. 710615901) or Reagent grade water is required for use as Calibrator Level 1 for the LDI method.  Batch Code / Chargenbezeichnung / Code du lot / Codice del lotto / Código de lote Catalogue Number / Bestellnummer / Référence du catalogue / Numero di catalogo / Número de catálogo  a. Purified Water Diluent (Cat. No. 710615901) or Reagent grade water a. Verdünnungsmittel Reinstwasser (Art.-Nr. 710615901) oder Wasser in Reagenzqualität a. Diluant eau purifiée (n° de réf. 710615901) ou eau de qualité réactif a. Diluente in acqua purificata (Num. cat. 710615901) o acqua di grado reagente a. Diluyente Agua Purificada (ref. 710615901) o agua de grado reactivo  Caution, consult accompanying documents / Achtung, Begleitdokumente beachten / Attention voir notice d’instructions / Attenzione, vedere le istruzioni per l'uso / Atención, ver instrucciones de uso  *Système International d’Unités (Units x F = SI)  Authorized Representative in the European Community / Bevollmächtigter in der Europäischen Gemeinschaft / Mandataire dans la Communauté européenne / Mandatario nella Comunità Europea / Representante autorizado en la Comunidad Europea  Assigned Constituent Values: Refer to the enclosed Table of Assigned Values. Traceability  LDI  IFCC LD at 37 °C primary reference method  Risk and Safety Safety data sheets (MSDS/SDS) available on www.siemens.com/diagnostics  Manufacturer / Hersteller / Fabricant / Fabbricante / Fabricante  IVD  Constituent  Precautions: For in vitro diagnostic use Materials Provided: ENZ I CAL Cat. No. DC35 Materials Required But Not Provided: Purified Water Diluent (Cat. No. 710615901) or Reagent grade water.  Contains sufficient for <n> tests / Inhalt ausreichend für <n> Tests / Contenu suffisant pour “n” tests / Contenuto sufficiente per “n” saggi / Contenido suficiente para <n> ensayos  Reagent Preparation: ENZ I CAL is ready for use. No preparation is required.  In Vitro Diagnostic Medical Device / In-Vitro-Diagnostikum / Dispositif médical de diagnostic in vitro / Dispositivo medico-diagnostico in vitro / Producto sanitario para diagnóstico in vitro  Stability Unopened Product: See Expiration Date.  Store at: 2 – 8 °C  Opened Product: Once cap is removed, assigned values are stable for 30 days when recapped immediately after use and stored at 2 – 8 °C.  Temperature Limitation / Temperaturbegrenzung / Limites de température / Limiti di temperatura / Límite de temperatura  Calibration Procedure Refer to the Calibration and Quality Control section in the Operator’s Guide for the Dimension® clinical chemistry system.  Consult Instructions for Use / Gebrauchsanweisung beachten / Consulter les instructions d’utilisation / Consultare le istruzioni per l’uso / Consulte las instrucciones de uso  Symbols Key: See adjacent panel.  Non-sterile / Nicht steril / Non stérile / Non sterile / No estéril  Dimension® is a trademark of Siemens Healthcare Diagnostics Inc. ©2008 Siemens Healthcare Diagnostics Inc. All rights reserved.  CE Mark / CE Zeichen / Marquage CE / Marchio CE / Marca CE Contents / Inhalt / Contenu / Contenuto / Contenido Reconstitution Volume / Rekonstitutionsvolumen / Volume de reconstitution / Volume di ricostituzione / Volumen de reconstitución Level / Konzentration / Niveau / Livello / Nivel 2006-06_EFIGS  Siemens Healthcare Diagnostics Ltd. Sir William Siemens Sq. Frimley, Camberley, UK GU16 8QD  Siemens Healthcare Diagnostics Inc. Newark, DE 19714, U.S.A. www.siemens.com/diagnostics  Siemens Healthcare Diagnostics Ltd. Sir William Siemens Sq. Frimley, Camberley, UK GU16 8QD  Siemens Healthcare Diagnostics Inc. Newark, DE 19714, U.S.A. www.siemens.com/diagnostics  Siemens Healthcare Diagnostics Ltd. Sir William Siemens Sq. Frimley, Camberley, UK GU16 8QD  2008-08 A PN 792035.002-US  Siemens Healthcare Diagnostics Inc. Newark, DE 19714, U.S.A. www.siemens.com/diagnostics  2008-08 A PN 792035.002  Siemens Healthcare Diagnostics Ltd. Sir William Siemens Sq. Frimley, Camberley, UK GU16 8QD  2008-08 A PN 792035.002  Siemens Healthcare Diagnostics Inc. Newark, DE 19714, U.S.A. www.siemens.com/diagnostics  2008-08 A PN 792035.002  2009-08-10
File Type: PDF
File Size: 103 KB
File Name: Siemens Healthcare Diagnostics Inc. - Dimension ENZ I Calibrator Instrcuions for Use DXDCM.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions