Signature Orthopaedics

Fixation pin

Consolidated Spine Instructions for Use

2 Pages

and superior surfaces, or incorporate screws to resist expulsion of the cage from the disc space. Signature Orthopaedics' Interbody Fusion Cages are manufactured from implant grade Polyether ether ketone (PEEK) in accordance with ASTM F2026, PEEK Optima HA enhanced (POHAe) in accordance with ASTM F2026 or implant grade titanium alloy per ISO 5832-3. Supplementary screws (if applicable) are manufactured from implant grade titanium alloy per ISO 5832-3.  Spinal Implant Product Range Fa c e t Fu si on C ag es I n ter bo dy Fu s io n Ca g e s Pe d ic le S c re w Sys te ms A nt er i or S p in a l F ix at io n P l at es Instructions for Use 131-111-001 Rev. X Caution:  Issue Date: APR-2022  Carefully read all the instructions and be familiar with the surgical technique(s) prior to use of the system. This product must only be used by trained, qualified persons, aware of the directions for use. 1 General Instructions The Signature Orthopaedics' range of spinal implants are intended to immobilize and stabilize adjacent spinal segments to allow fusion in the cervical, thoracic, lumbar and/or sacral spine. Prior to undertaking the procedure, patients must be evaluated according to the indications and contraindications of the particular system, as well as the patient selection criteria included in this document. Patients must also be informed of the precautions and possible adverse effects of the procedure, and of appropriate postoperative recovery procedures. The surgeon must be thoroughly knowledgeable not only in the medical and surgical aspects of surgical implants, but must also be aware of the mechanical limitations of the implants. See the surgical technique manuals for each device as required. The device is not intended to support in-vivo loading indefinitely. Signature Orthopaedics implants and instruments should only be used with approved devices and accessories. 2 Facet Fusion Cages Signature Orthopaedics’ Facet Fusion Cage is an implant used to stabilise the triple joint complex in the thoracolumbar spine during the development of facet joint arthrodesis. The device is intended to be implanted by a posterior approach using the corresponding instrument set. Signature Orthopaedics’ Facet Fusion Cages has been designed to be used in pairs at each level of the spine to be fused. The cage consists of a tapered and hollowed cylindrical titanium cage that is threaded and grit blasted to promote stability. The cage is hollow through the center and has windows cut into the side to allow the loading and passage of bone graft to promote fusion. The cage is manufactured from implant grade titanium alloy in accordance with ISO 5832-3. Signature Orthopaedics’ Facet Fusion Cage is to be used with complimentary posterior support in the form of pedicle screws and rods and/or an anterior weight bearing structure to share loading prior to bony fusion. The cage is intended to be used with graft materials and/or BMP, or similar. Signature Orthopaedics’ Facet Fusion Cages are indicated for use with both open and minimally invasive techniques (MIS). 3 Interbody Fusion Cages Signature Orthopaedics’ Interbody Fusion Cages are used to restore disc height and support loading during intervertebral body fusion. The devices are intended to be implanted by a posterior, anterior, lateral, or other approach, as specified in the device's surgical technique, using the corresponding instrument set. Signature Orthopaedics' Interbody Fusion Cages are rectangular or pill-shaped in geometry, with a hollow center to accept bone graft to promote arthrodesis, and may be wedged to restore the patient's lordosis or kyphosis. The cage may have holes to allow the flow of bone graft into or out of the cage's hollow center. The cage may have a bulleted or rounded nose to ease insertion. The cage may include teeth on the inferior  Signature Orthopaedics' Interbody Fusion Cages are available in a range of sizes to match varying patient anatomy, and may be used in the cervical, thoracic, lumbar and/or sacral spine, as specified on the particular cage's product labeling. Interbody Fusion Cages are intended to be used with graft materials and/or BMP, or similar. Signature Orthopaedics' Interbody Fusion Cages may be used with open and/or minimally invasive techniques (MIS), as specified in the particular devices surgical technique. 4 Pedicle Screw Systems Signature Orthopaedics' Pedicle Screw System is intended to provide immobilization and stabilisation of spinal segments in skeletally mature patients, as an adjunct to fusion in the cervical, thoracic, lumbar and sacral spine. Signature Orthopaedics' Pedicle Screw System consists of polyaxial screws, hooks, longitudinal rods, tulips, cap screws, cross connectors, lateral connectors and screw retainers. The pedicle screw system is implanted from a posterior approach, and used bilaterally at the required spinal levels. The pedicle screw system components are manufactured from titanium alloy per ISO5832-3, or cobalt-chrome alloy per ISO583212. Signature Orthopaedics Pedicle Screw System may be used in conjunction with the Signature Orthopaedics Facet Fusion Cage to provide stabilization during spinal fusion. The Signature Orthopaedics Pedicle Screw System is indicated for use only with open surgical techniques. 5  Anterior Spinal Fixation Plates  Signature Orthopaedics’ Anterior Spinal Fixation Plates are used as an anteriorly placed supplemental fixation device to provide temporary biomechanical stability until fusion is achieved. Additionally, when used with an interbody fusion cage, the anterior spinal fixation plate serves to prevent anterior expulsion of the cage. The devices are intended to be implanted using an anterior or anterolateral approach using the corresponding instrument sets. The plates consist of a main body which accommodate four variable angle bone screws to secure the plates into adjacent vertebrae. The plates are available in a range of sizes to match the patient's anatomy. The plates are contoured to better match the geometry of the anterior surface of the vertebral bodies. Screws are locked into position by an appropriate locking mechanism, to stabilise the vertebral segments. The subject plates and screw components are manufactured from titanium alloy per ISO5832-3. Signature Orthopaedics’ Anterior Spinal Fixation Plates should be used in conjunction with interbody fusion devices and/or posterior fixation constructs. Signature Orthopaedics’ Anterior Spinal Fixation Plates are indicated for use with both open and minimally invasive techniques (MIS). 6 Indications for Use The Signature Orthopaedics' spinal implant range is indicated for use in skeletally mature patients with the following conditions:             Arthrodesis required at any paired vertebral bodies in the cervical, thoracic, lumbar and/or sacral spine, as specified on the particular device's label Degenerative disc disease defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies Spinal stenosis Spinal deformities or curvatures Spondylolisthesis Trauma e.g. fracture or dislocation Pseudoarthrosis Previous failed fusion Tumour Can be used with osteobiological products such as OP1, BMP or similar  7 Contraindications for Use The Signature Orthopaedics Spinal Implant Range is contraindicated for use under the following conditions:  Osteoporosis  Active systemic infection or infection localized to the site of the proposed implantation  Any entity or condition that totally precludes the possibility of fusion, i.e., cancer, kidney dialysis, osteopenia, obesity, or foreign body sensitivity.  Patients whose activity, mental capacity, mental illness, or lifestyle may interfere with their ability to follow postoperative restrictions ADDITIONAL FACET FUSION CAGE CONTRAINDICATION:  8  Spinal fusion level associated with bilateral pars intra-articularis defects Precautions Following are specific precautions which should be understood by the surgeon and explained to the patient. These warnings do not include all precautions for surgery in general, but are important considerations particular to Signature Orthopaedics' Spinal Implant Range.  Bending, notching and/or scratching of the devices are not recommended. Alterations of the implant geometry or surface finish can have detrimental effects on the endurance properties or performance of the implant. Facet Fusion Cages, and Interbody Fusion Cages are supplied sterile and intended for single use only. Resterilisation and re-use of these devices is strictly prohibited. Resterilisation of these devices may alter device material properties including reducing mechanical properties and/or biocompatibility. Pedicle Screw System and Anterior Lumbar Fixation Plate components are supplied nonsterile, and intended for single use only. Re-use of any spinal implant may result in crosscontamination between patients and decreased mechanical performance. Explanted devices are to be disposed of immediately. Postoperative care and the patient’s ability and willingness to follow instructions are one of the most important aspects of successful bone healing. The patient must be made aware of the limitations of the implant and follow postoperative care regimen as instructed by their physician. Appropriate pre-operative planning and surgical technique can minimize complications. Proper patient selection and the patient’s ability to comply with the post-operative prescribed treatment will greatly affect the clinical outcome. It is important to screen patients and select the optimal therapy given physical and / or mental activity limitations. If fusion does not occur, spinal fixation devices cannot withstand activity levels placed on normal healthy bone. It is unreasonable to assume that any implant can withstand unsupported in-vivo loading indefinitely. An explanted implant should never be re-used. Do not treat patients with implants that have been even momentarily placed in a different patient. If explanted, follow standard hospital procedures for disposing of biologically hazardous material. Signature Orthopaedics does not recommend MR imaging for any patients implanted with products from their spinal implant range without prior consultation with an expert radiologist for assessment of potential adverse events such as device movement, localized burns, torsional or shear strain on the implanted device. Signature Orthopaedics’ spinal implant range have not been evaluated for safety and compatibility in the MR environment. They have not been tested for heating, migration, or image artefact in the MR environment. The safety of Signature Orthopaedics spinal implant range in the MR environment is unknown. Scanning a patient who has this device may result in patient injury. Do not alter or modify any implant or instrument. Repairs should only be performed at Signature Orthopaedics sites. Due to the proximity of vascular and neurologic structures to the implantation site, there are risks of serious or fatal hemorrhage and risks of neurologic damage with the use of these products. Only approved Signature Orthopaedics instruments should be used in conjunction with the implants covered in this document.
File Type: PDF
File Size: 207 KB
File Name: Signature Orthopaedics - 131-111-001 - Consolidated Spine Instructions for Use - 2022-04 - Rev X.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions