Deltec Cozmo® Insulin Pump Basics
Model 1800
Left programming key
Right programming key
To select any action listed in the left-hand corner of the screen, press the left button on the key pad
To select any action listed in the right-hand corner of the screen, press the right button on the key pad
Up/down arrow keys Push to change a highlighted or ‘boxed’ word/number
Screen saver/sleep mode
Home screens
• Time and current basal rate is displayed
All home screens show:
• Turn back light on by pushing the down arrow button
• Amount of insulin remaining in the cartridge (top left) • Amount of battery life remaining (top right) • Stop (left button) • Menu (right button)
Menu Map for the Deltec Cozmo® Insulin Pump
Model 1800
START Home Screens Bolus History Menu Bolus Summary Bolus History Therapy Scorecard Stop Delivery
Home Screen 1 - Basal Rate and Custom Name Home Screen 2 - Bolus Delivered Home Screen 3 - Custom Text IOB Home Screen - Insulin on Board (optional) BG Home Screen - Blood Glucose (optional) SR Home Screen - Site Reminder (optional) TR Home Screen - Temporary Rate (optional) (Day of Week) Home Screen - Weekly Schedule (optional) DIS Home Screen - Disconnect (when in use)
Blood Glucose Menu Enter BG Value BG History Therapy Scorecard Stop Delivery
Bolus All Delivery Temporary Rate Extended Bolus
Main Menu
History Menu Bolus Summary Bolus History Complete History Delivery Summary Avg Summary Basal as % TDD Avg Basal as % TDD BG History Avg BG History
Stop Delivery Menu
Reconnect (when Disconnect is in use) Meal Bolus Correction Bolus (optional) Meal Maker (optional) Temporary Rate (optional) Basal Pattern (if Weekly Schedule is off) Weekly Schedule Load History Setup Basal Testing Disconnect (optional)
QuickStart Menu
Personalize Menu
Setup Menu
Alerts History Regional Settings Display Advanced
QuickStart Pump Settings Personalize Delivery Pump Settings Menu
Backlight Always On?
Use Weekly Schedule
Delivery Setup Menu
Extend Display Timeout
Enable Disconnect Bolus
Meal Bolus Correction Bolus Basal Pattern Temporary Rate
Menu
Enable Hypo Manager Use Specific Target BG for Hypo Manager? Specify Hypo Manager Target BG Specify Hypo Manager Lockout Period
Time and Date Beep/Vibrate Program Lock Pump ID
If NO
Smiths Medical ASD, Inc. St. Paul, MN 55112, USA Phone: 1-214-618-0218 Toll-Free USA: 1-800-258-5361 www.smiths-medical.com
Smiths Medical is part of the global technology business Smiths Group plc.
Menu
Time and Date Program Bolus Using (Grams/Carbs or Units/Insulin) Insulin to Carbohydrate Ratio Bolus Maximum BG Measurement Turn Correction Bolus On Correction Factor Duration of Insulin Action Target BG Maximum Basal Rate Edit Current Basal Pattern (when Weekly Schedule is off)
www.CozMore.com Customer Support 800-826-9703
CozMore, Deltec Cozmo, CoZmonitor, Meal Maker, Hypo Manager, and the Smiths Medical and CozMore design marks are trademarks of Smiths Medical. The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark Office and certain other countries. ©2011 Smiths Medical. All rights reserved. 2/11 DI191942