User Guide \n
174 Pages
Preview
Page 1
PowerPark
User Guide
SonoSite, Inc. 21919 30th Drive SE Bothell, WA 98021 USA T: 1-888-482-9449 or 1-425-951-1200 F: 1-425-951-1201 SonoSite Ltd Alexander House 40A Wilbury Way Hitchin Herts SG4 OAP UK T: +44-1462-444800 F: +44-1462-444801 Caution:
United States federal law restricts this device to sale by or on the order of a physician.
H-Universal, SonoSite, the SonoSite logo, and V-Universal are trademarks or registered trademarks of SonoSite, Inc. Non-SonoSite product names may be trademarks or registered trademarks of their respective owners. Patents pending.
P13405-01 02/2010 Copyright 2010 by SonoSite, Inc. All rights reserved.
iv
English
PowerPark User Guide
Deutsch
Contents
Español
Introduction ...1 About the PowerPark ...2 Docking the stand ...3 Troubleshooting ...4 Safety ...7 Specifications ...9
Introduction Français
The PowerPark User Guide explains how to use, clean, and disinfect the PowerPark. It also provides information on safety and specifications. To attach or remove the PowerPark from the stand, refer to the PowerPark assembly instructions. For information on the stand or ultrasound system, see its user guide. WARNING:
To avoid the risk of patient injury, misdiagnosis, or user injury, read all the warnings in the ultrasound system user guide and supplemental guides. Italiano
Conventions The user guide follows these conventions: • A WARNING describes precautions necessary to prevent injury or loss of life. • A Caution describes precautions necessary to protect the products.
Português
• Numbered steps in procedures must be performed in order. • Items in bulleted lists do not require a sequence. • Single-step procedures begin with . Symbols and terms used on the system are explained in the ultrasound system user guide.
Customer assistance and comments Questions and comments are encouraged. SonoSite is interested in your feedback regarding the system and the user guide. Please call SonoSite at 888-482-9449 in the US. Outside the US, call the nearest SonoSite representative. You can also e-mail SonoSite at [email protected].
PowerPark User Guide
1
For technical support, please contact SonoSite as follows: SonoSite Technical Support Phone (US or Canada):
877-657-8118
Phone (Outside US and Canada):
425-951-1330 Or call your local representative.
Fax:
425-951-6700
E-mail:
Web site:
www.sonosite.com
Europe Service Center Phone:
+44-(0)1462-444-800
E-mail:
About the PowerPark The PowerPark is a docking station for the V-Universal™ Stand or H-Universal™ Stand. It lets you dock the stand-without manually connecting the power cord-to charge the PowerPack battery (if present) and the ultrasound system battery. The PowerPark includes two parts: the dock (which remains on the floor against the wall) and the stand module (which attaches to the underside of the stand). Stand module
Dock
Figure 1 PowerPark includes two parts
2
English
Docking the stand WARNING:
The equipment shall be connected to a center-tapped single phase supply circuit when users in the United States connect the equipment to a 240V supply system. Deutsch
To dock the stand Wheel the stand backward into the dock. See Figure 2.
The stand module (on the underside of the stand) snaps into place as it connects with the dock. The connection indicator glows green. To undock the stand, wheel it away from the dock. The connection indicator turns off. Español Français Italiano
Connection indicator Português
Figure 2 Wheel the stand into the dock to connect
To connect to AC power manually If necessary, you can connect to AC power manually-for example, if you need to use the system despite a depleted battery. Connect the system power cord to the AC adapter on the stand module and to the electrical
outlet. Caution:
To avoid a possible trip hazard, do not connect to AC power manually if the stand is docked.
PowerPark User Guide
3
AC adapter
Figure 3 The AC adapter lets you connect to AC power manually.
Troubleshooting Symptoms and solutions Symptom
Solution
PowerPark does not charge the battery
• Make sure that the electrical outlet has power. • Make sure that the dock circuit breaker is turned on. • Reset the stand-module circuit breaker if tripped. • Make sure that the stand module is fully connected to the dock.
Stand module does not connect to the dock
Make sure that the floor is clean, flat, and rigid. Avoid thick carpeting.
To turn the dock circuit breaker on or off The circuit breaker on the PowerPark dock is typically set to the ON position but trips if there is a power event (for example, power surge). 1 Undock the stand. 2 Disconnect the power cord from the wall outlet, and pull the PowerPark dock away from the wall. The circuit breaker is now accessible. See Figure 4 on page 5. 3 Press the circuit breaker to the desired position: ON ( | ) or OFF (O).
4
English
Circuit breaker
Deutsch
Figure 4 The dock circuit breaker is on the side toward the wall. Español
To reset the stand-module circuit breakers One or both of the circuit breakers on the stand module trip if there is a power event (for example, power surge) and need to be reset. 1 Undock the stand, and remove the ultrasound system and any loose items. 2 Tip the stand onto its side, allowing access to its underside.
Français
3 Press down each circuit breaker switch. • On a correctly set circuit breaker, the switch is pressed down. • On a tripped circuit breaker, the switch is popped up and exposes a white plastic area. Note: If you cannot press down the switch and if no white area is exposed, the circuit breaker is untripped.
Italiano
Circuit breakers
Português
Figure 5 The stand-module circuit breakers are on the stand’s underside.
PowerPark User Guide
5
Cleaning and disinfecting WARNING:
To avoid electrical shock, always disconnect the power supply before cleaning the PowerPark. To avoid injury, always use protective eyewear and gloves when performing cleaning and disinfecting procedures. To avoid infection: • Ensure that the solution expiration date has not passed. • The level of disinfection required for a product is dictated by the type of tissue it contacts during use. Ensure that the solution strength and duration of contact are appropriate for the equipment. For information, see the disinfectant label instructions and the recommendations of the Association for Professionals in Infection Control and Epidemiology (APIC) and FDA.
Caution:
Use only recommended cleaners or disinfectants on surfaces. Immersion-type disinfectants are not tested for use on surfaces. To avoid damaging the connectors on the dock or preventing a sound connection between it and stand module, keep the floor around the dock clean and free of debris.
To clean and disinfect the PowerPark You can clean and disinfect the exterior surface of the PowerPark using a recommended cleaner or disinfectant. For the most recent list of approved products, see www.sonosite.com. Follow the links for Support and Documents. 1 Unplug the power supply, and detach any cables. 2 Clean the surfaces using a soft cloth lightly dampened in a mild soap or detergent cleaning solution. Apply the solution to the cloth rather than the surface. 3 Wipe the surfaces with the disinfecting solution. Follow the manufacturer’s instructions for the disinfecting solution, including exposure time and temperature for effective disinfection. 4 Air dry or towel dry with a clean cloth.
6
English
Safety Electrical safety classification The PowerPark is classified as Class I equipment.
Non AP/APG
The PowerPark is not suitable for use in the presence of flammable anaesthetics.
Deutsch
Class I equipment
Electrical safety Español
WARNING:
To avoid the risk of a shock hazard, do not plug the power cord of the PowerPark dock or PowerPark stand module into a multiple portable socket outlet (MPSO) or use an extension cord. To avoid the risk of electrical shock:
Français
• Use only properly grounded equipment. Shock hazards exist if the power supply is not properly grounded. Grounding reliability can only be achieved when equipment is connected to a receptacle marked “Hospital Only” or “Hospital Grade” or the equivalent. The grounding wire must not be removed or defeated. • Use only accessories and peripherals recommended by SonoSite, including the power supply. Use the PowerPark only with power input stated on the label. • Do not place the PowerPark dock in a wet environment.
Italiano
To avoid system malfunction and the risk of electrical shock, follow the PowerPark assembly instructions. To avoid the risk of electrical shock and fire hazard, inspect the power supply, plugs, cables, and power cords on a regular basis for damage.
PowerPark User Guide
Português
To avoid possible electrical shock or electromagnetic interference, verify proper operation and compliance with relevant safety standards for all equipment before clinical use. Connecting additional equipment to the ultrasound system constitutes configuring a medical system. SonoSite recommends verifying that the system, all combinations of equipment, and accessories connected to the ultrasound system comply with JACHO installation requirements and/or safety standards AAMI-ES1, NFPA 99, IEC 60601-1-1, and IEC 60601-1-2, and are certified according to IEC 60950 (Information Technology Equipment (ITE)).
7
Equipment safety Caution:
Excessive bending or twisting of cables can cause a failure or intermittent operation. Improper cleaning or disinfecting of any part of the accessories and peripherals can cause permanent damage. For cleaning and disinfecting instructions, see “Cleaning and disinfecting” on page 6 and the manufacturer’s operating instructions.
Electromagnetic compatibility (EMC) See the safety section of the ultrasound system user guides for information on electromagnetic compatibility with IEC 60601-1-2, including the Manufacturer’s Declaration.
Labeling symbols For additional labeling symbols used, see the ultrasound system user guide. Table 1: Labeling Symbols Symbol
Definition Alternating current Protective earth (ground)
ON (power) OFF (power)
8
English
Specifications Dimensions Approximate dimensions of the PowerPark dock are as follows:
Deutsch
• Width: 15.00 in (38.1 cm) • Depth: 4.88 in. (12.4 cm) • Length: 4.88 in. (12.4 cm) • Weight (including cord): 11.3 lbs. (5.1 kg)
Español
Environmental limits Operating: 10 to 40°C; 15 to 95% R.H.; 700 hPa to 1060 hPa Shipping/Storage: -20 to 60°C; 15 to 95% R.H.; 500 hPa to 1060 hPa
Français
Electrical PowerPark Dock Supply Input: 100-240 VAC, 50/60 Hz, 8-3.3 A PowerPark Stand-Module Supply Input: 100-240 VAC, 50/60 Hz, 8-3.3 A PowerPark Stand-Module Supply Output: 100-240 VAC, 50/60 Hz, 8-3.3 A
Italiano Português
PowerPark User Guide
9
PowerPark
用户指南
PowerPark
使用者手冊
P13405-01
*P13405-01*