SonoSite
P21x Transducer User Guide Supplement
16 Pages
Preview
Page 1
Manufacturer
EC Authorized Representative
Australia Sponsor
FUJIFILM SonoSite, Inc.
FUJIFILM SonoSite B.V.
FUJIFILM SonoSite Australasia Pty Ltd
21919 30th Drive SE
Joop Geesinkweg 140
114 Old Pittwater Road
Bothell, WA 98021 USA
1114 AB Amsterdam,
BROOKVALE, NSW, 2100
T: +1-888-482-9449 or +1-425-951-1200
The Netherlands
Australia
F: +1-425-951-1201
Caution
United States federal law restricts this device to sale by or on the order of a physician.
EDGE, SONOSITE and the SONOSITE logo are trademarks and registered trademarks of FUJIFILM SonoSite, Inc. in various jurisdictions. FUJIFILM is a registered trademark of FUJIFILM Corporation. Value from Innovation is a trademark of FUJIFILM Holdings America Corporation. US 9,151,832; US 8,956,296; US 8,861,822; US 8,858,436; US 8,834,372; US 8,805,047; US 8,527,033; US 8,500,647; US 8,439,840; US 8,398,408; US 8,355,554; US 8,216,146; US 8,213,467; US 8,147,408; US 8,137,278; US 8,088,071; US 8,066,642; US 8,052,606; US 7,819,807; US 7,804,970; US 7,740,586; US 7,686,766; US 7,604,596; US 7,591,786; US 7,588,541; US 7,534,211; US 7,449,640; US 7,169,108; US 6,962,566; US 6,648,826; US 6,575,908; US 6,569,101; US 6,471,651; US 6,416,475; US 6,383,139; US 6,364,839; US 6,203,498; US 6,135,961; US 5,893,363; US 5,817,024; US 5,782,769; US 5,722,412; AU: 730822; AU: 727381; CA 2,372,152; CA: 2,371,711; CN103237499; CN101231457; CN 98108973.9; CN 98106133.8; CN 97113678.5; DE 69831698.3; DE 69830539.6; DE 69730563.5; DE 602004027882.3; DE 602004023816.3; DE: 60034670.6; DE 60029777.2; EP 1589878; EP 1552792; EP 1180971; EP 0875203; EP 0815793; EP 1180970; EP 0881492; ES 2229318; ES 159878; ES 1552792; ES 0881492; FR 158978; FR 1552792; FR 1180970; FR 0881492; FR 0875203; FR 0815793; GB 158978; GB 1552792; GB 1180971; GB 1180970; GB 0881492; GB 0875203; GB 0815793; IT 1589878; IT 1552792; IT 0881492; IT 0815793; JP 5782428; JP 4696150; KR 532359; KR 528102; NO 326814; NO 326202 and pending. All other trademarks are the property of their respective owners. Part number: P28967-01 Publication date: April 2020 Copyright © 2020 FUJIFILM SonoSite, Inc. All rights reserved.
Sonosite Edge II P21x Transducer User Guide Supplement Introduction ... 1 Document conventions ... 2 Getting Help ... 2 Imaging modes ... 3 Cleaning and disinfecting ... 3 Safety ... 4 Compatible accessories and peripherals ... 4 Labeling symbols ... 4 Acoustic output ... 5 Guidelines for reducing MI and TI ... 5 Output display ... 6 Transducer surface temperature rise ... 6 Acoustic output tables ... 7
Introduction This user guide supplement provides information on the P21x transducer, compatible with the Sonosite Edge II ultrasound system. The Sonosite Edge II ultrasound system is a general purpose ultrasound system. It is intended for use by qualified physicians and healthcare professionals for evaluation by ultrasound imaging or fluid flow analysis of the human body. FUJIFILM Sonosite is adding an existing transducer, the P21x, to the Sonosite Edge II ultrasound system in compliance with USFDA Guidance Marketing Clearance of Diagnostic Ultrasound Systems and Transducers issued June 27, 2019. The P21x transducer is already marketed for use on Sonosite M-Turbo ultrasound system. This supplement adds the transducer with limited exam types to the Sonosite Edge II ultrasound systems, which are cardiac, abdomen and lung. The clinical indication for the Sonosite Edge II does not change from previous clearance. In accordance with the Enforcement Policy for Imaging Systems Used During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency, FUJIFILM Sonosite reminds users that imaging devices are not intended for the diagnosis of COVID-19. In vitro diagnostic testing is currently the only definitive method to diagnose COVID-19.
Introduction
1
Document conventions The document follows these conventions: A WARNING describes precautions necessary to prevent injury or loss of life. A Caution describes precautions necessary to protect the products. A Note provides supplemental information. Numbered and lettered steps must be performed in a specific order. Bulleted lists present information in list format but do not imply a sequence. For a description of labeling symbols that appear on the product, see "Labeling symbols" in the ultrasound system user guide.
Getting Help For technical support, please contact FUJIFILM Sonosite as follows: Phone (U.S. or Canada)
+1-877-657-8118
Phone (outside U.S. or Canada)
+1-425-951-1330, or call your local representative
Fax
+1-425-951-6700
Web
www.sonosite.com
Europe Service Center
Main: +31 20 751 2020 English support: +44 14 6234 1151 French support: +33 1 8288 0702 German support: +49 69 8088 4030 Italian support: +39 02 9475 3655 Spanish support: +34 91 123 8451
Asia Service Center
+65 6380-5581
Printed in the United States of America.
2
Introduction
Imaging modes Table 1: Available exam types and imaging modes Imaging mode Transducer
Exam type
2D M Mode
Colora
PW Dopplerb
CW Doppler
P21x
Abdomen
CVD, CPD
-
Cardiac
CVD, Var
Lung
CVD, CPD
-
a
Var = Color Doppler Variance, which is available in the cardiac exam only. CPD = Color Power Doppler, which is available in all exams except the cardiac exam type. CVD = Color Velocity Doppler.
b
For the cardiac exam type, PW TDI is also available.
Cleaning and disinfecting Table 2: Approved cleaners Product
Compatible transducer
Minimum wet contact timea
SaniCloth AF3b
P21x
3 minutes
PI-Spray II
P21x
10 minutes
a
For maximum effectiveness, the component being cleaned must remain wet with disinfectant for a minimum period of time. b Qualified for use as an intermediate-level disinfectant for mycobacteria. Refer to the cleaners and disinfection document available at www.sonosite.com for a complete list of the most current cleaners and disinfectants.
Table 3: Approved high-level compatible disinfectants Disinfectanta
Compatible transducer
Temperature
Disinfectant soak duration
Cidex
P21x
25oC, 77oF
45 minutes
a
Refer to the cleaners and disinfection document available at www.sonosite.com for a complete list of the most current cleaners and disinfectants.
Imaging modes
3
Table 3: Approved high-level compatible disinfectants Disinfectanta
Compatible transducer
Temperature
Disinfectant soak duration
Cidex OPA
P21x
20oC, 68oF
12 minutes
a
Refer to the cleaners and disinfection document available at www.sonosite.com for a complete list of the most current cleaners and disinfectants.
Safety WARNING
To avoid device damage or patient injury, do not use the P21x needle-guide bracket on patients with pacemakers or medical electronic implants. The needle-guide bracket for P21x contains a magnet that is used to ensure that the bracket is correctly oriented on the transducer. The magnetic field in direct proximity to the pacemaker or medical electronic implant may have an adverse effect.
Compatible accessories and peripherals Table 4: Accessories and peripherals Description
Maximum Cable Length
P21x transducera
6.0 ft /1.8 m
a
For transducers, maximum cable length is measured between the strain reliefs. The stated lengths do not include the lengths of cable in the following locations: underneath the strain reliefs, inside the transducer enclosure, or inside the transducer connector.
Labeling symbols Table 5: Standards labeling symbols Symbol
Title
Standards development organization (SDO)
Medical Device
EU MDR
Reference number
Description
EU MDR Indicates the item the label is adhered Annex I, 23.2 to is categorized as a medical device (q) per the MDR, Annex 1, 23.2, q.
This is in addition to the labeling symbols listed in the Sonosite Edge II ultrasound system user guide.
4
Safety
Acoustic output Guidelines for reducing MI and TI Table 6: Guidelines for reducing mechanical index (MI) Transducer
Depth
P21x
Decrease or lower setting of parameter to reduce MI. Increase or raise setting of parameter to reduce MI. Table 7: Guidelines for reducing thermal index (TI) CPD Settings Transducer P21x
Box Width
Box Height
Box Depth
PRF
Depth
Optimize
PW Settings
(PRF)
Decrease or lower setting of parameter to reduce TI. Increase or raise setting of parameter to reduce TI.
Acoustic output
5
Output display Table 8: TI or MI 1.0 Transducer
Index
2D/ M Mode
CPD/ Color
PW Doppler
CW Doppler
P21x
MI
Yes
Yes
Yes
No
TIC, TIB, or TIS
Yes
Yes
Yes
Yes
Transducer surface temperature rise Table 9: Transducer Surface Temperature Rise, External Use (°C )
6
Test
P21x
Still air
17.2
Simulated use
8.5
Acoustic output
Acoustic output tables Table 10: Transducer model: P21x Operating mode: 2D TIS Index label Maximum index value
MI 1.4
Acoustic parameters Other information Operating controls
Below surface
# #
2.3 #
# #
171.7
- 3.65
fawf (MHz)
1.93
zpii,α (cm)
3.65
prr (Hz) srr (Hz) npps
4444 34.7 1
#
#
1.94
192 31.5
Ispta at zpii or zsii (mW/cm2)
41.9
Exam type Optimization Depth (cm) MB/THI Sector Width
Crd Res 4.7 On Any
pr at zpii (MPa)
#
At surface
-
zMI (cm)
Ispta,α at zpii,α or zsii,α (mW/cm2)
Below surface
(a) #
zs (cm)
Ipa,α at zpii,α (W/cm2)
TIC
1.92
P (mW) P1x1 (mW) zb (cm)
At surface
(a) #
Index component value pr,α at zMI (MPa)
At surface
TIB
2.44 Crd Pen 27 Off Narrow
(a) This index is not required for this operating mode; value is <1. (b) This transducer is not intended for transcranial or neonatal cephalic uses. # No data are reported for this operating condition since the global maximum index value is not reported for the reason listed. (Reference global maximum index value line.) - Not applicable for this transducer/mode.
Acoustic output
7
Table 11: Transducer model: P21x Operating mode: M Mode TIS Index label Maximum index value
MI 1.4
Acoustic parameters Other information Operating controls
Below surface
# #
fawf (MHz)
1.93
Ipa,α at zpii,α (W/cm2)
295
1.4 79.5 32.2
79.7
5.1 #
1.93
1.94
Crd Pen 30 Off
Abd Pen 32 Off
800 - 1 197.8
Ispta at zpii or zsii (mW/cm2)
396.2
Exam type Optimization Depth (cm) THI
Abd Res 10.2 On
pr at zpii (MPa)
1.1
3.50 5.1
Ispta,α at zpii,α or zsii,α (mW/cm2)
0.3
At surface
#
zMI (cm)
prr (Hz) srr (Hz) npps
Below surface
1.4 #
zs (cm)
zpii,α (cm)
TIC
1.94
P (mW) P1x1 (mW) zb (cm)
At surface
(a) #
Index component value pr,α at zMI (MPa)
At surface
TIB
2.72
(a) This index is not required for this operating mode; value is <1. (b) This transducer is not intended for transcranial or neonatal cephalic uses. # No data are reported for this operating condition since the global maximum index value is not reported for the reason listed. (Reference global maximum index value line.) - Not applicable for this transducer/mode.
8
Acoustic output
Table 12: Transducer model: P21x Operating mode: CPD/Color TIS Index label Maximum index value
MI 1.4
Acoustic parameters Other information Operating controls
Below surface
135.6 121.7
fawf (MHz)
1.93
Ipa,α at zpii,α (W/cm2)
295
Ispta at zpii or zsii (mW/cm2)
13.2
Mode Exam type 2D Optimization/Depth (cm) Color Optimization/PRF
pr at zpii (MPa)
THI Color box size
2.4 1.3
135.6 121.7
134.4
- 5.1
Ispta,α at zpii,α or zsii,α (mW/cm2)
1.3
At surface
-
zMI (cm)
prr (Hz) srr (Hz) npps
Below surface
1.3 1.3
zs (cm)
zpii,α (cm)
TIC
1.94
P (mW) P1x1 (mW) zb (cm)
At surface
1.3 1.3
Index component value pr,α at zMI (MPa)
At surface
TIB
5.1 2.16
2.16
2.16
CVD Abd Pen/7.5 Med/Any
CVD Lung Pen/4.7 Med/2500 Hz
CVD Lung Pen/4.7 Med/2500 Hz
On Any
N/A Small
N/A Small
CVD Lung Pen/4.7 Med/ 1524 Hz N/A Small
881 13.8 1 9.6 2.72
(a) This index is not required for this operating mode; value is <1. (b) This transducer is not intended for transcranial or neonatal cephalic uses. # No data are reported for this operating condition since the global maximum index value is not reported for the reason listed. (Reference global maximum index value line.) - Not applicable for this transducer/mode.
Acoustic output
9
Table 13: Transducer model: P21x Operating mode: CW Doppler TIS Index label Maximum index value
MI (a)
Acoustic parameters Other information Operating controls
Below surface
108.8 108.8
3.1 3.6
108.8 108.8
108.8
1.2 #
fawf (MHz)
#
Ipa,α at zpii,α (W/cm2)
#
Ispta at zpii or zsii (mW/cm2)
#
zpii,α (cm)
#
prr (Hz) srr (Hz) npps
# # #
Exam type Sample volume position
1.0
At surface
1.2
zMI (cm)
pr at zpii (MPa)
Below surface
3.6 0.9
zs (cm)
Ispta,α at zpii,α or zsii,α (mW/cm2)
TIC
#
P (mW) P1x1 (mW) zb (cm)
At surface
1.0 1.0
Index component value pr,α at zMI (MPa)
At surface
TIB
2.0
2.0
2.0
Crd Zone 0
Crd Zone 0
Crd Zone 0
# #
(a) This index is not required for this operating mode; value is <1. (b) This transducer is not intended for transcranial or neonatal cephalic uses. # No data are reported for this operating condition since the global maximum index value is not reported for the reason listed. (Reference global maximum index value line.) - Not applicable for this transducer/mode.
10
Acoustic output
Table 14: Transducer model: P21x Operating mode: PW Doppler TIS Index label Maximum index value
MI 1.2
Acoustic parameters Other information Operating controls
Below surface
zpii,α (cm)
fawf (MHz) prr (Hz) srr (Hz) npps
Ipa,α at zpii,α (W/cm2)
Ispta,α at zpii,α or zsii,α (mW/cm2)
200.3 78.4
1.0
At surface 2.8
3.7 93.8 93.8
201.2
3.1 0.60 5.0 5.0 2.15
2.22
2.17
2.12
Crd 3 3906 Zone 4
Crd 1 15625 Zone 0
Crd 1 3906 Zone 5
1562 - 1 216 400.8
Ispta at zpii or zsii (mW/cm2)
830.4
Exam type Sample volume size (mm) PRF (Hz) Sample volume position
Crd 1 1563 Zone 2
pr at zpii (MPa)
Below surface
3.7 1.3
zs (cm)
zMI (cm)
TIC
1.73
P (mW) P1x1 (mW) zb (cm)
At surface
1.3 0.8
Index component value pr,α at zMI (MPa)
At surface
TIB
2.5
(a) This index is not required for this operating mode; value is <1. (b) This transducer is not intended for transcranial or neonatal cephalic uses. # No data are reported for this operating condition since the global maximum index value is not reported for the reason listed. (Reference global maximum index value line.) - Not applicable for this transducer/mode.
Acoustic output
11
12
Acoustic output
P28967-01
*P28967-01*