Castroviejo Calipers Instructions for Use

3 Pages

Updated Aug 2022 ERS Page 1 of 3  CAUTION: Normal repeated use has minimal effect on  Sontec Instruments  INSTRUCTIONS FOR USE Castroviejo Calipers: This is a reusable device, packaged non-sterile. It is steam sterilizable.  INDICATIONS  Sontec Instruments Castroviejo Calipers are manually operated instruments designed to perform specific functions such as measuring during a TPLO (Tibial Plateau Leveling Osteotomy) and Ophthalmic surgical procedures. Castroviejo Calipers are used for the precise measurement of the structures of the tibial plateau and in ophthalmic procedures measures the eye including cornea and pupils. When closed, they resemble a closed V-shape with very fine distal tips and a horizontal measuring bar at the distal tips. The center of the caliper has a screw-type device to hold the distal tips open or closed, and the box lock area has a large holding screw. When closed, the distal tips should evenly meet and be nick- and burr-free. Inspect them with a magnification device.  Note: Inspection points include ensuring that the distal tips are clean and intact. Check the box lock screw to ensure it is intact and clean. Also check the locking screw area for cleanliness and function and protect the tips when packaging.  CONTRAINDICATION  These instruments should not be used for anything other than their intended use.  Warnings/Precautions:  CAUTION: US Federal Law restricts these devices to sale  by or on the order of a physician, and the device is intended for use only by or under direction of trained surgeons.  CAUTION: These reusable devices are packaged non-sterile and are steam sterilizable  these instruments. End of life is normally determined by wear and damage due to use.  CAUTION: Use of this instrument for any purpose, or in any manner other than those described here may cause instrument damage or failure which could result in serious patient injury or death. If needed, all metal products or fragments thereof can be located by means of an X-Ray. CAUTION: The World Health Organization recommends  the longest exposure times when there is concern regarding HIV, TSE, CJD, etc. contamination. It is the user’s responsibility to determine what contamination exists and what procedure is appropriate to ensure proper sterilization.  WARNING: DO NOT flash sterilize these instruments. The instruments have not been designed for flash sterilization. Discard instruments after suspected Creutzfeldt-Jakob Disease (CJD) exposure – these instruments have not been designed to withstand the chemical and thermal exposures recommended to eradicate prions. Every surgical instrument must be properly inspected, cleaned, lubricated, and sterilized before the initial use and all subsequent uses. Carefully examine each surgical instrument for proper function and damage of any sort prior to and after each use. It is extremely important to check all working parts including blades, locks, points, stops, ratchets, screws, etc. Instruments that show any sign of damage or corrosion should be repaired or replaced prior to further use. Instruments may only be used for their intended purpose in their respective surgical specialties by properly trained and qualified personnel. The surgeon (qualified user) shall be responsible for the proper instrument selection for each application, for obtaining the appropriate training for use, for insuring the proper care and sterilization, and for their operative use. Sontec Instruments, Inc. does not have any control over the ultimate use of the surgical instruments and therefore,  cannot accept any responsibility or liability for any damages caused by inappropriate application and use or by inappropriate sterilization and maintenance of the instruments. Materials Used where applicable: Sontec Instruments are manufactured using either high quality stainless steel, titanium (including titanium alloys), or aluminum unless otherwise stated. These metals are durable and will last for years if properly used and maintained. It is the user’s responsibility to ensure continuous and proper care of the surgical instruments in addition to proper preparation, cleaning, and sterilization. Stainless Steel – Stainless steel provides excellent, but not complete protection from rust and corrosion. The main enemies of stainless steel are organic materials not removed immediately after use, chloride ions, common salts and other contaminants contained in tap water. The use of proper cleaners, disinfectants and distilled water cannot be overemphasized. Titanium – Titanium and titanium alloys are used to make light weight instruments. These instruments can be handled and treated like stainless steel instruments. Titanium instruments are often anodized blue for color identification. Aluminum – Aluminum is also used to make light weight instruments. However, only neutral, non-alkaline cleaners and fully de-mineralized water may be used with aluminum instruments. Tungsten Carbide – Chemical/cold sterilization should never be used for instruments with tungsten carbide inserts/edges. The solutions used are harmful to tungsten carbide. Cleaning and Sterilizing Guidelines: Sontec Instruments, Inc. has no control over the conditions or contaminants the user will subject the instruments to, therefore, it is the ultimate responsibility of the user to determine what cleaning and sterilizing methods and additional steps might be needed to properly remove all known and unknown organisms or contaminants. In all circumstances, the user should closely follow the recommendations provided by the manufacturers of the cleaning/sterilizing products and equipment used.
File Type: PDF
File Size: 749 KB
File Name: Sontec Instruments - Castroviejo Calipers Instructions for Use - 2022-08 - Not Listed.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions