Instructions for Use
44 Pages
Preview
Page 1
4-171-242-14 (1)
LCD Monitor
Instructions for Use Before operating the unit, please read this manual thoroughly and retain it for future reference.
LMD-2451MD
© 2009 Sony Corporation
Owner’s Record The model and serial numbers are located at the rear. Record these numbers in the spaces provided below. Refer to these numbers whenever you call upon your Sony dealer regarding this product.
WARNING Make sure the surface is wide enough so that this apparatus’s width and depth don’t exceed the surface’s edges. If not, this apparatus may lean or fall over and cause an injury.
Model No. ____________________ Serial No. ____________________
Consult with Sony qualified personnel for mounting arm, wall or ceiling mount installation.
WARNING
Indications for Use/Intended Use The Sony LMD-2451MD LCD Monitor is intended to provide color video displays of images from surgical camera systems. The LMD-2451MD is a widescreen, high definition monitor for real-time use during minimally invasive surgical procedures including arthroscopy (orthopedic surgery), laparoscopy (general and gynecological surgery), thoracoscopy, endoscopy (general, gastroenterological and ENT surgery) and general surgery.
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. No modification of this apparatus is allowed. WARNING THIS APPARATUS MUST BE EARTHED. WARNING To disconnect the main power, unplug the AC plug. When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect the power plug to an easily accessible socketoutlet near the unit. If a fault should occur during operation of the unit, operate the disconnect device to switch the power supply off, or disconnect the power plug. CAUTION This LCD monitor should only be used with a specified monitor stand. For information on suitable stands, refer to “Specifications.” Installation of the LCD monitor on any other stand may result in instability, possibly leading to injury. WARNING: Using this unit at a voltage other than 120 V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel. CAUTION The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the apparatus. Do not install the appliance in a confined space, such as book case or built-in cabinet. CAUTION The unit is not disconnected from the AC power source (mains) as long as it is connected to the wall outlet, even if the unit itself has been turned off.
2
For the customers in the U.S.A. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of part 15 of FCC Rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For the customers in Europe This product has been manufactured by or on behalf of Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 1080075 Japan. Inquiries related to product compliance based on European Union legislation shall be addressed to the authorized representative, Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Germany. For any service or guarantee matters, please
refer to the addresses provided in the separate service or guarantee documents.
If you have questions on the use of the above Power Cord / Appliance Connector / Plug, please consult a qualified service personnel.
Symbols on the unit Symbol
Location
This symbol indicates
Bottom
Power switch. Press to turn the monitor on.
Bottom
Power switch. Press to turn the monitor off.
WARNING on power connection for medical use Please use the following power supply cord. With connectors (plug or female) and cord types other than those indicated in this table, use the power supply cord that is approved for use in your area. United States and Canada
Rear
-
The equipotential terminal which brings the various parts of a system to the same potential.
Rear
Functional earth terminal
Front
Key inhibit The setting are locked so that they cannot be changed.
This symbol is located on the rear of the unit. See page 19 of these instructions for details about how to attach the connector cover. Refer to the operating instructions Follow the directions in the operating instructions for parts of the unit on which this mark appears. This symbol indicates the manufacturer, and appears next to the manufacturer’s name and address. Caution When you dispose of the unit or accessories, you must obey the laws in the relative area or country and the regulations in the relative hospital. WARNING on power connection Use a proper power cord for your local power supply. 1. Use the approved Power Cord (3-core mains lead) / Appliance Connector / Plug with earthing-contacts that conforms to the safety regulations of each country if applicable. 2. Use the Power Cord (3-core mains lead) / Appliance Connector / Plug conforming to the proper ratings (Voltage, Ampere).
Plug Type
HOSPITAL GRADE*
Cord Type
Min. Type SJT Min. 18 AWG
Minimum Rating for Plug and Appliance Couplers
10A/125V
Safety Approval
UL Listed and CSA
*Note: Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked ‘Hospital Only’ or ‘Hospital Grade’.
For the customers in Canada This Class A digital apparatus complies with Canadian ICES-003. This unit has been certified according to Standard CAN/ CSA-C22.2 No.60601-1. For the customers in the U.S.A and Canada When you use this product connected to 240 V single phase, be sure to connect this product to a center tapped circuit. Important safeguards/notices for use in the medical environments 1. All the equipments connected to this unit shall be certified according to Standard IEC60601-1, IEC60950-1, IEC60065 or other IEC/ISO Standards applicable to the equipments. 2. Furthermore all configurations shall comply with the system standard IEC60601-1-1. Everybody who connects additional equipment to the signal input part or signal output part configures a medical system, and is therefore, responsible that the system complies with the requirements of the system standard IEC60601-1-1. If in doubt, consult the qualified service personnel. 3. The leakage current could increase when connected to other equipment. 4. For this particular equipment, all accessory equipment connected as noted above, must be connected to mains via an additional isolation transformer conforming with the construction requirements of IEC60601-1 and providing at least Basic Insulation. 5. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause
3
interference to other equipment. If this unit causes interference (which can be determined by unplugging the power cord from the unit), try these measures: Relocate the unit with respect to the susceptible equipment. Plug this unit and the susceptible equipment into different branch circuit. Consult your dealer. (According to standard EN606011-2 and CISPR11, Class B, Group 1) 6. Model LMD-2451MD is a monitor intended for use in a medical environment to display pictures from cameras or other systems, other than diagnostic Xray equipment.
Important EMC notices for use in the medical environments • The LMD-2451MD needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this instructions for use. • The portable and mobile RF communications equipment such as cellular phones can affect the LMD-2451MD. Warning The use of accessories and cables other than those specified, with the exception of replacement parts sold by Sony Corporation, may result in increased emissions or decreased immunity of the LMD-2451MD.
Guidance and manufacturer’s declaration-electromagnetic emissions The LMD-2451MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD-2451MD should assure that it is used in such an environment. Emission test
Compliance
Electromagnetic environment-guidance
Group 1
The LMD-2451MD uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11 RF emissions Class B CISPR 11 Harmonic emissions Class D IEC 61000-3-2 Voltage fluctuations/ flicker emissions
Complies
IEC 61000-3-3
Warning If the LMD-2451MD should be used adjacent to or stacked with other equipment, it should be observed to verify normal operation in the configuration in which it will be used.
4
The LMD-2451MD is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Guidance and manufacturer’s declaration - electromagnetic immunity The LMD-2451MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD2451MD should assure that it is used in such as environment. Immunity test Electrostatic discharge (ESD)
IEC 60601 test level
Compliance level
Electromagnetic environment - guidance
±6 kV contact
±6 kV contact
±8 kV air
±8 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Electrical fast transient/burst
±2 kV for power supply lines
±2 kV for power supply lines
Mains power quality should be that of a typical commercial or hospital environment.
IEC 61000-4-4
±1 kV for input/ output lines
±1 kV for input/ output lines
Surge
±1 kV differential mode
±1 kV differential mode
±2 kV common mode
±2 kV common mode
< 5% UT (> 95% dip in UT) for 0.5 cycle
< 5% UT (> 95% dip in UT) for 0.5 cycle
40% UT (60% dip in UT) for 5 cycles
40% UT (60% dip in UT) for 5 cycles
70% UT (30% dip in UT) for 25 cycles
70% UT (30% dip in UT) for 25 cycles
< 5% UT (> 95% dip in UT) for 5 sec
< 5% UT (> 95% dip in UT) for 5 sec
3 A/m
3 A/m
IEC 61000-4-2
Mains power quality should be that of a typical commercial or hospital environment.
IEC 61000-4-5
Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11
Power frequency (50/60Hz) magnetic field
Mains power quality should be that of a typical commercial or hospital environment. If the user of the LMD-2451MD requires continued operation during power mains interruptions, it is recommended that the LMD-2451MD be powered from an uninterruptible power supply or a battery.
Power frequency magnetic fields should be at least characteristic of a typical location in a typical commercial or hospital environment.
IEC 61000-4-8 NOTE: UT is the a.c. mains voltage prior to application of the test level.
5
Guidance and manufacturer’s declaration - electromagnetic immunity The LMD-2451MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD2451MD should assure that it is used in such as environment. Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the LMD-2451MD, including cables, than the recommended separation distance calculated from the equation appliance to the frequency of the transmitter. Recommended separation distance
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
3 Vrms
d = 1.2 √P d = 1.2 √P 80 MHz to 800 MHz d = 2.3 √P 800 MHz to 2.5 GHz
Radiated RF
3 V/m
IEC 61000-4-3
80 MHz to 2.5 GHz
3 V/m
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with following symbol:
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the LMD-2451MD is used exceeds the applicable RF compliance level above, the LMD-2451MD should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the LMD-2451MD. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
6
Recommended separation distances between portable and mobile RF communications equipment and the LMD2451MD The LMD-2451MD is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the LMD-2451MD can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (Transmitters) and the LMD-2451MD as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W
Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d = 1.2 √P
80 MHz to 800 MHz d = 1.2 √P
800 MHz to 2.5 GHz d = 2.3 √P
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Disposal of Old Electrical & Electronic Equipment (Applicable in Republic of India)
This symbol indicates that this product shall not be treated as household waste and may not be dropped in garbage bins. Product owners are advised to deposit their product at the nearest collection point for the recycling of electrical and electronic equipment. Your co-operation shall facilitate proper disposal & help prevent potential negative consequences/hazards to the environment and human health, which could otherwise be caused by inappropriate waste disposal including improper handling, accidental breakage, damage and/ or improper recycling of e-waste. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local civic office, your household waste disposal service provider or the store where you made the purchase. You may contact our company’s toll free number in India for assistance. This product complies with the “India E-waste Rule 2011”. The Ewaste Rules, 2011 is an Indian directive aimed at reducing the harmful environmental impact of waste electrical equipment by restricting the use of known hazardous substances. As of 1st May 2012, new
electrical and electronic equipment introduced into the market may no longer contain the following chemicals or its specified maximum concentration levels: Lead, Mercury, Hexavalent Chromium, Polybrominated Biphenyls (PBB) or Polybrominated Diphenylethers (PBDE) - in concentrations exceeding 0.1 weight % and Cadmium - 0.01 weight %, except of exemptions set in Schedule 2 of the aforesaid Rule. For the customers in the U.S.A. SONY LIMITED WARRANTY - Please visit http:// www.sony.com/psa/warranty for important information and complete terms and conditions of Sony’s limited warranty applicable to this product. For the customers in Canada SONY LIMITED WARRANTY - Please visit http:// www.sonybiz.ca/solutions/Support.do for important information and complete terms and conditions of Sony’s limited warranty applicable to this product. For the customers in Europe Sony Professional Solutions Europe - Standard Warranty and Exceptions on Standard Warranty. Please visit http://www.pro.sony.eu/warranty for important information and complete terms and conditions. For the customers in Korea SONY LIMITED WARRANTY - Please visit http:// bpeng.sony.co.kr/handler/BPAS-Start for important information and complete terms and conditions of Sony’s limited warranty applicable to this product.
7
Table of Contents Precaution ... 9 On Safety ... 9 On Installation ... 9 About the LCD Display Panel ... 9 On Burn-in ... 9 On a Long Period of Use ... 9 On Cleaning ... 9 Disposal of the Unit ... 10 Recommendation to Use more than One Unit ... 10 On Repacking ... 10 On Fan Error ... 10 On Moisture Condensation ... 10 Precautions for using this unit safely ... 10 Precautions for connecting this unit with other medical devices ... 10 On simultaneous use with a radio knife, etc. ... 11 Features ... 11 Location and Function of Parts and Controls ... 13 Front Panel ... 13 Input Signals and Adjustable/Setting Items ... 15 Rear/Bottom Panel ... 16 Connecting the AC Power Cord ... 18 Installing the Input Adaptor ... 19 Removing the Connector Cover ... 19 Selecting the Default Settings ... 20 Selecting the Menu Language ... 21 Using the Menu ... 22 Loading USER MEMORY ... 24 Adjustment Using the Menus ... 24 Items ... 24 Adjusting and Changing the Settings ... 25 STATUS menu... 25 COLOR TEMP/SPACE menu... 26 USER CONTROL menu... 26 USER CONFIG menu... 28 REMOTE menu ... 32 KEY INHIBIT menu... 33 USER MEMORY menu ... 33 Saving the user memory... 33 Troubleshooting ... 35 Specifications ... 35 Dimensions ... 43
8
Table of Contents
Precaution
the monitor becomes warm, the screen returns to normal. • The screen and the cabinet become warm during operation. This is not a malfunction.
On Safety • Operate the unit on 100-240 V AC only. • The nameplate indicating operating voltage, etc. is located on the AC adaptor. • Should any solid object or liquid fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it any further. • Unplug the unit from the wall outlet if it is not to be used for several days or more. • To disconnect the AC power cord, pull it out by grasping the plug. Never pull the cord itself. • The socket-outlet shall be installed near the equipment and shall be easily accessible.
On Installation • Prevent internal heat build-up allowing adequate air circulation. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation holes. • Do not install the unit near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive dust, mechanical vibration or shock. • Do not place the monitor near equipment which generates magnetism, such as a transformer or high voltage power lines.
About the LCD Display Panel • The LCD panel fitted to this unit is manufactured with high precision technology, giving a functioning pixel ratio of at least 99.99%. Thus a very small proportion of pixels may be “stuck”, either always off (black), always on (red, green, or blue), or flashing. In addition, over a long period of use, because of the physical characteristics of the liquid crystal display, such “stuck” pixels may appear spontaneously. These problems are not a malfunction. • Do not leave the LCD screen facing the sun as it can damage the LCD screen. Take care when you place the unit by a window. • Do not push or scratch the LCD monitor’s screen. Do not place a heavy object on the LCD monitor’s screen. This may cause the screen to lose uniformity. • If the unit is used in a cold place, a residual image may appear on the screen. This is not a malfunction. When
On Burn-in For LCD panel, permanent burn-in may occur if still images are displayed in the same position on the screen continuously, or repeatedly over extended periods. Images that may cause burn-in • Masked images with aspect ratios other than 16:10 • Color bars or images that remain static for a long time • Character or message displays that indicate settings or the operating state To reduce the risk of burn-in • Turn off the character displays Press the MENU button to turn off the character displays. To turn off the character displays of the connected equipment, operate the connected equipment accordingly. For details, refer to the operation manual of the connected equipment. • Turn off the power when not in use Turn off the power if the monitor is not to be used for a prolonged period of time.
On a Long Period of Use Due to the characteristics of LCD panel, displaying static images for extended periods, or using the unit repeatedly in a high temperature/high humidity environments may cause image smearing, burn-in, areas of which brightness is permanently changed, lines, or a decrease in overall brightness. In particular, continued display of an image smaller than the monitor screen, such as in a different aspect ratio, may shorten the life of the unit. Avoid displaying a still image for an extended period, or using the unit repeatedly in a high temperature/high humidity environment such an airtight room, or around the outlet of an air conditioner. To prevent any of the above issues, we recommend reducing brightness slightly, and to turn off the power whenever the unit is not in use.
On Cleaning Before cleaning Be sure to disconnect the AC power cord from the AC outlet.
Precaution
9
On cleaning the monitor A material that withstands disinfection is used for the front protection plate of the medical use LCD monitor. The protection plate surface is especially treated to reduce reflection of light. When solvents such as benzene or thinner, or acid, alkaline or abrasive detergent, or chemical cleaning cloth are used for the protection plate surface/monitor surface, the performance of the monitor may be impaired or the finish of the surface may be damaged. Take care with respect to the following: • Clean the protection plate surface/monitor surface with a 50 to 70 v/v% concentration of isopropyl alcohol or a 76.9 to 81.4 v/v% concentration of ethanol using a swab method. Wipe the protection plate surface gently (wipe using less than 1 N force). • Stubborn stains may be removed with a soft cloth such as a cleaning cloth lightly dampened with mild detergent solution using a swab method and then clean using the above chemical solution. Never use solvents such as benzene or thinner, or acid, alkaline or abrasive detergent, or chemical cleaning cloth for cleaning or disinfection, as they will damage the protection plate surface/monitor surface. • Do not use unnecessary force to rub the protection plate surface/monitor surface with a stained cloth. The protection plate surface/monitor surface may be scratched. • Do not keep the protection plate surface/monitor surface in contact with a rubber or vinyl resin product for a long period of time. The finish of the surface may deteriorate or the coating may come off.
Disposal of the Unit Do not dispose of the unit with general waste. Do not include the monitor with household waste.
Recommendation to Use more than One Unit As problems can occasionally occur for the monitor, when the monitor is used for safety control of personnel, assets or stable picture, or for emergencies, we strongly recommend you use more than one unit or prepare a spare unit.
On Repacking Do not throw away the carton and packing materials. They make an ideal container which to transport the unit. If you have any questions about this unit, contact your authorized Sony dealer.
10
Precaution
On Fan Error The fan for cooling the unit is built in. When the fan stops and the RETURN button on the front panel blinks for fan error indication, turn off the power and contact an authorized Sony dealer.
On Moisture Condensation If the unit is brought directly from a cold place to a warm place, or the unit is warm and the ambient temperature cools suddenly (by air-conditioning, for example), moisture may condense on the surface or inside of the unit, or create a mist residue inside the protection plate. This is called moisture condensation, and is not a malfunction of the product itself, although it may cause damage to the unit. Leave the unit in a condensation free area. If moisture condensation has occurred, turn off the unit and do not use it until moisture condensation has evaporated.
Precautions for using this unit safely • Some people may experience discomfort (such as eye strain, fatigue, or nausea) while watching video images. Sony recommends that all viewers take regular breaks while watching video images. The length and frequency of necessary breaks will vary from person to person. You must decide what works best. If you experience any discomfort, you should stop watching the video images until the discomfort ends; consult a doctor if you believe necessary. • Avoid watching the display in environments where your head may shake, or while you are walking or performing exercise, because there is a higher possibility that you experience discomfort.
Precautions for connecting this unit with other medical devices • Before you utilize this device and/or connect this device to any other medical device, please be aware of and abide by the following precautions: (a) Before actually using this device for medical practice, please check and confirm that you do not experience any discomfort in your use that could be disruptive or impeditive in conducting your intended activity or medical practice. (b) If you experience or are likely to experience such discomfort, please refrain from using this device. (c) Generally, discomfort (such as eye strain, fatigue,
nausea, or motion sickness) can be provoked by such factors as quick movements or shakiness of video picture, focal position of video pictures, distance between objects and image capturing modules, user’s point of gaze in video pictures, other varying conditions of video pictures to be input to this device, and individual user’s health conditions.
On simultaneous use with a radio knife, etc. If this unit is used together with a radio knife, etc., the picture may be disturbed, warped or otherwise abnormal as a result of strong radio waves or voltages from the device. This is not a malfunction. When you use this unit simultaneously with a device from which strong radio waves or voltages are emitted, confirm the effect of this before using such devices, and install this unit in a way that minimizes the effect of radio wave interference.
Features Compliance with medical safety standards in U.S.A., Canada and Europe IEC 60601-1 and product safety standards in the U.S.A., Canada and Europe have been obtained for this monitor. The monitor is designed for use in the medical treatment field, with the sheet switch, screen protect panel, etc.
Picture Fully digital 10-bit signal processing circuit As well as digital signals, all signals including analog signals are converted into digital signals. All signals are processed using a fully digital 10-bit processing circuit so that an image is produced in smooth gradation without any deterioration of quality. Two color system available The monitor can display NTSC and PAL signals by connecting this unit. Auto chroma/phase function The chroma and phase of the decoder are automatically adjusted with the auto chroma phase function. High image-quality/high-resolution WUXGA LCD panel An WUXGA high-resolution (1,920 × 1,200 dots) panel and high brightness/ultra-wide field of view technology enable you to use the monitor under various lighting conditions and in numerous ways (installing on wall, using several monitors to view an image, and so on.). Because a color filter with wide-color reproduction and LCD materials with high response speed are used, the motion picture of the video signal is displayed clearer. This monitor also performs sampling of signals at high frequencies and provides a high resolution of 700 TV scanning lines or more during the RGB or component signal (480/60I, 575/50I) input.
Input Accepts analog RGB input signals *1 Adopting the scan converter allows this monitor to detect VGA, SVGA, XGA and SXGA analog RGB signals input to the HD15 input connector. Accepts DVI-D (digital) input signals *1 Adopting the scan converter allows this monitor to detect VGA, SVGA, XGA and SXGA digital computer signals input to the DVI input connector.
Features
11
The number of the DVI input connectors can be increased by installing the optional input adaptor into the optional input port. To view more than SXGA signals when the DVI input is selected, use the cable within 3 m (118 1/8 inches) in length. *1
For acceptable formats, see “About the preset signal” on page 38.
Optional port Two optional input adaptors can be installed. The composite, Y/C, component, analog RGB, SDI or DVID signal can be input depending on the input connectors of the board to be used. SDI supports not only HD-SDI and SD-SDI, but also 3G-SDI, which transmits twice as much data as HD-SDI with a Single-link. Multi-format *2 NTSC or PAL color system or DTV format, such as 720P, 1080i, etc. can be selected automatically. *2
For acceptable formats, see “Available signal formats” on page 37.
External sync input The unit can be operated on the sync signal supplied from an external sync generator.
Functions APA (Auto Pixel Alignment) function You can display pictures from the HD15 input connector in the appropriate picture by simply pressing the APA key. Automatic termination (connector with mark only) The input connector is terminated internally at 75 ohms when nothing has been connected to the output connector. If a cable is connected to the output connector, the internal terminal is automatically released and the signals input to the input connector are output to the output connector (loop-through). Select color temperature and gamma mode You can select the color temperature from among three (HIGH, LOW, LOW2) settings and gamma mode from between two settings (2.2, DICOM). You can also adjust the color temperature to the appropriate setting in “USER”. Two-display Two kinds of input signals are put on the monitor. For more information, see MULTI DISPLAY of “MULTI DISPLAY SETTING” on page 29. Color space feature You can select ITU-R BT.709 for the color space settings.
12
Features
Aspect setting You can set the monitor to 4:3 or 16:9 display mode according to the input signal. Scan function You can select the display from among “NORMAL”, “OVER”, “FULL” and “NATIVE” except the HD15 and DVI input signals. Select language display You can select your language for the display from seven languages - English, French, German, Spanish, Italian, Japanese and Chinese. Power saving function The monitor enters into power saving mode to reduce the power consumption when no signal is input. Key inhibit function You can inhibit the key to prevent missing an operation. User memory function You can save the 20 picture settings with the name. The user memory data can be saved or loaded between the monitor and the equipment (PC, etc.) connected in serial remote mode. Two kinds of ground terminals Two kinds of ground terminals are built into the monitor to equal the electric potential. External remote function The input signal is selected or various items are adjusted by use of the serial (Ethernet) remote function. You can connect this unit to the monitor by the Ethernet (10BASE-T/100BASE-TX) connection and controlled remotely on the network. For more information, see SERIAL REMOTE of REMOTE menu on page 32.
Other Optional stand It is more convenient to install the monitor on a desk by using the optional stand (SU-560).
Location and Function of Parts and Controls Front Panel
1 2 3 4
COMPOSITE
Y/C
RGB COMPONENT
+
0
A-1
– A-2
B-1
B-2
HD15
DVI
+ – + – + –
5 6 7 8
F1
qa
F2
+ F3
–
9
F4
qs
USER MEM
a Tally lamp You can check the status of the monitor by the color of the tally lamp. The tally lamp lights in green according to the setting of PARALLEL REMOTE in the REMOTE menu. b Power indicator When the power is turned on, the power indicator light in green. c - (key inhibit) indicator Lights in green when KEY INHIBIT in the KEY INHIBIT menu is set to ON. d CONTROL button Press to display the buttons on the front panel. Press again to clear the display. e CONTRAST buttons Adjusts the picture contrast. Press the + button to make the contrast higher or the – button to make it lower. f PHASE buttons Adjusts color tones. Press the + button to make the skin tones greenish or the – button to make them purplish. g CHROMA buttons
Adjusts the color intensity. Press the + button to increase the color intensity or the – button to decrease it. h BRIGHT (brightness) buttons Adjusts the picture brightness. Press the + button to increase the brightness or the – button to decrease it. i Menu operation buttons Displays or sets the on-screen menu. MENU button Press to display the on-screen menu. Press again to clear the menu. +/– buttons Press to select the items and setting values. ENTER button Press to confirm a selected item on the menu. When the menu is not displayed and the button is pressed, the distinguished signal format is displayed. RETURN button When the menu is displayed and the button is pressed, the value of an item is reset to the previous value. When the menu is not displayed and the button is pressed, the function selected in FUNCTION BUTTON SETTING of the USER CONFIG menu is displayed on the side of the F1 to F4 button. Also, when the fan stops, this button blinks.
Location and Function of Parts and Controls
13
j Input select buttons Press the button to monitor the signal input to each connector. A-1, A-2, B-1 and B-2 buttons are used when an optional input adaptor has been installed in the option port. COMPOSITE button: to monitor the signal through the COMPOSITE IN connector Y/C button: to monitor the signal through the Y/C IN connector RGB button: to monitor the RGB signal through the connectors for the R/G/B signal input COMPONENT button: to monitor the component signal through the connectors for Y/PB/PR signal input A-1 button: to monitor the signal from connector 1 of the input adaptor installed in the option port A or R/ G/B signal from BKM-229X/BKM-256DD installed in the option port A A-2 button: to monitor the signal from connector 2 of the input adaptor installed in the option port A or Y/ PB/PR signal from BKM-229X/BKM-256DD installed in the option port A B-1 button: to monitor the signal from connector 1 of the input adaptor installed in the option port B or R/ G/B signal from BKM-229X/BKM-256DD installed in the option port B B-2 button: to monitor the signal from connector 2 of the input adaptor installed in the option port B or Y/ PB/PR signal from BKM-229X/BKM-256DD installed in the option port B HD15 button: to monitor the signal through the HD15 input connector DVI button: to monitor the signal through the DVI-D input connector k Function buttons You can turn the assigned function on or off. The factory setting is as follows; F1 button: EXT SYNC F2 button: SCAN F3 button: ASPECT F4 button: MULTI DISPLAY You can assign the function from among SCAN, ASPECT, EXT SYNC, BLUE ONLY, MONO, MULTI DISPLAY, APA, I/P MODE and MIRROR IMAGE in FUNCTION BUTTON SETTING of the USER CONFIG menu (see page 30). For details of the function assigned to the function button, see page 30. l USER MEM (user memory) button Press to load the picture settings saved in the USER MEMORY menu (on page 33).
14
Location and Function of Parts and Controls
Input Signals and Adjustable/Setting Items Video*3,
Item
B & W*3
Y/C*3 CONTRAST*1 BRIGHT*
1
CHROMA*1 PHASE*
1
Component*4
Input signal RGB*4
SDI
Computer
SD
HD
SD
HD
SD*5
HD*6 3G*14
DVI*13
HD15
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
× ×
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a (NTSC)
APERTURE
a
a
a
a
a
a
a
a
a
a
a
COLOR TEMP
a
a
a
a
a
a
a
a
a
a
a
COLOR SPACE
a
a
a
a
a
a
a
a
a
a
a
AUTO CHROMA/ PHASE
a
×
a
a
×
×
×
×
×
×
×
ACC
a
×
CTI
a
× ×
a
× ×
a
a
a
a
× ×
× ×
a a (480/60I)
× ×
× × × × ×
× ×
a
× × × × ×
× ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
×
×
×
×
×
×
×
×
×
V SHARPNESS MATRIX*
2
COMPONENT LEVEL NTSC SETUP SCAN GAMMA 10
a a (NTSC) (480/60I) a
a
a
a
a
a
a
a
a
×*8
×*8
a
a
a
a
a
a
a
a
a
a
a
*12
×*12 × ×
ASPECT*
a
a
a
×
a
×
a
×
×
BLUE ONLY
a
a
a
a
a
a
a
a
MONO
a
a
a
a
SIZE
× ×
× ×
× × ×
a
× ×
× × ×
a
APA
× × × ×
× ×
× ×
× ×
SHIFT
a
a
a
a
a
a
a
a
a
PITCH DOT PHASE
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× × × × × × × ×
POWER SAVING
a
a
a
a
a
a
a
a
a
a
a
×
*8
×*8
I/P MODE*
7
MULTI DISPLAY
a
a
a
a
a
a
a
a
a : Adjustable/can be set × : Not adjustable/cannot be set *1 Adjustment of SUB CONTROL is the same. *2 When a component signal (480/60I or 480/60P) is input and the COMPONENT LEVEL is set to SMPTE, this can be switchable. *3 When a BKM-227W is installed, the number of the input connector is increased. *4 When a BKM-229X is installed, the number of the input connector is increased. *5 When a BKM-220D, BKM-243HSM or BKM-250TGM is installed, the signal can be input.
a
a
a
a
×
a*11 a a a a
a a a a a a*9 a* 9 *6 When a BKM-243HSM or BKM-250TGM is installed, the signal can be input. *7 Only the interlace signal is input. *8 The signal can operate with PRESET 2 to 6 (see page 38). *9 For details on the input signal available for the multi display, see “For the multi display” (page 40). *10 The signal cannot operate with PRESET 7 and 8 (see page 38). *11 The signal can only operate with PRESET 1 (see page 38). *12 The signal can only operate with PRESET 6 (see page 38). *13 When a BKM-256DD is installed, the number of the input connector is increased. *14 When a BKM-250TGM is installed, the signal can be input.
Location and Function of Parts and Controls
15
Rear/Bottom Panel
1
2 3 4567
8
9
0
qa
a
qg
qh
/I (Equipotential/Function Earth) terminal (equipotential) terminal Connects the equipotential plug. I (function earth) terminal Connects the earth cable.
To use the external sync signal, press the function button that EXT SYNC is assigned (F1 button at the factory setting).
b COMPOSITE IN connector (BNC) Input connector for composite signals.
When inputting a video signal with the jitters, etc. the picture may be disturbed. We recommend using the TBC (time base corrector).
c Y/C IN connector (4-pin mini-DIN) Input connector for Y/C signals. d G/Y IN connector (BNC) Input connector for G of RGB signals and component Y (luminance) signals. e B/PB IN connector (BNC) Input connector for B of RGB signals and PB (blue color difference) of component signals. f R/PR IN connector (BNC) Input connector for R of RGB signals and PR (red color difference) of component signals. g EXT SYNC IN (external sync input) connector (BNC) When this unit operates on an external sync signal, connect the reference signal from a sync generator to this connector.
16
qs qd qf
Location and Function of Parts and Controls
Note
h Loop-through output connectors Outputs the signals input to the input connectors (2 to 7). Connect to the analog input (composite, Y/C, analog component, analog RGB or external sync) of equipment, according to the input signal. When a cable is connected to one of these connectors, the 75-ohm termination of the corresponding input is automatically released, and the signal input to the input connector is output. i DC 5V/24V IN connector Connect the DC connector of the supplied AC adaptor. j Optional input port An optional input adaptor can be installed according to your system configuration (see page 19). The left side port is A and the right side port is B. Press the A-1, A-2, B-1 or B-2 button to select the signal.
k / (power) switch The power is turned on or off. The monitor is turned on by pressing side
.
l PARALLEL REMOTE connector (modular connector, 8-pin) Forms a parallel switch and controls the monitor externally. When the unit is shipped from the factory, a connector cover is attached to this connector. Remove it before using the connector.
o DVI-D input connector (DVI-D) Inputs DVI Rev.1.0 applicable digital RGB signal. To view the signals of the SXGA and higher resolution when the DVI input is selected, use the cable within 3 m (118 1/8 inches) in length. p HD15 input connector (D-sub 15 pin, female) Inputs an analog RGB video signal (0.7 Vp-p, positive polarity) and sync signal. The Plug & Play function corresponds to DDC2B.
For removing the connector cover, see page 19. For details on the pin assignment and factory setting function assigned to each pin, see page 37. CAUTION For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port. m SERIAL REMOTE connector (RJ-45) Connect to the network by using a 10BASE-T/ 100BASE-TX LAN cable (shielded type, optional). When the unit is shipped from the factory, a connector cover is attached to this connector. Remove it before using the connector. For removing the connector cover, see page 19. For details on this connector, refer to the Interface Manual for Programmers (saved in the supplied CDROM, Japanese and English only.) CAUTION • When an optional LAN cable is connected, use a shield type cable to prevent miss-operation due to noises. • For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port. • The connection speed may be affected by the network system. This unit does not guarantee the communication speed or quality of 10BASE-T/ 100BASE-TX. n SERIAL REMOTE RS-232C connector (D-sub 9-pin, female) Connect to the RS-232C control connector on external equipment connected to the monitor. The monitor can be operated according to control commands sent from external equipment connected to it. For details on the pin assignment and factory setting function assigned to each pin, see page 37. For details on this connector, refer to the Interface Manual for Programmers (saved in the supplied CDROM, Japanese and English only.)
Location and Function of Parts and Controls
17
3
Connecting the AC Power Cord
Insert the DC IN connector into the DC 5V/24V IN connector on the bottom of this unit until it locks.
Connect the supplied AC power cord as illustrated. Two kinds of AC plug holders are supplied with this unit. Use the AC plug holder that fits the AC power cord most securely.
1
Plug the AC power cord into the AC IN socket on the AC adaptor. Then, attach the AC plug holder to the AC power cord. AC IN socket
To remove the AC power cord AC power cord
AC plug holder (Supplied)
2
18
Slide the AC plug holder over the cord until it locks.
Connecting the AC Power Cord
First, pull out the AC plug holder while pressing the lock levers. Next, pull out the DC IN connector from the DC 5V/24V IN connector while pressing the lock lever.
Installing the Input Adaptor
Removing the Connector Cover
Before installing the input adaptor, disconnect the power cord.
When the unit is shipped from the factory, a connector cover is attached to the PARALLEL REMOTE connector and the SERIAL REMOTE connector (RJ45). To use the connector, remove the connector cover as follows. Before removing the connector cover, disconnect the power cord.
1
Remove the panel of the optional input port.
Connector cover
2
Insert the input adaptor into the port.
PARALL EL
REMOTE
SERIAL
REMOTE
1
Remove the screw of the connector cover.
2
Remove the connector cover.
Save the screw and cover, so that you can reattach the cover if necessary.
3
Tighten the screws.
Caution
These connectors are designed to allow direct contact with conductive circuits. Weak voltage may be present because of a failure in this unit. To prevent patients from touching these connectors accidentally, attach the connector covers when the connectors are not being used to connect to other devices.
Installing the Input Adaptor / Removing the Connector Cover
19
Selecting the Default Settings
2 +
When you turn on the unit for the first time after purchasing it, select the area where you intend to use this unit from among the options.
– + – + – +
The default setting values for each area
–
+
+
–
–
3 1
5 4 3
3~4
1 1
2 3
Turn on the unit with the the bottom panel.
/
(power) switch on
The SELECT SETTING screen appears. COLOR TEMP
1 NORTH
LOW
AMERICA
COMPONENT LEVEL BETA7.5
NTSC SETUP 7.5
2 LATIN AMERICA
ARGENTINA
LOW
SMPTE
0
PAL&PAL-N AREA
PARAGUAY
LOW
SMPTE
0
URUGUAY
LOW
SMPTE
0
NTSC&PAL-M AREA
OTHER AREA
LOW
BETA7.5
7.5
LOW
SMPTE
0
3 AFRICA AUSTRALASIA EUROPE MIDDLE-EAST
4 ASIA EXCEPT
NTSC AREA
LOW
BETA7.5
7.5
JAPAN
PAL AREA
LOW
SMPTE
0
HIGH
SMPTE
0
5 JAPAN
1 North America S E L EC T S E T T I NG NOR T H AMER I CA L A T I N AMER I CA A F R I C A A U S T R A L A S I AE AS I A EXCEPT J APAN J APAN
2 Latin America 3 Africa Australia/New Zealand, Europe, Middle East, Russia
4 Asia Except Japan 5 Japan
2
Press the CONTROL button.
3
Press the + or – button to select the area where you intend to use the unit and press the ENTER button. If you select either 1, 3 or 5 The confirmation screen is displayed. Confirm the selected area. When the setting is wrong, press the RETURN button to return to the previous screen.
SELECT THIS AREA? NORTH AMERICA [ E NT E R ]Y E S [ R E T U R N ] NO
If you select either 2 or 4 One of the following screens appears. Press the + or – button to narrow the area further and then press the ENTER button. The confirmation screen is displayed. Confirm the selected area. When the setting is wrong, press the RETURN button to return to the previous screen.
20
Selecting the Default Settings