Stryker
Beds, Chairs, Stretchers and Stools
Power-PRO TL Ref 6550 Operations and Maintenance Manual Rev A
Operations and Maintenance Manual
151 Pages
Preview
Page 1
Power-PRO™ TL Model 6550
Operations/Maintenance Manual
For parts or technical assistance: USA: 1-800-327-0770 UK: +44 (0) 1635 262431 2010/06
6550-309-001 REV A
www.stryker.com
Table of Contents Symbols and Definitions ... 6 Symbols... 6 Warning/Caution/Note Definition ... 7 Introduction... 8 Product Description ... 8 Intended Use of Product... 8 Specifications... 9 Contact Information ... 11 Serial Number Location... 11 Product Illustration ... 12 Summary of Safety Precautions... 13 Pinch Points... 17 Setup Procedures... 18 Product Inspection... 19 Cot Fastener Installation ... 21 Engaging the Cot into the Fastener... 23 Removing the Cot from the Fastener... 24 Operation Guide ... 25 Operating Guidelines ... 25 Proper Lifting Techniques... 25 Transferring the Patient to the Cot... 26 Rolling the Cot... 26 Adjusting The Height of the Cot with Two Operators... 27 Tail Lift Loading and Unloading ... 28 Ramp Loading and Unloading... 29 Loading and Unloading the Cot Using the Optional Oxygen Bottle Holder... 30 High Speed Retract/Extend... 31 Using the Manual Override... 32 Using Additional Assistance ... 33 Removing and Replacing the Battery... 34 Removing and Replacing a SMRT Pak... 34 Removing and Replacing a DeWALT® Battery... 35 Using the Battery Power Indicator... 36 Using the Hour Meter ... 37 Using Restraint Straps ... 38 Using the Optional Restraint Belt Extension... 40 Operating the Backrest... 41 Operating the Siderails... 41 Operating the Retractable Head and Foot Sections ... 42 Adjusting the Footrest... 43 Operating the Wheel Lock(s)... 44 Operating the Caster Steer Lock... 45
www.stryker.com
6550-309-001 REV A
3
Table of Contents Installing the Push Bars ... 46 Removing the Push Bars... 46 Attaching the Push Bar Storage Pouch ... 46 Operating the Optional 2-Stage I.V. Pole ... 47 Operating the Optional 3-Stage I.V. Pole ... 48 Optional Accessories... 49 Using the Equipment Hook ... 50 Attaching the Pedi-Mate® Infant Restraint System ... 51 Installing the Backrest Storage Pouch... 53 Using the Oxygen Bottle Holder... 54 Cleaning... 55 Washing Procedure... 55 Washing Limitations ... 55 Removal of Iodine Compounds ... 56 Preventative Maintenance ... 57 Lubrication... 57 Regular Inspection and Adjustments ... 58 Maintenance Record... 60 Training Record... 61 Troubleshooting Guide... 62 Electronics and Hydraulics Locator... 62 Hydraulic Manifold Components Locator ... 63 Electrical System Block Diagram ... 64 Troubleshooting Guide ... 66 Main Cable Assembly... 69 Electronics Assembly ... 69 Electronics Assembly Wiring Schematics... 70 Quick Reference Replacement Parts List... 71 Service Information... 73 Accessing the Hydraulic Sub-Assembly (6550-001-030)... 73 Manual Release Cable Adjustment ... 74 Filling the Reservoir ... 74 Wheel Locking Force Adjustment ... 75 Cot Assembly ... 76 Base Assembly... 85 Inner Lift Tube Assembly, Litter Pivot, Right - 6550-001-034... 91 Inner Lift Tube Assembly, Litter Pivot, Left - 6550-001-035... 92 Caster, Steer Lock, Wheel Lock Assembly... 93 Hitch Assembly, Head End... 94 Outer Rail, Right... 97 Outer Rail, Left... 98 Mounted Hydraulics Assembly... 99 Hydraulics Sub-Assembly ... 101 Hitch Assembly, Foot End ... 103 4
6550-309-001 REV A
www.stryker.com
Table of Contents Telescoping Foot End - 6550-001-015 ... 107 Telescoping Head Section - 6550-001-020... 109 Fowler Assembly... 111 Gatch Assembly ... 112 Gatch Telescoping Assembly - 6550-001-017... 115 No I.V. Pole Assembly Option... 116 2-Stage I.V. Pole, Right - 6550-210-000 ... 117 2-Stage I.V. Pole Assembly, Right - 6500-001-041... 118 2-Stage I.V. Pole, Left - 6550-211-000 ... 119 2-Stage I.V. Pole Assembly, Left - 6500-001-042 ... 120 2-Stage I.V. Pole, Dual - 6550-212-000... 121 3-Stage I.V. Pole, Right - 6550-215-000... 122 3-Stage I.V. Pole Assembly, Right - 6500-001-043 ... 123 3-Stage I.V. Pole, Left - 6550-216-000... 124 3-Stage I.V. Pole Assembly, Left - 6500-001-044 ... 125 3-Stage I.V. Pole, Dual - 6550-217-000... 126 Optional Push Bar - 6550-040-000 ... 127 Optional Corner Handle Assembly... 128 Label, SMRT Power... 129 Label, DeWALT®... 130 Optional Accessories... 131 Equipment Hook - 6500-147-000 ... 132 Oxygen Bottle Holder - 6550-002-020 ... 133 Removable Oxygen Bottle Holder - 6080-140-000 ... 134 Defibrillator Platform - 6100-170-000 ... 135 Backrest Pouch - 6500-130-000... 136 Recycling Passport... 137 EMC Information... 144 Warranty... 148 Stryker EMS Return Policy ... 149 Return Authorization... 149 Damaged Merchandise... 149 International Warranty Clause... 149 Patent Information... 149
www.stryker.com
6550-309-001 REV A
5
Symbols and Definitions SYMBOLS Warning, consult accompanying documentation
Safe Working Load Symbol
Dangerous Voltage Symbol
Pinch Point
Extend
Retract Type B Equipment: equipment providing a particular degree of protection against electric shock, particularly regarding allowable leakage current and reliability of the protective earth connection. Internally Powered Equipment: Equipment able to operate from an internal (removable) electric power source.
IPX6
Mode of Operation: 10% (33 Sec. On / 5 Min. Off) Protection from powerful jets of water Medical Equipment Classified by Underwriters Laboratories Inc. With Respect to Electric Shock, Fire, and Mechanical Hazards Only in Accordance with UL 60601−1, First Edition (2003) and CAN/CSA C22.2 No. 601.1-M90 with updates 1 and 2. In accordance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment, this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately. Refer to your local distributor for return and/or collection systems available in your country. BS EN 1789:2000 Certified
Return To Table of Contents 6
6550-309-001 REV A
www.stryker.com
Symbols and Definitions WARNING/CAUTION/NOTE DEFINITION The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.
WARNING Alerts the reader about a situation which, if not avoided, could result in death or serious injury. It may also describe potential serious adverse reactions and safety hazards.
CAUTION Alerts the reader of a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. This includes special care necessary for the safe and effective use of the device and the care necessary to avoid damage to a device that may occur as a result of use or misuse.
NOTE Provides special information to make maintenance easier or important instructions clearer.
Return To Table of Contents www.stryker.com
6550-309-001 REV A
7
Introduction This manual is designed to assist you with the operation and maintenance of the Power-PRO™ TL cot. Carefully read this manual thoroughly before using the equipment or beginning maintenance on it. To ensure safe operation of this equipment, it is recommended that methods and procedures be established for educating and training staff on the safe operation of this cot.
PRODUCT DESCRIPTION The Model 6550 Power-PRO™ TL powered cot reduces manual lifting. The battery-powered hydraulic system raises and lowers the patient with the touch of a button and the retractable head section and foot section shorten the cot for 360-degree mobility in any height position.
INTENDED USE OF PRODUCT The Stryker Model 6550 Power-PRO™ TL ambulance cot is a wheeled device which consists of a platform mounted on a wheeled frame that is designed to support patients in a horizontal position. The device has siderails and has the option available to support the temporary or permanent placement of I.V. poles. An ambulance cot provides the operator a method of transporting patients from a location, typically outside of a healthcare facility, to another location via an ambulance. The cots are intended for transportation purposes and are not intended to be used as hospital stretchers or beds.
Return To Table of Contents 8
6550-309-001 REV A
www.stryker.com
Introduction SPECIFICATIONS Safe Working Load Note: Safe Working Load indicates the 50 stones sum of the patient, mattress and accessory weight.
318 kg
Maximum Unassisted Lift Capacity Backrest Articulation/Shock Position Overall Length Standard Length/Minimum Length/Width Height1
50 stones 318 kg 0° to 75° / +15° 206 cm 194.3 cm / 139.7 cm / 58 cm Adjustable from 36 cm to 106 cm
Weight2 Caster Diameter/Width Minimum Operators Required for Loading/ Unloading an Occupied Cot Minimum Operators Required for Loading/ Unloading an Unoccupied Cot Recommended Fastener Systems Double Wheel Lock / Four Wheel Lock Hydraulic Oil Power System3 - Battery
10.35 stones 15 cm / 5 cm 2
- Charger Standards (Cots and Chargers)
66 kg
700 lb
700 lb 81 in 76.5 in / 55 in / 23 in Adjustable from 14 in to 41.5 in 145 lb 6 in / 2 in
1 Model 6385, 6386, 6387, 6388, or 6389 Double Wheel Lock Standard/Four Wheel Lock Optional Stryker Part Number 6500-001-293 24V DC NiCd - SMRT™ Power System 24V DC NiCd - DeWALT® Battery System 120V/240Vac or 12V DC - SMRT™ Power System 120V/240Vac or 12V DC - DeWALT® Battery System IEC 60601-1 CAN/CSA-C22.2 No. 601.1-M90 UL 60601-1 IEC 60601-1-2:2001 BS EN 1789
Height measured from bottom of mattress at seat section to ground level. Cot is weighed with 1 battery and without mattress and restraints. 3 Cot is compatible with the SMRT™ Power System and DeWALT® Battery System. Stryker reserves the right to change specifications without notice. The Power-PRO™ TL is designed to be compatible with competitive cot fastener systems. DeWALT® is a registered trademark of Black & Decker Inc. Patents pending. 1 2
The yellow and black color scheme is a proprietary trademark of Stryker Corporation.
Return To Table of Contents www.stryker.com
6550-309-001 REV A
9
Introduction SPECIFICATIONS (CONTINUED) Environmental Conditions
Operation
130 0F (54 0C)
Temperature
-30 0F (-34 0C)
100% Relative Humidity
0%
Atmospheric Pressure
Return To Table of Contents 10
6550-309-001 REV A
www.stryker.com
Introduction CONTACT INFORMATION Contact Stryker Customer Service or Technical Support at: +44 (0) 1635 262431. Stryker UK Limited Hambridge Rd. Newbury, Berkshire RG14 5EG, England Please have the serial number (see Figure 1) of your Stryker product available when calling Stryker Customer Service or Technical Support. Include the serial number in all written communication.
SERIAL NUMBER LOCATION
Serial Number
HEAD END
Figure 1: Cot Serial Number & Location
Return To Table of Contents www.stryker.com
6550-309-001 REV A
11
Introduction PRODUCT ILLUSTRATION
Backrest
Push Bars (Optional)
Gatch/Leg Rest
Backrest Adjustment Handle
Siderail Release Retractable Head Section
Retractable Foot Section
Lifting Bar Hydraulic Unit Height Adjustment Switch
Battery
Head Section Release
Steer Lock
Wheel Lock
Casters
Figure 2: Cot Components
Return To Table of Contents 12
6550-309-001 REV A
www.stryker.com
Summary of Safety Precautions Carefully read and strictly follow the warnings and cautions listed on these pages. Service only by qualified personnel.
WARNING • • •
• • • • • • • •
• • • • • • • • • •
• • •
• • •
Improper usage of the cot can cause injury to the patient or operator. Operate the cot only as described in this manual. Do not modify the cot or any components of the cot. Modifying the product can cause unpredictable operation resulting in injury to the patient or operator. Modifying the product also voids its warranty (see page 148). It is the responsibility of the cot operator to ensure that the cot being used in the Stryker Cot Fastener Systems meets the installation specifications listed on page 22. Injury may result if a non-compatible cot is used in the Stryker Fastener System. Do not attempt to operate the cot when it is loaded into a cot fastener. Entanglement in powered cot mechanisms can cause serious injury. Operate the cot only when all persons are clear of the mechanisms. Practice changing height positions and loading the cot until operation of the product is fully understood. Improper use can cause injury. Do not allow untrained assistants to assist in the operation of the cot. Untrained technicians/assistants can cause injury to the patient or themselves. Ensure proper hand placement on hand grips. Do not ride on the base of the cot. Damage to the product could occur, resulting in injury to the patient or operator. Transporting the cot sideways can cause the cot to tip, resulting in possible damage to the product and/or injury to the patient or operator. Transporting the cot in a lowered position, head or foot end first, minimizes the potential of a cot tip. Grasping the cot improperly can cause injury. Keep hands, fingers and feet away from moving parts. To avoid injury, use extreme caution when placing your hands and feet near the base tubes while raising and lowering the cot. Always use all restraint straps to secure the patient on the cot. An unrestrained patient may fall from the cot and be injured. Never leave a patient unattended on the cot or injury could result. Hold the cot securely while a patient is on the product. Never apply the wheel lock(s) while a patient is on the cot. Tipping could occur if the cot is moved while the wheel lock is applied, resulting in injury to the patient or operator and/or damage to the cot. Siderails are not intended to serve as a patient restraint device. See page 38 for proper restraint strap usage. Failure to utilize the siderails properly could result in patient injury. A minimum of two operators are required to transport a patient on the cot. In addition to the head and foot end, larger patients may require additional operators. Hydraulically raising or lowering the cot may temporarily affect electronic patient monitoring equipment. For best results, patient monitoring should be conducted when the cot is idle. High obstacles, such as curbing, steps or rough terrain, can cause the cot to tip, possibly causing injury to the patient or operator. Transporting the cot in lower positions reduces the potential of a cot tip. If possible, obtain additional assistance or take an alternate route. A lift gate stop which is not properly functioning can result in injury to the patient or operator; ensure that the cot is unable to roll back off of the lift before using the lift with a cot and patient. Verify the lift gate stop is maintained and functioning properly and ensure that the cot is secure at all times when on the tail lift. Whenever the weight of the cot and patient is off of the wheels, the cot will automatically enter the high speed retract mode if the retract (–) button is pressed. Once the weight is off of the ground, the operator(s) must support the load of the patient, cot and any accessories. Failure to support the load properly may cause injury to the patient or operator. To avoid risk of electric shock, never attempt to open the battery pack for any reason. If the battery pack case is cracked or damaged, do not insert it into the charger. Return damaged battery packs to a service center for recycling. Do not remove the battery when the cot is activated. Avoid direct contact with a wet battery or battery enclosure. Contact may cause injury to the patient or operator. Always use all restraint straps to secure the patient on the cot. An unrestrained patient may fall from the cot and be injured. Return To Table of Contents
www.stryker.com
6550-309-001 REV A
13
Summary of Safety Precautions WARNING (CONTINUED) • •
• • • • • •
• •
• •
•
Do not attach restraints to the base or cross tubes, improper restraint attachment could result in damage to the cot further resulting in injury to the patient or operator. Never install or use a wheel lock on a cot with excessively worn wheels. Installing or using a wheel lock on a wheel with less than a 6 in diameter could compromise the holding ability of the wheel lock, possibly resulting in injury to the patient or operator and/or damage to the cot or other equipment. Ensure that the push bar is properly locked into its mount to prevent the bar from coming out during use and possibly injuring the operator and/or patient. Do not lift the cot with the push bars. Lifting the cot by the push bars may result in failure of the push bar lock mechanism and may injure the operator and/or patient. When not in use, store the push bars in the base storage pouch that is provided with the push bar option. To avoid accidental release of the Pedi-Mate®, and possible injury to the infant, ensure that the restraint buckle is located away from obstructions on the cot or accessories. Use of power washing equipment can aerate contamination collected during the use of the cot. Use any appropriate personal safety equipment (goggles, respirator, etc.) to avoid the risk of inhaling contagion. SOME CLEANING PRODUCTS ARE CORROSIVE IN NATURE AND MAY CAUSE DAMAGE TO THE PRODUCT IF USED IMPROPERLY. If the products described above are used to clean Stryker EMS equipment, measures must be taken to insure the cots are wiped with clean water and thoroughly dried following cleaning. Failure to properly rinse and dry the cots will leave a corrosive residue on the surface of the cots, possibly causing premature corrosion of critical components. Failure to properly clean or dispose of contaminated mattress or other cot components will increase the risk of bloodborne pathogens and may cause injury to the patient or operator. Escaping fluid under pressure can penetrate the skin causing serious injury. Avoid the hazard by relieving pressure before disconnecting hydraulic or other lines. Tighten all connections before applying pressure. If an accident occurs, see a doctor immediately. Any fluid injected into the skin must be surgically removed within a few hours or gangrene may result. Doctors unfamiliar with this type of injury should reference a knowledgeable medical source. To avoid the risk of injury, do not use bare hands to check for hydraulic leaks. Medical electrical equipment requires special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided on page 144 to prevent equipment malfunction. Portable and mobile RF communication equipment can affect Medical Electrical Equipment. Explosion Hazard - Do not use cot in presence of flammable anesthetics.
CAUTION • •
• • • • • • • • •
When charging a battery in an ambulance, locate the charger in an enclosed cabinet and out of patient reach during transport. The unit must be in its lowest position to properly engage the cot fastener (not included). To ensure that the cot is in the lowest position, press the retract (-) button until the cot stops moving down. This should be done before attempting to engage the cot into the cot fastener (not included). To reduce the risk of damage to the cot or cot fastener, do not attempt to activate the cot height activation while it is engaged in the cot fastener (not included). Before operating the cot, clear any obstacles that may interfere and cause injury to the operator or patient. Remove the battery if the cot is not going to be used for an extended period of time (more than 24 hours). Only use the battery and charger as specified. The cot is not for use with an AC adapter. Ensure that the battery is fully charged prior to placing into service. An uncharged or depleted battery may cause poor cot performance. Ensure that the restraints are not entangled in the base frame when raising and lowering the cot. Never operate the cot with the head section or foot section in an unlocked position. Wheel lock(s) are only intended to help prevent the cot from rolling while unattended and to aid in patient transfer. A wheel lock may not provide sufficient resistance on all surfaces or under loads.
Return To Table of Contents 14
6550-309-001 REV A
www.stryker.com
Summary of Safety Precautions CAUTION (CONTINUED) • • • • • • • • • • • • • • • • •
•
• • • • •
• •
Engaging the steer lock and attempting to push the cot sideways may affect the cot stability. To avoid damage to the I.V. pole, the weight of the I.V. bags or equipment must not exceed 2.8 stones (18 kg) (40 lb). To avoid damage to the equipment hook, the weight of the accessories or equipment must not exceed 2.5 stones (16 kg) (35 lb). To avoid damage to the equipment hook, remove all accessories or equipment from the hook while transporting the stretcher in the ambulance. Do not store items under the cot mattress. Storing items under the mattress can interfere with the operation of the cot. The weight of the equipment in the pocketed backrest storage pouch (if equipped) must not exceed 1.4 stones (9 kg) (20 lb). Ensure that the storage pouch does not interfere with the operation of the retractable head section. To avoid damage to the oxygen bottle holder (if equipped), the weight of the equipment must not exceed 2.9 stones (18 kg) (40 lb). Only use oxygen bottles which lie within the width of the cot and are large enough to be firmly held by the straps. DO NOT STEAM CLEAN OR ULTRASONICALLY CLEAN THE UNIT. Maximum water temperature should not exceed 82°C/180°F. Maximum air dry temperature (cart washers) is 115°C/240°F. Maximum water pressure should not exceed 130.5 bar/1500 psi. If a hand held wand is being used to wash the unit, the pressure nozzle must be kept a minimum of 61 cm (24 inches) from the unit. Towel dry all casters and interface points. Failure to comply with these instructions may invalidate any/all warranties. Always remove the battery before washing the cot. A preventative maintenance program should be established for all Stryker EMS equipment. Preventative maintenance may need to be performed more frequently based on the usage level of the product. Close attention should be given to safety features including, but not limited to: • Hydraulic power mechanism • All electrical controls return to off or neutral position when released For additional maintenance information, see the preventative maintenance information. Improper maintenance can cause injury or damage to the product. Maintain the cot as described in this manual. Use only Stryker approved parts and maintenance procedures. Using unapproved parts and procedures could cause unpredictable operation and/or injury and will void the product warranty (see page 148). Failure to use authorized parts, lubricants, etc. could cause damage to the cot and will void the warranty of the product. Hydraulic lines, hoses, and connections can fail or loosen due to physical damage, kinks, age, and exposure. Check hoses and lines regularly to avoid damage to the cot. Check and tighten loose connections. Do not tip the cot and actuate the product as this will allow air to enter the hydraulic system. Do not lubricate the bearings in the X-frame as it will degrade the performance of the cot and may void its warranty (see page 148). The weight of the monitoring equipment must not exceed 5.4 stones (34 kg) (75 lb) on the defibrillator platform (if equipped). Monitoring equipment should not be stored on the cot or on the defibrillator platform when in the ambulance vehicle. To avoid malfunction, do not use the unit adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, observe the unit to verify normal operation in the configuration in which it will be used. Possible fire hazard when used with oxygen administering equipment of other than the nasal, mask or 1/2 bed length tent type. Oxygen tent should not extend below mattress support level. An oxygen rich environment is an environment where the oxygen concentration levels are greater than 25% for ambient pressures up to 110 kPa or the partial pressure of oxygen is greater than 27.5 kPa at ambient pressures exceeding 110 kPa.
Return To Table of Contents www.stryker.com
6550-309-001 REV A
15
Summary of Safety Precautions NOTE • • •
• • • • • •
•
Loose items or debris on the patient compartment floor can interfere with the operation of the cot fastener. Keep the patient compartment floor clear. This manual should be considered a permanent part of the cot and should remain with the product even if the cot is subsequently sold. Stryker continually seeks advancements in product design and quality. Therefore, while this manual contains the most current product information available at the time of printing, there may be minor discrepancies between your cot and this manual. If you have any questions, please contact Stryker Customer Service or Technical Support at +44 (0) 1635 262431. The operators must lift the cot weight slightly off of the wheels to use the manual extend or retract while a patient is on the cot. Activation of the manual back-up release handle may cause the cot to drop slowly if less than 7 stones (45 kg) (100 lb) are on the cot. Batteries slowly lose charge when not on the charger. Lowering the backrest without a patient may require slightly more pressure. When engaging the cot into the fastener, it is advised to disengage the caster steer lock feature to allow the head end casters to swivel freely and allow the head end of the cot to more easily align with the fastener. These are general instructions for installation of the Pedi-Mate®. Safe and proper use of the Pedi-Mate® is solely at the discretion of the user. Stryker recommends that all users be trained on the proper use of the Pedi-Mate® before using it in an actual situation. Retain these instructions for future reference. Include them with the product in the event of transfer to new users. Failure to follow the cleaning directions when using the specified types of cleaners may void this product’s warranty (see page 148).
Return To Table of Contents 16
6550-309-001 REV A
www.stryker.com
Summary of Safety Precautions PINCH POINTS
WARNING: Pinch Point
WARNING: Pinch Point between litter interface and base when lowering litter.
WARNING: Pinch Point
Figure 3: Potential Pinch Points
Return To Table of Contents www.stryker.com
6550-309-001 REV A
17
Setup Procedures Ensure that all shipping and packaging materials have been removed from the product(s) prior to use. Unpack the cartons and check all items for proper operation. It is important that the cot is working properly before it is put into service. Have a qualified service person use the Product Inspection checklist on page 19 and the operation instructions to check the cot before it is put into service. See Figure 2 on page 12 to identify all of the cot components. The patient compartment of the vehicle in which the cot will be used must have a: • Level floor large enough for the folded cot. • Stryker Model 6385, 6386, 6387, 6388, or 6389 Cot Fastener System (not included). Note: Loose items or debris on the patient compartment floor can interfere with the operation of the cot fastener. Keep the patient compartment floor clear. When necessary, modify the vehicle to fit the cot. Do not modify the cot.
WARNING • •
Improper usage of the cot can cause injury to the patient or operator. Operate the cot only as described in this manual. Do not modify the cot or any components of the cot. Modifying the product can cause unpredictable operation resulting in injury to the patient or operator. Modifying the product also voids its warranty (see page 148).
Note: • This manual should be considered a permanent part of the cot and should remain with the product even if the cot is subsequently sold. • Stryker continually seeks advancements in product design and quality. Therefore, while this manual contains the most current product information available at the time of printing, there may be minor discrepancies between your cot and this manual. If you have any questions, please contact Stryker Customer Service or Technical Support at +44 (0) 1635 262431.
Return To Table of Contents 18
6550-309-001 REV A
www.stryker.com
Product Inspection The condition of the cot is the responsibility of the owner. It is important that the cot is working properly before the product is put into service. Have a qualified service technician use the following list and the operation instructions to check the cot before the product is put into service. The battery must be charged prior to checking the features and condition of the cot. Item Routine Battery Unpack batteries and charger Charge battery according to SMRT Power System instructions (6500-009-101) or DeWALT® Battery System instructions The power indicator LED, located on the height adjustment switch of the cot, is solid green when the battery is fully charged or has adequately charged battery power.
CAUTION When charging a battery in an ambulance, locate the charger in an enclosed cabinet and out of patient reach during transport. After the battery is fully charged, inspect the cot for the following points: Item Routine Battery Charge spare battery (if necessary) according to SMRT Pak or DeWALT® 34 battery instructions Install battery into foot end enclosure - power indicator LED operates 34
Hydraulics
Electronic Controls
Manual Back-up Release
Litter
Ensure that the battery remains firmly secured Release and remove battery from foot end enclosure Reinstall battery into foot end enclosure Inspect motor mount - all fasteners secure Check cylinder attachments at both ends - all fasteners secure Inspect main cable - all connections secure Inspect hoses and cylinder seal for leaks Check power indicator LED - charged Extend cot to raised position Check high speed retract Extend cot to full height - no drift Verify the manual back-up release handle functions properly - adjust accordingly With the cot empty, check the raise/lower function With the cot loaded with a minimum of 7 stones (45 kg) (100 lb), check the raise/lower function All fasteners secure (reference all assembly drawings) All welds intact - not cracked or broken No bent, broken, or damaged components Verify siderails operate and latch properly Verify backrest cylinder operates properly through range of motion Verify the footrest operates properly Install body restraints. Restraints intact and operating properly. No rips or tears in mattress cover
Page
34 34 34 62 62 62 62 36 31 31 31 32 32 32
41 41 43 38
Return To Table of Contents www.stryker.com
6550-309-001 REV A
19
Product Inspection Item Routine Head/Foot Section All fasteners secure (reference all assembly drawings) No bent or broken tubing or sheet metal Verify the head/foot section extends and retracts properly Base All fasteners secure (reference all assembly drawings) All welds intact - not cracked or broken No bent, broken, or damaged components Wheels and Tires No debris in wheels All wheels secure, rolling and swiveling properly Operate wheel locks (if equipped) - wheel secure when engaged, rolls freely when disengaged Accessories Verify I.V. pole (if equipped) operates properly Verify removable oxygen bottle holder (if equipped) operates properly Verify equipment hook (if equipped) is installed properly Verify Pedi-Mate® restraint package (if equipped) is installed properly Verify pocketed backrest storage pouch (if equipped) is installed properly Verify oxygen bottle holder (if equipped) operates properly Verify 36 in restraint extender (if equipped) is included
Page
42
44 47 50 51 53 54 40
Return To Table of Contents 20
6550-309-001 REV A
www.stryker.com
Cot Fastener Installation The Power-PRO TL Cot Fastener System, Model 6385, 6386, 6387, 6388, and 6389, are designed to be compatible only with cots which conform to the installation specifications listed on page 22. The Power-PRO TL Cot Fastener System, Model 6385, 6386, 6387, 6388, and 6389, are not designed for any other purpose than to restrict cot movement as it is being transported in the patient compartment of an ambulance under normal conditions. Usage of this product in any other way becomes the complete responsibility of the owner/user. Caution must be used at all times during placement of the cot into the ambulance.
WARNING It is the responsibility of the cot operator to ensure that the cot being used in the Stryker Cot Fastener Systems meets the installation specifications listed on page 22. Injury may result if a non-compatible cot is used in the Stryker Fastener System. For more information about the Power-PRO TL Cot Fastener System, Model 63585, 6386, 6387, 6388, and 6389, see the Cot Fastener Operations/Maintenance Manual (6385-009-001).
Return To Table of Contents www.stryker.com
6550-309-001 REV A
21