Intro SWITCHPOINT INFINITY™ CONTROL SYSTEM OPERATIONS AND MAINTENANCE MANUAL
This Operations and Maintenance Manual contains confidential information that shall not be disclosed or duplicated for any reason other than to use and maintain a SwitchPoint Infinity™ Control System installation. This restriction does not limit the right to use information contained in this manual if it is obtained from another source without restriction. The information subject to this restriction is contained in all pages of this manual.
Note:
The serial number for the SwitchPoint Infinity™ Control System is located on a sticker that is affixed on the upper left corner on the front of the unit.
System Install Date: _________________________ System Serial Number: _______________________
SWITCHPOINT INFINITY™ CONTROL SYSTEM OPERATIONS AND MAINTENANCE MANUAL Part # 1001-400-002 Rev C Dated: October 2004
© Copyright 2004 Stryker Communications Interactive Campus Telemedical System™, ICTS™, Electronic Presentation Podium™, Stryker TeleHealth Network™, and SwitchPoint Infinity™ are trademarks of Stryker Communications. Endosuite® OR is a registered trademark of Stryker Endoscopy. All Rights Reserved.
Stryker Communications
© Copyright 2004 - All Rights Reserved
877-789-8106
Software Version Installed: ____________________
12140 Community Road Poway, CA 92064
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
Stryker Communications
Telephone: 619-401-8400 Toll Free: 877-789-8106 Fax: 619-401-8484 E-mail: [email protected] www.stryker.com
INTRO-2
Intro
INTRODEFINITION OF SYMBOLS Please read this manual and follow its instructions carefully. The words WARNING, CAUTION, and NOTE carry special meanings and should be carefully reviewed: WARNING: The personal safety of the patient may be involved. Disregarding this information could result in injury to the patient. CAUTION:
Special service procedures or precautions must be followed to avoid damaging the instrument.
NOTE:
Special information to make maintenance easier or important information more clear
Denotes Class 1 and TYPE B EQUIPMENT.
© Copyright 2004 - All Rights Reserved
877-789-8106
Class 1 Equipment; Equipment in which the protection against electric shock does not rely on Basic insulation only, but includes an additional safety precaution in such a way that means are provided for the connection of Accessible Conductive Parts to Protective (Earth) Conductor in the fixed wiring of the installation in such a way that Accessible Conductive Parts cannot become Live in the event of a failure of the Basic Insulation. Type B Equipment, Type B Equipment is suitable for intentional external and internal application to the patient excluding Direct Cardiac Application. An exclamation point within a triangle is intended to alert the user to the presence of important operating and maintenance (service) instructions in the literature accompanying the product.
Stryker Communications Corporation
A lightning bolt within a triangle is intended to warn of the presence of hazardous voltages. Refer all service to authorized personnel. Denotes Compliance to CSA Std. C22.2 No. 601.1-M90 and UL 60601-1. 2nd Edition.
-3
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
Intro
WARNINGS AND CAUTIONS
INTRO
TO AVOID POTENTIAL SERIOUS INJURY TO THE USER AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE, THE USER MUST:
Read this operating manual thoroughly, and be familiar with its contents prior to using this equipment.
3.
Be a qualified physician/technician, having complete knowledge of the use of this equipment.
4.
Test this equipment prior to a surgical procedure. This product was fully tested at the factory before shipment.
5.
Avoid removing covers on the product to avoid an electric shock.
6.
Not attempt internal repairs or adjustments unless specifically instructed to do so in this operating manual.
7.
Pay close attention to the care, cleaning, sterilization, and disinfection instructions in this manual. A deviation may cause damage. DO NOT STERILIZE OR DISINFECT THE CONTROL UNIT OR THE TOUCHPANEL DISPLAY.
8.
Disconnect the unit from the electric outlet before inspecting system components.
9.
Read the entire instruction manual before assembling or connecting the unit.
CAUTION:
Stryker Communications has verified that the Switchpoint Infinity™ Control System complies with the electromagnetic compatibility requirements for medical devices as specified in IEC 60601-1-2: 2001. Radio-frequency (RF) communication equipment such as the wireless microphone in the Switchpoint Infinity™ Control System, however, can still affect other medical electrical equipment in the operating room. Prior to using this device in a surgical procedure, perform the following steps to ensure electromagnetic compatibility among operating-room devices: 1) Identify any critical care medical devices located within Switchpoint Infinity™ Control System’s communication range. (Theoretical maximum of 300 feet) 2) Test each device for compatibility with the Switchpoint Infinity™ Control System:
Stryker Communications accepts full responsibility for the effects on safety, reliability, and performance of the equipment only if:
a) Power on the critical care devices. b) Perform a variety of functions with the Switchpoint Infinity™ Control System, such as speaking through the microphone and powering on and off the microphones.
•
Readjustments, modifications, and/or repairs are carried out by persons authorized by Stryker Communications and
3) Reposition devices as necessary to maintain electromagnetic compatibility.
•
The electrical installation of the relevant operating room complies with the applicable IEC, CEC, and NEC requirements.
The warranty on this product is void if any of these warnings are disregarded.
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
-4
877-789-8106
2.
WARNING: Federal law (United States of America) restricts this device to use by, or on the order of a physician.
© Copyright 2004 - All Rights Reserved
Carefully unpack the unit and check if any damage occurred during shipment. If damage is detected, please see Damage Claims in the Appendix.
Stryker Communications Corporation
1.
Intro
INTROSAFEGUARDS & PRECAUTIONS IMPORTANT SAFEGUARDS/NOTICES FOR USE IN THE MEDICAL ENVIRONMENT All the equipment connected to this unit shall be certified according to Standard IEC601-1, IEC950, IEC65 or other IEC/ISO Standards applicable to the equipment.
•
Operate the unit on 100 VAC 50/60 Hz in Japan, 120 VAC 50/60 Hz in North America, and 100240 VAC 50/60 Hz in other locations.
•
The nameplate indicating operating voltage, power consumption, etc. is located on the front.
•
Should any solid object or liquid fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it any further.
•
To disconnect the AC power cord, pull it out by grasping the plug. Never pull the cord itself.
•
The socket-outlet shall be installed near the equipment and shall be easily accessible.
R
2. 0
m
et er s
1.
ON SAFETY
2.
The SwitchPoint Infinity™ Control System must be installed in a location that is at least 2 meters from a patient.
3.
The leakage current could increase when connected to other equipment.
4.
The operator should take precautions to avoid touching the front panel input and output circuitry and the patient at the same time.
5.
The SwitchPoint Infinity™ Control System is intended for use in a medical environment to route video signals and display video pictures from cameras or other video inputs.
Stryker Communications Corporation
© Copyright 2004 - All Rights Reserved
877-789-8106
ON INSTALLATION •
Allow adequate air circulation to prevent internal heat buildup. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation holes.
•
Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive dust, mechanical vibration or shock. If you have any questions about this unit, contact your authorized Stryker representative.
WARNING: For non-U.S. versions use a suitable “Medical-Grade” grounding plug and cord.
-5
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
TABLE OF CONTENTS
CONTENTS Definition of Symbols ... Intro-3 Warnings and Cautions ... Intro-4 Safeguards & Precautions ... Intro-5
CHAPTER 1– SYSTEM OVERVIEW SwitchPoint Infinity™ Control System ... 1-2 SwitchPoint Infinity™ Control System Components ... 1-3
CHAPTER 2– EQUIPMENT CONNECTIONS Connectors Used By The SwitchPoint Infinity™ Control System ... 2-2 Connections Overview ... 2-3
Troubleshooting Overview ... 4-2 Video Routing Tips ... 4-3 Routing Examples ... 4-3 Troubleshooting Video ... 4-4 Troubleshooting Audio ... 4-7 Troubleshooting High Resolution Switching ... 4-8 System Troubleshooting and Diagnostics ... 4-9
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
INTRO-6
© Copyright 2004 - All Rights Reserved
CHAPTER 4– TROUBLESHOOTING GUIDE
Stryker Communications
Touch Panel Interface ... 3-2 Touch Panel Functions ... 3-3 Menu Bar ... 3-3 Taskbar ... 3-4 Home ... 3-9 Presets ... 3-17 Calls ... 3-21 Climate Controls ... 3-27 Observation Room Controls ... 3-28 Room Lights ... 3-30
877-789-8106
CHAPTER 3– THE TOUCH PANEL INTERFACE
TABLE OF CONTENTS
APPENDIX
Stryker Communications
© Copyright 2004 - All Rights Reserved
877-789-8106
EULA Terms ... Appendix-2 Physical & Electrical Specifications ... Appendix-3 Maintenance ... Appendix-4 Service & Claims ... Appendix-5 Stryker Communications Limited Warranty ... Appendix-6
INTRO-7
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 1 SYSTEM OVERVIEW SWITCHPOINT INFINITY™ CONTROL SYSTEM OPERATIONS AND MAINTENANCE MANUAL
This Operations and Maintenance Manual contains confidential information that shall not be disclosed or duplicated for any reason other than to use and maintain a SwitchPoint Infinity™ Control System installation. This restriction does not limit the right to use information contained in this manual if it is obtained from another source without restriction. The information subject to this restriction is contained in all pages of this manual.
SWITCHPOINT INFINITY™ CONTROL SYSTEM SWITCHPOINT INFINITY™ CONTROL SYSTEM
The Switchpoint Infinity™ Control System is a medical device that is designed to allow direct control of the state, selection, and settings of room equipment, and audio/video equipment and indirect control through the Stryker Endoscopy Sidne™ System of the state, selection, and settings of surgical equipment in the operating room. The Switchpoint Infinity™ Control System is also an integrated voice, video, and data router and teleconferencing interface for the operating room. The intent of the Switchpoint Infinity™ Control System is to allow operating room personnel a center point for controlling all equipment and communication in surgery. The Stryker Switchpoint Infinity™ Control System is indicated for use with the Stryker Endoscopy Sidne™ System [510(k) # K022393] and Sidne™ compatible endoscopic and general surgery devices. The users of Switchpoint Infinity™ Control System are general sur-
A2
A8
geons, gynecologists, cardiac surgeons, thoracic surgeons, plastic surgeons, orthopedic surgeons, ENT surgeons, urologists, radiologists, and any other surgeon whom requires the use of voice, video, or control in the operating room or a teleconferencing interface.
AN INTEGRATED VOICE, VIDEO, AND DATA ROUTER AND CONFERENCING INTERFACE The SwitchPoint Infinity™ Control System is built with high quality video and audio components. It is designed to operate and communicate with a broad range of existing equipment produced by Stryker. The Touch Panel Interface provides a convenient, easy method to control every function of the SwitchPoint Infinity™ Control System. There should be no need to remove the front panel.
A14, A6, A15, A5 A12 A7 A16, A17
877-789-8106
INDICATIONS FOR USE
© Copyright 2004 - All Rights Reserved
C5 A1 A3
A4
A9 A10 A11
A13
B2
B1
D1
C1
C3
C2
Stryker Communications
B3
C4
SWITCHPOINT INFINITY™ CONTROL SYSTEM FRONT VIEW WITHOUT BEZELS SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 1-2
SWITCHPOINT INFINITY™ CONTROL SYSTEM COMPONENTS SWITCHPOINT INFINITY™ CONTROL SYSTEM COMPONENTS The SwitchPoint Infinity™ Control System consists of the following fully integrated components:
A.
Main Control System
B.
A1 - Power On/Off Switch
B1 - 12 S-Video Inputs and 14 S-Video Outputs
A2 - 1 AC Power Inlet
B2 - 12 RGB-HV Inputs and 14 RGB-HV Outputs
A3 - 3 Camera Power Outputs A4 - 2 Auxillary Power Outputs
B3 - 2 Composite Inputs and 2 Composite Outputs
A5 - 4 Auxillary Audio/Video Connections (optional) A6 - 1 RGB-HV Output for Touch Panel Connection
C.
C2 - 8 Line Level Outputs
A8 - 1 S-Video Output for Video Preview
C3 - 1 CPU Line Level Output
A9 - 1 S-Video Input for Video Preview 877-789-8106
Audio Mixer/Amplifier C1 - 8 Line Level or Microphone Level Inputs
A7 - 1 RGB-HV Output for Internal Use
C4 - 2 Speaker Level Outputs
A10 - 1 Composite Output (future use)
C5 - 1 Integrated CD Player with Headphone Output
A11 - 1 Speaker Line Output (future use) A12 - 2 VHDC Interface Outputs for RS-232 Breakout Connections A13 - 1 RS-232 Communications Port for Touch Panel Control A14 - 1 Ethernet Port
D.
RS-232 Connectivity D1 - 16 RS-232 ports for serial communications with external devices
A15 - 1 PS/2 Mouse Port A16 - 1 PS/2 Keyboard Port A17 - 1 USB Port
Stryker Communications
© Copyright 2004 - All Rights Reserved
Video Router
CHAPTER 1-3
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 2 EQUIPMENT CONNECTIONS SWITCHPOINT INFINITY™ CONTROL SYSTEM OPERATIONS AND MAINTENANCE MANUAL
This Operations and Maintenance Manual contains confidential information that shall not be disclosed or duplicated for any reason other than to use and maintain a SwitchPoint Infinity™ Control System installation. This restriction does not limit the right to use information contained in this manual if it is obtained from another source without restriction. The information subject to this restriction is contained in all pages of this manual.
CONNECTORS USED BY THE SWITCHPOINT INFINITY™ CONTROL SYSTEM CONNECTORS USED BY THE SWITCHPOINT INFINITY™ CONTROL SYSTEM The SwitchPoint Infinity™ Control System uses various commercial-grade video and audio cables to interconnect equipment. Three primary types of cables are used in wiring video systems: Composite cables, which have a BNC connector, RGB-HV cables, which have a HD-15 connector, and S-Video cables, which have a 4-pin miniDIN connector. BNC connectors are push and turn type connectors, HD-15 connectors are push and screw type connectors and DIN connectors are push only type connectors. On some monitors, S-Video inputs may be labeled Y/C or S-VHS and RGB-HV inputs may be labeled PC, Computer or VGA.
Stryker Communications
© Copyright 2004 - All Rights Reserved
877-789-8106
The room speaker connection on the SwitchPoint Infinity™ Control System uses a Phoenix connector. This connector secures with a push and lock motion.
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 2-2
CONNECTIONS OVERVIEW
VIDEO INPUTS
AUDIO INPUTS
There are 12 RGB-HV and 12 S-Video source inputs available to receive video directly from Endoscopic and Room Cameras, Printer, Digital Capture Device, VCR, Voice Control Device and other video device outputs. All of the connections are located on the front panel. For video source wiring, connect each video output to an available video input on the SwitchPoint Infinity™ Control System connection panel. Any video input may be used for connecting the video devices as there are no reserved video inputs for any specific devices.
There are 8 audio inputs available on the front panel of the SwitchPoint Infinity™ Control System. Each audio input can either take a line level or microphone level input from an external audio source. Any audio input may be used for connecting audio devices as there are no reserved audio inputs for any specific devices. For example, the wireless microphone receiver can be connected to any of the microphone inputs as can the Sidne/Hermes or the VCR.
VIDEO OUTPUTS
There are 8 line level outputs available on the front panel of the SwitchPoint Infinity™ Control System. Any audio output may be used for connecting devices as there are no reserved audio outputs for any specific devices. The Video Network Hub and Room Speakers are some of the devices that are connected to the audio outputs on the SwitchPoint Infinity™ Control System.
There are 14 RGB-HV and 14 S-Video outputs available to send video directly to monitors and/or flat panel displays. All of the connections are located on the front panel. For video output wiring, connect each monitor or flat panel input to an available video output on the SwitchPoint Infinity™ Control System connection panel. Any video output may be used for connecting the devices as there are no reserved video outputs for any specific devices. When connected to a video device, the SwitchPoint Infinity™ Control System will route the camera signal selected as the source to the device input and receive the output signal for further routing to a monitor (if selected).
Stryker Communications
© Copyright 2004 - All Rights Reserved
877-789-8106
CONNECTIONS OVERVIEW
AUDIO OUTPUTS
RS-232 CONNECTIVITY The SwitchPoint Infinity™ Control System has 16 RS-232 ports that can be used to connect devices that use serial communications, such as PTZ Cameras and Flat Panel monitors.
WARNING: Do not touch the internal pin of the BNC video out jacks and the patient simultaneously. Doing so will cause the patient to receive an electrical shock.
CHAPTER 2-3
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CONNECTIONS OVERVIEW VIDEO NETWORK HUB If your system is equipped with a Codec, the Codec will be housed in the Video Network Hub. The Video Hub is connected to the SwitchPoint Infinity™ Control System using the Audio In and Out connectors, the Ethernet connection and the video input and output connectors. Details of the connection and operation of the Video Network Hub are contained in the Operations and Maintenance manual for that equipment.
SIDNE™ VOICE ACTIVATION SYSTEM The SwitchPoint Infinity™ Control System can be configured to communicate with the Sidne™. Voice Activation System with an optional upgrade to the Sidne™ system. The SwitchPoint Infinity™ Control System and Sidne™ are connected via ethernet through a network router.
OPTIONAL EQUIPMENT CONNECTIONS
877-789-8106
The SwitchPoint Infinity™ Control System can be configured to allow you to connect your location to another department within your hospital or to another hospital or teaching facility located outside your hospital campus.
OR-BASED CONFERENCING EQUIPMENT
Note:
The actual cable connections to the SwitchPoint Infinity™ Control System must be synchronized with the software. This configuration is maintained in the Advanced Setup area of the user interface. Changing cable connections without changing the software configuration will result in system malfunction.
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 2-4
Stryker Communications
© Copyright 2004 - All Rights Reserved
In addition to the Video Network Hub, additional equipment will need to be installed in the operating room to accommodate video conferencing. The SwitchPoint Infinity™ Control System is designed to support several room cameras as well as additional video inputs and outputs. External speakers may be connected to the Speaker output port on the front connection panel.
CHAPTER 3 THE TOUCH PANEL INTERFACE SWITCHPOINT INFINITY™ CONTROL SYSTEM OPERATIONS AND MAINTENANCE MANUAL
This Operations and Maintenance Manual contains confidential information that shall not be disclosed or duplicated for any reason other than to use and maintain a SwitchPoint Infinity™ Control System installation. This restriction does not limit the right to use information contained in this manual if it is obtained from another source without restriction. The information subject to this restriction is contained in all pages of this manual.
TOUCH PANEL INTERFACE TOUCH PANEL INTERFACE The Touch Panel Interface controls every function of the SwitchPoint Infinity™ Control System.The touch panel offers a menu of options dependent on the equipment that is installed in that particular room. To use the touchpanel, simply touch the displayed “button” with the soft surface of your finger. The SwitchPoint Infinity™ Control System touch panel interface is divided into three main sections: the Menu Bar, the Control Section and the Taskbar.
Stryker Communications Corporation
CONTROL SECTION
TASKBAR
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
© Copyright 2004 - All Rights Reserved
877-789-8106
MENU BAR
CHAPTER 3-2
TOUCH PANEL FUNCTIONS
MENU BAR TOUCH PANEL FUNCTIONS MENU BAR The “Menu Bar” on the top of the screen directs you to the specified control areas of the SwitchPoint Infinity™ Control System. Each section manages different functions of audio mixing, video routing, device control, system set up and operation.
Stryker Communications Corporation
© Copyright 2004 - All Rights Reserved
877-789-8106
HOME Home is the portal to all the surgical devices, multimedia devices and room controls. By selecting the “Home” tab, the screen for control of a specific device or task can be invoked.
PRESETS Presets are a time saving function for remembering frequently used OR configurations, such as video routing, audio mixing, camera positioning, calls and lights.
CALLS The “Calls” menu controls the connection of the SwitchPoint Infinity™ Control System to various rooms within the hospital campus. It also provides access to off-site locations using a Codec installed in the Video Network Hub.
CHAPTER 3-3
Note:
Most styluses cannot be used on the SwitchPoint Infinity™ Control System’s touch panel interface. For best results, use your finger on the touch panel interface.
Note:
Avoid getting moisture on the surface of the screen and be careful not to scratch the surface with instruments or finger nails.
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
TOUCH PANEL FUNCTIONS
“TASKBAR” TASKBAR
“HELP - HOW TO” SCREEN HELP The SwitchPoint Infinity™ Control System’s Help screen offers tools for operating and troubleshooting the system. To access the Help section, press the Help button on the taskbar as shown above.
The Help - How To screen as shown above uses multimedia to show you how to operate different functions of the system. For example, it displays how to route video, how to make a call and how to control the speaker volume. You will also find the Stryker Communication Technical Support contact information in the Help section.
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 3-4
Stryker Communications Corporation
© Copyright 2004 - All Rights Reserved
877-789-8106
The “Taskbar” at the bottom of the screen provides quick access to some commonly used functions. These functions include the Help feature, Speaker Volume control, a Date and Time display, as well as the System Setup interface.
TOUCH PANEL FUNCTIONS
SPEAKER VOLUME PALETTE SPEAKER VOLUME The Volume button on the taskbar can be used to change the Room Speaker volume. It allows you to change the Room Speaker volume without having to go to the Audio Levels screen to increase, decrease or mute the Room Speaker.
The Status button allows you to jump to the video router status from any screen without having to go through the Home screen.
Stryker Communications Corporation
© Copyright 2004 - All Rights Reserved
877-789-8106
STATUS
CD PLAYER PALETTE CD PLAYER The CD Player button allows you to control the CD player from any screen without having to go to the CD Player screen. The CD Player Control palette, which has all the most commonly used functions, shows up on top of the area above the CD button. Touch any part of the main screen to make the palette disappear.
CHAPTER 3-5
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
TOUCH PANEL FUNCTIONS
WALL CAMERA The Wall Camera button allows you to jump to the wall camera control from any screen without having to go through the Home screen.
ADVANCED SETUP The Advanced Setup button allows access to the Software Configuration screens of the SwitchPoint Infinity™ Control System.
877-789-8106
If the Sidne™ Voice Activation System is configured to work with the SwitchPoint Infinity™ Control System, a screen requesting which system you want to configure will appear when the Advanced Setup button is pressed. This screen shot is on the next page for reference. Select the system you wish to configure.
Stryker Communications Corporation
© Copyright 2004 - All Rights Reserved
If the SwitchPoint Infinity™ Control System is selected, the “About Infinity” screen shows up as shown on the next page. This screen displays the Institution Name, Room Name and Software Version. Press the login button located at the top right hand corner to access the Advanced Setup screens on the SwitchPoint Infinity™ Control System. These screens should only be accessed by a Stryker representative or authorized personnel.You will be prompted to enter the username and password for security purposes. Note that the Advanced Setup screens can only be accessed from the local touch panel interface of the SwitchPoint Infinity™ Control System.
SWITCHPOINT INFINITY™ CONTROL SYSTEM - OPERATIONS AND MAINTENANCE MANUAL
CHAPTER 3-6