Stryker
Vision Elect HDTV LCD Monitor User Guide Rev E Nov 2008
User Guide
29 Pages
Preview
Page 1
Stryker Endoscopy 5900 Optical Court, San Jose, CA 95138
APPROVALS DRAWN BY:
DATE
D. Tea ORIGINATOR
11/04/08
TITLE
VisionElect HDTV User Guide (Domestic)
11/04/08 DOCUMENT NO.
D. Tea SIZE
REV.
A
E
LTR A B C D E F G H J K L M N P R T U V W Y
ECN NO. ECO 108576 ECO 109311 ECO 109709 ECO 110579 ECO 114780
1000-401-075 REVISIONS DATE 11/13/07 12/21/07 01/22/08 03/13/08 11/04/08
APPROVED D. Tea A. Infanger M. Rubina M. Rubina D. Tea
LTR
ECN NO.
REVISIONS DATE
SHEET
OF
1
29
APPROVED
Printing Instructions 1. 2. 3. 4.
Black and White 8.5” h × 5.5” w Select binding and paper weight based on cost Source files are available from Engineering Services
Global Source Archive this document as a user guide/manual. This document contains the following languages: 1.
English
VISION ELECT HDTV
26” High-Definition LCD Monitor REF
0240030960
User Guide English
2008/11
www.stryker.com
1000-401-075 E
100 mm (3.94”)
121.2 mm (4.77”) mm 3 mm (0.12”) 3mm
mm (2.04”) 53 mm
428.8 mmmm (16.88”) 345.8 mmmm (13.61”)
mm (9.01”) 228.8 mm
mm 327 mm (12.91”)
194 mm mm (7.64”)
mm(1.89”) 48 mm
3 mm mm (0.12”)
110.2 mm (4.34”) mm 552.1mm mm (21.74”)
616.4 mm (24.27”)
100 mm100mm (3.94”)
VISION ELECT HDTV English 26” High-Definition LCD Monitor
Table of Contents Warnings and Cautions ... EN-2 Warnings ... EN-2 Cautions ... EN-3 Symbol Definitions ... EN-5 Product Description and Intended Use ... EN-6 Product Contents ... EN-6 System Interconnection ... EN-8 Power Connection... EN-8 Operating the Monitor ... EN-9 Front Panel Controls ... EN-9 Rear Panel Panel ... EN-10 Input Port Layout... EN-10 Fiber Optic Module (optional) Installation ... EN-11 Input Selection List... EN-11 Standard On-Screen Display (OSD) Operation ... EN-12 Stryker Camera Preset Modes... EN-12 OSD Function Description ... EN-13 Cleaning the Monitor... EN-14 Cleaning display plastic area ... EN-14 Cleaning display filter area... EN-14 Troubleshooting ... EN-15 Technical Specifications... EN-16 Classification and Approvals ... EN-17 Electromagnetic Compatibility... EN-18 Warranty ... EN-23 Service and Claims... EN-23 Declaration of Conformity ... EN-24
EN-1
Warnings and Cautions Please read this manual and follow its instructions carefully. The words Warning, Caution, and Note carry special meanings and should be carefully reviewed: Warning
The personal safety of the patient or physician may be involved. Disregarding this information could result in injury to the patient or physician.
Warning
A lightning bolt within a triangle is intended to warn of the presence of hazardous voltage. Refer all service to authorized personnel.
Caution
Special service procedures or precautions must be followed to avoid damaging the instrument.
Note
Special information to make maintenance easier or important information more clear.
Warnings Warning
To avoid potential serious injury to the user and the patient, and/or damage to this device, the user must:
1. Restrict this device to use by, or on the order of, a physician, because of Federal law (United States of America). 2. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment. 3. Carefully unpack the unit and check if any damage occurred during shipment. 4. Test this equipment prior to a surgical procedure. This monitor was fully tested at the factory before shipment. 5. Do not place the monitor or any other heavy object on the power cord. Damage to the cable can cause fire or electric shock. 6. Should any solid object or liquid fall into the panel, unplug the unit and have it checked by qualified personnel before operating it any further. 7. Unplug the unit if it is not to be used for an extended period of time. To disconnect the cord, unscrew plug first, then pull it out by the plug. Never pull the cord itself. 8. To avoid electric shock, avoid removing control unit covers.
EN-2
9. Do not attempt internal repairs or adjustments not specifically detailed in this operating manual. 10. Pay close attention to the care and cleaning instructions in this manual. A deviation may cause damage (refer to the Cleaning section). 11. Do not sterilize the monitor. 12. Use appropriate caution to prevent contact with fluids if the unit is being used with a power supply in patient environments.
Cautions 1. The AC Adapter must be plugged in to a grounded power outlet. 2. Use only the proprietary VISION ELECT HDTV power supply (P/N 240-030-950, Manufacturer: JEC Korea, Model No: JMW1150KA2400F07) for the VISION ELECT HDTV monitor (model 240-030-960). Completely secure the connection between the DC power cord and the extension cord. 3. Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle labeled “Hospital Only” or “Hospital Grade.” 4. To connect to an international power supply, use an attachment plug appropriate for the power outlet. 5. Turn power off when the unit is not in use. 6. Remove the power module and connection when transporting the unit. 7. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit. 8. Handle the monitor with care. Do not strike or scratch the screen. 9. Never operate the unit right after having been transported from a cold location directly to a warm location. 10. Do not expose the monitor to moisture or apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean gently. 11. Allow adequate air circulation to prevent internal heat buildup. 12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation slots. The monitor is cooled by natural convection and has no fan. 13. Do not install the unit near sunlight, excessive dust, mechanical vibration, or shock. 14. The unit is designed for operation in a horizontal position. Do not operate the unit in a vertical position. EN-3
English
15. Keep the unit away from equipment that uses strong magnets (i.e., large loudspeakers). 16. Do not touch the patient with signal input or output connectors. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or IEC 60601-1-1 harmonized national standards or the combination should be evaluated. 17. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note
This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures: • • •
•
Reorient or relocate the receiving device. Increase the separation distance between the equipment. Connect the equipment to an outlet on a circuit different from that to which the other device(s) are connected. Consult the manufacturer or field service technician for help.
18. To ensure electromagnetic compatibility, refer to the “Electromagnetic Compatibility” section of this manual. The VISION ELECT HDTV (model 240-030-960) monitor must be installed and operated according to the EMC information provided in this manual. The VISION ELECT HDTV (model 240-030-960) monitor has been tested under the UL 60601-1 standard and is UL listed for medical application. The warranty is void if any of these warnings or cautions are disregarded.
EN-4
Symbol Definitions
English
The following symbols appear on the product, its labeling, or the product packaging. Each symbol carries a special definition, as defined below: Dangerous: High Voltage
Consult accompanying documents Direct Current Indicates protective earth ground For indoor use only DC power control switch
SN
Serial Number Top - Bottom Fragile Do not get wet
3
Maximum Stacking
Manufacturer
European Authorized Representative Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities
51LJ Medical Equipment E215822
Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1 in regards to electric shock, fire hazards, and mechanical hazards
Tested to comply with FCC Class B standards
IPX1
Degrees of protection against the ingress of water This symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment.
•
DC power on at locker switch
EN-5
Product Description and Intended Use The VISION ELECT HDTV (model 240-030-960) High Definition LCD Monitor is an intelligent, microprocessor-based TFT-LCD monitor intended for use in endoscopic surgical applications. It has an ergonomically designed display and is compatible with most analog RGB (Red, Green, Blue) display standards. The VISION ELECT HDTV (model 240-030-960) monitor has the following features: • Advanced Viewing Solution (AVS): A sophisticated filter extends the viewing angle of the screen image, without sacrificing contrast ratio and brightness. • Upgraded video cards or software will not require buying a new monitor because of the wide auto-scanning compatibility range. • The internal microprocessor digitally controls auto-scanning, for horizontal scan frequencies between 31.47 KHz and 78.88 KHz, and vertical scan frequencies between 50.0 Hz and 85.1 Hz. In each frequency mode, the microprocessor-based circuitry allows the monitor to function at the precision of a fixed frequency. • The resident memory allows for storing factory default settings and also additional user adjustment parameters. • The maximum resolution achievable is WUXGA (1920 × 1200, 60Hz). • The monitor is compliant with the VESA-DPMS powermanagement standard. In order to save energy, the monitor must be connected to a system compliant with the standard. • The monitor is designed to mount an accessory (such as a camera or speaker) with a 2 lbs (max) load per hole. • The monitor is certified by UL International in accordance with medical standard UL 60601-1. It is also CE marked for sale in the European Community for integration or use with medical products.
Product Contents 1. Carefully unpack the VISION ELECT HDTV (model 240-030-960) monitor. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit. 2. Check the monitor and its accessories for any damage that may have occurred during shipping. Immediately report any damage to the shipping company. EN-6
3. Check the contents of the accessories package with the following list to make sure all components have been included. In addition English to this manual, you should find: Included Accessories (a) 1 AC adapter (Stryker P/N 240-030-950, Manufacturer: JEC, Model No: JMW1150KA2400F07) (b) 4 M4 × 10mm VESA screws (c) 2 Cable-managerment clamps Optional Accessories (not shown) 1. Fiber optic module (Stryker P/N 240-030-962) 2. 15-ft. (5 pin) DC extension cable (Stryker P/N 240-030-951) 3. 75-ft. (5 pin) DC extension cable (Stryker P/N 240-030-952) 4. 2-to-5 pin DC convertor adapter (Stryker P/N 240-030-953) 5. DVI cable 6. VGA HDDB15 cable 7. BNC cable 8. S-Video cable 9. Hospital-grade AC power cord
EN-7
System Interconnection VISION ELECT HDTV (Model 240-030-960) VISIONELECT Video Input Signals
(Model 240-030-930) SD/HD-SDI output
Video Input Signals Additional Inputs: RGBS YPbPr SD/HD-SDI SOG
Signal Output Output: Signal DVI DVI RGBHV RGBHV S-Video S-Video C-Video C-Video SDI
VideoPeripheral Peripheral Video
Fiber (Optional)
eg: SDC SIDNE eg:SDC VIDEO PRINTER SIDNE DVD/VCR VIDEO PRINTER etc... DVD/VCR etc...
Video Camera (xx88 Series) VideoSources: Sources:
Camera (1188 Series, 1088 Series, 988 Series)
Power Connection Hospital-grade power cord
Power Supply 240-030-950 Manufacturer: JEC Korea Model No: JMW1150KA2400F07
VISION ELECT HDTV (Model 240-030-960)
Extension cord (Optional) Manufacturer: JEC Korea Stryker P/N: 240-030-951 (15ft) or 240-030-952 (75ft)
EN-8
Operating the Monitor
English
Front Panel Controls Operate the monitor using the rotary control located on the front panel. A list of the monitor controls and their functions is provided below.
Power LED Rotary Control
Power Switch (Soft) Figure 1:
The VISION ELECT HDTV LCD Monitor front panel controls.
1. Power LED: Indicates menu current status. Displays green if monitor is powered on; blinks red if monitor is in Standby mode. 2. Power Switch (Soft): Turns the power ON or OFF. 3. Rotary Control (Turn Right / Left): With the on-screen display menu activated, increases/decreases the value of the selected parameter. With the on-screen display deactivated, activates the video source selection menu. 4. Rotary Control Switch (Push): Accesses/selects on-screen display menu. 5. Rotary Control Switch (Push and Hold): Exits on-screen display menu.
EN-9
Rear Panel Panel VESA mounting holes (100mm)
Power connector Connector tags
Power Switch (Hard)
Cable Managerment Clamps Figure 2:
The VISION ELECT HDTV LCD Monitor rear panel.
1. VESA mounting holes (100mm): Use to mount the monitior. 2. Power connector: DC power connector. 3. Power switch (Hard): Turns the input DC power ON or OFF. 4. Connectors tag: Indicate types of connectors. 5. Cable-managerment clamps: Cables organizer.
Input Port Layout Power Power Optical DVI Switch 24V (optional) (hard)
EN-10
VGA
S-Video C-Video/ G/Y H-sync HD/SD HD/SD RS232 SOG SDI R/Pr B/Pb V-sync SDI OUT IN
Fiber Optic Module (optional) Installation
English
Unscrew those 2 screws
1. Power OFF the monitor using the hard power switch. 2. Unscrew the two screws from the cover plate, then remove the cover plate. 3. Insert the Fiber Optic Module (Stryker P/N 240-030-962) into the Fiber Optic Module slot. Caution
Excessive force or misalignment during insertion might damage the module connector.
4. Power ON the monitor using the hard power switch.
Input Selection List Digital RGB Analog RGB HD/SD-SDI Component (Y/Pb/Pr) RGBS S-Video C-Video SOG Exit
EN-11
Standard On-Screen Display (OSD) Operation The monitor provides an on-screen display to help navigate through the various monitor-adjustment menus. 1. Press the Rotary Control to activate the on-screen display (OSD) menu. 2. Rotate the Rotary Control to move up or down through the menu. The parameter will be highlighted when selected. 3. Press the Rotary Control to enter the next level OSD. 4. Rotate the Rotary Control to increase or decrease the value of the selected parameter, or to make a selection on different options. 5. To exit the OSD menu screen from the second- or third-level OSD menu, select the Exit option. To completely exit the OSD, press and hold the Rotary Control. If no keys are pressed for a time period, the OSD automatically times out. 6. While the OSD menu is deactivated, rotate the Rotary Control to activate the input signal selection menu. The current input signal will be highlighted with a dot. Rotate the Rotary Control to select the preferred input signal.
Stryker Camera Preset Modes Camera
Resolution (H x V)
Horizontal Frequency (KHz)
Vertical Frequency (Hz)
988
1024 x 768
49.09
59.90
988i
1024 x 768
41.25
50.00
1088/SDC Pro2
1024 x 768
50.03
60.00
1088i/SDC Pro2
1024 x 768
41.10
50.00
1088/1188/SDC HD
1280 x 1024
64.02
60.10
1088i/1188i/SDC HD
1280 x 1024
59.99
50.00
1188w720
1280 x 720
45.00
60.00
1188iw720
1280 x 720
37.50
50.00
EN-12
OSD Function Description Item
Function Description
Range
Specialty Color Temperature *
Chooses between color temperatures for Standard, Arth, Lap, PACS, or Norm
Red
Red balance
Green
Green balance
-128 to 128
Blue
Blue balance
-128 to 128
Gamma
Gamma value
0.1 to 2.5, S0, S1, S2
Brightness
Increases or decreases the brightness
0-100
Contrast
Increases or decreases the contrast
0-100
Phase**
Increases or decreases the Phase level
0-100
-128 to 128
Setting
Chroma**
Increases or decreases the Chroma level
0-100
Image Sharpness
Sets image sharpness
1-10
Video Sharpness**
Increases or decreases the video sharpness
0-100
Image Effect Scale Mode
Chooses scale mode between Fill All, V-Fill, H-Fill, One To One or Fill To Aspect
Freeze Frame
Enables or Disables freeze frame
Zoom/Pan
Enables zoom-in and pan function
PIP
Enables PIP (Picture In Picture) function
POP
Enables POP (Picture On Picture) function
PBP
Enables PBP (Picture By Picture) function
Advanced OSD Control
Controls OSD Menu Position, Background, and Timeout
Screen Control***
Controls and adjust Horizontal, Vertical, Frequency, Phase
DPMS
Chooses DPMS (Display Power Management Signaling)
Auto Source Select
Adjusts Auto Source Select between on and off
Restore Factory Settings
Sets to factory default
Key lock
Sets to Key lock mode
ON, OFF, 30min, 60min, 90min, 120min
Information User Name Entry
Enters custom username display for boot-up display
Serial Number
Displays monitor serial number
Runtime
Displays current run time of monitor
Input Format
Displays current input format
Actual on-screen display values may vary with updated versions of the firmware and user setting. * Color Temperature RGB adjustment is avilable only for Standard, Arth and Lap settings. * PACS and Norm selection only available under SOG input. ** Only available under SDI, S, or C video input. *** Only available under VGA input.
EN-13
English
Cleaning the Monitor Caution
Do not expose the monitor to moisture or apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean the screen gently.
Cleaning display plastic area No specific liquid or chemical is necessary for cleaning the VISION ELECT HDTV (model 240-030-960) LCD monitor. Use only non-abrasive cloths and cleaning solutions to clean similar equipment used in hospitals. 1. Clean with a dry soft cloth, or a soft cloth lightly moistened with mild detergent solution. Do not use any type of solvent, such as alcohol or benzine, which might damage the finish. 2. Apply alcohol to glass surfaces with soft cotton applicator to aid in cleaning and drying without leaving spots or streaks. 3. Dry thoroughly with soft towel or gauze surgical sponge. Acceptable cleaning agents for bezel cleaning include: • Cidex (2.4% glutaraldehyde solution) • 0.5% Chlorhexidine in 70% isopropyl alcohol
Cleaning display filter area Clean with a dry soft cloth, or soft cloth lightly moistened with warm water. Other acceptable cleaning agents are listed below: • 70% isopropyl alcohol • Cidex (2.4% glutaraldehyde solution) • 0.5% Chlorhexidine in 70% isopropyl alcohol
EN-14
Troubleshooting
English
Before returning your LCD monitor for service, consult the troubleshooting list below: Problem
Current Status LED ON
Remedy Using the OSD, adjust the brightness and contrast to maximum, or reset them to their default settings. Check the power switch at the front and back of the monitor.
No Picture
LED OFF Check if the AC power cord is properly connected to the AC adapter. Check if the video signal cable is properly connected at the back of the monitor. LED Blinking Check if power of the video signal source system is ON.
Abnormal Picture
Oversized, undersized display, missing display, or center shift
Using the Screen Menu, adjust the PHASE, FREQUENCY, HORIZONTAL, and VERTICAL settings with non-standard video signal timing. Wait a few seconds after initial sync of video signals, or power cycle the monitor.
EN-15
Technical Specifications Display LCD Monitor Panel Synchronization Pixel Pitch Response Time View Angle Display Colors Native Resolution Input Signal
Maximum Pixel Clock Electrical Power Adapter Power Consumption Current Dimensions Dimensions (W × H × D) Weight VESA Mounting Interface
25.54 inches (a-Si TFT Active matrix LCD) 2.5 - 5.0 Vpp separated sync 0.2865(W) × 0.2865(H) <25ms Typ +/-89° (L/R) × +/-89° (U/D) 16 million colors 1920 dots × 1200 dots 1 × DVI 1 × VGA 1 × HD/SD-SDI 1 × C-Video/SOG 1 × S-Video 1 × Component (Y/G, Pb/B, Pr/ R, H/CS, VS) 1 × Optical (optional) 170MHz
AC 100-240V; DC 24V 150W (max) Direct
616.4 × 428.8 × 121.2mm (24.27 × 16.88 × 4.77 inches) 19.62 lbs VESA 100 × 100mm
Operating Conditions Operating Temperature Relative Humidity Atmospheric Pressure Range Electrical Input Rating
50 to 104ºF (10 to 40°C) 30 to 75% 500 to 1060 hPa 24V DC 6.25A
Transport & Storage Conditions Storage Relative Humidity Range Atmospheric Pressure Range
-4 to 140°F (-20 to 60°C) 10 to 85% 500 to 1060 hPa
EN-16
Classification and Approvals
English
51 LJ Medical Equipment E215822
Class I Equipment Medical equipment with respect to electric shock, fire and mechanical hazards only in accordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1. IPX1 Water Ingress Protection Continuous operation Warning
This equipment is not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR, or WITH OXYGEN OR NITROUS OXIDE.
This monitor is intended for use on Health Care Facilities model 240-030-960. No user serviceable parts inside. Ask qualified personnel before accessing internal components. Caution
For disposal of waste product, follow the requirement of the local code.
This product is considered electronic equipment. It must not be disposed of as unsorted municipal waste, and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment.
EN-17