Swemac Innovation

Medoff Sliding Plate System Instructions For Use

2 Pages

Medoff Sliding Plate System - Instructions For Use English IFU-P123-EN-20200817 Swemac Innovation AB Cobolgatan 1 SE-583 35 Linköping, Sweden Phone: +46 13374030 E-mail: info@swemac.com http://www.swemac.com  0413  FURTHER INFORMATION: This Instruction For Use leaflet is only provided in English. Other languages of this leaflet, the recommended surgical technique and detailed instructions for cleaning, sterilization and resterilization can be downloaded in PDF format from the Swemac website http://download.swemac.com/Medoff-Sliding-Plate. Printed documentation can be provided free of charge upon request. Delivery time is maximum 7 days. INTENDED USE: The Medoff Sliding Plate System is an implant system intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved. Description: The Medoff Sliding Plate System includes anatomically shaped hip plates with a built-in compression slide. All plates can use either a Swemac Lag Screw or a Hansson Twin Hook for fixation in the femoral head. The implants are single use devices made of implantable stainless steel (ISO 5832-1) and are available in different sizes. The system includes specific instrumentation for the procedure. The device is for professional use only. Indications: • Unstable trochanteric hip fractures. • Subtrochanteric hip fractures. • Combined trochanteric and subtrochanteric hip fractures. • Trochanteric and subtrochanteric non-unions. Contraindications: The surgeon’s education, training and professional judgment must be relied upon to choose the most appropriate device and treatment. Conditions presenting an increased risk of failure include: • Any active or suspected latent infection, sepsis or marked local inflammation in or around the surgical area. • Material sensitivity, documented or suspected. • Physical interference with other implants during implantation or use. • Compromised vascularity, inadequate skin or neurovascular status. • Compromised bone stock that cannot provide adequate support and/or fixation of the device due to disease, infection or prior implantation. • Patients who are unwilling or incapable of following post-operative care instructions. • Other physical, medical or surgical conditions that would preclude the potential benefit of surgery. • Previously implanted or extracted osteosynthesis implants of the diaphyseal or proximal femur increases the risk of secondary fracture. • Obesity. An obese patient can produce loads on the implant that can lead to device/treatment failure. • Use with pediatric hip fractures. COMPATIBILITY: The components included in this system have not been tested for safety, heating, or migration in an MRI environment. Similar products have been tested and evaluated in terms of how they may be safely used using MRI equipment. Prior to an MRI scan, a patient with a Swemac implant must always disclose the specific implant information to their physician. For details see Swemac MRI Statement. The plates in the Medoff Sliding Plate System can be used in combination with either a Swemac Lag Screw or a Hansson Twin Hook. All plates in the system are compatible with the Swemac Lateral Support Plates. WARNINGS: • Do not use the device without reading the surgical technique brochure, which has been provided to the user separately. • The device must only be used by a professional surgeon who is thoroughly familiar with the indications and contraindications, the implant, the methods of application, the biomechanical principles of the Medoff Sliding Plate system, instruments, and the recommended surgical technique of the device. • The implant can be available in different sizes and versions. It is important to select the appropriate combination of implant components and sizes taking into consideration the length, body weight, anatomy and functional demands of the patient. Implants which consist of several components must only be used in the described combination (see surgical manual). • Improper insertion of the device during implantation can increase the risk of loosening or migration. • Improper positioning of the device may lead to clinical failure. • Do not reuse the implants, since previous stresses may have created imperfections, which can lead to a device failure. • Do not touch sharp edges of instruments or implants. • If either the product or package seems damaged, contaminated or if sterility is questioned for any reason, the product shall not be used. • Do not re-use single use guide wires. Single use guide wires may be damaged or bent during surgical procedures. If a single use guide wire is re-used it may become lodged in a drill or reamer and unintentionally advanced into the body. • Drills and reamers with measuring function must not be re-sharpened. • Insufficient quantity or quality of bone/soft tissue may increase the risk of loosening or migration. • The implant is designed as a load sharing device and cannot withstand immediate weight bearing as a load bearing device. • Selecting the most appropriate fracture fixation method is extremely important. Failure to do so may accelerate clinical failure. Failure to use the correct component to maintain blood supply and provide rigid fixation may result in loosening, bending, cracking or fracture of the device and/or the bone. • It is important to ensure that neither the guide wire or drill penetrate the hip joint. • Do not use the reamer or drill if the cutting edge has been damaged or shows evidence of wear.  PRECAUTIONS: • Ensure that all components needed for the operation are available in the surgical theatre. • Inspection is recommended prior to surgery to determine if implants have been contaminated or damaged during transport or storage. • Handle instruments with care. Instruments should be examined for wear or damage prior to surgery. • Avoid surface damage to the implant and discard all damaged or mishandled implants. • After the procedure check the proper positioning of all implants using an image intensifier. Correct positioning of the implant parts is extremely important for the clinical outcome (see surgical manual). • Do not use components from Swemac in combination with components from other manufacturer’s systems. • The surgeon must be proficient in fracture reduction. • Prior to fixation of the Medoff Sliding Plate to the femur, ensure that the cortical screws will all traverse the canal of the femur when inserted. • The Swemac Lateral Support Plates can be used in combination with the Medoff Sliding Plate System to minimize the risk of medial displacement of the femoral shaft. • The Medoff Sliding Plate System is intended as a load sharing device; load bearing of the device without cortical contact across the fracture site should not be attempted. ADVERSE EFFECTS: • Pain, discomfort, abnormal sensations, nerve damage, soft tissue damage, infections, necrosis of bone, bone resorption, necrosis of the tissue or inadequate healing may result from the presence of an implant or due to surgical trauma. • Treatment failure such as fracture or loosening of the implant may occur due to excessive activity, prolonged loading upon the device, incomplete healing, delayed union, non-union or excessive force exerted on the implant during insertion. • Implant migration and/or loosening may occur. • Mal-union may occur. • Shortening of the affected bone/fracture site. • Metal sensitivity, histological or allergic reaction resulting from implantation of a foreign material may occur. POSTOPERATIVE CARE INSTRUCTIONS: Postoperative care is extremely important. The surgeon’s education, training and professional judgment must be relied upon to choose the most appropriate postoperative care. The patient must be cautioned about the use, limitations and possible adverse effects of this implant. The patient must also be warned that the implant and/or treatment might fail if she/he neglects the postoperative care instructions. • The implantation affects the patient’s ability to carry loads and her/his mobility and general living circumstances. For this reason, each patient needs individual instructions on correct behavior after implantation. • The implant is designed as a load sharing device and cannot withstand immediate weight bearing as a load bearing device. • Explain the need to report unusual changes in the implantation area as well as falls or accidents even if the device or the surgical area did not appear to be harmed at the time. Serious incidents shall be reported to Swemac and the Competent Authority. • Fixation of subtrochanteric and unstable intertrochanteric femoral fractures carries an increased risk of complications (for all types of fixation) due to the nature of the high forces across these types of fractures. Postoperative rehabilitation should not permit full weight bearing of the injured extremity until union has occurred across the fracture site. STERILITY: The implants are provided sterile. Sterile devices have been exposed to a minimum dose of 25.0 kGy gamma irradiation. If either the implant or the package appears damaged, or if sterility is questioned for any reason, the implant shall not be used. CLEANING AND DISINFECTION: The washer/disinfector used for the automated cleaning process should have proven effectiveness in accordance with ISO 15883. Multi-component instruments should be disassembled before cleaning. For details see Swemac reprocessing instructions. STERILIZATION AND RE-STERILIZATION: The instruments shall be sterilized and re-sterilized using a validated sterilization process in accordance with ISO 17665. Sterile packaging shall be done in accordance to EN-ISO 11607-1. Re-sterilization of sterile implant components is prohibited due to complicated assembly. Incorrect re-assembly may lead to clinical failure.  The following sterilization parameters are recommended:  132°C for minimum 4 minutes*  * Holding time. These times do not include air removal or penetration. STORAGE INSTRUCTIONS: The package should not be exposed to direct sunlight, ionizing radiation, extreme temperatures or particulate contamination. SYMBOLS USED ON THIS PRODUCT: Sterilized using irradiation  Do not use if package is damaged  Do not reuse  Consult instruction for use download.swemac.com  Caution  Do not re-sterilize  Non-sterile Keep away from sunlight  Medoff Sliding Plate System  134°C for minimum 3 minutes*  RxOnly  CAUTION: Federal law (USA) restricts this device to sale by or on order of a licensed physician or hospital.  Issued: 2020-08-17
File Type: PDF
File Size: 153 KB
File Name: Swemac Innovation - IFU-P123-EN-20200817 - Medoff Sliding Plate System Instructions For Use - 2020-08.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions